Loading...
HomeMy WebLinkAboutA1.1OF WALL U.N.O. PCz -503 � 32m e ' 't TYP. 2m5 ELEVATOR L0"r L VAT ION SCALE: 1/411 11_011 ELEVATOR L 1 i=LAN pETAIL Iii �- SCALE: 1/4" = 11 -011 HEARING 11— IFAIRED �I�ESTROOM ADA COl" IFL IANT �I,�ESTROOM NOT IN CONTRACT 1 AREAS 1REFER TO SHEETS j A -2.1, A3.1, A3.2 4 A33 FOR ALL RENOVATION INFORI"iATION IN THESE AREAS REFER TO SHEET A4.2 FOR ALL t"lEETING ROOM RENOVATION INFORMATION r — — IIII 1 OF WALL U.N.O_ PG -503 PG -202 a 32m T 2m5 ELEVATOR L055"r ELEVAT ION SCALE: 114" = 11_011 1 A43 PG -202 PG-500 313 8 4 -1 _____ = = = =AL ELEVATOR L05`' #1 KLAN DETAIL SCALE: 1/4" = 11 -011 7- LIMLM II 71� i 1 I 11I Il ' V-7- � A­ " fi /L TF-r° J u III 1 ►��1 1 1111= � 7 I F I R5T FLOOR U 5TROO1„C CORRIDOR FLAN SCALE: 1116" = 11 -011 I M ELEVATION SCALE: 1/4" = 11_011 CONTRASTING CARPET STRIPS AT TOP AND BOTTOM (TYP.) 15T FLOOR 5TAIRWELL A.II A• I *I=-', �=*= A t 1 SCALE: 1/4" = 11_011 W EXERCISE ROOM CORRIDOR (TYPICAL) 1 -1 2 -1 2 -1 11 2-4 2 -9 I -2 2 -2 2 -8 1 -2 2 -5 3 -1 1 -1 1 -8 2 -4 1 -1 1 -9 2 -1 1 -3 2 -3 2 -9 I -3 2 -6 4 -1 1 -2 1 -9 2 -10 1 -2 2 -1 2 -8 1 -4 2 -4 2 -II 1 -3 2 -1 2 -11 1 -5 2 -2 2 -11 1 -5 2 -5 3 -1 2 -I 2 -1 4 -2 1 -5 2 -2 2 -12 I -6 2 -6 4 -I 2 -3 2 -5 4 -3 1 -6 2 -3 3 -1 1 -1 2 -3 3 -1 4 -3 1 -5 2 -4 3-5 2 -5 4 -6 STAIRS (TYPICAL) o 1 MN GUEST LAUNDRY 205 T*VDIGAL <EYNOTE5 -1 2 -3 2 -1 1 -2 2 -4 1 1 -3 p1 2 -5 3 -2 - DIMENSIONS ARE TO FACE OF FINISH UNO. REFER TO FIN15H INDEX FOR MORE INFORMATION 2 -1 2 -6 4 -4 CEILINGS: - CLEAN ALL ELECTRICAL DEVICES TO REMAIN. PROTECT DURING NEW SURFACE MOUNTED LIGHT FIXTURE IN SAME LOCATION AS 1 -1 EXISTING FIRE PROTECTION DEVICES TO REMAIN. PROTECT DURING CONSTRUCTION. CONNECTIONS. 140 GG GC CONSTRUCTION. - REMOVE ALL CIRCULINE BULBS FROM REMOVED LIGHT FIXTURES. RECESSED FIXTURE BETWEEN EVERY SURFACE MOUNTED 1 -2 EXISTING SPEAKER GRILLES TO REMAIN. PROTECT DURING CONTRACTOR TO LIQUIDATE OR DISPOSE OF OLD BULBS. ACCOMODATE NEW LOAD. PROVIDE ALL REQUIRED CONSTRUCTION. - WORK SHALL INCLUDE PROVIDING SEALANT AS PER PROVIDE ALLOWANCE TO REPLACE 5% OF EXISTING 1 -3 15T FLOOR 5TAIRWELL A.II A• I *I=-', �=*= A t 1 SCALE: 1/4" = 11_011 W EXERCISE ROOM CORRIDOR (TYPICAL) 1 -1 2 -1 2 -1 11 2-4 2 -9 I -2 2 -2 2 -8 1 -2 2 -5 3 -1 1 -1 1 -8 