HomeMy WebLinkAboutA1.2PG -500 —\ '� OF WALL U.N.O.
PG -202
32 0 1
205
ELEVATOR L055"'
ELEVATION
SCALE: 1/4" =
0 F(�D
cv
N
c _ A4.3
0- a
A
1
t���
ELEVATOR L055 ;*4
FLAN IDETAIL
PG -503
OF WALL UN-0-
ELEVATOIR L0 5�
ELEVATION
SCALE: 1/4" = I' -m"
1
EMM
' 1 PG -500
44.3
4
313
ELEVATOR L 055 #3
BEAN [DETAIL
SCALE: 1/4" = P -,a" �G% SCALE: 1/4" = 1' -O"
HEARING IMPAIRED
GUESTROOM
ADA COMPLIANT
GUESTROOM
CORRIDOR (TYPICAL)
5ECONID FLOOfR UESTfROOM COfRfRID0f;R f=LAN
SCALE: 1116" = 1' -0"
N
SHEET NOTE&
- DIMENSIONS ARE TO FACE OF FINISH UNO.
- ALL EXTERIOR CORNERS ARE TO RECEIVE CORNER GUARDS.
- CLEAN ALL ELECTRICAL DEVICES TO REMAIN. PROTECT DURING
CONSTRUCTION.
- REMOVE ALL CIRCULINE BULBS FROM REMOVED LIGHT FIXTURES.
CONTRACTOR TO LIQUIDATE OR DISPOSE OF OLD BULBS_
- WORK SHALL INCLUDE PROVIDING SEALANT AS PER
SPECIFICATIONS.
- FINISH FACE OF NEW WALLS TO ALIGN WITH EXISTING AS
REQUIRED.
- NEW WALL CONSTRUCTION TO BE (1) LAYER 8" GYPSUM BOARD
5
ON BOTH SIDES OF 25 GAUGE METAL STUDS (3- 8 "UNO) OR WOOD
STUDS IF ALLOWABLE PER CONSTRUCTION TYPE. USE MOISTURE
RESISTANT GYPSUM BOARD AT BATHROOM LOCATIONS.
- ARTWORK AND WALL MOUNTED LIGHT FIXTURES TO BE
COORDINATED WITH OWNER'S REPRESENTATIVE. DO NOT INSTALL
ITEMS WITHOUT ON -SITE COORDINATION WITH INTERIOR DESIGNER.
- PROVIDE BLOCKING FOR ALL AGGESSORIES.
- WHERE EXISTING TUB AND TILE SURROUND ARE TO REMAIN,
PROVIDE TUB PROTECTION USING PRE - FORMED DISPOSABLE
PVC TUB LINERS. TUB LINERS TO BE TAPED IN PLACE BEFORE
ANY DEMOLITION WORK IS STARTED.
- CONTRACTOR TO REMOVE AND STORE ALL GUESTROOM ITEMS
TO BE REUSED UPON COMPLETION OF RENOVATION. OWNER TO
SPECIFY ITEMS TO BE SAVED. CONTRACTOR TO PLACE AND
INSTALL ALL FURNITURE AND FIXTURES. FURNITURE AND FIXTURE
PLACEMENT SHALL BE APPROVED OWNER REP.
- EXISTING SPRINKLER HEADS, SMOKE DETECTORS, FIRE ALARM
HORN DEVICES AND PTAC UNITS TO REMAIN, UNLESS NOTED
OTHERWISE. PROTECT DURING CONSTRUCTION..
- AT ALL NEW AND RESTORATION TILE INSTALLATIONS, APPLY A
COAT OF SEALER TO TILE AND GROUT JOINTS.
- TAG NOTES IDX -XXX INDICATE THE MILLWORK FF4E
IDENTIFICATION CODE.
- FOR TYPICAL MOUNTING HEIGHTS, REFER TO SHEET HC -12.
FINISH CODES
205
CARPET BASE
313
PAINT
319
VINYL WALLCOVERING - ACCENT
320
VINYL WALLCOVERING
382
CORNER GUARD
REFER TO FINISH INDEX
FOR MORE INFORMATION
TYPICAL KE'Y'NOTES
DEMOLITION NOTES: x -x
CEILINGS:
1 -1 EXISTING FIRE PROTECTION DEVICES TO REMAIN. PROTECT DURING
CONSTRUCTION.
