HomeMy WebLinkAbout04110036.12JACK'S TOOL RENTAL SITE 410 West Carmel Drive Carmel, Indiana IT I IBe, ''U��� �.,ISTO, • 4� •% D. Fire Hydrants: Shall comply with AWWA i : STATE OF .• 0 ����ir�SS I I A?i;' •�� N ZONAL 1111111 � July 15th, 2003 Approved By. D. Scott Bordenet Specification C -502 and shall meet local C H JV4 Construction Specifications Benchmark Surveying, Inc. 9855 Crosspoint Blvd., Suite 110 Indianapolis, IN 46256 standards and requirements, particularly as to � Project Description: Specifications this sheet present minimum requirements for specifications not stated elsewhere on the plans. Owner /Developer: nozzle diameters and threads, direction of ° CARMEL, IN 317-691- 7278 Rev# Date Remarks opening, and dimensions of operating and cap �- Added Sanitary Specs. H. Infiltration: Furnish necessary equipment to test nuts. Fire Hydrants shall have one pumper and � sewers for infiltration. Infiltration rates shall not two hose nozzles, a valve opening not less than 5 EYI� 7. SITE GRADING exceed the Local Standards. All sanitary sewer 3. APPLICATION [Jack's Tool Rental] inches, and a 6 inch inlet connection. The length 12 of 12 A. Grades: Do all cutting, filling, compacting of lines upon completion will be required to a A. Grading: Do any necessary grading in addition to of the hydrant barrel shall be determined by the Y fills and rough grading required to bring g g g q g pass low air test, unless otherwise directed by that performed in accordance with Earthwork specified depth of cover over the pipe. P P P P entire project area to subgrade as shown on P j g pressure Section to bring subgrades, after final the drawings. Undercut open areas 4 inches g P the sewer utility. Said test shall be conducted compaction, to the required grades and sections E. Valves: All valves and stops shall have ends for topsoil. according to NCPI Standard Method and shall be for site improvement. suited or adapters shall be provided far the P B. Rough grading: the tolerance for paved areas witnessed by an inspector authorized by the sewer B. Preparation of Subgrade: Remove spongy and proper installation in the lines in which they are shall not exceed 0.10 feet above established utility. Infiltration under the test shall not otherwise unsuitable material and replace with located. Valves shall meet local standards, or in subgrade. All other areas shall not exceed g exceed 100 gallons per inch of inside diameter of g P stable material. No traffic will be allowed on the absence of such standards, the following 0.10 feet plus or minus the established grade. sewer pipe per mile of sewer in 24 hours and prepared subgrade prior to paving. requirements. q Provide roundings at top and bottom of banks inclusive of all appurtenances within the section C. Compaction of Subgrade: The first 6 inches 1. Valves in cast iron pipe shall be iron body, P P Y and other breaks in grade. All open areas g P being tested such as manholes, house connections, below the subgrade shall be compacted to at least bronze mounted, disc gate valves shall be graded a minimum of 0.5% and a etc. 100% of the maximum dry density as determined conforming to AWWA Specification C -500. maximum of 3:1 slope. On fill slopes steeper P P P I. Flushing Sewers: Flush all sanitary sewers except by the of AASHTO T -99. Water They shell open in the same direction as than 4:1, step r break-up sloped surfaces so p P P building sewers with water to obtain free flow provisions shall be from standing on the those used in the local waterworks system. that fill will bond with existing urface. g through each line. Remove all silt and trash from prevented compacted subgrade. Valve stems shall terminate in 2 inch Maximum lift height shall not exceed 12 g appurtenances just prior to acceptance of work D. Utility Structures: Check for correct elevation of wrench nuts. Furnish two (2) keys. inches. J. Plastic Sewer Pipe Installation: Plastic sewer pipe all manhole covers, inlets, valve boxes and 2. Valves in copper pipe shall be standard C. Subgrade shall be proof rolled with suitable shall be installed in accordance with ASTM similar structures located within areas to be brass body, round-way, ground-key stops, y' y' g Y P ' equipment, and all spongy and otherwise P gY 02321 per latest revision, and no plastic pipe shall paved and mark, or have made any necessary with T heads. Furnish two (2) keys. unsuitable material shall be removed and exceed a deflection %of 5 K. Storm Water Connections: No roof drains, adjustments in such structures. F. Valve Boxes: Shall meet local standards or in the replaced with suitable material. footing drains and or surface water drains may be E. Placing Concrete: absence of such, shall comply with the following D. Sub grade for streets and paved areas shall be g P connected to the sanitary sewer systems, including i. Subgrade: Place concrete only on a moist, requirements: compacted to 100% of standard proctor in the P P temporary connections during construction. compacted subgrade of base free from loose 1. For iron body valves, boxes shall be upper 6" of depth. Depths of embankment L. Waterline Crossing: Where water lines and material. Place no concrete on a muddy or approved standard buffalo-type cast iron, PP YP below the upper 6" shall be compacted to PP P sanitary sewers cross and water lines cannot be frozen subgrade. adjustable shaft boxes, having a minimum j b' EARTHWORK 95% of standard proctor. placed above the sewer with minimum of 17 2. Forms: All forms shall be free from warp, shaft diameter of 5 -1/4 inches. 