Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
05020034-35.5
12� N 0 O w o CD w o O W N U � z � w z rr- w O Cf� z I I a (D of NI I _I o� I ® � I I W � I o I I N I I I I I C� Sanitary Sewer I � Carmel City Sewer and Water I 0 760 Third Avenue S.W. 760 Third Avenue S.W. NI I Carmel, Indiana 46032 Carmel, Indiana 46032 12s z 317— 571 —2648 317 - 776 -5534 Q� Cable Electric SBC Bright House Networks Indpls. Power and Light Co. F-- -n 516 East Carmel Drive 2102 North Illinios Street O 0-) Carmel, Indiana 46032 Indianapolis, Indiana 46202 317- 265 -4878 317-972-9700 317- 261 -8406 New Fire Hydrant Existing Water Valve — u New Water Valve W Existing Fiberoptic Line - - Existing Gas Main LLi CD II 3 r VC Existing Telephone Line ® 0.45% New Gas Main I( !426 T New Telephone Line Existing Utility Pole Existing Trees � II W CD III h � III h � III II � III Q II I II � III � III W II I II III II III II III N III II ul II III II III � III ll I III II III � III II ill N II II B II II II II II� II II I II II 100.0' I II RIG IT OF WAY II II III II �� II II II p I II EXISTING FIRE HYDRANT MAIN STREET WES1 3 2 LPIJ - \I ■ 11 1 ■ ■e ■ • �I m Irnu W T Z1111 264' of 8" PVC 0 0.45% 2 ( WEST 131st STREET ) 12" RCP SSD _— T_ —__- -SSD - - -- I X0 9 MENEM COLUMN SSD SSD 118 SSD 285' of 8' PVC 0 0.45% � PUBLIC STREET N „9 — 18_RCP 109 12 " RCP SSD____ _____ SSD X RY SIGN COLUMN � \ 1 � I I � U 402 ORIGINATING BM — IN HAMILTON COUNTY, CARMEL QUADRANGLE, NORTHWEST QUARTER OF SECTION 26, T. 18 N., R. 3 E., DNR BRONZE DISK STAMPED "HAM 61 1989 ", AT THE SOUTHEAST HEADWALL OF SPRING MILL ROAD BRIDGE OVER WILLIAMS CREEK, SET IN THE TOP OF THE SOUTHEAST CONCRETE WINGWALL OF THE BRIDGE. 14 FEET EAST FROM THE CENTERLINE OF SPRING MILL ROAD, 0.6 FEET SOUTHWEST FROM THE NORTHEAST FACE OF THE WINGWALL, 0.3 FEET BELOW THE ROADWAY. ELEVATION = 864.794 (NGVD 1929) BM — MINE SPIKE IN EAST SIDE OF A 48" OAK, 1' UP AT THE NW CORNER OF 131st ST AND MERIDIAN CORNERS BLVD. ELEVATION = 873.17 TBM 1 — 5/8 INCH REBAR AT NW COR. OF SE QTR. OF SEC. 26- 18N -03E ELEVATION = 874.83 TBM 2 — SOUTH BOLT, TOP OF FLANGE OF FIRE HYDRANT ON N. SIDE OF 131st STREET APPROXIMATELY 40 FT EAST OF WEST LINE OF 5 ACRE SITE ELEVATION = 870.78 PON MARBURGF NSTRUMENT #960962_6E49 RON MARBURGER "ALSO" TRACT INSTRUMENT #9609626849 ROXAr�NE BELLINGER, TRUSTEE OF THE BELLINGER FAMILY REVOCABLE TRUST INSTRUMENT #9709756151 Indiana Underground Utility Location Service (1- 800 - 382 -5544) was contacted for marking of utilities Water Sanitary Sewer Gas Carmel City Sewer and Water Carmel City Sewer and Water Vectren Energy Delivery 760 Third Avenue S.W. 760 Third Avenue S.W. P.O. Box 1700 Carmel, Indiana 46032 Carmel, Indiana 46032 Noblesville, Indiana 46061 317 - 571 -2648 317— 571 —2648 317 - 776 -5534 Telephone Cable Electric SBC Bright House Networks Indpls. Power and Light Co. 220 North Meridian Street 516 East Carmel Drive 2102 North Illinios Street Indianapolis. Indiana 46204 Carmel, Indiana 46032 Indianapolis, Indiana 46202 317- 265 -4878 317-972-9700 317- 261 -8406 Utility Hotline: within Indiana 1- 800 - 382 -5544 outside Indiana 1- 800 - 428 -5200 Note The nature, size and location of utilities are per plans and locations provided by the respective utility companies. The above list constitutes some, if not all, of the utility companies which may provide service in the area of, and adjacent to, the subject project, based upon the information available through such plans and locations, and any incidental visual inspection. All utility companies should be notified prior to any excavation for field location of services and verification of size and nature of services. 1L 1L 1L J V 1. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTAINING TO THE PHASE OF WORK. IT SHALL ALSO BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF THE VARIOUS UTILITIES FOR PROPER STAKE LOCATION OF EACH UTILITY BEFORE WORK IS STARTED. THE CONTRACTOR SHALL NOTIFY IN WRITING THE OWNER AND THE ENGINEER OF ANY CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE PLANS OR IN THE FIELD BEFORE WORK IS STARTED OR RESUMED. 