BUILDING STD.
DIFFUSER
BUILDING STD.
CFI
Li
EXAM
EXAM
EXAM
EXAM
EXAM
STAFF
p
2D3
204
205
206
201
211
r 0
CN CD
oo 0 o
c� ti
Li z
N
W W Q 00
-//
ELEOTIOAL FLAN
/811 = II -0❑
VERIFY EXACT LOCATION
WITH EQUIPMENT PROVIDER
SGOPE DOGUMENTS
THE DOCUMENTS ARE INTENDED TO INDICATE THE GENERAL SCOPE OF
THE PROJECT IN TERMS OF DESIGN CONCEPT, DIMENSIONS, AND MAJOR
ARCHITECTURAL ELEMENTS. THESE DOCUMENTS DO NOT NECESSARILY
DESCRIBE OR INDICATE ALL WORK REQUIRED FOR FULL PERFORMANCE
AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE
BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED, EACH TRADE
CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED FOR
THE PROPER EXECUTION AND COMPLETION OF THIS WORK.
6ENERALNOTES
1. THE DRAWINGS AND SPECS. ARE AN INSTRUMENT OF SERVICE AND ARE
THE SOLE PROPERTY OF THE ARCHITECT. ANY RE -USE OR
DUPLICATION OF THESE DOCUMENTS IS PROHIBITED WITHOUT THE
EXPRESSED WRITTEN CONSENT OF THE ARCHITECT.
2. THE DRAWINGS AND SPECS. ARE THE SOLE PROPERTY OF THE OWNER.
ANY RE -USE OR DUPLICATION OF THESE DOCUMENTS IS PROHIBITED
WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE OWNER.
3. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH ALL
APPLICABLE CODES, LAWS, AND ORDINANCES.
4. VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION.
NOTIFY ARCHITECT IMMEDIATELY OF CONFLICTS PRIOR TO PROCEEDING.
5. EACH CONTRACTOR SHALL SCRUTINIZE ALL DRAWING SHEETS TO
DETERMINE FULL EXTENT OF RESPONSIBILITIES FOR EACH RESPECTIVE
TRADE.
6. EACH CONTRACTOR SHALL PROVIDE ALL BARRICADES, ETC. AS REQUIRED
BY LAW, CODE OR ORDINANCE AND AS OTHERWISE REQUIRED.
7. EACH CONTRACTOR IS REQUIRED TO REMOVE ALL CARTONS, BOXES,
MATERIALS, TRASH AND DEBRIS CAUSED BY HIS WORK FROM THE
JOB SITE DAILY.
8. ALL MATERIALS SUSPENDED FROM STRUCTURE ABOVE SHALL BE HUNG
FROM THE TOP CHORD OF THE JOIST. THIS INCLUDES BUT IS NOT
LIMITED TO BULKHEADS, SPRINKLER LINES, CEILINGS, GAS PIPING,
STORM WATER, ELECTRICAL CONDUIT, ETC.
9. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SECURING ALL
REQUIRED PERMITS AND THE PAYING OF ALL REQUIRED FEES.
10. ALL DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD.
11. ALL INTERIOR FINISHES SHALL BE IN ACCORDANCE WITH ALL
APPLICABLE CODES OF THE LATEST ADOPTION.
12. ADA - TENANT BUILD OUT DESIGN HAS BEEN BASED UPON OUR
TRAINING AND UNDERSTANDING OF THE REGULATIONS AND GUIDELINES
ISSUED AS COMPONENT PARTS TO TITLE III OF THE AMERICANS WITH
DISABILITIES ACT, PUBLIC LAW 101 -336. DESIGN RESOLUTION DOES
NOT ATTEMPT TO ADDRESS POTENTIAL CONCERNS ASSOCIATES WITH
OTHER TITLES OF THE ACT THAT IMPLICATE POLICY, PROCEDURES,
AND TELECOMMUNICATIONS ISSUES.
13. ALL EXIT DOOR LOCKS SHALL BE IN ACCORDANCE WITH ALL
APPLICABLE CODES OF THE LATEST ADOPTION.
14. DOOR CLOSERS AT INTERIOR DOORS SHALL BE ADJUSTED SO THAT
THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN A DOOR SHALL
NOT EXCEED 5 LBS.
