HomeMy WebLinkAbout0503003.1MORTON BUILDINGS GENERAL SPECIFICATIONS LAMINATED COLUMNS - NO. 1 OR BETTER SOUTHERN YELLOW PINE NAIL LAMINATED 3 MEMBER S4S COLUMNS USED IN MORTON BUILDINGS ARE PRESSURE TREATED BELOW GRADE TO A RETENTION OF _8 POUNDS PER CUBIC FOOT WITH CHROMATED COPPER ARSENATE TYPE III, OXIDE TYPE, AS LISTED IN FEDERAL SPECIFICATION TT- W -571J. THE TREATED PORTION OF THE COLUMN EMBEDDED IN GROUND SHALL BE LAMINATED WITH STAINLESS STEEL NAILS. FOOTINGS AND ANCHORAGE - COLUMN HOLES ARE DUG 4 FEET DEEP MIN. DEPTH BELOW GRADE AND READY -MIX CONCRETE PADS OR DRY CONCRETE MIX PADS ARE POURED IN PLACE (NOTE PLANS FOR SIZE & TYPE). TWO GALVANIZED STEEL BASE ANCHORS ARE PLACED 1" FROM BOTTOM OF COLUMN OR 1/2" GALVANIZED STEEL ROD PLACED 2 1/2" FROM BOTTOM OF COLUMN.( SEE SECTION )ADDITIONAL CONCRETE IS MIX POURED AROUND BASE OF COLUMN THEN BACKFILLED WITH SOIL AND COMPACTED AT 8" INTERVALS. SPLASHBOARDS - SPLASHBOARDS ARE NO. 2 OR BETTER SOUTHERN YELLOW PINE 2 "x8" S2S AND CENTER MATCHED, PRESSURE TREATED TO NET RETENTION OF .6 POUNDS PER CUBIC FOOT WITH CHROMATED COPPER ARSENATE TYPE III, OXIDE TYPE, IN ACCORDANCE WITH AMERICAN WOOD PRESERVERS' ASSOCIATION SPECIFICATION C2, ONE ROW IS FURNISHED FOR BUILDING ON A LEVEL SITE. FRAMING LUMBER -SIDE NAILERS ARE 2 "x4" S4S OR 2 "x6" SPF NO.2 OR BETTER SPACED APPROXIMATELY 30" O.C. SHALL HAVE LESS THAN 200 FLAME SPREAD WITH ALL JOINTS STAGGERED AT ATTACHMENT TO COLUMNS. ROOF PURLINS ARE 2 "x4" S4S NO. 2 OR BETTER ON EDGE SPACED APPROXIMATELY 24" O.C. ALL OTHER FRAMING LUMBER IS NO. 2 OR BETTER. ( SEE SECTION ) ROOF TRUSSES - FACTORY ASSEMBLED WITH 18 OR 20 GAUGE GALVANIZED STEEL TRUSS PLATES AS REQUIRED AND KILN DRIED LUMBER AS SPECIFIED, IN -PLANT QUALITY CONTROL INSPECTION IS CONDUCTED UNDER THE AUSPICES OF THE TPI INSPECTION BUREAU, TRUSSES ARE DESIGNED IN ACCORDANCE WITH CURRENT STANDARDS AND SPECIFICATIONS FOR THE STATED LOADING. SIDING PANELS ( KYNAR 500 /HYLAR 5000) -0-019" MIN., G90 GALVANIZED OR AZ55 GALVALUME, WITH AN ADDITIONAL BAKED -ON KYNAR 500 /HYLAR 5000 FINISH. PAINT IS NOM. 1 MIL THICK ON EXTERIOR. ROOFING PANELS (FLUOROFLEX 2000 (TM) -0-019" MIN., AZ55 GALVALUME WITH AN ADDITIONAL BAKED -ON THICK POLYURETHANE PRIMER AND KYNAR 500 /HYLAR 5000 TOPCOAT WITH A TOTAL MINIMUM PAINT THICKNESS OF 2 MILS. TRIM -DIE-FORMED TRIM OF 0.019" MIN., G90 GALVANIZED OR AZ55 GALVALUME STEEL ON GABLES, RIDGES, CORNERS, BASE, WINDOWS, AND DOORS WITH SAME FINISH AS ROOFING OR SIDING PANELS. GUTTERS - 5" K- STYLE, .030 HIGH TENSILE ALUMINUM GUTTER, KYNAR 500 /HYLAR 5000 FINISH TO MATCH TRIM, ON BOTH SIDES OF THE BUILDING. ADDITIONAL NOTES 1.) ALL PLOT PLANS AND RELATED DETAILS SHALL BE PROVIDED BY OWNER UNLESS INCORPORATED AS PART OF THESE DRAWINGS. 