Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
E1.0 POWER_COMMUNICATIONS PLAN.PDF
Project Number: Sheet Title: Issue Date: Sheet Number: Project: CA R M E L , I N D I A N A 4 6 0 3 2 By: Architect: Architecture / Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) RE E S E K I T C H E N S Drawn By Checked ByPrint Date Revisions: 20 0 S O U T H R A N G E L I N E R O A D SU I T E 2 0 1 IN D I A N A D E S I G N C E N T E R COPYRIGHT & OWNERSHIP: E1.0 POWER/ COMMUNICATIONS PLAN Parcel 12 PEDCOR DESIGN GROUP, LLC 2/13/13 CONSTRUCTION DOCUMENTS 02/14/13 STATE RELEASE SET THIS DOCUMENT IS AN INSTRUMENT OF SERVICE AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2013, JAMES R. STUTZMAN, AIA, NCARB, CARMEL. PLAN NORTH 1 A E G M 11 5 L.E.S.M.C. 11 GEA M 5 1 PLAN NORTH KEY PLAN SCALE: N.T.S. SECOND FLOOR N EP3 EP2 EP4 NE W D O O R F 3 6 8 9 J ELECTRICAL IN CABINET/APPLIANCE AREAS, UNLESS OTHERWISE NOTED, IS FOR LIGHTS, CLOCKS & DIALS ONLY WO R K I N G K I T C H E N ELECTRICAL TO BE RUN IN CABINETS AFTER CABINET INSTALLATION ELECTRICAL / PHONE & DATA TO BE RUN IN CABINETS AFTER CABINET INSTALLATION 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 F 3 F 3F 3 F 3 F F 3 3 F 3 F 3 F 3 F 3 F 3 F 3 4 66 6 6 8 F 3 F 3 F 3 7 7 7 7 7 7 48 " a 7 48 " a 7 7 5 5 5 5 5 5 5 5 5 5 5 5 10 F F 3 3 ELECTRICAL IN CABINET/APPLIANCE AREAS, UNLESS OTHERWISE NOTED, IS FOR LIGHTS, CLOCKS & DIALS ONLY ELECTRICAL IN CABINET/APPLIANCE AREAS, UNLESS OTHERWISE NOTED, IS FOR LIGHTS, CLOCKS & DIALS ONLY ELECTRICAL IN CABINET/APPLIANCE AREAS, UNLESS OTHERWISE NOTED, IS FOR LIGHTS, CLOCKS & DIALS ONLY ELECTRICAL IN CABINET/APPLIANCE AREAS, UNLESS OTHERWISE NOTED, IS FOR LIGHTS, CLOCKS & DIALS ONLY ELECTRICAL IN CABINET/APPLIANCE AREAS, UNLESS OTHERWISE NOTED, IS FOR LIGHTS, CLOCKS & DIALS ONLY 48 " a 48 " a 48 " a 48 " a 6 CONTRACTOR TO PROVIDE POWER FOR 3 WORKING HOODs. SEE APPLIANCE SPEC SHEETS FOR EXACT REQUIREMENTS. CONTRACTOR TO PROVIDE AND INSTALL JUNCTION BOX ABOVE TO POWER LIGHTS AND DIALS ON HOODS OR OVER-THE-RANGE MICROWAVES. RECEPTACLES WILL BE PULLED by contractor AT TIME OF DISPLAY INSTALLATION. CONTRACTOR TO PROVIDE AND INSTALL FAN/FIXTURE BOX RATED FOR 100 LBS. FEI WILL PROVIDE LIGHT FIXTURE CONTRACTOR TO INSTALL FIXTURE. CONTRACTOR TO PROVIDE & INSTALL DUPLEX OUTLET TURNED SIDEWAYS IN BACKSPLASH FOR CONVENIENCE VERIFY LOCATION WITH PROJECT MANAGER PRIOR TO INSTALLATION. WORK NOTES 1 2 3 4 6 5 