2 -4 1 -1 1 -9 2 -1 1 -3 2 -3 2 -9 I -3 2 -6 4 -1 1 -2 1 -9 2 -10 1 -2 2 -1 2 -8 1 -4 2 -4 2 -II 1 -3 2 -1 2 -11 1 -5 2 -2 2 -11 1 -5 2 -5 3 -1 2 -I 2 -1 4 -2 1 -5 2 -2 2 -12 I -6 2 -6 4 -I 2 -3 2 -5 4 -3 1 -6 2 -3 3 -1 1 -1 2 -3 3 -1 4 -3 1 -5 2 -4 3-5 2 -5 4 -6 STAIRS (TYPICAL) o 1 MN GUEST LAUNDRY 205 T*VDIGAL <EYNOTE5 -1 2 -3 2 -1 1 -2 2 -4 2 -14 1 -3 p1 2 -5 3 -2 - DIMENSIONS ARE TO FACE OF FINISH UNO. REFER TO FIN15H INDEX FOR MORE INFORMATION 2 -1 2 -6 4 -4 u TYP_ T�'R. GU 5TROOM *4E NTR"� ELEVATION SCALE: 1/4f1 = 11 -0" TAG O � O O L � I, T*'�f'. GU5TROO`l NTR"r 1PLAN DETAIL SCALE: 1 /411 = 11_011 N FINISH CODES 205 T*VDIGAL <EYNOTE5 5aHEET NOTE5: PAINT 3113 VINYL WALLCOVERING - ACCENT 320 VINYL WALLCOVERING DEMOLITION NOTES: x -x - DIMENSIONS ARE TO FACE OF FINISH UNO. REFER TO FIN15H INDEX FOR MORE INFORMATION HMB - ALL EXTERIOR CORNERS ARE TO RECEIVE CORNER GUARDS. 1 -4 OW OW CEILINGS: - CLEAN ALL ELECTRICAL DEVICES TO REMAIN. PROTECT DURING NEW SURFACE MOUNTED LIGHT FIXTURE IN SAME LOCATION AS 1 -1 EXISTING FIRE PROTECTION DEVICES TO REMAIN. PROTECT DURING CONSTRUCTION. CONNECTIONS. 140 GG GC CONSTRUCTION. - REMOVE ALL CIRCULINE BULBS FROM REMOVED LIGHT FIXTURES. RECESSED FIXTURE BETWEEN EVERY SURFACE MOUNTED 1 -2 EXISTING SPEAKER GRILLES TO REMAIN. PROTECT DURING CONTRACTOR TO LIQUIDATE OR DISPOSE OF OLD BULBS. ACCOMODATE NEW LOAD. PROVIDE ALL REQUIRED CONSTRUCTION. - WORK SHALL INCLUDE PROVIDING SEALANT AS PER PROVIDE ALLOWANCE TO REPLACE 5% OF EXISTING 1 -3 EXISTING SPRINKLER HEADS TO REMAIN. PROTECT DURING SPECIFICATIONS. ONE CONTIGUOUS AREA. GG TO SHUFFLE EXISTING TILES TO CONSTRUCTION. GG TO VERIFY COMPLIANCE WITH CODES. - FINISH FACE OF NEW WALLS TO ALIGN WITH EXISTING AS CLEAN PRE /REPAIR AND PAINT EXISTING HVAC GRILLES, 1 -4 EXISTING ACT AND GRID TO REMAIN. PROTECT DURING RE OU I RED. NEW ACT TILES AND GRID WALLS: CONSTRUCTION. 5 NEW GRAPHICS PACKAGE. INSTALL TO CORRECT ADA 1 -5 EXISTING SMOKE DETECTORS, EXIT SIGNS AND GRILLES/VENTS TO - NEW WALL CONSTRUCTION TO BE (1) LAYER 8" GYPSUM BOARD NEW FULL HEIGHT CORNER GUARDS AT ALL EXPOSED REMAIN. PROTECT DURING CONSTRUCTION. ON BOTH SIDES OF 25 GAUGE METAL STUDS (3- 5 "UNO) OR WOOD NEW VINYL WALL COVERING. 