1. SCOPE OF WORK E. See PAVING section also. inches vertical clearance, the sewer must be tight enough to prevent leakage, and 2. For brass body valves (stops) boxes shall be A. Extent: The work required under this section F. All fill material shall be formed from soil tree constructed of water works ductile iron pipe substantial enough to maintain their shape approved standard cast iron extension consists of all excavating, filling, rough of deleterious material. If so required, prior to grade with mechanical joints not within 10 feet either and position without springing or settling service boxes, having a minimum diameter grading, and related items necessary to placement of fill, a sample of the proposed P P P P side of the water line. when concrete is placed. Forms shall be of 2 -1/2 inches and having lid held in place complete the work indicated on the drawings material shall be submitted to the soils M. Utilities: It shall be the responsibility of each clean and smooth immediately before b a brass or bronze bolt. The castings shall Y g and described in the specifications. engineer far approval. The fill material shall g PP contractor to verify all existing utilities and Y g concreting. be coated with two coats of coal -tar pitch 1. In general, the items of work to be g be placed in layers not to exceed 8 inches in conditions pertaining to his hose of the work. It P g P 3. Placing Concrete: Concrete shall be g varnish. Furnish two (2) keys for bolt in performed under this section shall P loose thickness and shall be spread and P ' shall also be the contractors responsibility to deposited so as to require as little handling lids. include: clearing and grubbing, removal compacted at the proper moisture content. P P P contact the owners of the various utilities before as practicable. When concrete is to be G. Plastic Pipe: Shall conform to ASTM D -2241- P of trees and stumps (where required), G. All fill material in areas outside of building work is started. The contractor shall notify in laced at an atmospheric temperature of 35 P P P joints SDR 21 with flexible elastomeric seal joints SDR 2 with protection of trees to remain, stripping and pavement areas shall be compacted P P writing the owners or the engineer of any changes, degrees F., or less, paragraph 702.11 of the to ASTM 0 -3139. NSF SEAL conforming OF and storage of topsoil, fill compaction, lightly with each lift and protected from errors or omissions found on these plans or in the Indiana Deportment of Transportation P P APPROVAL SHALL BE STAMPED ON ALL and rough grading of entire site as erosion. Areas of building construction shall g field before work is started or resumed. Specifications, latest revision shall be PLASTIC PIPE. indicated on the drawings. have suitable fill material placed and N. New Sanitary Sewer Construction: Contractor to followed. 3. APPLICATION: 2. Excavated material that is suitable may be compacted in accordance with the Soils P Engineers or minimum 95 % standard record dimensions of each service line stub from F. Concrete Curb and Gutter: A. Permits and Codes: The intent of this section of used for fills. All unsuitable material and report nearest downstream manhole measured along the 1. Expansion Joints: Shall be 1/z inch thick the specifications is that the contractor's bid on all surplus excavated material not proctor. sanitary sewer main. The locations of manholes premoulded at ends of all returns and a the work covered herein shall be based upon the required shall be removed from the site and service lines along with any other construction maximum spacing of 100 feet. drawings and specifications but that the work and appropriately placed. The location of SANITARY SEWER SYSTEMS changes are to be incorporated on the original 2. Contraction Joints: Unless otherwise shall comply with all applicable codes and dump and length of haul shall be the 1. SCOPE OF WORK The under this section includes all sanitary construction drawings and "Record Drawing" provided, contraction joints shall be joints P j j regulations. Contractor shall furnish all necessary b' Contractor's responsibility. work manholes, catch basins, cleanouts, and related prints submitted to the sewer as soon after spaced 10 feet on center. P bonds to et permits for cuts and connections. g P 3. Provide and place any additional fill sewers, items, including excavating and backfilling necessary to g Y completion of construction as possible. 