HomeMy WebLinkAbout05020002.3r— NOTE: PROVIDE DOWNSPOUTS AT BOTH EAVE LINES AT THE - RIDGE VENT
OPPOSITE END TO CURB LINE (DRAINAGE TO EMPTY ON SPLASH SHINGLES
BLOCKS ON THE EXISTING PAVING). F I
ALUM. FASCIA, GUTTER
AND FASCIA
SKIRTING TO MATCH SIDING —' � � STEPS
24 GAGE ALUM. SIDING THROUGH WALL HVAC UNITS (TYPICAL)
SEE SHEET G1.1 FOR STEPS PLATFORMS AND RAMPS LOCATION.
SIDE ELEVATION
SCALE: 1/4" = 1' -0"
Dino vrKir
TYPICAL END ELEVATION
SCALE: 1/4" = 1' -0"
WOOD RAILI
WITH CONCI
(SEE TYP.
4' MAX
2 X 4 RAIUNG ! — 2 X 4 RAILING
2 X 2 PICKETS 2 X 2 PICKETS
® 5" Q.C. 5' O.C.
2 X 4
E
2 X 6 DECKING
(ALLOW FOR EXPANSION) t
N
U-)
2 X 8 e �W_
1" � mow
o=
GRADE N 10 1 2 N N N
WIZ
Fr W LLJ
EMBED 4X 4 POST 2 X 12 STRINGERS
IN CONCRETE ! AND TREADS
o PAVEMENT EXISTING WALK AND CURB
0
N
FRAMING NOTES:
1. ALL FRAMING PRESERVATIVE TREATED #2 S.P.
2. ALL JOIST AND BEAMS 2 X 8
3. ALL POST 4 X 4
4. STAIR STRINGER CUT FROM 2 X 12
5. SUPPORT JOIST TO BEAMS WITH JOIST HANGERS
6. DECKING 2 X 6
1. NOTE: PROVIDE SIMILAR WOOD SUPPORT SYSTEM FOR HANDICAP RAMPS.
MAXIMUM RAMP PITCH = 1 IN 12_ SATISFY ALL ADA REQUIRERMENTS. DIMENSIONS
AND DETAILS. PROVIDE 1 1/4' DIA. GALV. PIPE HAND RAIL W/ BRACKETS BOTH SIDES AT
STANDARD ADA MOUNTING HEIGHT, ALL RAMPS.
2. NOTE: STAIR PLATFORMS AND RAMPS ARE NOT TO BE ANCHORED TO THE MODULAR BUILDING UNITS
3. NOTE: PROVIDE NEW PIERS AND FOUNDATIONS FOR STEPS, PLATFORMS, & RAMPS, AS REQUIRED..
4. NOTE: PROVIDE 2 NON -SLIP CLEAR EPDXY W/ SAND FINISH ON WOOD TREADS AND RAMP.
5. NOTE: FOR ORIENTATION SEE SHEET G1.1.
6. NOTE: ALL WOOD IS PRESERVATIVE TREATED
TYPICAL WOOD STAIRS SECTION
(LOCATE AT EXISTING CURB LINE)
10 1/'
EXISTING CONCRETE WALK
SCALE: 1/2' = 1' -0"
71I�[i t)■
NOTE: CONTRACTORS MAY SUBSTITUTE THEIR, TYPICAL METAL STEP PLATFORMS, RAMPS,
AND RAILINGS (NONSLIP TREADS AND RAMP) IN LIEU OF TREATED WOOD.