1 -6 EXISTING LIGHTING TO REMAIN, GLEAN LENS. PROTECT DURING STUDS IF ALLOWABLE PER CONSTRUCTION TYPE. USE MOISTURE ALL SWITCHES, RECEPTACLES, CABLE AND PHONE DATA CONSTRUCTION. RESISTANT GYPSUM BOARD AT BATHROOM LOCATIONS. NEW SILENCERS AND SMOKE SEALS AT ALL DOORS- 1 -1 REMOVE EXISTING SURFACE MOUNTED LIGHTING AT ACT CEILINGS. - ARTWORK AND WALL MOUNTED LIGHT FIXTURES TO BE PREP AND PAINT ALL HOLLOW METAL DOOR FRAMES AND REROUTE ELECTRICAL TO ACCOMMODATE NEW LIGHTING. COORDINATED WITH OWNER'S REPRESENTATIVE. DO NOT INSTALL ELECTRICAL CABINETS AND FIRE EXTINGUISHER CABINETS, 1 -8 REMOVE EXISTING WINDOW TREATMENTS AND HARDWARE. ITEMS WITHOUT ON -SITE COORDINATION WITH INTERIOR DESIGNER. AND DOOR FINISH. PUTTY AND SAND TO PROVIDE LIKE -NEW PATCH /PREP /REPAIR ALL AFFECTED AREAS. - PROVIDE BLOCKING FOR ALL ACCESSORIES. NEW CARPET BASE AT CARPET FLOOR AREAS. 1 -9 REMOVE EXISTING ACT AND GRID, PREP TO RECEIVE NEW. EXISTING - WHERE EXISTING TUB AND TILE SURROUND ARE TO REMAIN, PATCH /PREP/REPAIR ALL AFFECTED AREAS. 2 -10 GG GC SUPPLY/ RETURN GRILLES, LOVERS AND FIRE PROTECTION DEVICES PROVIDE TUB PROTECTION USING PRE - FORMED DISPOSABLE INCLUDING: STRINGERS, PICKETS, SPRINKLER PIPING AND TO REMAIN IN CURRENT LOCATION. PVC TUB LINERS. TUB LINERS TO BE TAPED IN PLACE BEFORE PREPARE WINDOW SILLS AND APPLY WOOD ENHANCER TO WALLS: RESTORE TO LIKE -NEW FINISH AS NEEDED. ANY DEMOLITION WORK IS STARTED. OMIT. 2 -1 EX15TING FIRE ALARM PANEL, EMERGENCY EXIT SIGNS, EMERGENCY - CONTRACTOR TO REMOVE AND STORE ALL GUESTROOM ITEMS FIRST FLOOR STAIRCASES. CONSTRUCTION TO BE 3 9" METAL LIGHT FIXTURES, FIRE PULL STATIONS, BATTERY PACKS, AND TO BE REUSED UPON COMPLETION OF RENOVATION. OWNER TO FIGURE 8 ON SHEET HCI.2 FOR ADA COMPLIANCE THERMOSTATS TO REMAIN. PROTECT DURING CONSTRUCTION. SPECIFY ITEMS TO BE SAVED. CONTRACTOR TO PLACE AND RELAMINATE EXISTING FOLDING TABLE AS SPECIFIED. 2 -2 REMOVE EXISTING COVER PLATES AT ELECTRICAL DEVICES. PREP TO INSTALL ALL FURNITURE AND FIXTURES. FURNITURE AND FIXTURE COVER ROOF ACCESS DOOR AND TORE HUNG ON THE WALL RECEIVE NEW TO MATCH COLOR OF EXISTING DEVICE. PLACEMENT SHALL BE APPROVED OWNER REP. TO ROOF DOOR_ 2 -3 REMOVE EXISTING WALL FINISHES, INCLUDING BUT NOT LIMITED TO: - EXISTING SPRINKLER HEADS, SMOKE DETECTORS, FIRE ALARM NEW CARPET AND PAD. (,NOTEI: NO NEW PAD AT VINYL WALL COVERING, WALL BASE, SIGNAGE /GRAPHICS, CORNER HORN D3 =VIGES AND PTAG UNITS TO REMAIN, UNLESS NOTED FFE OR MILLWORK PIECES AS REQUIRED.) 