HomeMy WebLinkAbout05050028.18GENERAL NOTES:
1, THE OWNER WILL NOT BE OCCUPYING THE
BUILDING DURING CONSTRUCTI ❑N,
2, ALL WORK SHALL BE DONE IN ACCORDANCE TO
WITH THE 2000 IBC CODE, INDIANA C❑NSTRUCIT ❑N
RULES AND ALL OTHER APPLICABLE CODES AND
REGULATI❑NS,
3, ONLY WRITTEN DIMESIONS SHALL BE USED D❑
NET SCALE THE DRAWINGS, DIMENSI ❑NS SHALL BE
VERIFIED ON THE JOB SITE BY THE CONTRACTOR,
ANY DISCREPANCIES SHALL BE BROUGHT TO THE
ATTENTI ❑N ❑F THE ARCHITECT PRI ❑R TO THE
COMMENCEMENT OF ANY WORK,
4, DIMENSI ❑NS ARE TO FACE OF EXISTING
C❑NSTRUCTI ❑N, NEW FRAMING OR MASONRY
CONSTRUCTION, UNLESS OTHERWISE NOTED,
5 ALIGN NEW CONSTRUCTION ADJACENT TO
EXISTING C❑NSTRUCTI ❑N TO MATCH FINAL WALL
FINISHES
6.
PATCH AND REPAIR ALL EXISTING WALL, FLOOR,
CEILING, ETC FINISHES TO MATCH EXISTING
ADJACENT TO NEW CENSTRUCTI ❑N OR DEMOLISHED
AREAS,
>ECOND FLOOR
109' -11"
FIRST FLOOR
100' -0"
LOWER FLOOR
90' -1 1/2"
The Deacon Restaurant
31 Second Street SE, Carmel
Building Sections
SCALE: 1/4"=I'-O"
DATE: 07/12/05
PAGE: 3 of 1
REVISE: A5.1
Demerly Architects
ARCHITECTURE / INTERIORS / PLANNING
_y
6144 North Park Avenue, Indianapolis, Indiana 46220
TEL 317.847.0724
FAX 888.895.2811
E.MAIL mark @demerlyarc}hitects.com
IN FA �