HomeMy WebLinkAbout05050047.3THIS SHEET TO BE USED FOR EROSION CONTROL ONLY. PERSON ONSITE RESPONSIBLE FOR EROSION CONTROL: KENNETH R. BRASSEUR PLATINUM PROPERTIES L.L.C. Phone: (317)- 818 - 2900 EXISTING EONGRIDGE ESTATES — NOTE: ANY ADDITIONAL EROSION CONTROL MEASURES MAY BE REQUIRED IN THE FIELD BY THE INSPECTOR. NOTE: IF SITE REMAINS INACTIVE FOR A PERIOD OF 2 WEEKS, THEN STABILIZATION IS REQUIRED TO TAKE PLACE IN THE FORM OF TEMPORARY SEEDING, MULCH, OR SPRAY ON PALIMAR. u►u►, STOEPpF "11111 No. 19358 ? o' STATE OF �s••.........• s� SCALE: 1 "= 40' M Seedbed Preparation for Permanent Seeding 1. Test soil to determine pH and nutrient levels. (Contact you county SWCD or Cooperative Extension office for assistance and soils information, including available testing services.) 2. If soil pH is unsuitable for the species to be seeded, apply lime according to test recommendations. 3. Fertilize as recommended by the soil test. If testing WVJ was not done, consider applying 400 -600 lbs. /acre of 12 -12 -12 analysis, or equivalent, fertilizer. 0 4. Till the soil to obtain a uniform seedbed, working I—� the fertilizer and lime into the soil 2 -4 in. deep with V) a disk or rake operated across the slope. (/? 0 W U U U) Qz w0 Z U Z W O� Denotes Construction Limits V) O4d • tl) Z w Z Z d U The following is a list in sequence of construction p O activities to control soil erosion: Z 2 W r n j X 1. The contractor shall schedule a Pre - construction p meeting with the Hamilton County Soil and Water N W Conservation District prior to any construction on tL the site being started. Contractor (ind /or J Developer to notify IDEM and H.C.S.W.F.D 48 hours Qprior to construction beginning. N 2. Maintenance and Refueling area constructed Z 0 3. Concrete washout area constructed J 4. Posting information area shall be constructed. All items, as outlined in the in the 0 &M manual for (To be installed immediately after storm inlet installation.) Post Constuction water quality measures shall be O placed in this area. 5. Perimeter Silt fencing to be installed, Denotes permanent seeding &mulch areas Seeding rate: 130# /acre or 3# /1000 S.F. 6. Grade the site (sides of swales, mounds and ponds to be seeded and mulched irnmediately upon completion. If the site remain-3 inactive for a period of 15 days, stabilization is required to take place in the form of temporary O seeding, mulch or spray on polimar. For temporary seeding, the contractor shall utilize a fast growing seed of either oats, annual ryegrass, wheat or rye depending on time of year. Disturbed areas should be kept to a Denotes seeding w /fiber blanket #S150 by North American Green minimum at all times. Q 7. Storm inlets are to be protected immediately after installation with Drop Inlet Protection or Fiber w Logs. 8. Contractor shall control mud accumulation on all streets surrounding project by installing stone surface at all locations where construction traffic mixture: 31 fescue leaves the site. Dust shall be kept to a minimum by utilizing sprinkling, Calcium Chloride, Vegetative cover, spray on adhesives or other (jpproved 19% perennial rye 19% annual rye methods. S 9. Maintain all filters and traps during construction to prevent any blockages from accumulated 14% orchard grass 10% Kentucky bluegrass sediment. Additional seeding and straw bales may ` be required during construction as specified by J J Engineer or Soil and Water Conservation District. Payment for additional straw bales shall be at the O contractor's expense. Payment for additional :E rip —rap (not shown on plans) and seeding shall be paid for on a unit basis. 10. Contractor shall install all sanitary sewers, storm Y sewers, subsurface drains, curbs, pavement and water mains. Disturbed areas will be stabilized V) after the storm and sanitary are installed. U Disturbed areas will be stabilized after curbs, SSD and pavement are completed unless utilities are starting construction within 15 days of completing the curbs. Stabilize disturbed areas after the Q utilities are installed. 11. Complete Landscaping and sedding all remaining disturbed areas and remove all BMP's when areas are stabilized. u►u►, STOEPpF "11111 No. 19358 ? o' STATE OF �s••.........• s� SCALE: 1 "= 40' M W Q o m ' O O o m W ^II oN L0 O N N 0 w L� w U FIN (n N Q Z O) 0 O to � I W V 0 X Z Q Q LL- _J Q0 I N W r\ liJ I Z_ O O 00 Z W Ln Z F I � cn D -;I- J 00 0 o_ Z z O Q U V) J_ Q H LJJ 0 z Q z Z O Z P WVJ 0 Z I—� 0 <� U) > Z W - Denotes Construction Limits O4d W Z w UJ 6O Denotes Silt Fence Z 2 W r n CD Cn 0 Temporary "Drop Inlet Protection on Basket" 0 O or Coconut Fiber Erosion Control Logs J V (To be installed immediately after storm inlet installation.) O Denotes permanent seeding &mulch areas Seeding rate: 130# /acre or 3# /1000 S.F. Z Q Q Seeding mixture: 25% creeping red fescue 35% O perennial rye 40% Kentucky bluegrass w Denotes seeding w /fiber blanket #S150 by North American Green Q w Seeding rate: 110# /acre or 2.5# /1000 S.F. Seeding 38% Kentucky a mixture: 31 fescue 19% perennial rye 19% annual rye S 14% orchard grass 10% Kentucky bluegrass w ` J J O :E Y V) U Q W Q o m ' O O o m W ^II oN L0 O N N 0 w L� w U FIN (n N Q Z O) 0 O to � I W V 0 X Z Q Q LL- _J Q0 I N W r\ liJ I Z_ O O 00 Z W Ln Z F I � cn D -;I- J 00 0 o_ Z z O Q U V) J_ Q H LJJ 0 z Q z SHEET N0. A9. * Specific Points Where Stormwater Discharge Will Leave this Site: C300 Outlet pipes entering the existing lake. 106 NO.47425LA Z O P WVJ Z I—� <� Ld Lu /�� V!, - Denotes Construction Limits O4d W UJ 6O Denotes Silt Fence Z 2 W r n CD Cn 0 Temporary "Drop Inlet Protection on Basket" D J O or Coconut Fiber Erosion Control Logs J (To be installed immediately after storm inlet installation.) O Denotes permanent seeding &mulch areas Seeding rate: 130# /acre or 3# /1000 S.F. Z Q Seeding mixture: 25% creeping red fescue 35% O perennial rye 40% Kentucky bluegrass w Denotes seeding w /fiber blanket #S150 by North American Green Q Seeding rate: 110# /acre or 2.5# /1000 S.F. Seeding 38% Kentucky mixture: 31 fescue 19% perennial rye 19% annual rye S 14% orchard grass 10% Kentucky bluegrass ` J J O :E V) U SHEET N0. A9. * Specific Points Where Stormwater Discharge Will Leave this Site: C300 Outlet pipes entering the existing lake. 106 NO.47425LA