3 -2 GG GG GUARDS, ETC., AND ADHE51VE5 TO ORIGINAL SUBSTRATE. UNLESS OTHERWISE. PROTECT DURING CONSTRUCTION- NEW CARPET AT LANDINGS, RISERS AND TREADS. 3 -4 GG GG OTHERWISE NOTED. DO NOT ALLOW THE PAPER SURFACE OF THE - AT ALL NEW AND RESTORATION TILE INSTALLATIONS, APPLY A CODE. 3 -5 GC GC DRYWALL TO BE TORN. PATCH /PREP/REPAIR/SKIM GOAT ALL GOAT OF SEALER TO TILE AND GROUT JOINTS. INFORMATION.) 340 GC GC AFFECTED AREAS. ALLOW FOR 10% NEW SKIM GOAT IN GENERAL - TAG NOTES IDX -XXX INDICATE THE MILLWORK FF4E SPECIFICATIONS. MISCELLANEOUS: AREAS. IDENTIFICATION CODE. NEW ARTWORK 2 -4 EXISTING WOOD BUMPER RAIL TO REMAIN. PROTECT DURING - FOR TYPICAL MOUNTING HEIGHTS, REFER TO SHEET HG -1.2. REINSTALL EXISTING EXERCISE EQUIPMENT AT EXERCISE CONSTRUCTION. 4 -4 - GC REINSTALL EXISTING WASHER AND DRYER UNITS AT GUEST 2 -5 EXISTING WALL MOUNT TV TO REMAIN. PROTECT DURING 4 -5 OW GG NEW FRAMED MIRROR 4 -6 OW GG CONSTRUCTION. 240 RELOCATE EXISTING HOUSE PHONE. TO BE 48" AFF. PATCH/PREP/REPAIR ALL AFFECTED AREAS. 2 -1 EXISTING WALL MIRRORS TO REMAIN. PROTECT DURING FINISH CODES 205 CARPET BASE 313 PAINT 3113 VINYL WALLCOVERING - ACCENT 320 VINYL WALLCOVERING 352 CORNER GUARD REFER TO FIN15H INDEX FOR MORE INFORMATION CONSTRUCTION. 2 -8 EXISTING PTAC UNIT TO REMAIN. PROTECT DURING CONSTRUCTION. 2 -13 EXISTING M015TURE DAMAGE AT PTAG UNIT. USE ALL NEEDED MEANS TO REMEDIATE PROBLEM. 2 -10 EXISTING WINDOW BILL FINISH TO REMAIN. PROTECT DURING CONSTRUCTION. 2 -11 REMOVE EXISTING GRAPHICS. PROTECT DURING CONSTRUCTION. PATCH /PREP /REPAIR ALL AFFECTED AREAS. 2 -12 REMOVE ALL EXISTING 5IGNAGE MOUNTED ON DOORS. (*NOTE: INCLUDING STAIR DESCRIPTION.) PATCH /PREP/REPAIR ALL AFFECTED AREAS. 2 -13 REMOVE EXISTING SECURINTY EYE/BUTTON AT INTERIOR DOOR FRAMES. PATCH/PREP/REPAIR ALL AFFECTED AREAS. FLOORS: 3 -1 REMOVE EXISTING CARPET FLOOR FINISH INCLUDING ADHESIVES, EXISTING WALL BASE AND PAD. (NOTE*; WHERE APPLICABLE, RETAIN EXISTING TACK STRIPS AS POSSIBLE FOR REUSE.) 3 -2 EXISTING FLOOR FINISH AND WALL BASE TO REMAIN. PROTECT DURING CONSTRUCTION. 