Loading...
HomeMy WebLinkAboutIndexScope Rotes Contractor° Responsibilities Re: All Sheets SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, EXISTING CONDITIONS, AND /OR DESIGN INTENT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ARCHITECT PRIOR TO BID SUBMITTAL AND PROCEEDING WITH ANY WORK, OR RELATED WORK, IN QUESTION. THESE CONTRACT DOCUMENTS ARE INTENDED TO DESCRIBE ONLY THE SCOPE AND APPEARANCE OF THE REAL PROPERTY IMPROVEMENTS, INCLUDING THE PERFORMANCE AND LEVEL OF QUALITY EXPECTED OF ITS COMPONENTS. IT IS INCUMBENT UPON THE CONTRACTOR TO INSURE THAT ALL WORK COMPLETED AND MATERIALS INSTALLED BE IN FULL COMPLIANCE, AS A MINIMUM STANDARD, WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES HAVING JURISDICTION. THESE CONTRACT DOCUMENTS DO NOT ATTEMPT TO INSTRUCT THE CONTRACTOR IN THE DETAILS OF HIS TRADE. THEY ARE PERFORMANCE SPECIFICATIONS IN THAT THEY DO REQUIRE THAT ALL MANUFACTURED ITEMS, MATERIALS AND EQUIPMENT BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDED SPECIFICATIONS, EXCEPT IN THE CASE WHERE THE CONTRACT DOCUMENTS ARE MORE STRINGENT. ANY MISCELLANEOUS ITEMS OR MATERIALS NOT SPECIFICALLY NOTED, BUT REQUIRED FOR PROPER INSTALLATION SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR(S). ALL WORK SHALL BE WARRANTED SATISFACTORY, IN MATERIALS AND WORKMANSHIP, FOR A MINIMUM PERIOD OF ONE (1) YEAR, OR FOR THE PERIOD OF WARRANTY CUSTOMARY, OR STIPULATED FOR, THE TRADE, CRAFT, OR PRODUCT, WHICHEVER IS LONGER. THEREFORE, ONLY COMPETENT MECHANICS CAPABLE OF PRODUCING GOOD WORKMANSHIP CUSTOMARY TO THE TRADE SHOULD BE USED. COMMENCING WORK BY A CONTRACTOR OR SUBCONTRACTOR CONSTITUTES ACCEPTANCE OF THE CONDITIONS AND SURFACE CONCERNED. IF ANY SUCH CONDITIONS ARE UNACCEPTABLE, THE GENERAL CONTRACTOR SHOULD BE NOTIFIED AT ONCE AND NO WORK DONE UNTIL CONDITIONS ARE ACCEPTABLE. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER, OR THEIR AUTHORIZED AGENT, TO DETERMINE ALL EXISTING MATERIALS TO BE SALVAGED AND RETAINED BY THE OWNER. THE CONTRACTOR SHALL REMOVE SALVAGEABLE MATERIALS FROM THE SPACE AND STORE IN A LOCATION AS DIRECTED BY THE OWNER. ALL OTHER MATERIALS , RUBBISH, AND DEBRIS, SHALL BE REMOVED AND PROMPTLY DISPOSED OF BY THE CONTRACTOR AT AN OFFSITE LOCATION. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ASSURE THAT ALL PROPERTY IMPROVEMENTS [I.E., PARTITIONS, DOORS, FRAMES, CABINETS, CEILING GRID, CEILING TILE, AND THE ELECTRICAL AND MECHANICAL DEVICES, ETC.] WHICH ARE TO REMAIN, ARE PROTECTED FROM DAMAGE OF ANY KIND. