HomeMy WebLinkAboutS-2t i 1 2x6 CONTINUOUS 1x6 CONTINUOUS 2x6 0 2' -0" TJI A 4' -0" 7/16' APA RATED WALL SHEATHING 8d NAILS ®4' 16d NAILS 0 12" 4 RATED STURDI FLOOR 20 BETWEEN Td's ►'�; I OVA %I. 4 0 � U SECTION scale: 3/4 " =1' -0" S-21 TRUST ivr %,nvnv ADA DATIM M vu" ROOF NEL CUPS OVER BUILD TRUSS 16d NAIL DRIVEN INTO TRUSS BELOW ATHING `8� TYPICAL SECTION AT OVERBUILD S -2 3/4._l._o. DOUBLE UP JOISTS EACH SIDE OF OPENING 2X6 FLOOR OPENING FROM 14" TO 30" HEADER DEPTH TO MATCH JOISTS, SUPPORTED OFF DOUBLE JOISTS WITH JOIST HANGER INTERUPTED JOIST SUPPORTED FROM HEADER WITH JOIST HANGER 9 TYPICAL FLOOR OPENING 72J 3/4 " =1' -O" 20 0 1' -4" 2 -16d NAILS EACH TYPICAL NONLOAU BEARING 10 WALL CEILING CONNECTION SCALE: 3/4" =1' -0" S-2J NAILS AILS 12" ITiNUOUS 2- SEE PLAN 122' -8 1/2' FOR 3 dt 3M/ 110' -0' FOR 3A r H5 HURRICANE TiE AT EACH TRUSS 2 -26 TOP PLATE 2x6 0 2' 3A S-2 313 S -2 ROOF SHEATHING u 1/2' PLYWOOD 10d NAILS 0 4" AT EACH TRUSS 0 1 7/16" APA RATED WALL SHEATHING 3 TYPICAL ROOF TRUSS S-21 scale: 3/4 " =1' -0" 4 ROOF FRAMING scale: 3/4 " =1' -0' S-21 PLYWOOD SPACER AS REQUIRED "X" BRIDGING AT END OF JOIST AT BEAMS 5 SECTION S-2 J 3/4 " =1' -0" 16d NAILS 0 12 2x6 CONTINUOUS 1x6 CONTINUOUS 3/4- APA RATED STURDI FLOOR a WW 6 SECTION S-2 scale: 3/4 " =1' -0" 2 BY LUMBER TRIMMED TO MATCH STEEL BEAMS FLANGE WIDTH, WITH 1/2" DIAMETER BOLTS 0 24" STAGGERED FORMED JOIST HANGER - 2x6 0 2' -0" 7/16" APA RATED WALL SHEATHING Ti BLOCKING, ATTACH TO TOP PLATE WITH 10d NAILS 0 6' - TJ1 CONTiNOUS WITH 2' WIDE FLANGE MAX. IOD NAILS 0 6' -2 -2x6 CONTINUOUS - 2x6 0 1' -4" LEGEND LOAD BEARING WOOD WALL ON PLAN 1 �• r 4 •• ® SAWN LUMBER OR OPENING C`.....::'..,:`..�.' LIGHT WEIGHT CONCRETE OR GROUT INSULATION EXPANSION JOINT MATERIAL OR WOOD PANELING TOP OF DRILLED PIER OR TOP OF WOOD BEAM ABOVE NOMINAL FIRST FLOOR 14' -8" TOP OF SLAB OR BRICK LEDGE ELEVATION 2 INDICATES A REFERENCED PLAN NOTE INDICATES DIRECTION CUT 1 INDICATES SECTION NUMBER S3.1 INDICATES SHEET NUMBER WHERE SHOWN 3/4" BA 1 S7 INDICATES SHEAR WALL ZE LEVELING PLATE V 6000 PSI GROUT •3/4 "0 X 13" LONG CHOR BOLTS TYPICAL COLUMN BASE PLATE scale: 1- 1/2' =1' -0" GREGATE OR ILL CONCRETE iEDIUM DENSE SILTY SAND NOTE: PROVIDE CASING AND DEWATERING AS REQUIRED 'TYPICAL DRILLED PIER S-2 sc MASONRY NOTES: 1. ALL MASONRY SHALL HAVE 28 DAY COMPRESSIVE STRENGTHS EQUAL TO 1900 PSI. 2. ALL REINFORCING STEEL ( #3 BAR AND LARGER) SHALL BE ASTM A -615 GRADE 60. SPLICE LENGTH SHALL EQUAL 40 BAR DIAMETERS. ALL HORIZONTAL JOINT REINFORCEMENT SHALL BE COLD -DRAWN WIRE COMPLYING WITH ASTM A -82 AND GALVANIZED. 