Loading...
HomeMy WebLinkAboutE2.0 LIGHTING PLAN.PDFProject Number: Sheet Title: Issue Date: Sheet Number: Project: CA R M E L , I N D I A N A 4 6 0 3 2 By: Architect: Architecture / Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) RE E S E K I T C H E N S Drawn By Checked ByPrint Date Revisions: 20 0 S O U T H R A N G E L I N E R O A D SU I T E 2 0 1 IN D I A N A D E S I G N C E N T E R COPYRIGHT & OWNERSHIP: E2.0 LIGHTING PLAN Parcel 12 PEDCOR DESIGN GROUP, LLC 2/13/13 CONSTRUCTION DOCUMENTS 02/14/13 STATE RELEASE SET THIS DOCUMENT IS AN INSTRUMENT OF SERVICE AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2013, JAMES R. STUTZMAN, AIA, NCARB, CARMEL. PLAN NORTH 1 A E G M 11 5 L.E.S.M.C. 11 GEA M 5 1 PLAN NORTH KEY PLAN SCALE: N.T.S. SECOND FLOOR N NE W D O O R LIMIT OF SOFFIT LIM I T O F S O F F I T LIMIT OF SOFFIT SP 1 22 2 2 2 2 2 2 2 2 2 SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP 4 SP SP 2 2 2 2 2 2 2 2 22 2 W RW W W W RRR 2X4 FLOURESCENT LIGHT FIXTURE, 3 TUBE. SUBMIT PSEC SHEETS TO PROJECT MANAGER LIGHT SWITCH CEILING LEGEND 1 LIGHTING WORK NOTES CONTRACTOR TO PROVIDE AND INSTALL SWITCH TO CONTROL TRACK LIGHTING, UNDER CABINET, DECORATIVE & MISC. LIGHTING FROM CONTACTOR AT PANEL. NOTE: SOME VIGNETTES ALSO HAVE SWITCHES IN THE AREA. ABOVE CABINET, UNDER CABINET, BASEBOARD AND LIGHTING BEHIND GLASS CABINET FRONTS WILL BE PROVIDED AND INSTALLED BU FEI. THE TYPES OF LIGHTING CAN INCLUDE TAPE-LED, LED UNDERCOUNTER FIXTURES (9", 12", 18" & 24" LONG), LED SPOTLIGHTS, SURFACE MOUNTED XENON SPOTLIGHTS, LED STICKS, LED TWIN STICKS, AND FLUORESCENT SLIMLITES. CABINETS PLANS WILL SHOW THE LOCATIONS AND TYPES OF LIGHTING REQUIRED FOR EACH AREA. SPECS FOR TYPES OF LIGHTING TO BE USED ARE PROVIDED WITH THIS BID SET. CONTRACTOR IS RESPONSIBLE FOR ELECTRICAL POWER FOR LIGHTING ONLY. EMERGENCY LIGHTING PALN PER LOCAL CODES IF NOT REQUIRED MUST BE DESIGNED AND PROVIDED BY CONTRACTOR AND COORDINATED WITH PROJECTS MANAGER PRIOR TO CONSTRUCTION AND INSTALLATION. 2 3 LUTRON DIMMERS FOR DECORATIVE LIGHTING. GROUP TIGHTLY TOGETHER. VERIFY LOCATION W/PROJECT MANAGER PRIOR TO INSTALLATION. SWITCH UNDERCOUNTER, SOFFIT AND LIGHTING IN CABINETS SEPERATELY. SEE CABINET DRAWINGS & VERIFY WITH PROJECT MANAGER. LUTRON DIMMERS ARE PROVIDED BY FEI AND INSTALLED BY CONTRACTOR. JUNO ONE CIRCUIT TRACK LIGHTING SYSTEM WITH 620 TRACK HEAD, FINISH: BLACK. PROVIDE TCP BRAND TIP301641K BULBS. SUSPEND TRACK FROM 1/4" ALL THREAD OR MANUFACTURER'S STEMS FROM STRUCTURE ABOVE TO 11'-0" AFF. PAINT ALL THREAD OR STEMS TO MATCH TRACK. FEATURE DECORATIVE LIGHTING SELECTED AND SUPPLIED AND INSTALLED BY FEI BRANCH USING THE FAN/FIXTURE BOX RATED FOR 100 LBS. INSTALLED BY CONTRACTOR FROM STRUCTURE ABOVE. VERIFY LOCATION PRIOR TO INSTALLATION. BOTTOM OF FIXTURE MOUNTED AT 8'-0" AFF 2X4 WHITE ACOUSTICAL CEILING TILE ARMSTRONG CIRRUS W/PRELUDE 15/16" EXPOSED TEE GRID SP 4 W R JUNO TC20-688W-WH 5" WALL WASH W/WHITE TRIM AND 50W PAR30 LAMP; CONTRACTOR TO SUPPLY & INSTALL. VERIFY LOCATION PRIOR TO ROUGH-IN JUNO TC20-203W-WH 5" DOWNLIGHT W/WHITE TRIM A.1 CBA.5A A.2 D 8 8.1 10 11 9.1 8.15 9.9 10.9 10.85 9 SCALE: 3/16" = 1'-0" 1 LIGHTING PLAN E2.0