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING WORK WHICH IS TO REMAIN, AND DETERMINING WHETHER OR NOT IT CAN BE REPAIRED AND /OR RECONDITIONED TO MATCH AND BLEND WITH NEW MATERIALS AND COMPONENTS. HE SHALL OBTAIN THE OWNER'S APPROVAL OF THE SCOPE AND LIMIT OF SAID WORK PRIOR TO STARTING CONSTRUCTION. NO CHANGE ORDERS SHALL BE ACCEPTED FOR COMPLETED WORK THAT DOES NOT CONFORM TO THE STANDARDS ESTABLISHED AT THE TIME OF BID ACCEPTANCE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH THE PROJECT SCOPE OF WORK, BUILDING STANDARDS, SCHEDULE AND DEADLINES. THE CONTRACTOR SHALL FURTHER BE RESPONSIBLE FOR ADVISING THE OWNER OF ALL LONG LEAD TIME ITEMS AFFECTING THE PROJECT SCHEDULE AND SHALL, UPON REQUEST FROM THE OWNER, SUBMIT ORDER CONFIRMATIONS AND DELIVERY DATES FOR SUCH LONG LEAD TIME ITEMS TO THE OWNER. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING OWNER ACCESS TO THE SPACE AND THE ONGOING CONSTRUCTION WORK. DISRUPTIVE OR POTENTIALLY HAZARDOUS CONSTRUCTION ACTIVITIES SHALL BE COORDINATED TO OCCUR AFTER NORMAL OFFICE HOURS, SO AS TO MINIMIZE DISTURBANCE TO BUILDING OCCUPANTS. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING OWNER FOR DELIVERY TO THE SPACE OF ALL BUILDING MATERIALS, AND SHALL ARRANGE FOR USAGE OF THE FREIGHT ELEVATOR [OR SUCH ELEVATOR DESIGNATED]. IF DELIVERY OF BUILDING MATERIALS INVOLVES THE USE OF FACILITIES OTHER THEN THE AVAILABLE ELEVATORS, THE CONTRACTOR SHALL COORDINATE SUCH ACTIVITIES IN SUCH A MANNER WHICH POSES NO HAZARD TO ANY PERSONNEL WITHIN OR AROUND THE BUILDING OR BUILDING SITE. ALL CONTRACTOR OR SUPPLIER REQUESTS FOR SUBSTITUTIONS OF SPECIFIED ITEMS SHALL BE SUBMITTED IN WRITING, ACCOMPANIED BY THE ALTERNATIVE PRODUCT INFORMATION, TO THE ARCHITECT. ALL SUBSTITUTIONS SHALL BE SUBMITTED TO THE ARCHITECT, NO LATER THAN (10) WORKING DAYS PRIOR TO BID OPENING DATE. SUBSTITUTIONS SHALL ONLY BE CONSIDERED ONLY IF THEY DO NOT SACRIFICE QUALITY, APPEARANCE, AND FUNCTION. UNDER NO CIRCUMSTANCES WILL THE OWNER BE REQUIRED TO PROVE THAT A PRODUCT PROPOSED FOR SUBSTITUTION IS OR IS NOT OF EQUAL QUALITY TO THE PRODUCT SPECIFIED. UNDER NO CIRCUMSTANCES SHALL THE CONTRACTOR SCALE THE DRAWINGS TO DETERMINE THE DIMENSIONS. SEE FLOOR PLAN FOR DIMENSION LOCATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF ALL SELECTED MATERIALS WHICH SHALL BE COMPLETE IN ALL RESPECTS PRIOR TO THE FINAL ACCEPTANCE, UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL PRESERVE ALL PRINTED INSTRUCTIONS AND WARRANTIES THAT ARE PROVIDED WITH EQUIPMENT OR MATERIALS USED, AND DELIVER SAID PRINTED MATTER TO THE OWNER AT THE TIME OF SUBSTANTIAL