3. ALL MORTAR SHALL BE TYPE S. CHLORIDE ADMIXTURES WILL NOT BE PERMITTED. 4. ALL GROUT SHALL HAVE 28 DAY COMPRESSIVE STRENGTHS EQUAL TO 3000 PSI AND A SLUMP OF 9 INCHES. 5. ALL MASONRY BLOCK SHALL BE PLACED IN A RUNNING BOND PATTERN. 6. ALL VERTICAL REINFORCEMENT MALL BE IN GROUTED CELLS. ALL BOND BEAMS SHALL BE FILLED WITH GROUT. 7. ALL VERTICAL REINFORCEMENT SHALL BE IN CENTER OF GROUTED CELL AND HELD IN PLACE WITH WIRE POSITiONERS. PROVIDE CLEAN OUTS FOR GROUT POURS OVER 5 FEET HIGH, UNLESS NOTED OTHERWISE. 8. ALL HORIZONTAL REINFORCEMENT IN BOND BEAMS SHALL BE CONTINUOUS AT CORNERS. 9. PROVIDE #9 WIRE, TRUSS TYPE, HORIZONTAL JOINT REINFORCEMENT AT 16 INCHES VERTICALLY IN ALL MASONRY BLOCK WALLS. 10. PROVIDE 8" MINIMUM BEARING AT THE ENDS OF ALL LINTELS AND BEAMS SUPPORTED ON MASONRY. 11. PROVIDE GROUT IN MASONRY BLOCK BELOW ALL JOISTS, BEAMS AND LINTELS. GROUT TWO COURSES BELOW BEARING MEMBER VERTICALLY AND LENGTH OF BEARING MEMBER PLUS 1' -0" ON EACH SIDE HORIZONTALLY. 12. PROVIDE CONTROL JOINTS IN MASONRY AT 40' -0" MAX. UNLESS NOTED OTHERWISE. USE PREFORMED PVC CONTROL JOINT COMPOUND EQUAL TO D A2002 BY OUR -O -WALL IN MASONRY BLOCK. PROVIDE STANDARD SASHBLOCK TO ACCEPT CONTROL JOINT MATERIAL. 13. PROVIDE 1 -#5 VERTICAL IN FIRST CELL AT JAMBS, AT END OF WALLS, AND AT CORNERS. EXTEND REINFORCEMENT 3' -0" BEYOND HEAD AND SILL. 14, PROVIDE TEMPORARY BRACING UNTiL WALL IS INTEGRAL WITH STRUCTURE. 15. PROVIDE THE FOLLOWING LINTELS FOR ALL OPENINGS IN BRICK AND BLOCK UNLESS NOTED OTHERWISE: MASONRY BLOCK: GROUTED BOND BEAM WITH 2 - #5 BOTTOM FOR SPANS UP TO 4' -4" PRECAST CONCRETE: MULTIPLES OF 4" WIDE, 8" DEEP WITH 1 - #5 TOP AND BOTTOM FOR SPANS UP TO 4' -4 ". TEXTURE TO MATCH ADJACENT MASONRY AND SCORED. CONCRETE TO HAVE COMPRESSIVE STRENGTH OF 3000 PSi. SINGLE ANGLE PER 4" MASONRY UNIT: PAINTED STEEL USING THE FOLLOWING SCHEDULE: OPENING ANGLE TO 3' -4" L3x3x 5/16 3' -4" TO 5-8" L5x3x 5/16 ( LL VI 5' -8" TO 7' -0" L6x3 1/2 x 3/8 (LLV) WIDE FLANGE: W8x24 WITH 5/16" BOTTOM PLATE WELDED TO W8 AND PAINTED, FOR SPANS UP TO 10' -4 ". WIDTH OF BOTTOM PLATE TO EQUAL WALL THICKNESS MINUS 1 1/2-. STRUCTURAL STEEL NOTES: 1. ALL STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING: WIDE FLANGE SHAPES ASTM A572 GRADE 50 TUBES ASTM A500, (MADE B PLATES, CHANNELS AND REMAINING SHAPES ASTM A36 2. ALL STEEL SHALL BE DETAILED FABRICATED AND ERECTED IN ACCORDANCE WITH RISC ALLOWABLE STRESS DESIGN NINTH EDITION. 