3. Finish: Tamp and screed concrete as soon as B. Existing Improvements: Maintain in operating material from off the site as may be g g complete the work shown on the drawings, starting five placed, and fill any honeycombed places. condition all active utilities and sewers and other necessary to produce the grades required. Fill obtained from off site shall be of kind feet outside the building walls. The ends of sewers PAVING Finish square corners to 1/ inch radius and pipe system that may be encountered. and as specified for fills herein shall be tightly plugged or capped at the terminal 1. SCOPE OF WORK other corners to radii shown in plans. C. Trenching: Lay all pipe in open trenches, except quality and the source approved by the Owner. points adjacent to buildings, pending the connecting of The work required under this section G. Concrete Walks and Exterior Steps when local authority gives written permission for 4. The Contractor shall accept the site as he all such lines to the building drain as specified in the includes all exterior concrete and 1. Slopes: Provide 1/4 inch per foot cross slope. tunneling. Provide separate trench for the water at finds it and shall remove all trash, plumbing specifications and architectural drawings. bituminous paving and related items Make adjustments in slopes at walk least 10 feet horizontally from any sanitary sewer. rubbish and debris from the site prior to 2. MATERIALS necessary to complete the work indicated on intersections as necessary to provide proper In locations where separate trenches for sewer and starting excavation. A. Al' gravity plastic sewer pipe and fittings shall drawings and described in the specifications drainage. water lines are impracticable, lay the water pipe B. Work not included: The following items of conform to ASTM 03034, SDR -35. The including but not limited to: 2. Dimensions: Walks and steps shall be one- on a solid shelf at least 18 inches above the top of related work are specified and included in minimum cell classification for P.V.C. and Truss -All drives, parking areas in contract course construction and have widths and the sewer. other sections of these specifications. pipe shall be 12454 -B or 12454 -C. limits details shown on the drawings. D. Width of Trench: Excavate trenches 12 inches 1. Excavation, grading and backfilling for B. ABS sewer pipe and fittings shall conform to -Curbs and gutters 3. Finish: Screed concrete and trowel with a each side of the pipe for proper installation of utility lines. ASTM D2680 or latest revision. If using truss - Sidewalks and concrete slabs, steel trowel to a hard dense surface after pipe. 2. Storm drainage systems. pipe, joints shall be gasket type. exterior steps surface water has disappeared. Apply E. Sheeting and bracing: Sheet and brace trenches as 3. Sanitary sewer systems. C. Joints for P.V.C. and P.V.C. Truss pipe shall be 2. MATERIALS medium broom finish and scribe control necessary to protect workmen and adjacent 4. Water supply systems. compression type flexible gasketed joints. A. Concrete: Concrete shall be ready -mixed and joints at 6 foot spacing. Provide 1/z structures. All trenching shall comply with the 5. Streets and paving. 3. APPLICATION shall be a mix of proportioned fine and coarse expansion joints where sidewalks intersect Occupational Safety and Health Administration 2. BENCHMARKS A. Permits and Codes: The intent of this section of aggregates with Portland cement and water. and at a maximum spacing of 48 feet Standards. Carefully maintain all bench marks, monuments, the specifications is that the contractors bid on Minimum cement content shall be 6 bags per between expansion joints. F. Water Removal: Keep trenches free from water and other reference points. If disturbed or the work covered herein shall be based upon the cubic yard of concrete and maximum water H. Curing Concrete: Except as otherwise specified, while construction therein is in progress. Under destroyed replace as directed by engineer. drawings and specifications but that the work content shall be 5.5 U.S. gallons per sack of cure all concrete by one of the methods described no circumstances lay pipe or appurtenances in 3. REMOVAL OF TREES shall comply with all applicable codes and cement, including moisture in the aggregate. in Section 501.20 of the Indiana Department of standing water. Conduct the discharge from trench A. Remove all trees and stumps from areas to be regulations as amended by any waivers. Slump for normal weight concrete shall be a Transportation Specifications, latest revision. dewatering to drains, or natural drainage channels. occupied by road and surfaced areas. Contractor shall furnish all bonds necessary to maximum of 4 inches and a minimum of 2 I. Bituminous Pavement: Hot asphalt concrete G. Grading Trench Bottoms: The bottom quadrant of Removal trees these areas shall get permits for cuts and connections to existing inches. The slump of machine placed concrete pavement shall be as specified in Section 402 of the pipe shall be fully and uniformly supported. of outside only be done as noted on drawings or sewers. shall be no less than 1 -1/4 inches or more than 3 the Indiana Deportment of Transportation The full load shall rest on the barrel of the pipe. approved by the Owner. B. Local Standards: the term "Local Standards" as inches. Standard test ASTM C -143 