15. INTERIOR DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN
POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS
TO MOVE TO A POINT 3 IN. FROM THE LATCH TO THE LEADING EDGE
OF THE DOOR.
16. ALL MECHANICAL WORK SHALL BE IN ACCORDANCE WITH ALL
APPLICABLE CODES OF THE LATEST ADOPTION.
17. ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH ALL
APPLICABLE CODES OF THE LATEST ADOPTION.
18. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH ALL
APPLICABLE CODES OF THE LATEST ADOPTION.
19. VERIFY WITH "CORNERSTONE COMPANIES" ALL BUILDING STANDARD
MATERIALS & SYSTEMS.
REFLEC.JED GEILINO LEOEND
BUILDING STANDARD 2'x4' CEILING GRID
IIDRYWALL BULKHEAD
® BUILDING STANDARD 2x4 LAY -IN
FLUORESCENT LIGHT FIXTURE
LAad BUILDING STANDARD 2x4 LAY -IN
FLUORESCENT NIGHT -LIGHT FIXTURE
®
BUILDING STANDARD 2x2 LAY -IN
FLUORESCENT LIGHT FIXTURE
ELEGTRIGAL LEGEND
WALL MOUNTED DUPLEX OUTLET
Q�a WALL MOUNTED OUTLET FOR VIEW BOX
GFl WALL MOUNTED DUPLEX OUTLET - GFI
D WALL MOUNTED DUPLEX OUTLET - DEDICATED
O FLOOR MOUNTED OUTLET
Q WALL MOUNTED COMBINATION TELEPHONE /DATA LINE
CEILING TYPE LEGEND
EE#:TYPE
--HEIGHT
A - BUILDING STANDARD 2'X4' ACOUSTICAL CEILING TILES
B - DRYWALL CEILING
KEY PLAN .�
SIMMONS
& ASSOCIATES, INC.
ARCHITECTS, PLANNERS
305 East New York Street
Indianapolis, Indiana 46204 -5135
(317) 656 -3500 Fax (317) 656 -3501
W�
WALL MOUNTED LIGHT SWITCH
dim
WALL MOUNTED
LIGHT SWITCH - DIMMER SWITCH
9
BLDG. STD. EXIT
SIGN W/ BATTERY PACK
O
BUILDING STD.
DIFFUSER
BUILDING STD.
RETURN AIR GRILLE
Li
BUILDING STD.
EXHAUST FAN
00
d"
BUILDING STD.
RECESSED DOWNLIGHT
NL
BUILDING STD.
RECESSED DOWNLIGHT - NIGHT LIGHT
ELEGTRIGAL LEGEND
WALL MOUNTED DUPLEX OUTLET
Q�a WALL MOUNTED OUTLET FOR VIEW BOX
GFl WALL MOUNTED DUPLEX OUTLET - GFI
D WALL MOUNTED DUPLEX OUTLET - DEDICATED
O FLOOR MOUNTED OUTLET
Q WALL MOUNTED COMBINATION TELEPHONE /DATA LINE
CEILING TYPE LEGEND
EE#:TYPE
--HEIGHT
A - BUILDING STANDARD 2'X4' ACOUSTICAL CEILING TILES
B - DRYWALL CEILING
KEY PLAN .�
SIMMONS
& ASSOCIATES, INC.
ARCHITECTS, PLANNERS
305 East New York Street
Indianapolis, Indiana 46204 -5135
(317) 656 -3500 Fax (317) 656 -3501
W�
z
°o
Li
V 1
W
00
d"
N
v �
E-� o LO
W Nti
W
W
� W
W
r 0
CN CD
oo 0 o
c� ti
Li z
N
W W Q 00
LO
-A w
U Q
z
p
8!P u,
O � O
u
m m p� O rn
CER MED BY.
A'••s��i
. . N
• $ 3135 g
J
4&_N_k
IV)
U)
a
G
M
W
Q
F-
U)
v
O
p N
O
v
vs
MECH/ELEG PLANS
z
°o
Li
N
v �
� W
W
r 0
F-- C%)
Li z
z
w z
-A w
U Q
\ c
uj
0ZwWz
c):f cj::� Q
—A 0
o j