3. ALL BOLTED CONNECTIONS SHALL BE MADE WITH 3/4" A325 BOLTS. ALL BOLTED CONNECTIONS SHALL BE DESIGNED AS BEARING -TYPE WITH THREADS INCLUDED IN SHEAR PLANE. 4. ALL SHOP AND FIELD WELDS SHALL BE MADE WITH E70 ELECTRODES. 5. ALL STEEL SHALL BE PAINTED. 6. ANCHOR BOLTS SHALL BE A307. 7. GROUT SHALL BE SONOGROUT IOK BY SONNEBORN OR EQUAL. TYPICAL HEADER SCHEDULE COLUMN LOAD BEARING WALLS ANCHOR BOLTS WALL SIZE OPENING SIZE HEADER JAMB 6 "k 8" STUD LESS THAN 3' -9" TS8x8x 1/4 3 -2X6 OR 4 -2X6 2 -2X6 6 "dc 8" STUD 3' -9" TO 5' -0" 3 -2X8 OR 4 -2X8 2 -2X6 6 "& 8" STUD 5' -O" TO 8' -0" N -7; ( v 3 -2X12 OR 4 -2X12 3 -2X6 6 "dt 8" STUD 8' -0" TO 12' -0" 5.25X11.25 PARALLAM 4 -2X6 4' STUD 1' -4" TO 3' -8' 2 -2X8 2 -2X4 4" STUD 3' -8" TO 6' -0" U 2 -2X12 3 -274 4' STUD 6' -0" TO 10' -0" 3 1/2"01 1/4' PARALLAM 3 -20 NON -LOAD BEARING WALLS OPENING SIZE HEADER JAMB LESS THAN 3' -9" 2 -2X6 2 -2X4 3' -9" TO 8' -0" 2 -2X8 2 -2X4 8' -0" TO 12' -0" 2 -2X12 2 -2X4 NOTE: 1. PROVIDE 1/2' PLYWOOD SPACERS IN HEADERS WHERE REQUIRED. 2. FOR 2X8 WALL USE 5 1 /4 "X11 1/4- PARALLAM dt 2X12 BASE PLATE SCHEDULE COLUMN BASE PLATE ANCHOR BOLTS TS5x5x 3/16 3/4 "x13 "x1' -1" 4 -3/4" 0 x12" TS6x6x 1/4 3/4 . x14"x1'-2" 4 -3 4 0 x12" TS8x8x 1/4 3 4 "x16 "x1' -4" 4-3/4" 0_x12* GENERAL NOTES: 1. THE STRUCTURAL DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF STRUCTURAL DESIGN CONCEPT, THE DIMENSIONS OF THE BUILDING, AND MAJOR STRUCTURAL ELEMENTS. AS SCOPE DOCUMENTS, THE DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE IN DETAIL ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE STRUCTURAL REQUIREMENTS. BASED ON THE GENERAL SCOPE INDICATED AND DESCRIBED, THE CONTRACTORS SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE PROJECT. 2. WALSH ENGINEERING SERVICES, P.C. REVIEW OF SHOP DRAWINGS IS FOR CONFORMANCE WITH CONTRACT DOCUMENTS ONLY. WALSH ENGINEERING SERVICES, P.C. IS NOT RESPONSIBLE FOR QUANTITIES, DIMENSIONS, EXISTING CONDITIONS, ETC. 3. THE PURPOSE OF WALSH ENGINEERING SERVICES, P.C. SITE VISITATIONS IS TO BECOME FAMILIAR WITH THE PROGRESS, QUALITY OF CONSTRUCTION AND COMPLIANCE WITH THE CONTRACT DOCUMENTS. THE SITE VISITATIONS BY WALSH ENGINEERING SERVICES, P.C. DOES NOT INCLUDE INSPECTIONS OR CONSTRUCTION MANAGEMENT AND PROVIDES NO GUARANTEE OF THE WORK OR MATERIALS. 