HomeMy WebLinkAboutA7.100 ® _
W
W
w
m L
N
I-
0
Q AREA "CA I "�REA wB�
U
Z
W
H
Q
N
N
a
J
C
Cc
–�
O
i.
lopep
TO
W
O
O
o��
B
V)
C
Z
C.�
ca
Q
�
C
W
C
•
•
•
■
O --
I
I
f
I
a
t`
O
Li
O
O
1
U
O
N
O
O_
I
r
Q
0
i
O
O
N
O
O_
0
U
3
d'
O
N
O
i •
I
I
I
I I
I
I
I
I
I
I
I
I '
I
I
I
AREA "CA I �REA AB"
I
r
I I 1
I I
I I i
I i I
I � I
- - - - - -
STAIR
PARTS STORAGE MEZZANINE I S -4
Fl- 2-13
1
CL.
I , 8212
I I
TRAINING SHOP
B210
I I
i
I
G
1
I
I
I
I
I
I
I
I
1
I
I
STORAGE
! B211
`\``,,,auunnrrrrr�
GENERAL NOTES. °R - -
�° (D C
E.1 _
1• FINISH FLOOR ELEVATION 100' -0" INDICATED ON ARCHITECTURAL, STRUCTURAL, '� r
MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS IS EQUAL TO USGS
ELEVATION DATUM 747.25.
2 MATERIALS, EQUIPMENT, FIXTURES, ACCESSORIES, AND ASSEMBLIES INDICATED
ON DRAWINGS ARE NEW CONSTRUCTION UNLESS SPECIFICALLY NOTED AS C,
O+AREA EXISTING.
AREA '�B� �A� 3. DIMENSIONS ARE TAKEN TO CENTERLINES OF COLUMNS AND TO FACE OF cd
MASONRY, CONCRETE, STUDS AND FURRING UNLESS INDICATED OTHERWISE. 8 0
4. PROVIDE FIRESTOPPING TO MATCH FIRE RESISTANT RATING OF EXISTING o b �
I CONSTRUCTION AT NEW PENETRATIONS THROUGH EXISTING FIRE RESISTANT
I CONSTRUCTION. W �5 z z c F
II
5. EXTEND NEW FIRE RESISTANT CONSTRUCTION TO UNDERSIDE OF DECK ABOVE.
PROVIDE FIRESTOPPING TO MATCH FIRE RESISTANT RATING OF NEW
CONSTRUCTION AT PERIMETER WHERE IT MEETS EXISTING CONSTRUCTION AND o
AT PENETRATIONS THROUGH NEW FIRE RESISTANT CONSTRUCTION. a
col tho
6. EXTEND GYPSUM WALLBOARD TO UNDERSIDE OF DECK ON ONE SIDE OF O o « �
Cs C> ::
INTERIOR METAL STUD PARTITIONS AND TO 8" ABOVE CEILING ON OTHER SIDE •� «° a
OF THE PARTITION UNLESS OTHERWISE INDICATED. FIT GYPSUM WALLBOARD . ' C; m 0
TIGHTLY AROUND PROFILE OF STRUCTURAL ELEMENTS, PIPING AND CONDUIT. b B 0 "
CALK JOINTS AROUND THESE ELEMENTS. x 9 CD
I '
7. PROVIDE DIAGONAL BRACING OF METAL STUD PARTITIONS ABOVE CEILING. 0 0
PROVIDE METAL STUD DIAGONAL BRACING OF THE SAME DIMENSION AND GAGE ° 4 a H
�� V
AS PARTITION'S CONSTRUCTION, AND SPACE DIAGONAL BRACING NO MORE THAN v° c w .�
48" ON CENTER. ATTACH DIAGONAL BRACING TO PARTITION FRAMING MEMBERS �1
Li
MENS LOCKERS z NO MORE THAN 12" ABOVE CEILING AND AT TOP CHORD, PANEL POINT OF O
B209- 1 8206 , STEEL JOISTS.
O
V1 a
I
WOMENS LOCKERS MENS bmuwtK
820 -
B208 7
e e OCY
a
r �a
I
FILE
HALL
8202
F5 M Q
I < !
MECH.
8205
STAIR M
r "
STOR. I S-3 7 -0
8204 M
- . . OC \
' MN
HALL
d
■ LUNCH ROOM
' B203
' I 42 3
■ I O � �
TELEPHONE -
■ I A224
N c)
N
lo' -'O o
v OFFICE
A211
OFFICE
q� A210
ib 0
- CD
I
CD
v
N
' EXEC.
OFFICE
CD
N a A209 0
® CD
i V I
1 I
I I
I I
I I
I 1
I 1
I I
I I
AREA "B" "�=AREA`A` SECOND FLOOR PLAN
DIMENSION
NORTH
0 0
v �
to q
aA��J+vtip
1v°
Z
Q
Q
W a:
zom
0 0 R
ZU-
W�
-
W
Z t�
00
U
W
co
oca
C
Cc
O
O
i.
cq
C
C'3
O
O
o��
D
C
Z
C.�
ca
Q
�
C
/