Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
05030006.2
J J �o W W W W Z O z� I— Z 0 r)" O II I (II Ill I I III I I I i I I I I II I I I � II I I I I III II M I III I I II FOR CONTINUATION SEE SHEET C104 BLOCK "D" II stcl a y HOUSING — I Tv v ��1� cv O U 907.4 W w r� °° GLEBE STREET 13 Lw + 0 0 _ 906.57 905.88 905.18 z 00 B A O z 907.4 10'DU &SE � 12 B PAD 907.7— — — — PAD 907.0 O BLO aK K N O w w 0 ssD 0 12' ALLEY ESMT ALLEY PRIVATE 12' A- TIT 11111 BLOCK V i P%L� HOLEY MOLEY SAYS "DON'T DIG BLIND CALL IT'S WORKING THE BEFORE YOG 1- 800 - 382 -5544 CALL TOLL FREE PER INDIANA STATE LAW IS -69 -1991. IT IS AGAINST THE L TO EXCAVATE ASSUMED NORTH WITHOUT NOTIFYING THE UNDERGROUND if I LOCATION SERVICE TWO (2) WORKING SCALE: 1 = 50 DAYS BEFORE COMMENCING WORK. 1. ALL GRADES AT BOUNDARY SHALL MEET EXISTING GRADES. 2. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTAINING TO HIS PHASE OF WORK. IT SHALL ALSO BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF THE VARIOUS UTILITIES FOR PROPER STAKE LOCATIONS FOR EACH UTILITY BEFORE WORK IS STARTED. THE CONTRACTOR SHALL NOTIFY IN WRITING THE OWNER OR THE ENGINEER OF ANY CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE PLANS OR IN THE FIELD BEFORE WORK IS STARTED OR RESUMED. 3. STANDARD SPECIFICATIONS FOR THE HAMILTON COUNTY SURVEYOR SHALL APPLY FOR ALL STORM SEWERS. 4. THE SIZE AND LOCATION OF EXISTING UTILITIES SHOWN ARE PER INFORMATION PROVIDED BY THE RESPECTIVE UTILITY COMPANIES. ALL UTILITY COMPANIES SHOULD BE NOTIFIED PRIOR TO ANY EXCAVATION FOR FIELD LOCATION OF SERVICES. 5. SERVICE WALKS SHALL BE NON- REINFORCED CONCRETE 4" THICK AND 4' IN WIDTH. 6. 4' CONCRETE SERVICE WALK ACROSS FRONTAGE OF EACH LOT TO BE CONSTRUCTED BY OTHERS. 7. EXPANSION JOINTS AREA TO BE PLACED AT ALL WALK INTERSECTIONS AND BETWEEN WALKS AND PLATFORMS. SIDEWALK SCORES ARE TO BE EQUALLY SPACED BETWEEN EXPANSION JOINTS, CONTRAC11ON JOINTS AND PERPENDICULAR TO SIDEWALKS AT 5' INTERVALS OR LESS WITH A CONTRACTION JOINT EVERY 20' OR LESS. 8. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 9. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE O.S.H.A. STANDARDS FOR WORKER SAFETY. 10. CONTRACTOR SHALL MINIMIZE DAMAGE TO EXISTING TREES. 11. REMOVE AND BACKFILL ALL AREAS WHERE ANY FIELD TILE CROSSES PROPOSED HOUSE PADS. ALL FIELD TTLES INTERCEPTED TO BE PERPETUATED INTO STORM SEWER SYSTEM OR LAKE. THE SUBCONTRACTOR SHALL NOTIFY IN WRITING THE OWNER AND THE ENGINEER IN ANY CIRCUMSTANCES WHERE THIS CANNOT BE ACCOMPLISHED, 12. ALL FILL AREAS (ENGINEERED FILL) SHALL BE COMPACTED TO AT LEAST 95 PERCENT OF THE MAXIMUM DRY DENSITY (ASTM D- 1557). FILL UNDER THE FOOTING SHALL BE COMPACTED TO AT LEAST 95 PERCENT OF THE MAXIMUM DRY DENSITY (ASTM D- 1557). FILL SHOULD EXHIBIT A MAXIMUM DRY DENSITY OF AT LEAST 105 PCF, AND HAVE A LIQUID LIMIT LESS THAN `,0 AND PLASTICITY INDEX OF LESS THAN 25. SANDY FILL MUST HAVE LESS THAN 15 PASSING A #200 SIEVE. 13, WATERMAIN VALVES SHALL NOT BE LOCATED UNDER PAVEMENT, SIDEWALK OR CURB. 14. 