Loading...
HomeMy WebLinkAbout05060010-Site Plan1his Plot Pkm Prepm'ed F~ R.H. of Indiana ~ot ~.. ~ ~ _ Lot # 182 , containing 17,674 S.F.+, in aa~oume ?~[~..o..~ Sect # 3 I~N.c.S~, t 200400080247 PC. t ~, Stidet 535 Hamilton Count);, aey T~ Sec T BN, RO E 3645 DOLAN WAY (70'R/~I) Prepared Date: 05/27/05: By:. JKI propO~ed BUy~S~. JAMES AND JENNIFER LEMERE Community Restrictions: Side Yard = 5' Note: Sump pomp(s) to be Rem' Yard = 20' placed by builder as needed. Aggregate = 10' (B.H.) R.H. of Indiana Finished Floor Elevation Information Pad Grade = 919;9 per plan Pad Crude + 0.7 = ~erage FTE (920.6) Garage FFE + 1.5' = ?sidenU~l FFE (922.1) Resi~enticl FFE - 9.0 = Basement FFE (913.1) Note: Sunttory Sewer Top of Casting Information Upstream Manhole, TC= 919.50 Downstream Manhole, TC=919.69 per plen. Lot # 182 VB05.0034392 Note: The garage finished floor elewUon is 1.7' above the curb at the drive, per pron. Sod Calculations: {}rive = 1,086S~:t: Public Walk =1,242 SC~ Private Walk =200 Hydroseeding =6,861 Sod =975 SY:I: . from Rear of residence. Sidewalk to be placed 1' from property line, Var.' from back of curb, Assumed North per plan. Scale: t' = 30' Note: Per Cormd zoning ordinance 26.1.1: The residential district limits height to twenty-five feet (25'), however a dwelling may be increased in height to thirty-five feet profiled the side and rear y~ds are increased on addit~ol ~,e, foot (1') for each one font (1) the sb~cture exceeds the tweet~-five feet (25') in halghL Note.' The contractor ts to maintain a minimum distance of ten feet (10) between the eaoltory sewer and water line latarale. FLOOD HAZARD STATEMENT CERTIFICATION g $0503 '" -=-- STATE OF' 63' DOLAN WAY 15' DU&SE Note: This drawing is bused on constmcUon plans or record drawings, an~ s not based upon a field survey. 1he Schneider Cerperafion does not WmTent the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any constmcUso. Any discrepancy found on this drawing should be r~orted to The Schneider Corporation immedidteiy; failing to do so results in the contractors assumption of ell liability, Note: The basement elevetien, depicted here0~, has been determined ~nd based upon the p~d gra~es end/or contonm tcken from the constructio~ plans for this eubdMslon. Unless stated, no information about fluctuating water tebtee, soil conditions, or soil types has been provk~ed or stated on sold plane, It that the basement at least two feet ~ove the normal pool elevation . unless a study pron~ any ground wats Corporation should be notified immediately. The basement elevation shoald be raised two feet (2) above the ground ajar, and additional construction t~chdiquee shonld be incorpor~ffed to o~eviate future problems. Detail af Grcund/Storm Water flaw patten for individual lots, Not~ Duilder to ensure drainage away frum structure(s). 42.9' '~ ~- ~FIe ~d H~ zal d S:~ement~ The accuracy of any flood hazard data shown at3 this report ,$ subject tO map scale uncertainty an{3 to any other uncertainty in location or elevation on the referenced flood insurance rate map. ALL of the within described land DOES NOT lie within that special flood hazard zone AE as said land plots by scale on flood insurance rate map #180081 0205 F for the City of Carmel. Indiana dated February 19. 2003. LJ.J TC=916,71 PER R~N