7 8 CONTRACTOR TO PROVIDE OUTLETS/WIRING FOR WORKING APPLIANCES. REFER TO APPLIANCE SPECS FOR EXACT REQUIREMENTS. CONSULT CABINET DRAWINGS AND APPLIANCE SPECS FOR EXACT LOCATION OF OUTLETS. CONTRACTOR TO PROVIDE A QUADRAPLEX OUTLET AND A PHONE/DATA CONDUIT BOX. CONTRACTOR TO PROVIDE ONE DEDICATED DUPLEX OUTLET AT 98" AFF FOR UNDERCOUNTER CABINET LIGHTING, SOFFIT LIGHTING & TOE KICK LIGHTING. SEE CABINET PLANS FOR EXACT LOCATIONS AND SPECIFICATIONS. CONTRACTOR TO VERIFY LOCATIONS WITH PROJECT MANAGER PRIOR TO INSTALLATION. 9 10 ELECTRICAL LEGEND JUNCTION BOX, DEDICATED 20A CIRCUIT SUSPENDED ABOVE DROP CEILING OR MOUNTED TO THE UNDERSIDE OF ROOF DECK. QUADRAPLEX OUTLET DUPLEX OUTLET 3/4" EMPTY CONDUIT SYSTEM COMPLETE WITH PULL CORDS J F FAN/FIXTURE BOX RATED FOR 100 LBS. SUSPENDED FROM STRUCTURE ABOVE WITH TWO (2) PIECES 3/8" ALL-THREAD CONNECTED TO ONE (1) 8" UNISTRUT FOR A SINGLE FAN/FIXTURE BOX, DROPPED DOWN TO 11'-0" AFF CONTRACTOR TO PROVIDE RECESSED ELECTRICAL OUTLET AND EMPTY CONDUIT WITH PULL BOX FOR DIGITAL SIGNAGE. LOCATE ELECTRICAL OUTLET AT 6'-0" AFF, 13" TO THE RIGHT AND 9" UP. SEE DETAIL 2E ON SHEET E1.0 FOR CLARIFICATION. TO BE PULLED DURING SCREEN AND MEDIA PLAYER INSTALL. INSTALLATION OF SCREEN AND MEDIA PLAYER BY OTHERS. CONTRACTOR TO PROVIDE ELECTRICAL FOR BACK LIGHTED SIGN. VERIFY REQUIREMENTS WITH PROJECT MANAGER PRIOR TO INSTALLATION. CONTRACTOR TO PROVIDE ELECTRICAL FOR GAS RINNAI TANKLESS WATER HEATER RU98I, SEE SPECIFICATIONS FOR EXACT REQUIREMENTS. TANKLESS WATER HEATER SUPPLIED BY FEI. 1) CONTRACTOR TO PROVIDE ALL NECESSARY LABOR, EQUIPMENT, FOR ALL WORK INDICATED TO PROVIDE A COMPLETE AND USABLE SYSTEM, WORK IS TO BE IN COMPLIANCE WITH ALL UPDATED ADA, LOCAL CODES, STATE CODES. ALL WORK IS TO BE COORDINATED WITH ALL OTHER TRADES. 2) IT IS THE INTENTION OF THE DRAWINGS TO FULLY COVER ALL WORK AND MATERIALS FOR A COMPLETE FIRST CLASS ELECTRICAL INSTALLATION. ANY DEVICES SUCH AS PULL BOXES AND DISCONNECT SWITCHES USUALLY EMPLOYED IN THIS CLASS OF WORK, THOUGH NOT SPECIFICALLY MENTIONED OR SHOWN ON DRAWINGS OR SPECIFICATIONS, BUT MAY BE REQUIRED FOR THE SATISFACTORY COMPLETION OF THE WORK, SHALL BE FURNISHED AND INSTALLED AS PART OF THE CONTRACTORS TOTAL WORK. 3) ALL ITEMS SHOWN ARE NEW AND SHALL BE PROVIDED BY THE CONTRACTOR UNLESS SPECIFICALLY STATED OTHERWISE. 4) VERIFY ALL EQUIPMENT REQUIREMENTS, INCLUDING MOUNTING REQUIREMENTS PRIOR TO ROUGH-IN. 5) CONTRACTOR TO OBTAIN ALL INSPECTIONS AND PERMITS. 