100 YEAR FLOODPLAINS, FLOODWAY FRINGES AND FLOODWAYS: NONE NOTE: NO KNOWN PUBLIC WATER SYSTEMS WITHIN 50' OF PROPOSED SANITARY SEWERS. NO F.E.M.A. OR D.N.R. MAPPED 100 YEAR FLOODWAY OR FLOODPLAIN PER HAMILTON COUNTY, IN, MAP NUMBER 18057CO2026F. CLAY TOWNSHIP REGIONAL WASTE DISTRICT SANITARY SEWER STRUCTURE NUMBER PREFIX: VWC —W -000 (Village of WestClay — West— Structure number) Z 0 cn w \STERF No. 10000075 -;0 STATE OF %0, /NDIANP s /ON AILIII DATE: 3/1/05 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF THE SCHNEIDER CORPORATION, AND ARE NOT TO BE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF THE SCHNEIDER CORPORATION. © COPYRIGHTED BY THE SCHNEIDER CORP. (2005) IC44001 Schneider THE SCHNEIDER CORPORATION 12821 E. New Market Street Suite 100 Carmel, IN 46032 Telephone: 317.569.8112 Fax: 317.826.6410 www.schneidercorp.com Architecture Civil Engineering Environmental Engineering Geotechnical Services GIS * LIS Home Builder Services Interior Design Land Surveying Landscape Architecture Transportation Engineering Existing Storm Sewer — —�— New Storm Sewer DRAWN BY: Existing Sanitary Sewer DCC New Sanitary Sewer o - Existing Contour DRAWING FILES: Existing Elevation 000.00 New Pavement Grade FOO-0-0-01 All Other Finish Grades ICE Match Existing Grades DDD Storm Structure Number 0 Sanitary Structure Number w Flow Arrow 4� -------- - - - - -- 6' Subsurface Drain - -- 4' SSD Lot Lateral 000.00 • Swale (0 w Water Main Existing Trees Existing Gas Main a Existing Telephone Existing Water Main Existing Flowline Existing Overhead Utilities 12' Alley (Private Alley Easement) MFFE Minimum Finished Floor Elevation 1' Above Hightest Lot Grade O 2' Chairback Curb with Gutter 0 2' Chairback Curb w/o Gutter O 2' Valley Gutter NOTE: NO KNOWN PUBLIC WATER SYSTEMS WITHIN 50' OF PROPOSED SANITARY SEWERS. NO F.E.M.A. OR D.N.R. MAPPED 100 YEAR FLOODWAY OR FLOODPLAIN PER HAMILTON COUNTY, IN, MAP NUMBER 18057CO2026F. CLAY TOWNSHIP REGIONAL WASTE DISTRICT SANITARY SEWER STRUCTURE NUMBER PREFIX: VWC —W -000 (Village of WestClay — West— Structure number) Z 0 cn w \STERF No. 10000075 -;0 STATE OF %0, /NDIANP s /ON AILIII DATE: 3/1/05 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF THE SCHNEIDER CORPORATION, AND ARE NOT TO BE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF THE SCHNEIDER CORPORATION. © COPYRIGHTED BY THE SCHNEIDER CORP. (2005) IC44001 Schneider THE SCHNEIDER CORPORATION 12821 E. New Market Street Suite 100 Carmel, IN 46032 Telephone: 317.569.8112 Fax: 317.826.6410 www.schneidercorp.com Architecture Civil Engineering Environmental Engineering Geotechnical Services GIS * LIS Home Builder Services Interior Design Land Surveying Landscape Architecture Transportation Engineering DATE: PROJECT NO.: 311105 1238.6001 DRAWN BY: CI DCC o DEVELOPMENT PLAN DRAWING FILES: N: \1238 \6001 \DWGS \C101- 102.DWG XREF: 6001- BS.DWG, 6002- BS.DWG XREF: 6003- BS.DWG, PINCLNEY.DWG XREF: 5003- BS.DWG, 8002BS.DWG O XREF: CA2I.DWG, CA12.DWG, CA9.DWG H (C ROR O w 4� CO a Z o z a z � W z c r---Ti pq DATE: PROJECT NO.: 311105 1238.6001 DRAWN BY: CHECKED BY: DCC SHEET TITLE: DEVELOPMENT PLAN DRAWING FILES: N: \1238 \6001 \DWGS \C101- 102.DWG XREF: 6001- BS.DWG, 6002- BS.DWG XREF: 6003- BS.DWG, PINCLNEY.DWG XREF: 5003- BS.DWG, 8002BS.DWG XREF: 8501BS.DWG, GLEBE- BS.DWG XREF: CA2I.DWG, CA12.DWG, CA9.DWG SHEET NO.: (C ROR