2. STANDARD SPECIFICATIONS FOR THE CITY OF CARMEL SHALL APPLY FOR ALL SANITARY SEWERS AND STORM SEWERS. 3. ANY PART OF THE SANITARY OR STORM SEWER TRENCHES RUNNING UNDER PAVED AREAS TO BE BACKFILLED WITH GRANULAR MATERIAL. 4. THE SIZE AND LOCATION OF EXISTING UTILITIES SHOWN ARE PER INFORMATION PROVIDED BY THE RESPECTIVE UTILITY COMPANIES. ALL UTILITY COMPANIES SHOULD BE NOTIFIED PRIOR TO ANY EXCAVATION FOR FIELD LOCATION OF SERVICES. 5. WATER SERVICE LINE TO INDIVIDUAL UNITS SHALL HAVE A SHUTOFF VALVE IN AN ACCESSIBLE LOCATION OUTSIDE OF THE BUILDING. 6. CONTRACTOR TO CONTACT Vectren Energy Delivery FOR GAS CONNECTION TO MAIN. MAIN CONNECTION LOCATION IS TO BE COORDINATED WITH GAS COMPANY (776- 5534). 7. WATER METER PIT LOCATIONS TO BE DETERMINED BY LOCAL WATER COMPANY. 8. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE O.S.H.A. STANDARDS FOR WORKER SAFETY. 9. THERE ARE NO DRINKING WATER WELLS WITHIN A 100' RADIUS OF ANY GRAVITY SANITARY SEWER LINES OR MANHOLES ON THIS PROJECT. ON ASSUMED NORTH SCALE: 1 "= 40 ' HOLEY MOLEY SAYS DON'T DIG BLIND i "IT'S THE LAW" CALL 2 WORKING DAYS BEFORE YOU DIG 1- 800 - 382 -5544 CALL TOLL FREE PER INDIANA STATE LAW IS -69 -1991. IT IS .AGAINST THE LAW TO EXCAVATE WITHOUF NOTIFYING THE UNDERGROUND LOCATION SERVICE TWO (2) WORKING DAYS BEFORE COMMENCING WORK. 1LIE(aIET_114= PROJECT NO.: Existing Sanitary Sewer 5200.001 Existing Storm Sewer — n New Storm Sewer JES New Sanitary Sewer UTILITY (Laterals are shown for reference only) 0 C.D. Sanitary Sewer clean —out SSD Subsurface Drain (sso) 00o Storm Structure Number 00o Sanitary Structure Number � Utility & Drainage Esmt. Building Setback Line Existing Water Main W W — New Water Main Existing Fire Hydrant New Fire Hydrant Existing Water Valve N New Water Valve F--r —� Existing Fiberoptic Line - - Existing Gas Main - - - Existing Electric Line - - - Existing Telephone Line G New Gas Main E New Electric Line T New Telephone Line Existing Utility Pole Existing Trees SEE PLUMBING PLAN /ELECTRICAL PLANS FOR EXACT LOCATIONS, INVERTS, AND SIZES OF UTILITIES AT THE BUILDING. CL ,17 -- - - -- SSD --- - - - - -- —SSD - - -- j8 24" RCP 2" RCP I 6 66 6 64 6 DEEDRAH PETERSON 862 „6 861 106 �� INSTRU ,,ENT #200200070561 862 861 I 865 864 86 � I 868867 66 51' of 15" RCP 869 371' of 15" RCP ,OS 104 JOYCE WALLS INSTRUMENT #9909941491 b o Q 0 355' of 15" RCP 102 cvi z O w IN D, \v�P s T N o.10100357 CL_ STATE OF�ti ON�gt 111 1111 DA 02/18/05 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF THE SCHNEIDER CORPORATION, AND ARE NOT TO BE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF THE SCHNEIDER CORPORATION. © COPYRIGHTED BY THE SCHNEIDER CORP. (2005) f4lalo Schneider THE SCHNEIDER CORPORATION Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216 -1037 Telephone: 317.826.7100 Fax: 317.826.7200 www.schneidercorp.com Architecture Civil Engineering Environmental Engineering Geotechnical Services GIS * LIS Home Builder Services Interior Design Land Surveying Landscape Architecture Transportation Engineering W PROJECT NO.: 02/18/05 5200.001 Q CHECKED BY: I� JES SHEET TITLE: UTILITY PLAN DRAWING FILES: S: \5k \5200 \001 \dwgs \C103.dwg REF: R: \5k \5200 \001 \dwgs \TiitIe1.dwg REF: R: \5k \5200 \001 \dwgs \5200001sdwg XREF: R: \5k \5200 \001 \dwgs \001bs.dwg W z w Q � a � F--r —� 0 CD a HL1 r-, DATE: PROJECT NO.: 02/18/05 5200.001 DRAWN BY: CHECKED BY: RDR JES SHEET TITLE: UTILITY PLAN DRAWING FILES: S: \5k \5200 \001 \dwgs \C103.dwg REF: R: \5k \5200 \001 \dwgs \TiitIe1.dwg REF: R: \5k \5200 \001 \dwgs \5200001sdwg XREF: R: \5k \5200 \001 \dwgs \001bs.dwg XREF: R: \5k \5200 \001 \dwgs \utility2.dwg XREF: R: \5k \5200\ 001 \dwgs \FromCripe \011305 \sbO20350.dwg SHEET NO.: (93