HomeMy WebLinkAboutM-2EXHAUST FAN HOUSING INSULATION PREFABRICATED CURB. PREFABRICATED CURB WITH BUILT -IN CANT. AND OFFSET FOR ROOF INSULATION THICKNESS FLASH CURB TO ROOF WITH MATCHING ROOF MATERIAL MIN. 12" OUT ON EA. SIDE ROOF —� c MIN 12" CURB PREFABRICATED CURB W \OUT ROOF INSULATION 1/4" ANCHOR BOLTS AND EXPANSION SHIELDS @ 12 "O.C. BACKDRAFT DAMPER DUCTWORK SEE PLANS FOR CONTINUATION. ROOF I?XITAUSTFAN DFTAn. NO SCALE RECTANGULAR TRUNK SUPPLY AIR DUCTWORK 45' RECTANGULAR TO ROUND VOLUMETRIC BALANCING DAMPER BRANCH TAP MANUAL ADJUSTMENT WITH POSITION ROUND BRANCH DUCTWORK LOCK SIZE PER FLOOR PLANS �� FLEXIBLE INSULATED DUCTWORK SAME SIZE AS BRANCH DUCTWORK AND SHEETMETAL ELBOW SQUARE CEILING DIFFUSER 5' -0" MAXIMUM LENGTH REFER TO FLOOR PLANS SHEETMETAL ELBOW SAME AND AIR OUTLET AND INLET SCHEDULE SIZE AS DIFFUSER NECK DUCT TAKE4 OFF DETAIL NO SCALE 824 WITH 1 ' INTERNAL LINER STRAP SUPPORT TO STRUCTURE THIS DETAIL REQUIRED AT ALL RG -1'S LAY -IN CEILING TYPICAL RETURN GRILLE SOUND ATTENUATOR NO SCALE 6 "0 MARK O.A., STUB INTO MFR. /MODEL VENTED ATTIC N0. SPACE, HARDWARE COIL CLOTH OVER REMARKS OPENING, CARRIER TYPICAL F -9,12 INTERLOCK W/ FURNACE MULTIPOISE FLEX. CONN. (TYP) SUCTION CONDENSING RA FURNACE SA NEOPRENE VIBRATION PAD TYPICAL ATTIC FURNACE SECTION NO SCALE TAMPER - RESISTANT THERMOSTAT COVER PLATE, AND CIRCUIT BREAKER - 2 4 1I �4 I ,/2 RECESSED HEATER WALL BOX ELECTRIC FORCED AIR MOUNTED UNIT HEATER NO SCALE AIR. HANDLING EQUIPMENT SCHEDULE MARK DESCRIPTION MFR. /MODEL REMARKS N0. EVAP. COIL COLOR REMARKS GAS FIRED FURNACE UNIT CARRIER FAN: 1,995 CFM @ 2.0" W.C. TOTAL STATIC PRESSURE, 200 CFM O.A. F -9,12 4 MULTIPOISE EVAPORATIVE COOLING COIL: 5.0 TONS @ 80/67'F DB /WB ENTERING AIR TEMPERATURE SUCTION CONDENSING CD -2 HEATING: GAS FIRED 100 MBH INPUT, 92 MBH OUTPUT, 90 +% AFUE UNIT AREA 4 ELECTRICAL: 1 PHASE, 120 VOLT BACK- C.F.M. SP. ACCESSORIES: 2" THROW AWAY FILTERS, GAS REGULATOR (IF REQ'D), CONCENTRIC VENT & TERMINATION KIT SA DIFFUSSER TMSA 226 -350 7 DAY PROGRAMMABLE THERMOSTAT WITH SUBBASE, 2424 SENS TOTAL FAN SHALL OPERATE CONTINUOUSLY DURING OCCUPIED CYCLE (AUTOMATIC) F- 4,5,11 GAS FIRED FURNACE UNIT CARRIER FAN: 1,600 CFM @ 2.0" W.C. TOTAL STATIC PRESSURE, 140 CFM O.A. VOLT 24x24 MULTIPOISE EVAPORATIVE COOLING COIL: 4.0 TONS @ 80/677 DB /WB ENTERING AIR TEMPERATURE DISCONNECT STARTER 0 HEATING: GAS FIRED 80 MBH INPUT, 74 MBH OUTPUT, 90 +% AFUE STARTER DISCONNECT M8H ELECTRICAL: 1 PHASE, 120 VOLT