3 -3 REMOVE EXISTING TRANSITION STRIP AT CARPET TO TILE LOCATIONS. PREP TO RECEIVE NEW. 3 -4 REMOVE EXISTING CARPET AT LANDING, RISERS AND TREADS INCLUDING RUBBER NOSING. PREP TO RECEIVE NEW. 3 -5 OMIT. 3 -6 REMOVE EXISTING TRANSITION. MISCELLANEOUS: 4 -1 EXISTING EXERCISE EQUIPMENT TO REMAIN. REMOVE /STORE AND PROTECT FOR REINSTALLATION UPON COMPLETION OF OTHER WORK 4 -2 EXISTING WASHER AND DRYER UNITS TO REMAIN. REMOVE /STORE AND PROTECT FOR REINSTALLATION UPON COMPLETION OF OTHER WORK, 4 -3 REMOVE EXISTING FFE. NEW CONSTRUCTION NOTES: X-X nll NH WI ISSUE FOR PERMIT CEILINGS: 05/16/2006 1 -1 GC GG CAULK JOINT AT ACT GRID AND VWC. 1 -2 GC GC PATCH/PREP AND PAINT EXISTING GWB OR NON -ACT No. CEILING, BULKHEADS AND SOFFITS. 1 -3 GG GG PAINT ALL EXISTING STEEL GRILLES AND DIFFUSERS AT HMB CEILING. 1 -4 OW OW NEW WINDOW TREATMENTS AND HARDWARE. 1 -5 OW GG NEW SURFACE MOUNTED LIGHT FIXTURE IN SAME LOCATION AS PREVIOUS. PROVIDE ALL REQUIRED ELECTRICAL CONNECTIONS. 140 GG GC NEW RECESSED LIGHT FIXTURE(S), (1) EVENLY SPACED RECESSED FIXTURE BETWEEN EVERY SURFACE MOUNTED FIXTURE. GG TO VERIFY ELECTRICAL PANEL CAN ACCOMODATE NEW LOAD. PROVIDE ALL REQUIRED ELECTRICAL AND CONNECTIONS. 1 -1 GC GG PROVIDE ALLOWANCE TO REPLACE 5% OF EXISTING DAMAGED ACT. (*NOTE: ALL NEW TILE TO BE LOCATED AT ONE CONTIGUOUS AREA. GG TO SHUFFLE EXISTING TILES TO MINIMIZE ANY OBVIOUS COLOR CHANGE BETWEEN TILES.) 1 -8 GC GC CLEAN PRE /REPAIR AND PAINT EXISTING HVAC GRILLES, ACCESS PANELS AND SPEAKERS. 1 -9 GG GG NEW ACT TILES AND GRID WALLS: 2 -1 OW GC NEW GRAPHICS PACKAGE. INSTALL TO CORRECT ADA COMPLIANT HEIGHTS AT WALLS AND /OR DOORS. 2 -2 GC GC NEW FULL HEIGHT CORNER GUARDS AT ALL EXPOSED CORNERS. 2 -3 OW GG NEW VINYL WALL COVERING. 2 -4 GG GG NEW COVERPLATES AT ALL ELECTRICAL DEVICES INCLUDING ALL SWITCHES, RECEPTACLES, CABLE AND PHONE DATA JACKS. COLOR TO MATCH EXISTING DEVICE. 2 -5 GC GG NEW SILENCERS AND SMOKE SEALS AT ALL DOORS- 2-6 GC GG PATCH/PREP AND PAINT EXISTING TEXTURED GWB WALLS. 2 -1 GC GC PREP AND PAINT ALL HOLLOW METAL DOOR FRAMES AND ALL OTHER HOLLOW METAL ITEMS (IE: ACCESS DOORS, ELECTRICAL CABINETS AND FIRE EXTINGUISHER CABINETS, ETC.). MASK AND PROTECT THE EXISTING DOOR HARDWARE AND DOOR FINISH. PUTTY AND SAND TO PROVIDE LIKE -NEW FINISH AT DOOR FRAMES. 