shall be used Specifications, latest revisions. Paving will not be The trench may be excavated to a depth of 4 B. All brush, stumps, wood, and other refuse used herein means the standards of design and to measure slump. Minimum compressive permitted during unfavorable weather or when the inches or more below final grade with sand, from the trees shall be removed from site or construction of the City of Indianapolis Dept. of strength of concrete at 28 days shall be 3500 psi. temperature is 40 degrees F. and lolling. crushed stone or gravel backfill to bring it back to burned with (where Capital Asset Management. All exterior concrete shall have air entrainment J. Compacted Aggregate Sub -base: The thickness pipe laying grade. For a depth of at least 12 proper permits applicable). C. Existing Improvements: Maintain in operating of 5% to 8% by volume per ASTM C -260. shown on the drawings is the minimum thickness inches above the top of the pipe backfill with 4. PROTECTION OF TREES condition all active utilities, sewers and other Retempering of delivered concrete will not be of the fully compacted sub -base: Compaction earth or granular material free from large stones, General Protection: The Contractor shall be drains encountered in the sewer installation. allowed. Concrete shall be composed of: shall be accomplished by rolling with a smooth roots or frozen clogs. Tamp this backfill responsible for the protection of tops, trunks, Repair to the satisfaction of the owner any 1. Portland cement: conforming to ASTM C- wheeled roller weighing 8 to 10 tons. Compact to thoroughly taking care not to disturb the pipe. and roots of existing trees on the site existing damage. 150, Type IA or type IIA. 95% compaction using Standard Testing Backfill under walks, parking areas driveways and project that are to remain. Existing trees subject to D. Workmanship: To conform to all local, state and 2. Aggregates: conforming to ASTM C -33. Procedures. Along curbs, headers and walls and streets with granular material only, and tamp construction damage shall be boxed, fenced national codes and to be approved by all local 3. Water: Shall be clear and free from at all places not accessible to the roller, the thoroughly by approved methods. Trenches or otherwise protected before any work is and state agencies having jurisdiction. injurious amounts of oils, acids, alkalids, aggregate material shall be tamped with parallel to and within 10 feet of paved roadways started. Do not stockpile within branch E. Trenching: Lay all pipe in open trenches, except organic materials or other deleterious mechanical tampers or with approved tampers. shall also be constructed with compacted granular spread. Remove interfering branches without when the local authority gives written permission substances. WATER LINES H. material. Tests: Before joints are covered, fill the piping injury to trunks and cover soars with tree for tunneling. Open the trench sufficiently ahead B. Welded Steel Wire Fabric: Where required for with water, opening hydrants or other outlets to paint of pipe - laying to reveal any obstructions. The concrete reinforcement, shall conform to ASTM 1. SCOPE OF WORK 5. STRIPPING OF TOPSOIL width of the trench shall be the inside pipe A185. The work required under this section includes all expel air. Test the piping for leakage as required Remove topsoil to a depth of 6 inches (or diameter plus 24 inches for 12 inches above the C. Premoulded Joint Filler: Shall be non - extruding cold water distribution lines, valves meter pits, by local ordinances. Inspect all joints for leakage more if required) from the areas to be pipe. Sheet and brace trench as necessary to type meeting ASTM D -544, except that hydrants, and related items including excavating and remedy any leaks. Upon completion of the occupied by roads walks, buildings, and protect workmen and adjacent structures. All premoulded joint filler used in concrete walk and backfilling necessary to complete the work water lines, flush out the system until the water areas. Pile and store topsoil at a trenching to comply with Occupational Safety construction may be either non - extruding or shown on the drawings. The end of water runs clear. As soon as the system has been parking location where it will not interfere with and Health Administration Standards. Keep resilient. service lines shall be tightly plugged or capped at flushed out, it shall be sterilized in accordance construction operations. Top soil shall be trenches free from water while construction is in D. Bituminous Pavement Materials: All materials the terminal paints pending the connecting to all with the requirements of the water utility. reasonably free from subsoil, debris and progress. Under no circumstances lay pipe or proposed for the construction of bituminous such lines of the building piping as specified in I. If a horizontal distance of 10 feet cannot be stones. appurtenances in standing water. Conduct the pavements shall comply with Sections 400 and the plumbing specifications and architectural maintained between the water line and the 6. DISPOSITION OF UTILITIES discharge from trench dewatering to drains or 900 of the Indiana Department of Transportation drawings. sanitary sewer line, the sewer must be constructed A. Rules and regulations governing the natural drainage channels. Specifications. 