1 -2 EXISTING SPEAKER GRILLES TO REMAIN. PROTECT DURING
CONSTRUCTION.
1 -3 EXISTING SPRINKLER HEADS TO REMAIN. PROTECT DURING
CONSTRUCTION. GC TO VERIFY COMPLIANCE WITH CODES.
1 -4 EXISTING ACT AND GRID TO REMAIN. PROTECT DURING
CONSTRUCTION.
1 -5 EXISTING SMOKE DETECTORS, EXIT SIGNS AND GRILLES /VENTS TO
REMAIN. PROTECT DURING CONSTRUCTION.
I -6 EXISTING LIGHTING TO REMAIN, CLEAN LENS. PROTECT DURING
CONSTRUCTION.
1 -1 REMOVE EXISTING SURFACE MOUNTED LIGHTING AT ACT CEILINGS.
REROUTE ELECTRICAL TO ACCOMMODATE NEW LIGHTING.
1 -8 REMOVE EXISTING WINDOW TREATMENTS AND HARDWARE.
PATCH /PREP/REPAIR ALL AFFECTED AREAS.
1 -9 REMOVE EXISTING ACT AND GRID, PREP TO RECEIVE NEW. EXISTING
SUPPLY / RETURN GRILLES, LOVERS AND FIRE PROTECTION DEVICES
TO REMAIN IN CURRENT LOCATION.
WALLS:
2 -1 EXISTING FIRE ALARM PANEL, EMERGENCY EXIT SIGNS, EMERGENCY
LIGHT FIXTURES, FIRE PULL STATIONS, BATTERY PACKS, AND
THERMOSTATS TO REMAIN. PROTECT DURING CONSTRUCTION.
2 -2 REMOVE EXISTING COVER PLATES AT ELECTRICAL DEVICES. PREP TO
RECEIVE NEW TO MATCH COLOR OF EXISTING [DEVICE-
2-3 REMOVE EXISTING WALL FINISHES, INCLUDING BUT NOT LIMITED TO:
VINYL WALL COVERING, WALL BASE, 51GNAGE /GRAPHIC5, CORNER
GUARDS, ETC., AND ADHESIVES TO ORIGINAL SUBSTRATE. UNLESS
OTHERWISE NOTED. DO NOT ALLOW THE PAPER SURFACE OF THE
DRYWALL TO BE TORN. PATCH/PREP/REPAIR/SKIM COAT ALL
AFFECTED AREAS. ALLOW FOR Irmo NEW SKIM COAT IN GENERAL
AREAS.
2 -4 EXISTING WOOD BUMPER RAIL TO REMAIN. PROTECT DURING
CONSTRUCTION.
2 -5 EXISTING WALL MOUNT TV TO REMAIN. PROTECT DURING
CONSTRUCTION.
240 RELOCATE EXISTING HOUSE PHONE. TO BE 48" AFF.
PATCH/PREP/REPAIR ALL AFFECTED AREAS.
2 -1 EXISTING WALL MIRRORS TO REMAIN. PROTECT DURING
CONSTRUCTION.
2 -6 EXISTING PTAC UNIT TO REMAIN. PROTECT DURING CONSTRUCTION.
2 -9 EXISTING MOISTURE DAMAGE AT PTAC UNIT. USE ALL NEEDED MEANS
TO REMEDIATE PROBLEM.
2 -10 EXISTING WINDOW SILL FINISH TO REMAIN. PROTECT DURING
CONSTRUCTION.
2 -I1 REMOVE EXISTING GRAPHICS. PROTECT DURING CONSTRUCTION.
PATCH/PREP /REPAIR ALL AFFECTED AREAS.
2 -12 REMOVE ALL EXISTING SIGNAGE MOUNTED ON DOORS. (NOTE:
INCLUDING STAIR DESCRIPTION.) PATCH/PREP/REPAIR ALL AFFECTED
AREAS.
2 -13 REMOVE EXISTING SECURINTY EYE/BUTTON AT INTERIOR DOOR
FRAMES. PATCH /PREP /REPAIR ALL AFFECTED AREAS.
FLOORS:
3 -1 REMOVE EXISTING CARPET FLOOR FINISH INCLUDING ADHESIVES,
EXISTING WALL BASE AND PAD. (NOTE- WHERE APPLICABLE. RETAIN
EXISTING TAGK STRIPS AS POSSIBLE FOR REUSE.)