2 -8 OW GG NEW CARPET BASE AT CARPET FLOOR AREAS. 2 -13 GC GC RELOCATE EXISTING HOUSE PHONE TO BE 48" AFF PATCH /PREP/REPAIR ALL AFFECTED AREAS. 2 -10 GG GC PREP AND PAINT ALL EXPOSED METAL SURFACES, INCLUDING: STRINGERS, PICKETS, SPRINKLER PIPING AND NON - ALUMINUM HARDWARE. 2 -11 GG GG PREPARE WINDOW SILLS AND APPLY WOOD ENHANCER TO RESTORE TO LIKE -NEW FINISH AS NEEDED. 2 -12 GC GG OMIT. 2 -13 GC GG BUILD NEW WALL TO ENCLOSE THE AREA UNDERNEATH ALL FIRST FLOOR STAIRCASES. CONSTRUCTION TO BE 3 9" METAL STUD WITH GYPSUM BOARD- HEIGHT TO BE 1' -0" AFF. SEE FIGURE 8 ON SHEET HCI.2 FOR ADA COMPLIANCE INFORMATION. 2 -14 GG GG RELAMINATE EXISTING FOLDING TABLE AS SPECIFIED. 2 -15 OW GC NEW OWNER SUPPLIED TABLE AND MIRROR MIRROR TO COVER ROOF ACCESS DOOR AND TORE HUNG ON THE WALL BUT NOT SEGUTED WITH SAFETY CLEAT FOR EASY ACCESS TO ROOF DOOR_ FLOORS: 3 -1 OW GC NEW CARPET AND PAD. (,NOTEI: NO NEW PAD AT EXCERGI5E ROOM' I*NOTE2: REMOVE AND REINSTALL ALL FFE OR MILLWORK PIECES AS REQUIRED.) 3 -2 GG GG NEW TRANSITIONS AT CARPET TO TILE INTERSECTIONS. 3 -3 OW GG NEW CARPET AT LANDINGS, RISERS AND TREADS. 3 -4 GG GG NEW STAIR NOSING INCLUDING CONTRASTING NOSING TO MEET CODE. 3 -5 GC GC NEW THRESHOLD. (,SEE FINISH INDEX FOR MORE INFORMATION.) 340 GC GC FURNISH AND INSTALL NEW TRANSITION PER PLAN AND SPECIFICATIONS. MISCELLANEOUS: 4 -1 OW GC NEW ARTWORK 4 -2 OW GC NEW FFE ITEMS. 4 -3 GC REINSTALL EXISTING EXERCISE EQUIPMENT AT EXERCISE ROOM. 4 -4 - GC REINSTALL EXISTING WASHER AND DRYER UNITS AT GUEST LAUNDRY. 4 -5 OW GG NEW FRAMED MIRROR 4 -6 OW GG INSTALL NEW FIRE EXTINGUISHER CABINET. Zimmerman Weintraub Associates, LLC Strategic Facilities Consulting and Architecture 410 SOUTH MICHIGAN AVE, SUITE 500 CHICAGO, ILLINOIS 60605 voice: 312. 879. 9636 fax: 312.554.9640 CCMH 06/16/06 ISSUE FOR PERMIT COURTYARD 05/16/2006 ISSUE FOR REVIEW 10290 N Meridian Street 04/00/2006 PRELIMINARY DESIGN No. Date Issue / Revision CCMH Courtyard I LLC COURTYARD BY MARRIOTT INDIANAPOLIS - CARMEL 10290 N Meridian Street INDIANAPOLIS, INDIANA Project No. 51BCC4002 Drawing File: FILENAME Drawn By HMB Checked By PH Stamp Signature: Date �_ z� o License /�A•I/� o/7 Signed: Expiration: Sheet Title: FIRST FLOOR KEY PLAN GUESTROOM CORRIDOR PLAN & FINISH INFORMATION Sheet: A1.1