EDB'F EWB'F RG -1 ACCESSORIES: 2" THROW AWAY FILTERS, GAS REGULATOR (IF REQ'D), CONCENTRIC VENT & TERMINATION KIT DAMPER 0 -2000 W.C. 7 DAY PROGRAMMABLE THERMOSTAT WITH SUBBASE, POINT SWITCH CONTRACTOR FAN SHALL OPERATE CONTINUOUSLY DURING OCCUPIED CYCLE (AUTOMATIC) F- 2,3,6,8,10 GAS FIRED FURNACE UNIT CARRIER FAN: 1,200 CFM @ 2.0" W.C. TOTAL STATIC PRESSURE, 120 CFM O.A. 24x24 - MULTIPOISE EVAPORATIVE COOLING COIL: 3.0 TONS @ 80/677 DB /WB ENTERING AIR TEMPERATURE R -4 RA GRILLE 355RL HEATING: GAS FIRED 80 MBH INPUT, 74 MBH OUTPUT, 90 +% AFUE - CONNECTION - ELECTRICAL: 1 PHASE, 120 VOLT ACCU -1 -13 CARRIER ACCESSORIES: 2" THROW AWAY FILTERS, GAS REGULATOR (IF REQ'D), CONCENTRIC VENT & TERMINATION KIT MATCH EVAPORATIVE COIL GENERAL TOILET 957E 7 DAY PROGRAMMABLE THERMOSTAT WITH SUBBASE, 208/230 1 OR 30 FAN SHALL OPERATE CONTINUOUSLY DURING OCCUPIED CYCLE (AUTOMATIC) F -1,7 GAS FIRED FURNACE UNIT CARRIER FAN: 800 CFM @ 2.0" W.C. TOTAL STATIC PRESSURE, 120 CFM O.A. 5. FILTER DRIER. 9. SUPPORT FEET. MULTIPOISE EVAPORATIVE COOLING COIL: 2.0 TONS @ 80/67F DB /WB ENTERING AIR TEMPERATURE 10. WINTER START CONTROL. 3. NO USED. 7. LOW PRESSURE SWITCH. HEATING: GAS FIRED 80 MBH INPUT, 74 MBH OUTPUT, 90 +% AFUE 4. EVAPORATOR FREEZE THERMOSTAT. B. MOT❑RMASTER CONTROL, ELECTRICAL: 1 PHASE, 120 VOLT ACCESSORIES: 2" THROW AWAY FILTERS, GAS REGULATOR (IF REQ'D), CONCENTRIC VENT & TERMINATION KIT 7 DAY PROGRAMMABLE THERMOSTAT WITH SUBBASE, NOTES: 10 INSTALL FAN ON CURB PROVIDED BY FAN MANUFACTURER, PROVIDE FAN SHALL OPERATE CONTINUOUSLY DURING OCCUPIED CYCLE (AUTOMATIC) FCU -1 FAN COILE UNIT CARRIER FAN: 800 CFM @ 0.5" W.C. TOTAL STATIC PRESSURE, 0 CFM O.A. WITH WALL SWITCH. PROVIDE WITH TAPERED CURB. F SERIES EVAPORATIVE COOLING COIL: 2.0 TONS @ 80/67'F DB /WB ENTERING AIR TEMPERATURE ELECTRICAL: 1 PHASE, 120 VOLT ACCESSORIES: 2" THROW AWAY FILTERS, 7 DAY PROGRAMMABLE THERMOSTAT WITH SUBBASE, FAN SHALL OPERATE CONTINUOUSLY 7/24. AWH -A ARCH. WALL HEATER ERINCRAFT SEMI - RECESSED, 208 VOLT 1 PHASE, 1.5 KW, COLOR BY ARCH. AIR COOLED CONDENSING UNIT SCHEDULE MARK MFR MODEL COOLING CAPACITY EVAP. COIL COLOR REMARKS ELECTRICAL DATA SA DIFFUSSER ELECTRICAL CONNECTION REMARKS 4 MOTOR DATA 6 "0 SUCTION CONDENSING CD -2 SA DIFFUSSER UNIT AREA 4 MODEL NO. BACK- C.F.M. SP. CD -3 SA DIFFUSSER TMSA 226 -350 4 2424 SENS TOTAL A NO. TEMP AMB. AIR TEMP MCA VOLT 24x24 PHASE SINGLE DISCONNECT STARTER 0 FAN STARTER DISCONNECT M8H M8H EDB'F EWB'F RG -1 RA GRILLE DAMPER 0 -2000 W.C. 24x12 POINT SWITCH CONTRACTOR CONTROL BY BY POINT - 24x24 - WHITE R -4 RA GRILLE 355RL 0 -2000 - CONNECTION - WHITE ACCU -1 -13 CARRIER 38CK8 SERIE MATCH EVAPORATIVE COIL GENERAL TOILET 957E - 208/230 1 OR 30 YES BY E.C. BY E.C. REFER TO NOTES 1 -10 1. PROVIDE MOUNTING PAD. 5. FILTER DRIER. 