COMPLETION. THE CONTRACTOR SHALL INSTRUCT THE OWNER OR OWNER'S REPRESENTATIVE IN THE PROPER PROPER USE OF THE EQUIPMENT FURNISHED BY THEIR TRADE. GENERAL CONTRACTOR IS TO PROVIDE A THOROUGH CONSTRUCTION CLEAN —UP AT CLOSE —OUT, INCLUDING VACUUMING AND CLEANING ALL CARPETING. Design Compliance Review Re: All Sheets THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF CUSTOM MILLWORK, CUSTOM FABRICATION OR MANUFACTURE, AND PHYSICAL SAMPLES OF ALL FINISH MATERIALS SPECIFIED TO THE ARCHITECT FOR REVIEW AND APPROVAL BY THE OWNER. REVIEWED SHOP DRAWINGS AND SCHEDULES PREPARED BY OTHERS SHALL NOT BE CONSTRUED TO BE PART OF THE CONTRACT DOCUMENTS, AS THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR DRAWINGS, SCHEDULES AND /OR SPECIFICATIONS FOR WORK ON THE PROJECT PREPARED OR ACCOMPLISHED BY OTHERS. THE ARCHITECT WILL REVIEW THE DRAWINGS AND SAMPLES FOR CONFORMITY WITH THE INFORMATION CONTAINED IN THE CONSTRUCTION DOCUMENTS, AND RETURN THE SUBMITTALS TO THE CONTRACTOR WITHIN FIVE (5) WORKING DAYS OF RECEIPT, EXCEPT AS MAY OTHERWISE BE PROVIDED Existing Conditions Change Orders Re: All Sheets EXISTING CONDITIONS SHOWN ON THESE DRAWINGS ARE BASED UPON BASE BUILDING OR OTHER CONSTRUCTION DOCUMENTS MADE AVAILABLE TO THE ARCHITECT BY THE BUILDING OWNER. UNLESS OTHERWISE NOTED, AS —BUILT ARCHITECTURAL CONDITIONS HAVE NOT BEEN FIELD VERIFIED AND MAY VARY FROM THOSE SHOWN. PRIOR TO SUBMITTING THE CONSTRUCTION BID, THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING CONDITIONS AND ANY CRITICAL DIMENSIONS ASSOCIATED WITH THE PROPOSED WORK. THE CONTRACTOR SHALL CONFIRM THAT ALL WORK OUTLINED WITHIN THESE DOCUMENTS MAY BE ACCOMPLISHED AS SHOWN, PRIOR TO THE COMPLETION OF THE BIDDING PROCESS, AND SHALL NOTIFY BOTH THE ARCHITECT AND THE BUILDING OWNER OF ANY CONDITIONS ENCOUNTERED WHICH MAY EFFECT BUILDING CODE COMPLIANCE. LIFE SAFETY AND ISSUANCE OF A CERTIFICATE OF OCCUPANCY, THE TIMELY COMPLETION FOR THE PROJECT OR ESTABLISHED BUDGET OF SUCH WORK. NO ADDITIONAL FUNDS WILL BE APPROVED FOR WORK OMITTED FROM THE CONSTRUCTION BID DUE TO LACK OF VERIFICATION BY THE CONTRACTOR, EXCEPT AS OTHERWISE APPROVED BY THE OWNER FOR WORK ASSOCIATED WITH "HIDDEN* CONDITIONS NOT ACCESSIBLE PRIOR TO CONSTRUCTION. FOR BY THE OWNER. NEW PARTITIONS TO BE CONSTRUCTED DESIGNATES INTERIOR WALL CONST. X TYPES. REFER TO FLOOR PLANS FOR LOCATIONS. REFER TO WALL TYPES ON THIS SHEET FOR ACTUAL WALL CONSTRUCTI NOTE: ALL WALLS ARE W1 UNLESS OTHERWISE NOTED. i1f AM I HIM I EEW 90 DENOTES ONE HOUR RATED CONSTRUCTION. Electricai E101 ELECTRICAL SITE PLAN E102 