TYPICAL EXTERIOR DOOR PLAN LOCATION
SCALE: 1/2" = 1' -0"
t
N
J
vl
�I
10' STEEL BEAM
SHIM AS REQUIRED
SOLID CONCRETE
BLOCK
GRADE
TIE DOWN STRAP
ANCHORS 1/2' X
18" THREADED ROD
6 LOCATIONS
(SEE FOUNDATION PLAN)
POURED CONCRETE
PIER (3000 PSI)
TYPICAL CONCRETE BUILDING PIER DETAIL
SCALE: 1' = 1' -0"
f
t
K
AA' -n"
CLOSET tjtuutr, Iu rnuviut
BLOCKING IN WALL FOR
TV BRACKET
44' -0"
GENERAL NOTES FOR EACH UNIT
1. ALL LIGHT FIXTURES, SWITCHING, EMERGENCY, EXIT, & EXTERIOR UGHTING SYSTEM
(COMPLETE INSTALLATION) BY BIDDER.
2. ALL ELECTRICAL OUTLETS AND CLOCK OUTLET PROVIDE COMPLETE & HARDWIRED BY BIDDER.
3. BIDDER TO PROVIDE COMPLETE & OPERABLE FIRE ALARM & SMOKE DETECTION SYSTEM,
INCLUDING DEVICES, SELF CONTAINED EACH UNIT.
4_ BIDDER SHALL PROVIDE BUILT -IN CONDUIT & J BOXES FOR DATA, TELEPHONE & TV
(FINAL CONNECTIONS AND DEVICES BY OWNER)
5. BIDDER SHALL PROVIDE BUILT -IN CONDUIT, SPEAKER & CALL BUTTON (FINAL CONNECTIONS
BY OWNER)
TYPICAL FLOOR PLAN
NOTE: FOR ORIENTATION SEE SHEET G1.1
(WINDOWS ARE LOCATED ON SAME WALL AS DOORS)
SCALE: 1/4' = V -0"
A A' - /1"
TYPICAL FOUNDATION PLAN
SCALE: 1/4" = 1' -0"
JUNCTION BOX
FOR DATA & PHONE
v
z
0
W
H
Q
V
O
w
co
Q
W
3
O
D
z
z
z
Q
LL
tm
as
0
N
F
v
d
O
V
STATE OF
iii •. �ND 1 ANP.•'� `\\�
/llllllli���\
2' -0' 10' -0"
1
10' -0"
I
PERIMETER OF BUILDING
TIE DOWN ANCHORS
10' -0"
10' -O"
I
ct
FACING TOWARD INTERIOR
0
cr)
ct
�=
OF BUILDING, 6 REQUIRED
J
I
r
(fl
V
Q
!
o
O
02
i
I
Z
24" DIA. CONCRETE
o
Q
cr
PIERS, 15 REQUIRED.
i
m
C!)
0
>_
z
0
O
w
i
w
J
w
Uam
I
w
z
Ww
J
Jz
W
PERIMETER OF BUILDING
mo
M
U
44'
-0"
cc
TYPICAL FOUNDATION PLAN
SCALE: 1/4" = 1' -0"
JUNCTION BOX
FOR DATA & PHONE
v
z
0
W
H
Q
V
O
w
co
Q
W
3
O
D
z
z
z
Q
LL
tm
as
0
N
F
v
d
O
V
STATE OF
iii •. �ND 1 ANP.•'� `\\�
/llllllli���\
Cos)
CA
F-
ct
20
0
cr)
ct
�=
J
L)
V
Q
o
O
02
w
Z
0
V
Q
cr
w
Cn
p
C!)
3::
>_
z
tl)
O
Q
QQ
Jw
J
J
Uam
V
W
2
Ww
J
Jz
W
Q
mo
M
U
Q
�_
cc
F—
Q
CC
Ir
U
O
w
Cos)
CA
ct
O�''��
ct
O
L)
cu
rt�
w
U
u
r
7
z
0
a
0
z
0
U. a
z W
Q p
J
CL p
z
0a
0
J
u_
J
Q
0
D.
F-
0 0
O N
0
N c6
; N
C> >_
N
O
z
� H
O Q
V p
� m
}
m p
W
Y
Q W
W I
p �
W
H
Q
p
O
z
W
z
W
r
TOWNE MEADOW ELEM SCHOOL
204120.00