HomeMy WebLinkAbout05050028.17REPAIR EXISTING METAL ROOF FINIAL
NEW DIMENSIONAL ASPHALT ROOF
OVER NEW V OSB DECKING
EXISTING WOOD BRACKETS
REPLACE EXISTING DOUBLE HUNG WINDOWS
W/ FIXED CASEMENT WINDOWS. REPAIR
WOOD TRIM AND REPAINT
NEW ALUMINUM FLASHING
NEW DIMENSIONAL ASPHALT ROOF-,,
OVER NEW h' OSB DECKING
_ 7-2-14 T
T
T T
REPLACE A 1
— 7-
LL PERIMETER
-_ -- T.
_ WOOD EAVE TRIM W/ \ _ -_
1 LT PAINTED F -J REDWOOD TRIM
T T- NEW 6 ALUMINUM GUTTER-N)1/ [STRUCTURALLY REPAIR EXISTING FACTORED MASONRY CI
�� _ —
& DOWNSPOUTS//IN
NEW CLAD DOUBLE HUNG WINDOW IN EXISTING OF
Y-F,I EXISTING METAL GRATING CLEANED & REP
_ - L - - -- - -- - -- - -- - - -
--
PAINT EXISTING CMU EXTERIOR WALL. _ - -- - --
l tit
jl rilTrMtrTr7r
I r I I
East
4 , Exterior Elevation
0 2' 4 8'
WINDOW & DOOR SCHEDULE:
MK QTY PRODUCT R. 0.
101
2
KCW126
24y2'x30y2"
102
17
KC2626
30Yx30xz"
103
1
KCX14
3A?"x48yz"
104
3
KCX15
30�2'x60Vz"
105
3
KCX16
30Y2"x72Yz"
106
3
KCE118S
11 6Yx20Y2'
107
3
KCE15
36yz "x6A2'
108
6
KCE16
36Yz "x72Y2"
001
1
THERMATPU
LA, 3/0 x 8/0
Smooth -Star
Hinged Entry
W/ 30"
HIGH TRANSEM
002
1
THERMATPU
LA, 2/8 x 8/0
,mooth -Star
Hinged Entry
003
1
THERMATPU
LA, 5/0 x 8/0
Smooth -Star
Hinged Patio
004
1
THERMATPU
LA, 5/0 x 6/8
Smooth -Star
Hinged Patio
005
1
SIMPS ❑N
6002 30"x80"
ALL
WINDOWS ARE
KOLBE & KOLBE CLAD
UNITS
WITH
LOW -E
INSULATED GLASS, EXTERIOR
CLADDIPJG,
AND FOLDING
HARDWARE FOR CASEMENTS.
SEE
EXTERIDR ELEVATIONS FOR OPERATION OF UNITS.
NEW METAL FINIAL BALL
`ON EXISTING METAL FASCIA
REPAIR OR REPLACE EXISTING
METAL GABLE BOX & INSTALL
-NEW METAL FINIAL BALL
NEW CLAD FIXED CASEMENT
- WINDOW IN EXISTING OPENING
- REMOVE EXISTING SHED ENTRANCE
6'x12' CAST STONE WALL CAP-
8' REINFORCED CMU WALL W/ CULTURED- \
trnu Nr •nnvnrni rnnrern.N
GENERAL NOTES:
1. THE OWNER WILL NOT BE OCCUPYING THE
BUILDING DURING CONSTRUCTI ❑N:
2, ALL WERK SHALL BE DONE IN ACCORDANCE TO
WITH THE 2000 IBC CODE, INDIANA C❑NSTPUCIT ❑N
RULES AND ALL ETHER APPLICABLE CODES AND
REGULATI ❑NS,
ONLY WRITTEN DIMESI ❑NS SHALL BE USED. D❑
NET SCALE THE DRAWINGS. DIMENSI ❑NS SHALL BE
vEPIFIED ❑N THE JOB SITE BY THE CONTRACTOR,
ANY DISCREPANCIES SHALL BE BROUGHT TO THE
ATTENTI ❑N OF THE ARCHITECT PRIOR TO THE
CEMMENCEMENT OF ANY WORK
DIM--NSI❑N� ARE TO FACE OF EXISTING
CONSTRUCTION, NEW FRAMING OR MASONRY
CONSTRUCTION, UNLESS OTHERWISE N❑TED,
5 ALIGN NEW CONSTRUCTION ADJACENT T❑
EXISTING C ❑NSTRUCTI ❑N TO MATCH FINAL WALL
FINISHES
6.
PATCH AND REPAIR ALL EXISTING WALL, FLOOR,
CEILING, ETC. FINISHES TO MATCH EXISTING
ADJACENT T❑ NEW CONSTRUCTI ❑N OR DEMELISHED
AREAS.
SECOND FLOOR
109'-11"
_ EXIST. LOWER FLOOR
90' -1 1 /2"
The Deacon Restaurant
31 Second Street SE, Carmel
Exterior Elevations
SCALE:
1/4"=V-0"
DATE:
07/12/05
PAGE:
3 of 1
REVISE:
A4.3
Demerly Architects
ARCHITECTURE / INTERIORS / PLANNING
6144 North Park Avenue, Indianapolis, Indiana 46220
TEL 317.847.0724
FAX 888.895.2811
EMAIL mark@4 demerlyarchitects.com