STANDARD SYMBOL LEGEND E201 LIGHTING PLAN E301 POWER PLAN E401 ONE —LINE DIAGRAM & PANEL SCHEDULES. Wall Type Rotes NOTE; PROVIDE CONTROL JOINTS IN ALL METAL STUD/ GYP BOARD WALLS AT 30' -0" MAXIMUM SPACING. AT RATED WALLS STUFF CONTROL JOINT FULL WITH SOUND ATTENUATION FIRE BLANKET. REFER TO FLOOR PLANS FOR LOCATION OF EACH INDIVIDUAL WALL TYPE. WALL TYPE #5 ONE HOUR RATED ASSEMBLY TYPICAL WALL TYPES SHEETINDEAw COVER SHEET INDEX SHEET A.F.F. kchitecfi ra; A1.1 FLOOR PLAN, REFLECTED CEILING PLAN A1.2 MISC DETAILS A1.3 MISC DETAILS A2.1 ROOF PLAN A3.1 EXTERIOR ELEVATIONS A5.1 EXTERIOR WALL SECTIONS A5.2 EXTERIOR WALL SECTIONS A5.3 EXTERIOR WALL SECTIONS A5.4 EXTERIOR WALL SECTIONS A5.5 EXTERIOR WALL SECTIONS A5.6 EXTERIOR WALL SECTIONS A5.7 EXTERIOR WALL SECTIONS A5.8 ENLARGED DETAILS A5.9 DUMPSTER ENCLOSURE DETAILS A6.1 STOREFRONT FRAMING ELEVATIONS A6.1 DOOR AND WINDOW SCHEDULES FD structural S101 FOUNDATION PLAN S201 INTERMEDIATE FRAMING PLAN S301 ROOF FRAMING PLAN S401 GENERAL NOTES, SECTIONS & DETAILS S402 SECTIONS AND DETAILS Electricai E101 ELECTRICAL SITE PLAN E102 STANDARD SYMBOL LEGEND E201 LIGHTING PLAN E301 POWER PLAN E401 ONE —LINE DIAGRAM & PANEL SCHEDULES. Wall Type Rotes NOTE; PROVIDE CONTROL JOINTS IN ALL METAL STUD/ GYP BOARD WALLS AT 30' -0" MAXIMUM SPACING. AT RATED WALLS STUFF CONTROL JOINT FULL WITH SOUND ATTENUATION FIRE BLANKET. REFER TO FLOOR PLANS FOR LOCATION OF EACH INDIVIDUAL WALL TYPE. WALL TYPE #5 ONE HOUR RATED ASSEMBLY TYPICAL WALL TYPES _ . 7 - -- •off -_T= SiteXY11l T1 TITLE SHEET C2 LAYOUT PLAN & DETAILS /SPECIFICATIONS C3 GRADING & DRAINAGE PLAN & SPECIFICA C4 UTILITY PLAN AND DETAILS C5 LANDSCAPE PLAN AND DETAILS TYP TYPICAL METROPOLITAN INDIANAPOLIS 11 60ft hn it rili ; N® Scale —,gam V7, : • -_ - . . : e: ` .XZ - 8". :.4 ., v,_ . ATTACH STUDS TO UNDERSIDE OF DECK. PROVIDE CONTINUOUS SEAL AT JOINT SUSPENDED ACOUSTICAL CEILING TILE. FILL WALL SOLID WITH SAFB(2.5 PCF) INSULATION IN THICKNESS TO MATCH REQUIRED METAL STUD SIZE. FLOOR LINE NOT ALL MAY APPLY NO SCALE Symbol Legend O KEYED NOTE REFER SHEET WHERE SHOWN. X WALL TYPE. SEE PLANS FOR LOCATION SEE THIS SHEET FOR CONSTRUCTION. O DOOR NUMBER. REFER TO DOOR SCHEDULE W1 WINDOW NUMBER. REFER TO WINDOW SCHEDULE OFFICE ROOM NAME, SIZE AND NUMBER. REFER 1O61 TO ROOM FINISH SCHEDULE ELEVATION NUMBER SHEET NUMBER SECTION NUMBER SHEET NUMBER X ENLARGED PLAN 1 1 OFINISH NOTE. REFER TO ROOM FINISH LEGEND ® REVISION ELEVATION TARGET SEMI RECESSED FIRE EXTINGUISHER/ ® CABINET TO BE PROVIDED /INSTALLED BY F.E. G.C., SEE DETAIL THIS SHEET. PAINT