2.) ALL INTERIOR PARTITIONS AND ROOM FINISHES IF NOT INCLUDED WITH THESE DRAWINGS SHALL BE PROVIDED BY OWNER, STANDARD FINISHES SHALL HAVE LESS THAN 200 FLAME SPREAD RATING AS REQUIRED BY ASTM E84 . FOR ORDINARY CONDITIONS AND 25 OR LESS FOR EXITS, PASSAGEWAYS, AND CORRIDORS. 3.) FLOOR COVERINGS JUDGED TO REPRESENT AN UNUSUAL HAZARD SHALL MEET THE SAME TESTING PROCEDURES AS REQUIRED FOR WALL AND CEILING FINISHES. 4.) MORTON BUILDINGS GENERAL SPECIFICATIONS APPLY UNLESS INDICATED DIFFERENTLY ON SPECIFIC JOB DRAWINGS OR SUPPLEMENTAL INFORMATION. 5.) KYNAR 500 IS A REGISTERED TRADEMARK OF ELF ATOCHEM NORTH AMERICA, HYLAR 5000 IS A TRADEMARK OF AUSIMONT, USA. CS2x4FK 2 -96 o go I Z)Z-v R,r4 A t 5.0 v BUILDING DESIGN CRITERIA USE GROUP 2 "x4" DESCRIPTION 1,313 PSI CONSTRUCTION TYPE 2"x6" LIVE ROOF LOAD DESIGN 1138 PSI LDING LOCATION PLAN WIND LOAD 1650 PSI 2 %M.P.H. FLOOR LOAD 2 "x10" "x12" N0. 1 SYP OR PLANS FLOOR AREA OF TYPICAL LUMBER SPECIFICATIONS - 1991 NDS SIZE DESCRIPTION MEET INDEX 2 "x4" DESCRIPTION 1,313 PSI 2' x4" nFT CIFICATIONS & SHEET INDEX 2"x6" NO,1 &2 SPF 1138 PSI LDING LOCATION PLAN NO. 1 SYP 1650 PSI 2 UMN PLAN 1500 PSI 2 "x10" "x12" N0. 1 SYP OR PLANS S3 OF S11 ACCESIBILITY REQUIREMENTS S4 OF S11 ELEVATIONS S5 OF S11 SECTIONS & DETAILS S6 OF S11 SECTIONS & DETAILS S7 OF S11 SECTIONS S8 OF S11 SECTIONS & DETAILS S9 OF S11 SECTIONS & DETAILS S10 OF S11 FLOOR JOIST LAYOUT & DETAILS S11 OF S11 TRUSS DRAWING TYPICAL LUMBER SPECIFICATIONS - 1991 NDS SIZE DESCRIPTION BENDING VALUE Fb 2 "x4" NO.1 &2 SPF 1,313 PSI 2' x4" 2100f MSR SPF 2100 PSI 2"x6" NO,1 &2 SPF 1138 PSI 2"x6" "x8" NO. 1 SYP 1650 PSI 2 NO. 1 SYP 1500 PSI 2 "x10" "x12" N0. 1 SYP 1300 PSI 2 NO. 1 SYP 1250 PSI ALL 1950f MSR SYP 1950 PSI 1 1 2 "x16" "x15" LAMINATED VENEER LUMBER 2800 PSI 3 1 2 GLU -LAM 1650 PSI 5 1 4 x16 1 2' GLU -LAM 2400 PSI 5 1 4 x19 1 2" GL_I-LAM 2400 PSI I ur- r_rr, UMMUL MA I tNIAL KEQUIRED AS NOTED ON PLANS, I HEREBY CERTIFY THAT THE STRUCTURAL DESIGN FOR THIS BUILDING WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY REGISTEF PROFESSIONAL ENGINEER. _ _ .z RONALD L. SUTTON, MICHAEL L. McCORt DATE:lcS Ts p n 9600100 STATE-01- 010 I HEREBY CERTIFY THAT THE ARCHITECTURAL DESI ,s�xW"w' ; "um,+�ul FOR THIS BUILDING WAS PREPARED BY ME OR U *�,.W:,.Noi; MY DIRECT SUPERVISIO ND THAT I AM A DU`P�" ".DNS z. LICENSED ARCHITECT. �O f W o. $800'8 WAYNE NOWLAN, ARC -11T - CT$SAT9 OF DATE: rr REG. c� OFFICE: RUSHVILLE, INDIANA JO NO. 35 2 K z' w w W 0 C v 0 E 0 U U Z drN V) cm z 0 J m z O r P ® C 'o m 0 �.r DRAWN BY: 875 DRF DATE: 10 -11 -99 CHECKED BY: TED F. DATE: 10-18-99 REVISED DATE: REVISED DATE: REVISED DATE: REVISED DATE: g SCALE: SHEET NO. T1 of T2