2. MATERIALS of water works grade ductile iron pipe with 10' the respective utilities shall be observed in F. Special Supports: Whenever in the opinion of E. Compacted Aggregate Sub -base: Shall be A. Polyvinyl Chloride (PVC): PVC pipe, materials, mechanical joints not within of either side executing all work under this section. the Engineer, the soil at or below the pipe grade g� P P g crushed stone or gravel; Crushed gravel shall be and jointing shall conform to the requirements of � g q water line. B. It shall be the responsibility of each is unsuitable for supporting sewers and PP g a minimum of 35% crushed material. Fines shall the Indiana Plumbing Rules 675 IAC 5 and, g ( ) "Recommended J. Utilities. It shall be the responsibility of each contractor to verify all existing utilities and appurtenances specified in this section, such be limited to a maximum of 8% of the total. where applicable, to Standards contractor to verify all existing utilities and conditions to his phase of the special support, in addition to those shown or Material shall be free from an excess of flat, for Water Works" published by the Great Lakes- conditions pertaining to his phase of the work. It pertaining It shall also be the contractors specified, shall be provided as the Engineer may elongated, thinly laminated, soft or disintegrated Upper Mississippi River Board of State Public shall also be the contractor's responsibility to work. responsibility to contact the owners or the direct and the contract will be adjusted. pieces, and shall be free from fragments coated Health and Environmental Managers. contact the owners of the various utilities before before work is started The G. Backfilling: For a depth of at least 12 inches with dirt. Compacted aggregate shall be graded PVC pipe must have the NSF (National work is started. The contractor shell notify in various utilities shall notify in writing the owner or above the top of the pipe, backfill with granular as follows or per latest revisions: Sanitation Foundation) seal for potable water and writing the owners or the engineer of any changes, contractor the any changes, errors, or material tree from large stones, rock fragments, be rated to withstand the applied pressure. errors or omissions found on these plans or in the engineer of found on these or in the field roots or sod. Compact this backfill thoroughly, SIEVE SIZE % PASSING Solvent -weld fittings are not acceptable. Pipe field before work is started or resumed. omissions plans taking care not to disturb the pipe. For the shall meet or exceed AWWA, C -900, DR18. K. New Water Line construction: Contractor to before work is started or resumes. remaining trench depth, backfill with earth or 1" - 1/z" 100 B. Ductile Iron Pipe: Ductile iron pipe shall meet record dimension of each water stub and valves C. Where active utilities are encountered but not material containing stones or rocks not 1" 80 -100 AWWA C -150 and C -151 Specifications. from nearest fire hydrant measured along water shown on the drawings, the Engineer shall be granular larger than 4 inches. Backfill under walks, 3" - 4" 79 -90 C. Copper Tubing: Shall be seamless, annealed main, The locations of hydrants and water valves, advised before work is continued, areas, driveways and streets shall be Y !/2 " 55 -80 copper tubing complying with Federal along with any other construction changes are to D. Inactive and abandoned utilities encountered be parking P 6' material only - thoroughly compacted #4 35 -60 Specification WW -T799. Fittings shall be be incorporated on the original construction in excavating and grading operations shall granular by approved methods. Trenches parallel to and #8 25 -50 wrought copper or cast bronze with solder joints. drawings and "Record Drawing" prints shall be reported to the Engineer. They shall be within 10 feet of paved roadways shall also be #30 12 -30 Solder shall be of a composition recommended by submitted to the water utility as soon after removed, plugged or capped as directed by constructed with compacted granular material. #200 5 -10 the manufacturer of the fittings. completion of construction as possible. the Engineer. JACK'S TOOL RENTAL SITE 410 West Carmel Drive Carmel, Indiana IT I IBe, ''U��� �.,ISTO, • 4� •% O:' 1. No. z 19900113 i : STATE OF .• 0 ����ir�SS I I A?i;' •�� N ZONAL 1111111 � July 15th, 2003 Approved By. D. Scott Bordenet Dra wn By TJW Date of Last Field Work: Construction Specifications Benchmark Surveying, Inc. 9855 Crosspoint Blvd., Suite 110 Indianapolis, IN 46256 Pb. 317- 841 -1506 Fax 317 - 841 -1507 benchmarkls. com Project Description: Specifications this sheet present minimum requirements for specifications not stated elsewhere on the plans. Owner /Developer: TOOL RENTAL INC CARMEL, IN 317-691- 7278 Rev# Date Remarks 1 7115103 Added Sanitary Specs. Project 3 -248 [Jack's Tool Rental] Sheet No. : 12 of 12