HomeMy WebLinkAbout05050028.15REMOVE EXISTING ROOF CONSTRUCTION
& INSTALL 2x10 FRAMING AND DECKING
FOR INSULATED MEMBRANE ROOF W/
ROOF SCUPPER ON EAST SIDE.
NEW CAST STONE CAPS & FINIALS
NEW 8 "x12" CAST STONE CAPS
REPAIR EXISTING METAL ROOF FINIAL
NEW DIMENSIONAL ASPHALT ROOF
OVER NEW 1i" OSB DECKING
REPLACE EXISTING DOUBLE HUNG WINDOWS
W/ FIXED CASEMENT WINDOWS. REPAIR all
WOOD TRIM AND REPAINT
L_ L
_4 NEW ALUMINUM FLASHING
NEW CLAD FIXED CASEMENT
WINDOW IN EXISTING OPENING
STRUCTURALLY REPAIR EXISTING
FACTURED MASONRY CORNER
_L CAP �--.
TURED ----,
STONE
SIDES. \�
ilk.
— y.
A6i
i4 EN
1111 M ] I
/4
-� NEW DIMENSIONAL ASPHALT ROOF
T OVER NEW Xi" OSB DECKING
_T -_ -T.
South
3 Exterior Elevation
1
0 2' 4' 8'
NEW FIXED CIRCLE WINDOW
IN EXISTING OPENING
NEW ALUMINUM ENTRY DOORS
W/ FIXED HALF CIRCLE TRANSOMS
WINDOW ABOVE IN EXISTING OPENING
NEW CLAD CASEMENT WINDOWS
IN EXISTING MASONRY OPENINGS
REPAIR OR REPLACE EXISTING
METAL GABLE BOX & INSTALL
NEW METAL FINIAL BALL
6 "x12" CAST STONE WALL CAP
8" REINFORCED CMU WALL W/ CULTURED
STONE'S "DRYSTACK LEDGESTONE"
STONE VENEER ON BOTH SIDES.
L
{
�I
II
'II
�I
it
I
I
I
�I
REPAIR EXISTING METAL ROOF FINIAL
N
1M
NEW DIMENSIONAL ASPHALT ROOF
OVER NEW X" OSB DECKING
REPLACE EXISTING DOUBLE HUNG WINDOWS
W/ FIXED CASEMENT WINDOWS. REPAIR
WOOD TRIM AND REPAINT
NEW ALUMINUM FLASHING
NEW METAL FINIAL BALL
ON EXISTING METAL FASCIA
XX
A7.X
WINDOW & DOOR SCHEDULE:
MK QTY PRODUCT R. 0.
101
2
KCW126
24�2'x30Y2"
102
17
KE2626
30�z 'x302'
103
1
KCX14
3A,"x48y2"
104
3
KCX15
30%-'x603'2"
105
3
KCX16
306'x72Y2"
106
3
KCE118S
3632 "x202-
107
3
KCE15
3632 "x60Y2"
108
6
KCE16
36 YE' x72YE`
001
1
THERMATRU
LA, 3/0 x 8/0
Smooth -Star
Hinged Entry
W/ 30"
HIGH TRANS ❑M
002
1
THEPMATRU
LA, 2118 x 8/0
Smooth -Star
Hinged Entry
003
1
THERMATRU
LA, 5/0 x 8/0
Smooth -Star
Hinged Patio
004
1
THERMATRU
LA 5/0 x 6/8
Smooth -Star
Hinged Patio
005
1
SIMPSON
6002 30"x80"
ALL
WINDOWS ARE
KOLBE & KOLBE CLAD
UNITS
WITH
LOW -E
INSULATED GLASS, EXTERIOR
CLADDING,
AND FOLDING
HARDWARE FOR CASEMENTS.
SEE
EXTERIOR ELEVATIONS FOR OPERATION OF UNITS.
GENERAL NOTES:
L THE OWNER WILL NET BE OCCUPYING THE
BUILDING DURING CONSTRUCTION
2, ALL WORK SHALL BE DONE IN ACCORDANCE TO
WITH THE 2000 IBC CODE, INDIANA CONSTRUCITON
RULES AND ALL ETHER APPLICABLE CODES AND
REGULATIONS
3, ONLY WRITTEN DIMESIONS SHALL BE USED. D❑
NOT SCALE THE DRAWINGS. DIMENSIONS SHALL BE
VERIFIED ON THE JOB SITE BY THE CENTRACTOR,
ANY DISCREPANCIES SHALL BE BROUGHT TO THE
ATTENTION - OF THE ARCHITECT PRIOR TO THE
COMMENCEMENT OF ANY WORK,
4, DIMENSIONS ARE TO FACE OF EXISTING
CONSTRUCTION, NEW FRAMING OR MASONRY
CONSTRUCTION, UNLESS OTHERWISE NOTED
5, ALIGN NEW CONSTRUCTION ADJACENT T❑
EXISTING CONSTRUCTION TO MATCH FINAL WALL
FINISHES
6.
PATCH AND REPAIR ALL EXISTING WALL, FLOOR,
CEILING, ETC FINISHES TO MATCH EXISTING
ADJACENT TO NEW CONSTRUCTION OR DEMOLISHED
AREAS.
REMOVE EXISTING ROOF CONSTRUCTION
& INSTALL 2x10 FRAMING AND DECKING
FOR INSULATED MEMBRANE ROOF W/
ROOF SCUPPER ON EAST SIDE.
NEW CAST STONE CAPS & FINIALS
NEW 8 "x12" CAST STONE CAPS
OUTLINE OF EXISTING ARCHED OPENING W/ BRICK INFILL
NEW BACK ILLUMINATED METAL SIGN W/
LASER CUT LETTERS & IMAGE, AND PERIMETER
TRANSLUCENT BASE FOR BACK LIGHTING
r _ _
I,
NEW HALF ROUND TRANSOM UNIT ABOVE
/ - - DECORATNE WOOD HEADER OVER DOOR
_ V _
j REFURBISH AND REINSTALL EXISTING
i COPPER ENTRY DOOR W/ NEW FRAME
NEW CAST STONE DOOR OPENING SURROUND
REMOVE EXISTING DETERIORATED CONCRETE
......................................................
The Deacon Restaurant
31 Second Street SE, Carmel
No Exterior Elevations
Exterior Elevation
SCALE: 1/4"=V-0"
DATE: 07/12/05
0 2' 4 $1 PAGE: 3 of 1
REVISE: A4.1
Demerly Architects
ARCHITECTURE / INTERIORS / PLANNING
6144 North Park Avenue, Indianapolis, Indiana 46220
TEL 317.847.0724
FAX 888.895.2811
E.MAIL mark@demerlyarchitects.com