HomeMy WebLinkAbout05050046.2L
.o
a
�o
O
N
IN
rn
in
O
O
N
00
in
0
J
of
v
c
a�
E
n
C
0
0
O
N
C1
Ln
Lf1
V)
LEGEND
EXISTING EDGE OF WOODS
EXISTING CONTOUR
EXISTING SANITARY SEWER
EXISTING STORM SEWER
848.0 PROPOSED GRADE
IMM-11 MATCH EXISTING
670 PROPOSED CONTOUR
PROPOSED SANITARY SEWER
-�- - PROPOSED STORM SEWER
<000 PROPOSED SWALE
NOTE:
ALL OFF -SITE DRAIN TILES SHALL BE TIED INTO THE
PROPOSED STORM SYSTEM OF THIS SECTION (WHERE APPLICABLE)
NOTE: DECORATIVE SIGNS, SPRINKLER SYSTEMS, TREES,
LANDSCAPING MOUNDS, LIGHT POLES, OR OTHER SUCH
AMENITIES ARE NOT PERMITTED IN THE RIGHT OF WAY.
ALL PADS SHOULD BE TESTED TO ASSURE
A COMPACTION OF AT LEAST 95% OF THE
MAXIMUM DRY DENSITY USING THE STANDARD
It PROCTOR TEST METHOD.
NOTE:
A KNOX BOX IS TO BE INSTALLED
AT THE PAVILLION. CONTACT FIRE
CHIEF FOR EXACT LOCATION.
EARTHWORK:
1. EXCAVATION
A. Excavated material that is suitable (topsoil and /or clay) may be used for fills. All unsuitable material and all surplus
excavated material not required shall be removed from the site.
B. Provide and place any additional fill material from offsite as may be necessary to produce the grades
required on plans. Fill obtained from offsite shall be of quality as specified for fills herein and the
source approved by the Developer. It will be the responsibility of the Contractor for any costs for
fill needed.
2. REMOVAL OF TREES
A. All trees and stumps shall be removed from areas to be occupied by a road surface or
structure area. Trees and stumps shall not be buried on site.
3. PROTECTION OF TREES
A. The Contractor shall, at the direction of the Developer, endeavor to save and protect trees of value
and worth which do not impair construction of improvements as designed.
B. In the event cut or fill exceeds 0.5 foot over the root area, the Developer shall be consulted with
respect to protective measure to be taken, if any, to preserve such trees.
4. REMOVAL OF TOPSOIL
A. All topsoil shall be removed from all areas beneath future pavements or building. Topsoil removal shall
be to a minimum depth of 6 inches or to the depth indicated in the geotechmical report provided by the
Developer to be excavated or filled. Topsoil should be stored at a location where it will not interfere
with construction operations. The topsoil shall be free of debris and stones.
5. UTILITIES
A. Rules and regulation governing the respective utility shall be observed in executing all work under
this section.
B. It shall be the responsibility of the Contractor to determine the location of existing underground
utilities 2 working days prior to commencing work. For utility locations to be marked call Toll Free
1- 800 - 382 -5544 within Indiana or 1 -800- 428 -5200 outside Indiana.
C. Contact Carmel Utilities at 571 -2648 for location of all watermains.
6. SITE GRADING
A. Do all cutting, filling, compacting of fills and rough grading required to bring entire project area
to subgrade as shown on the drawing.
B. The tolerance for paved areas shall not exceed 0.05 feet above established subgrade. All other areas
shall not exceed 0.05 feet plus or minus the established grade. Provide roundings at top and bottom
of banks and other breaks in grade.
C. The Engineer shall be notified when the Contractor has reached the tolerance as stated above, so
that field measurements and spot elevations can be verified by the Engineer. The Contractor shall
not remove his equipment from the site until the Engineer has verified that the job meets the above
tolerance.
FORM \EARTHWRK
EX `ON 2
SECS
EX. EX.
EX.
917.30
c�
c� X X
�o 7 BABY �-�-► 919.5 N
P00L X X �o
28, 17 X- 0
6 P�� 8 919.5 15 30
42'
J
10 XCD
�1,6 I X POOL v�
17.07'
ry 17'
CD
Cyl 0 i5 5
EQ.RM. �o X X
cal
n X -P X
Oo BI E RACK
m cn X 919.0 X U? 918.5 X co
CD - X 7.
X rn ' 917.35 X 918.0
H K a m 15' R
724 c , CD 34.07' X X
52' L.F. OF 5'R
LO C)O o iv co 00
VALLEY CURB < oo • 17.23 u, o
91 .90
`SO X � 1916.74 �O
E X. E X. °� �° co J 5 �
915.8 X X916.21 - 916.37 916.50 �1) X ��o f
16.29 -� 46
NOTE TO CONTRACTOR:
CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION
TO CONFIRM THERE IS NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS.
CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY.
QD P
O X 9�� 916.7 4 .90 Q�
� 17.23
�Ib 9 C
CO rn Co o YP . 5'R
15' R a� 6, N c� U,� E X.
x� 00 00 918.0 X__ 16 7
J P, X + 1 7
0, 00
15' R.D.E. iw
916.20 - 917.20
EX. EX. EX. EX. 164
16:5
20' -0'
2' ROLL CURB
24' -0"
12' -0"
12' -0"
;y8 AGGREGATE -IN.
E�4
8" S.S.D.