CABINET TO MATCH DOOR FRAMES. FIRE EXTINGUISHERS ARE BY OWNER. _ Document Approval Client /Tenant Date Title Property Manager Date Carson Design Associates Date UPON EXECUTION, THE CLIENT AND PROPERTY MANAGER APPROVE ALL ASPECTS OF THE SCOPE OF WORK SHOWN IN THESE DOCUMENTS, INCLUDING DESIGN CONTENT, SCOPE OF CONSTRUCTION AND FINISH SELECTION FOR THE FOLLOWING PHASE: F1 SPACE PLANNING PRELIMINARY PRICING F1 CONSTRUCTION DOCUMENTATION ALL COSTS INCURRED DUE TO MISINTERPRETATION OF THESE DOCUMENTS OR ANY CHANGES TO THE PROJECT REQUESTED AFTER SIGN —OFF SHALL NOT BE THE RESPONSIBILITY OF CARSON DESIGN ASSOCIATES AND SHALL BE THE SOLE RESPONSIBILITY OF THE CLIENT. x *' CARSON DESIGN ASSOCIATES TEL 317.843.5979 FAX 317.8435975 11590 M MERIDIAN SUITE 104 CARMEL INDLANA 46032 TEL 512977.0520 FAX 512.977.0384 4201 W. PARMER LANE SUITE 104 AUSTIN TEXAS 78727 wwwxarsondeeTpxom CLIENT - DEVELOPER Lo THE INDER COMPANY STAMP ��.��` ►'►����►�,,,,�� N o. • 9600043 • _= STATE aF 3 71RES 11/30/01 Am cc � Q W Q� L.0 Uj Z Q N U CODti O ISSUE: NOVEMBER 5,2001 RELEASED FOR PERMITS SQUARE FOOTAGE: DRAWING Inde,A%ff Shend ___ - -,'W' ._.. JOB NO. DATE: 3. a 9940015 NOVEMBER 5,2001 SHEET NUMBER: 0 N 7 O M Abbreviations A.F.F. ABOVE FINISHED FLOOR FD FLOOR DRAIN OD OUTSIDE DIAMETER UON UNLESS OTHERWISE NOTED ACT ACOUSTICAL CEILING TILE FIN FINISH OPNG OPENING UR URINAL APP APPROXIMATE FLR FLOOR OPP OPPOSITE VCT VINYL COMPOSITION TILE AWT ACOUSTICAL WALL TREATMENT FT FEET O.H. OPPOSITE HAND VERT VERTICAL BLKG BLOCKING FD FLOOR DRAIN 0 TO 0 OUT TO OUT VT VINYL TILE B.O. BOTTOM OF FE FIRE EXTINGUISHER PLAS LAM PLASTIC LAMINATE W� WITH BOT BOTTOM FEC FIRE EXTINGUISHER CABINET PLWD PLYWOOD W/0 WITHOUT PS PROJECTION SCREEN CAB CABINET GA GAUGE WB WOOD BASE CAR CARPET GB GRAB BAR QT QUARRY TILE WC WATER CLOSET CJ CONTROL JOINT GWB GYPSUM WALLBOARD R RISER WD WOOD CL CENTER LINE RA RETURN AIR WH WATER HEATER CMU CONCRETE MASONRY UNIT HDWR HARDWARE RB RESILIENT BASE WP WORKING POINT COL COLUMN HM HOLLOW METAL REF REFERENCE CONC CONCRETE HORIZ HORIZONTAL REFR REFRIGERATOR CONST CONSTRUCTION HVAC HEATING, VENTILATING, AIR COND. READ REQUIRED CONT CONTINUOUS HW HOT WATER RO ROUGH OPENING CT CERAMIC TILE JST JOIST CW COLD WATER JT JOINT SA SUPPLY AIR SCHED SCHEDULE DET DETAIL KIT KITCHEN SEC SECTION DF DRINKING FOUNTAIN LAM LAMINATE SIM SIMILAR DIM DIMENSION LAV LAVATORY SPECS SPECIFICATIONS DWG DRAWING LLH LONG LEG HORIZONTAL SF SQUARE FOOT DWC DRINKING WATER COOLER LLV LONG LEG VERTICAL SA SUPPLY AIR EA EACH MAS MASONRY SS STAINLESS STEEL EJ EXPANSION JOINT MAX MAXIMUM STD STANDARD EL ELEVATION MB MARKER BOARD STL STEEL EIFS EXTERIOR INSULATION FINISH SYSTEM MECH MECHANICAL SUSP SUSPENDED EXIS EXISTING MEZZ MEZZANINE TB TACK BOARD EXP EXPANSION MFR MANUFACTURER TEL TELEPHONE EXP EXTERIOR MIN MINIMUM T.O. TOP OF M.0_ MASONRY OPENING TV TELEVISION _ . 