3 -2 EXISTING FLOOR FINISH AND WALL BASE TO REMAIN. PROTECT DURING
CONSTRUCTION.
3 -3 REMOVE EXISTING TRANSITION STRIP AT CARPET TO TILE LOCATIONS.
PREP TO RECEIVE NEW.
3 -4 REMOVE EXISTING CARPET AT LANDING, RISERS AND TREADS
INCLUDING RUBBER NOSING. PREP TO RECEIVE NEW.
3 -5 OMIT.
340 REMOVE EXISTING TRANSITION.
MISCELLANEOUS:
4 -1 EXISTING EXERCISE EQUIPMENT TO REMAIN. REMOVE /STORE AND
PROTECT FOR REINSTALLATION UPON COMPLETION OF OTHER WORK.
4 -2 EXISTING WASHER AND DRYER UNITS TO REMAIN. REMOVE /STORE AND
PROTECT FOR REINSTALLATION UPON COMPLETION OF OTHER WORK.
4 -3 REMOVE EXISTING FFE.
NEW CONSTRUCTION NOTES: X-X
Zimmerman Weintrauk
Associates, LLC
Strategic Facilities Consulting and Architecture
410 SOUTH MICHIGAN AVE, SUITE 500
CHICAGO, ILLINOIS 60605
voice : 312. 879. 9636
fax: 312.554.9640
CEILINGS:
ISSUE FOR PERMIT
1 -1 GG GC
CAULK JOINT AT ACT GRID AND VWC.
1 -2 GG GC
PATCH/PREP AND PAINT EXISTING GWB OR NON -ACT
04/00/2006
CEILING, BULKHEADS AND SOFFITS.
1 -3 GC GC
PAINT ALL EXISTING STEEL GRILLES AND DIFFUSERS AT
Issue / Revision
CEILING.
1 -4 OW OW
NEW WINDOW TREATMENTS AND HARDWARE.
1 -5 OW GO
NEW SURFACE MOUNTED LIGHT FIXTURE IN SAME LOCATION AS
PREVIOUS. PROVIDE ALL REQUIRED ELECTRICAL
CONNECTIONS.
1 -6 GC GC
NEW RECE55ED LIGHT FIXTURE(S), (1) EVENLY SPACED
RECESSED FIXTURE BETWEEN EVERY SURFACE MOUNTED
FIXTURE. GC TO VERIFY ELECTRICAL PANEL CAN
ACCOMODATE NEW LOAD. PROVIDE ALL REQUIRED
ELECTRICAL AND CONNECTIONS.
1 -1 GG GC
PROVIDE ALLOWANCE TO REPLACE 5510 OF EXISTING
DAMAGED ACT. ('NOTE: ALL NEW TILE TO BE LOCATED AT
ONE CONTIGUOUS AREA. GC TO SHUFFLE EXISTING TILES TO
MINIMIZE ANY OBVIOUS COLOR CHANGE BETWEEN TILES.)
1 -8 GC GC
CLEAN PRE/REPAIR AND PAINT EXISTING HVAG GRILLES,
ACCESS PANELS AND SPEAKERS.
1 -9 GG GC
NEW ACT TILES AND GRID
WALLS-
2-1 OW GG
NEW GRAPHICS PACKAGE. INSTALL TO CORRECT ADA
COMPLIANT HEIGHTS AT WALLS AND /OR DOORS.
2 -2 GC GG
NEW FULL HEIGHT CORNER GUARDS AT ALL EXPOSED
CORNERS.
2 -3 OW GC
NEW VINYL WALL COVERING.
2 -4 GC GC
NEW COVERPLATES AT ALL ELECTRICAL DEVICES INCLUDING
ALL SWITCHES, RECEPTACLES, CABLE AND PHONE DATA
JACKS. COLOR TO MATCH EXISTING DEVICE.
2 -5 GG GG
NEW SILENCERS AND SMOKE SEALS AT ALL DOORS.
2 -6 GG GC
PATCH /PREP AND PAINT EXISTING TEXTURED GWB WALLS.
