Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
T1.5 SECOND LEVEL LIFE SAFETY PLAN.PDF
Project Number: Sheet Title: Issue Date: Sheet Number: Project: CA R M E L , I N D I A N A 4 6 0 3 2 By: Architect: Architecture / Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) RE E S E K I T C H E N S Drawn By Checked ByPrint Date Revisions: 20 0 S O U T H R A N G E L I N E R O A D SU I T E 2 0 1 IN D I A N A D E S I G N C E N T E R COPYRIGHT & OWNERSHIP: T1.5 SECOND LEVEL LIFE SAFETY PLAN Parcel 12 PEDCOR DESIGN GROUP, LLC 2/13/13 CONSTRUCTION DOCUMENTS 02/14/13 STATE RELEASE SET THIS DOCUMENT IS AN INSTRUMENT OF SERVICE AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2013, JAMES R. STUTZMAN, AIA, NCARB, CARMEL. PLAN NORTH 1 A E G M 11 5 L.E.S.M.C. 11 GEA M 5 1 PLAN NORTH KEY PLAN SCALE: N.T.S. SECOND FLOOR N L L.7L.6 L.9 MJK.1K K.5G.3 G.4 H H.5 .6 .5 1 F 5 7 G 6 3 2.9 2 8 8.1 A.1 C E 10 4 H.9 11 9.1 8.15 9.9 10.9 10.85 7.8 7.3 3.8 3.3 BA.5A A.2 D 9 R REESE KITCHEN 4,653 SQ.FT. 105'-9" EG R E S S # 1 EGRESS #2 NEW D O O R FLA T SCR E E N T V ulin e 36" b e v c t r u30 3 6 b v w c o l 42 / 3 0 BBFF30 42 / 3 6 42/3042/2442/3042/24 42 / 3 0 42 / 3 6 42 / 2 4 42/3042/24 BF B B F 2 4 BBFF30 BF B B F 2 4 BBFF30 BF B B F 2 4 83'-0" BF B B F 2 4 BUILDING CODES: SPRINKLER SYSTEM: PROJECT BUILDING CODES BUILDING HEIGHT: OCCUPANCY LOAD:78 PEOPLE. FULLY PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM AS PER NFPA 13 - 1999 CODE COMPLIANCE SCHEDULE Indiana Building Code, 2008 Edition (IBC 2006) Indiana Accessibility Code (ANSI A117.1-2003) Minimum Design Loads (ASCE 7-2005) Indiana Plumbing Code, 1999 Edition (UPC 1997) Indiana Mechanical Code, 2008 Edition (IMC 2006) Indiana Fuel Gas Code, 2008 Edition (IFGC 2006) NFPA 13-1999 Installation of Sprinkler Systems OCCUPANCY: Group M - Merchantile CONSTRUCTION TYPE: Type II-B - Non-combustible construction materials; Non-rated 2008 2008 2008 1999 2008 2008 2002 PROJECT AREA: Indiana Electrical Code, 2008 Edition (NFPA 70-2008)2009 APPROVALS:PROJECT NO. 323831 CDR LETTER FOUNDATION RELEASE 02.02.07 PROJECT NO. 323831 CDR LETTER STANDARD RELEASE - ARCHITECTURAL 02.16.07 PROJECT NO. 323831 CDR LETTER STANDARD RELEASE - MEP 02.04.08 FIREWALL VARIANCE NO. 10-04-57 (A,B,C,D) 04.06.10 2 STORY. 4,653 S.F. GROSS TENANT AREA General Administrative Rules (675 IAC 12)2006 NFPA 72-2002 National Fire Alarm Code 2006 Indiana Energy Conservation Code (ASHRAE 90.1 2007)2010 NFPA 10-2002 Portable Fire Extinguishers 2006 NFPA 90A - Installation of Air Conditioning & Ventilating Systems 1999 NFPA 90B - Installation of Warm Air Heating and Air Conditioning Systems 1999 Americans with Disabilities Act (2010 Standards for Accessible Design)2010 SCALE: 1/16" = 1'-0" 1 SECOND LEVEL LIFE SAFETY PLAN T1.5