7 - -- •off -_T= SiteXY11l T1 TITLE SHEET C2 LAYOUT PLAN & DETAILS /SPECIFICATIONS C3 GRADING & DRAINAGE PLAN & SPECIFICA C4 UTILITY PLAN AND DETAILS C5 LANDSCAPE PLAN AND DETAILS TYP TYPICAL METROPOLITAN INDIANAPOLIS 11 60ft hn it rili ; N® Scale —,gam V7, : • -_ - . . : e: ` .XZ - 8". :.4 ., v,_ . ATTACH STUDS TO UNDERSIDE OF DECK. PROVIDE CONTINUOUS SEAL AT JOINT SUSPENDED ACOUSTICAL CEILING TILE. FILL WALL SOLID WITH SAFB(2.5 PCF) INSULATION IN THICKNESS TO MATCH REQUIRED METAL STUD SIZE. FLOOR LINE NOT ALL MAY APPLY NO SCALE Symbol Legend O KEYED NOTE REFER SHEET WHERE SHOWN. X WALL TYPE. SEE PLANS FOR LOCATION SEE THIS SHEET FOR CONSTRUCTION. O DOOR NUMBER. REFER TO DOOR SCHEDULE W1 WINDOW NUMBER. REFER TO WINDOW SCHEDULE OFFICE ROOM NAME, SIZE AND NUMBER. REFER 1O61 TO ROOM FINISH SCHEDULE ELEVATION NUMBER SHEET NUMBER SECTION NUMBER SHEET NUMBER X ENLARGED PLAN 1 1 OFINISH NOTE. REFER TO ROOM FINISH LEGEND ® REVISION ELEVATION TARGET SEMI RECESSED FIRE EXTINGUISHER/ ® CABINET TO BE PROVIDED /INSTALLED BY F.E. G.C., SEE DETAIL THIS SHEET. PAINT CABINET TO MATCH DOOR FRAMES. FIRE EXTINGUISHERS ARE BY OWNER. _ Document Approval Client /Tenant Date Title Property Manager Date Carson Design Associates Date UPON EXECUTION, THE CLIENT AND PROPERTY MANAGER APPROVE ALL ASPECTS OF THE SCOPE OF WORK SHOWN IN THESE DOCUMENTS, INCLUDING DESIGN CONTENT, SCOPE OF CONSTRUCTION AND FINISH SELECTION FOR THE FOLLOWING PHASE: F1 SPACE PLANNING PRELIMINARY PRICING F1 CONSTRUCTION DOCUMENTATION ALL COSTS INCURRED DUE TO MISINTERPRETATION OF THESE DOCUMENTS OR ANY CHANGES TO THE PROJECT REQUESTED AFTER SIGN —OFF SHALL NOT BE THE RESPONSIBILITY OF CARSON DESIGN ASSOCIATES AND SHALL BE THE SOLE RESPONSIBILITY OF THE CLIENT. x *' CARSON DESIGN ASSOCIATES TEL 317.843.5979 FAX 317.8435975 11590 M MERIDIAN SUITE 104 CARMEL INDLANA 46032 TEL 512977.0520 FAX 512.977.0384 4201 W. PARMER LANE SUITE 104 AUSTIN TEXAS 78727 wwwxarsondeeTpxom CLIENT - DEVELOPER Lo THE INDER COMPANY STAMP ��.��` ►'►����►�,,,,�� N o. • 9600043 • _= STATE aF 3 71RES 11/30/01 Am cc � Q W Q� L.0 Uj Z Q N U CODti O ISSUE: NOVEMBER 5,2001 RELEASED FOR PERMITS SQUARE FOOTAGE: DRAWING Inde,A%ff Shend ___ - -,'W' ._.. JOB NO. DATE: 3. a 9940015 NOVEMBER 5,2001 SHEET NUMBER: 0 N 7 O M