4 I "6'q"-
TYPICAL DRIVEWAY CROSS- SECTION
1" H.A.C. SURFACE #11
5" H.A.C. BINDER #5D
7" COMPACTED STONE #53
COMPACTED SUBGRADE
PAVEMENT COMPOSITIONS
NOT -TO -SCALE
M
TOP OF CURB
PAVEMENT BOTTOM OF CURB
TRANSvERSE EXPANSION JOINTS TRANSVERSE CONTRACTION JOINTS
" "' WHEN BUILT IN CONJUCTION WITH CONCRETE PAVEMENT, EXPANSION
ANO SONTRACTION JOINTS SHOULD BE PLACED AT THE SAME
LOCATIONS AS IN THE PAVEMENT SLABS. THE CURB AND GUTTER
SHOULD BE TIED TO THE PAVEMENT BY 1/2" ROUND DEFORMED BARS
AT ABOUT 3 FOOT INTERVALS. IF NO CONCRETE PAVEMENT IS BEING
BUILT AT THE TIME THE CURB IS CONSTRUCTED, EXPANSION JOINTS
SHOULD BE PLACED AT THE ENDS OF ALL RETURNS AND AT
INTERVALS NOT TO EXCEED 100 FEET. CONTRACTION JOINTS SHOULD
BE INSTALLED AT 20 FOOT SPACING.
CURB JOINT DETAIL
NOTE:
ALL PAVING IS TO BE COMPLETED
IN ONE PAVING SEASON.
Ii
COMPACTED
2' ROLL CURB
4.5"
GUTTER IN CURB
CTED SUBGRADE
CONCRETE ROLL CURB NO GUTTER
(TYPE 1)
EX. LAKE #3
N P,-= 911 50
2 YEAR ELEV. = 912.46
10 YEAR ELEV. = 91 3.23
100 YEAR E EV. = 914, 35
BOTTOM ELEV 90 ,3° 50
C.A. #7
VAR. D.U.&S.S.E. &
LM.A.E.
"HOLEY MOLEY"
SAYS:
- 800 - 382 -5544
CALL TOLL FREE
1- 800 - 428 -5200
FOR CALLS OUTSIDE OF INDIANA
OFFICE OF THE HAMILTON COUNTY SURVEYOR
..
11(311 -111 -1 I 1�111_l�
-III -111 I- IB III -W
=1
I I- I I -I I'- III - III - III - III -I i 1- 111 -I I I
UNDERDRAINS REQUIRED IN SWALES WITH LESS THAN I/ SLOPE
Z 0
LLJ
>
0-)
-zj-
03
TYPICAL SWALE DETAIL
°OFFICE��
HAMILTON COUNTY SURVEYOR'S
•
KALE: 1"= 20' '���►nlilt'
APPROVED t w ° v r°v
STANDARD PLAN
D -1B
EX. LAKE #3
N P,-= 911 50
2 YEAR ELEV. = 912.46
10 YEAR ELEV. = 91 3.23
100 YEAR E EV. = 914, 35
BOTTOM ELEV 90 ,3° 50
C.A. #7
VAR. D.U.&S.S.E. &
LM.A.E.
"HOLEY MOLEY"
SAYS:
- 800 - 382 -5544
CALL TOLL FREE
1- 800 - 428 -5200
FOR CALLS OUTSIDE OF INDIANA
CAUTION
LOCATION OF ALL EXISTING UNDERGROUND
UTILITIES SHOWN ON THIS PLAN ARE BASED
UPON ABOVE GROUND EVIDENCE. (including,
but not limited to, manholes, inlets, valves, &
marks made upon the ground by others.) AND
ARE SPECULATIVE IN NATURE. THERE MAY ALSO
BE OTHER EXISITING UNDERGROUND UTILITIES
FOR WHICH THERE IS NO ABOVE GROUND
EVIDENCE OR FOR WHICH NO ABOVE GROUND
EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS
OF SAID EXISTING UNDERGROUND UTILITIES
SHOULD BE VERIFIED BY THE CONTRACTOR
PRIOR TO ANY AND ALL CONSTRUCTION.
CONTACT: CARMEL UTILITIES
(317) 571 -2648
FOR WATER LOCATES
m
Z
0
Cn
LLJ
X
of
Q
LLJ
F_
Q
0
Ln
° °
Q
o U lw LJ u') o
° \
Ln
Ln
0
0
Ln
0
LLJ
f-
v
�
%��d........
..
o
LC)
--A
WZ o'
Z 0
LLJ
>
0-)
-zj-
03
CY-
•
KALE: 1"= 20' '���►nlilt'
CAUTION
LOCATION OF ALL EXISTING UNDERGROUND
UTILITIES SHOWN ON THIS PLAN ARE BASED
UPON ABOVE GROUND EVIDENCE. (including,
but not limited to, manholes, inlets, valves, &
marks made upon the ground by others.) AND
ARE SPECULATIVE IN NATURE. THERE MAY ALSO
BE OTHER EXISITING UNDERGROUND UTILITIES
FOR WHICH THERE IS NO ABOVE GROUND
EVIDENCE OR FOR WHICH NO ABOVE GROUND
EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS
OF SAID EXISTING UNDERGROUND UTILITIES
SHOULD BE VERIFIED BY THE CONTRACTOR
PRIOR TO ANY AND ALL CONSTRUCTION.
CONTACT: CARMEL UTILITIES
(317) 571 -2648
FOR WATER LOCATES
m
Z
0
Cn
LLJ
X
of
Q
LLJ
F_
Q
0
Ln
° °
Q
o U lw LJ u') o
° \
Ln
Ln
0
0
Ln
0
LLJ
f-
v
�
Q
0
LC)
°z
0-
Z 0
LLJ
>
0-)
-zj-
03
CY-
0
X
z
Q
Q
J
I
�
CD
V)
O
I
w
I
0
C�
00
z
LLJ
0
Ln
Z
J
o�
00
1n
`/)
Q
z
_Q
D
z
Z
Q
_J
0-
Z 0
0� LJ
V!I
W
Q
SHEET NO.
C200
JOB NO.47175AA