6) PROVIDE A WRITTEN WARRANTY STATING THAT ALL MATERIALS AND WORKMANSHIP ARE FREE FROM DEFECTS FOR A PERIOD OF 12 MONTHS FROM DATE OF FINAL ACCEPTANCE. IN ADDITION, DELIVER TO THE OWNER ALL WARRANTY AGREEMENTS FROM THE EQUIPMENT MANUFACTURERS. GENERAL ELECTRICAL NOTES 7) COORDINATE ALL WORK WITH ALL OTHER TRADES PRIOR TO ROUGH-IN. PROVIDE CONDUIT AND WIRING UP TO AND INCLUDING FINAL CONNECTIONS TO MECHANICAL EQUIPMENT & FURNITURE SYSTEM. 8) THE CONTRACTOR SHALL PROVIDE EMPTY CONDUIT SYSTEM COMPLETE WITH PULL CORDS PER SPECIFICATIONS FOR THE PHONE/DATA SYSTEM. REFER TO PLAN FOR LOCATIONS AND HEIGHTS OF SCHEDULED DEVICES 9) WIRING DEVICE PLATES SHALL BE WHITE. 10) SEAL ALL CONDUIT PENETRATIONS THROUGH WALLS IN ACCORDANCE WITH N.E.C. REQUIREMENTS FOR FIRE RATED SPACES. 11) ANY DISCREPANCIES BETWEEN DISCIPLINES SHALL BE ASSUMED TO REQUIRE THE MORE EXPENSIVE SOLUTION. THAT SOLUTION SHALL BE INCLUDED IN THE CONTRACTOR'S BASE BID. 12) ALL WIRING SHALL BE CONCEALED. 13) ALL SERVICE RECEPTACLES TO BE MOUNTED AT 16" AFF. UNLESS OTHERWISE NOTED. MOUNTING HEIGHTS SHALL BE TO THE BOTTOM OF THE DEVICE ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED. VERIFY THE EXACT PLACEMENT OF ALL POWER, TELEPHONE & DATA OUTLETS PRIOR TO ROUGH-IN. TAKE SPECIAL CARE FOR OUTLETS MOUNTED IN OR ON CASE WORK. 14) COORDINATE EXACT LOCATION OF LIGHTS, SO AS NOT TO CONFLICT WITH HVAC DUCT WORK. 15) CONTRACTOR TO FURNISH AND INSTALL EMERGENCY AND EXIT LIGHTING REQUIRED TO MEET ALL UPDATED CODES. 16) PROVIDE LEGIBLY TYPED PANEL BOARD DIRECTORIES INDICATING USAGE & LOCATION OF CIRCUITS. PROVIDE LABELS ON ALL DISCONNECT SWITCHES INDICATING CIRCUIT AND USAGE. A.1 CBA.5A A.2 D 8 8.1 10 11 9.1 8.15 9.9 10.9 10.85 9 7'- 2 " 6'- 0 " 10 ' - 0 " DIGITAL SCREEN INSTALLED BY OTHERS 1'-1" 9" EQUAL EQUAL center of electrical outlet data jack VERIFY LOCATION OF SCREEN WITH PROJECT MANAGER PRIOR TOROUGH-IN SCALE: DIGITAL SIGNAGE 4D E1.03/8"=1'-0" POWER FROM PANEL (TYP.) 1-5/8" UNI-STRUT SUPPLIED & INSTALLED BY CONTRACTOR 3/8" THREADED ROD CONNECTED EVERY 4' OF LIGHTING UNI-STRUT TO BUILDING UNISTRUT 1 DUPLEX RECEPTACLEFACING UP EVERY 8' NOT TO SCALE LEGS FACING UP SCALE: UNISTRUT MOUNTING DETAIL 4D E2.1NOT TO SCALE BAR JOIST threaded rod support every 4' o.c.END VIEW SIDE VIEW SINGLE PIECE OF 1-1/2" UNISTRUT/ BOTTOM AT 11'-0" AFF SCALE: 3/16" = 1'-0" 1 POWER AND COMMUNICATION PLAN E1.0