HomeMy WebLinkAbout05040003.18�1 K J H G F C C A A 2 3 4 5 1 2 3 1 4 5 6 7 STANDARD HYDRANT SETTING: INSTALL HYDRANT 3' FROM RIGHT -OF -WAY LINE OR AS APPROVED BY WATER COMPANY. 1' -6" MIN. TO SET TOP FLUSH WITH 2' -0" MAX. FINISHED GRADE TO BE MARKED "WATER ". / 3 -PIECE ADJUSTABLE VALVE BOX SUPPORT VALVE BOX WITH BRICK OR BLOCK ON UNDISTURBED EARTH VALVE FLANGED TO FITTINGS GATE VALVE PER AWWA C500 TO OPEN COUNTER CLOCKWISE 7 s 12 NOT LESS THAN 0.6 x LAYING LENGTH // 4V UNDISTURBED EARTH OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE FOR 22 1/2' AND 11 1/4' BENDS PLAN STRAP IRON AN-''--- 2" WIDE x 1/2* 2,000 LB. MIN. CONCRETE UNDISTURBED EARTH 5" DIA. WASHER, 1- THICK 3/4" x 18" ANCHOR BOLTS (4 REQ'D) DOWNWARD BEND 13 NOT LESS THAN 0.75 x LAYING LENGTH OWN =0641 001 UNDISTURBED \ �\ EARTH OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE FOR 90' AND 45' BENDS PLAN NOTE: ALL PRIVATE FIRE HYDRANTS TO BE PAINTED RED. BREAKAWAY HYDRANT THREADS TO MATCH LOCAL FIRE DEPARTMENT EQUIPMENT PUMPER CONNECTION TO FACE TOWARD PAVEMENT FINISHED GRADE 6" NOMINAL BARREL MIN. 1 CU YD. LOOSE STONE OR GRAVEL FOR DRAINAGE. (6" ABOVE PORTS) DO NOT USE CRUSHED LIMESTONE. CONCRETE THRUST BLOCK NOT TO COVER JOINTS OR DRIP HOLE REQUIRED ON 10" AND LARGER MAINS. O� o a - ° a a o 0 iv \_DI ANCHORING COUPLING NOTE: PROVIDE FIRE HYDRANTS WITH TWO (2) CONCRETE THRUST BLOCK 2 1/2-INCH AND ONE (1) 4 1/2-INCH DIAMETER ON UNDISTURBED EARTH OUTLETS. ALL OUTLETS WILL HAVE NATIONAL STANDARD THREADS. HYDRANT DETAIL o4 NOT TO SCALE C7.2 8 9� www.civil- designs.com i 4" MIN. 2 3" MIN. \ �1 2,000 LB. MIN. CONCRETE \ a 12r O PIPE O.D. MIN UNDISTURBED EARTH 6" MIN. OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE. SECTION "C -C" BLOCKING FOR PLUGS AND BENDS PIPE SIZE OUTSIDE FACE AREA (SQ. FT. PLUG 90' 1 45' 22 1/2' 11 1 20 16 25 14 7 4 16 12 16 9 5 3 12" 7 9 5 3 2 10" 4 7 4 1 2 1 8" 3 5 3 2 1 6" 2 3 2 1 1 4" 1 2 3 1 2 1 1 14 15 12" N - - ° ��, —OUTSIDE FACE AREA NOT LESS THAN ° — VALUES GIVEN IN TABLE FOR 90' / \\ //\ \ \ UNDISTURBED EARTH „C„ 2,000 LB. MIN. CONCRETE OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE FOR TEES PLAN AND WYES 2 21 4" MIN. 1 U LLJ Q �' a - 2,000 LB. MIN. 0 rn O Q uj CONCRETE W � 3; a a �\ ILL U = a DATE: 3 118-17005 a PROJECT NUMBER CHKD. BY: ACH \ // \ / / / / SCALE: NTS \\ DATE: 3/18/2005 C7m2 UNDISTURBED EARTH OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE FOR PLUGS. SECTION "D -D" WATER MAIN - CONCRETE BLOCKING O1 NOT TO SCALE C .2 HEAVY DUTY LAMPHOLE CASTING W/ SOLID LID, NEENAH R -1974 OR EQUAL CONCRETE COLLAR- ) COMPACT IL BAC FOLL \ \// #$ COMPACTED STONE --\ 3'- 0" MAX. WYE 45' BEND NOTE: MAXIMUM CLEANOUT SPACING TO BE NO MORE THAN 100 FEET. CLEANOUT DETAIL o2 NOT TO SCALE C7.2 NOTE: SUPPORT VALVE BOX WITH BRICK OR BLOCK ON UNDISTURBED EARTH a FINISH FLOOR 4' MIN. SEE UTILITY PLAN FOR INVERTS FLEXIBLE PIPE SLEEVE SET TOP FLUSH WITH FINISHED GRADE. TO BE MARKED "WATER" 3 -PIECE ADJUSTABLE VALVE BOX & SLEEVE o w WATER MAIN VALVE FLANGED TO FITTINGS �� \\L CONCRETE THRUST BLOCK GATE VALVE PER AWWA C500 ON UNDISTURBED EARTH TO OPEN COUNTER CLOCKWISE GATE VALVE AND B_ OX o3 NOT TO SCALE C7.2 12 13 4 w 0- N Q 5 16 V Civil Designs 2415 Directors Row Ste.E Indianapolis, In 46241 317 - 244 -1968 FAX- 244 -1969 Z 0 W pC z ( IN FEET ) 1 inch = ft. (ASSUMED NORTH) U LLJ Q �' REVISION RECORD v 0 i—�z 0 rn O Q uj uj W � 3; v ILL U = 0 N C. /y �� P;�� \STFR�.•���� • No .� : PE10300058 STATE OF oX, ANP.G , \���,, ',� 111 1 W %��,� Rw,,c,, C. H J DATE: 3 118-17005 DWN BY: - - -,JRD PROJECT NUMBER CHKD. BY: ACH SCALE: NTS CONSTRUCTION DATE: 3/18/2005 V Civil Designs 2415 Directors Row Ste.E Indianapolis, In 46241 317 - 244 -1968 FAX- 244 -1969 Z W pC z Q U LLJ Q �' W v 0 i—�z 0 rn Q uj uj W � 3; v ILL U = Vi PROJECT NUMBER 05 -110 DESIGN PHASE CONSTRUCTION PLAN NUMBER C7m2 SHEET OF