2 -1 GC GG
PREP AND PAINT ALL HOLLOW METAL DOOR FRAMES AND
ALL OTHER HOLLOW METAL ITEMS (IE: ACCESS DOORS,
ELECTRICAL CABINETS AND FIRE EXTINGUISHER CABINETS,
ETC.). MASK AND PROTECT THE EXISTING DOOR HARDWARE
AND DOOR FINISH. PUTTY AND SAND TO PROVIDE LIKE -NEW
FINISH AT DOOR FRAMES.
2 -8 OW GC
NEW CARPET BASE AT CARPET FLOOR AREAS.
2 -9 GG GG
RELOCATE EXISTING HOUSE PHONE TO BE 48" AFF
PATCH/PREP/REPAIR ALL AFFECTED AREAS.
2 -10 GC GC
PREP AND PAINT ALL EXPOSED METAL SURFACES,
INCLUDING: STRINGERS, PICKETS, SPRINKLER PIPING AND
NON - ALUMINUM HARDWARE.
2 -11 GC GC
PREPARE WINDOW SILLS AND APPLY WOOD ENHANCER TO
RESTORE TO LIKE -NEW FINISH AS NEEDED.
2 -12 GG GG
OMIT.
2 -13 GC GG
BUILD NEW WALL TO ENCLOSE THE AREA UNDERNEATH ALL
FIRST FLOOR STAIRCASES. CONSTRUCTION TO BE 3 8" METAL
STUD WITH GYPSUM BOARD. HEIGHT TO BE 1' -0" AFF. SEE
FIGURE 8 ON SHEET HCl2 FOR ADA COMPLIANCE
INFORMATION.
2 -14 GC GG
RELAMINATE EXISTING FOLDING TABLE AS SPECIFIED,
2 -15 OW GG
NEW OWNER SUPPLIED TABLE AND MIRROR MIRROR TO
COVER ROOF ACCESS DOOR AND TORE HUNG ON THE WALL
BUT NOT SECUTED WITH SAFETY CLEAT FOR EASY ACCESS
TO ROOF DOOR.
FLOORS:
3 -1 OW GC
NEW CARPET AND PAD. ('NOTEI: NO NEW PAD AT
EXCERC15E ROOM+ "NOTE2: REMOVE AND REINSTALL ALL
FFE OR MILLWORK PIECES AS REQUIRED.)
3 -2 GC GC
NEW TRANSITIONS AT CARPET TO TILE INTERSECTIONS.
3 -3 OW GC
NEW CARPET AT LANDINGS, RISERS AND TREADS.
3 -4 GC GC
NEW STAIR NOSING INCLUDING CONTRASTING NOSING TO MEET
CODE.
3 -5 GC GC
NEW THRESHOLD. ('SEE FINISH INDEX FOR MORE
INFORMATION.)
3 -6 GC GC
FURNISH AND INSTALL NEW TRANSITION PER PLAN AND
SPECIFICATIONS.
MISCELLANEOUS:
4 -1 OW GC
NEW ARTWORK
4 -2 OW GG
NEW FFE ITEMS.
4 -3 - GG
REINSTALL EXISTING EXERG15E EQUIPMENT AT EXERCISE
ROOM.
4 -4 - GC
REINSTALL EXISTING WASHER AND DRYER UNITS AT GUEST
LAUNDRY.
4 -5 OW GC
NEW FRAMED MIRROR
4 -6 OW GC
INSTALL NEW FIRE EXTINGUISHER CABINET.
Zimmerman Weintrauk
Associates, LLC
Strategic Facilities Consulting and Architecture
410 SOUTH MICHIGAN AVE, SUITE 500
CHICAGO, ILLINOIS 60605
voice : 312. 879. 9636
fax: 312.554.9640
CCMH
06/16/06
ISSUE FOR PERMIT
COURTYARD
05/16/2006
ISSUE FOR REVIEW
10290 N Meridian Street
04/00/2006
PRELIMINARY DESIGN
No.
Date
Issue / Revision
CCMH
Courtyard I
LLC
COURTYARD
BY MARRIOTT
INDIANAPOLIS - CARMEL
10290 N Meridian Street
INDIANAPOLIS, INDIANA
Project No.
51BCC4002
Drawing File:
FILENAME
Drawn By
HMB
Checked By.
PH
Stamp
Signature:
Dote License
Signed: Expiration:
Sheet Title:
2ND FLOOR KEY PLAN
GUESTROOM CORRIDOR PLAN
&FINISH INFORMATION
Sheet:
A1.2