9. SUPPORT FEET. 2. LOW AMBIENT LOCK OUT BELOW 49F, 10 SEER, CRANKCASE HEATER, CYCLE PROTECTOR. 6. HIGH PRESSURE SWITCH. 10. WINTER START CONTROL. 3. NO USED. 7. LOW PRESSURE SWITCH. 4. EVAPORATOR FREEZE THERMOSTAT. B. MOT❑RMASTER CONTROL, DIFFUSER GRILLES AND REGISTL.RS SCHEDULES MARK FUNCTION MFR TITUS FAN SCHEDULE DIRECTIONAL AIR FLOW SIZE NECK/ RUNOUT COLOR REMARKS CD -1 SA DIFFUSSER TMSA 51 -100 4 MOTOR DATA 6 "0 WHITE • CD -2 SA DIFFUSSER UNIT AREA 4 MODEL NO. BACK- C.F.M. SP. CD -3 SA DIFFUSSER TMSA 226 -350 4 2424 10 "0 WHITE A NO. SERVED TMSA 351-500 DRAFT 24x24 OF RPM HP VOLT 0 FAN STARTER DISCONNECT SINGLE NOTES WHITE M2 RG -1 RA GRILLE DAMPER 0 -2000 W.C. 24x12 - WHITE CONTROL BY BY POINT - 24x24 - WHITE R -4 RA GRILLE 355RL 0 -2000 - 2402 - WHITE E -1 CONNECTION 50R EF -1 GENERAL TOILET 12x12 GREENHECK G- SERIES YES 1400 3/4" 1140 3/4 115 1 24HR CONT. BY E.C. BY MFR YES 1O O2 EXHAUST NOTES: 10 INSTALL FAN ON CURB PROVIDED BY FAN MANUFACTURER, PROVIDE TAPERED CURB. O3 PROVIDE FAN BALL GAURD. 5O SELECT FOR .03" FD AT THROAT AREA. O GRAVITY BACK DRAFT DAMPER BY FAN MANUFACTURER. ® INTERLOCK WITH WALL SWITCH. PROVIDE WITH TAPERED CURB. DIFFUSER GRILLES AND REGISTL.RS SCHEDULES MARK FUNCTION MFR TITUS CFM RANGE DIRECTIONAL AIR FLOW SIZE NECK/ RUNOUT COLOR REMARKS CD -1 SA DIFFUSSER TMSA 51 -100 4 12x12 6 "0 WHITE • CD -2 SA DIFFUSSER TMSA 101-225 4 24x24 B "o WHITE O CD -3 SA DIFFUSSER TMSA 226 -350 4 2424 10 "0 WHITE A CD -4 SA DIFFUSSER TMSA 351-500 4 24x24 12 "0 WHITE A R -1 RA GRILLE 50R 0 -3000 - 6x24 - WHITE M2 RG -1 RA GRILLE 50R 0 -2000 - 24x12 - WHITE R -3 RA GRILLE 50R 0 -2000 - 24x24 - WHITE R -4 RA GRILLE 355RL 0 -2000 - 2402 - WHITE E -1 EXH GRILLE 50R 0 -400 - 12x12 - WHITE B. DAMPER c CJ o F" M :R U O;--I ohs U 00, ^� C C o w cl, o w� U Z w x t� U C) F Copyright 2002 All designs appearing herein shall not be duplicated, produced, or otherwise used without the written consent of DKO Architecture, PC. n 0 ^bo U o °�`° Yin � C) o �ccnnC7� �A • • • O O O O _ • A ���I11111111111///��� 9 twill nup te 920246 /till 111100 /c•*gLAo y /�.. Phase Date CD 04/18/05 A 0 0 0 Project No. Drawn by: 0410 MJ HAROLD M2