4. BUILDING CODES: INTERNATIONAL BUILDING CODE, 2000 WITH INDIANA AMENDMENTS AMERICAN INSTITUTE OF STEEL CONSTRUCTION, ASD 9TH EDITION AMERICAN CONCRETE INSTITUTE, 318 -89 5. DESIGN LOADS: ROOF DEAD LOAD 25 PSF FLOOR DEAD LOAD 50 PSF FLOOR LIVE LOAD 100 PSF CORRIDORS 50 PSF OFFICES + 20 PSF FOR PARTITIONS ROOF LIVE LOAD 20 PSF WIND LOAD BASK WIND SPEED =90 MPH, EXPOSURE B SEISMIC LOAD ZONE 1, OCCUPANCY 1V MECHANICAL UNITS CONSULT WITH MECHANICAL CONTRACTOR 6. SECTIONS INDICATED AS TYPICAL MAY NOT BE INDICATED ON PLAN MEETS. IT IS THE CONTRACTORS RESPONSIBILITY TO USE TYPICAL SECTIONS WHERE REQUIRED. 7. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING TEMPORARY BRACING AND /OR SHORING UNTIL THE PERMANENT BRACING IS IN PLACE. 8. ALL CONTRACTORS ARE REQUIRED TO COORDINATE THEIR WORK WITH ALL DISCIPLINES TO AVOID CONFLICTS. SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION REGARDING SIZE AND QUANTITY OF OPENINGS, SLAB REQUIREMENTS AND LINTELS. 9. IF A CONFLICT EXISTS BETWEEN CONTRACT DOCUMENTS, THE MORE STRINGENT CONDITION IS TO BE USED, UNLESS NOTED OTHERWISE. 10. VERIFY ALL EXISTING CONDITIONS PRIOR TO ANY CONSTRUCTION OR FABRICATION. IF CONDITIONS ARE DIFFERENT THAN SHOWN, NOTIFY ENGINEER /ARCHITECT IMMEDIATELY FOR MODIFICATIONS. FOUNDATION NOTES: 1. AN ASSUMED ALLOWABLE SOIL BEARING FORCE OF 31 KIPS, TO BE VERIFIED BY CONTRACTOR. 2. FOOTINGS ARE TO BE PLACED ON UNDISTURBED NATURAL SOIL (NOT PREVIOUS FILL MATERIAL) OR ENGINEERED FILL. 3. ENGINEERED FILL SHALL BE FREE OF ORGANIC MATERIAL, ROCKS LARGER THAN 2 INCHES, AND CLAY SHALL NOT HAVE A PI GREATER THAN 15. FILL SHALL BE COMPACTED TO A MAXIMUM DRY DENSITY OF 957. OF THE MODIFIED PROCTOR PER ASTM- 01557, AND PLACED IN 8 INCH LIFTS. 4. GRANULAR MATERIAL IS SOIL WITH A ROUNDED SHAPE, FREE OF ORGANIC AND CLAY MATERIAL WITH MAXIMUM SIZE AGGREGATE TO BE 3/8 ". 5. SEE SOIL REPORT FOR ADDITIONAL FILL REQUIREMENTS. 6. CONTRACTOR IS TO RETAIN A SOILS ENGINEER TO VERIFY BEARING CAPACITY 7, BRACE WALLS DURING PLACEMENT OF BACKFILL. WOOD NOTES: 1. ALL SAWN LUMBER, EXCEPT FOR NON -LOAD BEARING WALLS, SHALL BE NO. 2 SOUTHERN PINE WITH MC= 193'., WITH OUT CHECKS AND SPLITS. NON -LOAD BEARING WALLS CAN BE NO. 2 SPF. 2. ALL ENGINEERED LUMBER, (TJ AND PARALLAM), SHALL BE BY TRUS JOIST MACMILLAN OR EQUAL, AND INSTALLED PER THE MANUFACTURERS RECOMMENDATIONS. 3. ALL STEEL CONNECTORS IN CONTACT WITH PRESSURE TREATED LUMBER SHALL BE SIMPSON STRONG -TiE CONNECTORS (0185 GALVANIZED MINIMUM) OR EQUAL ALL STEEL CONNECTORS NOT IN CONTACT WITH PRESSURE TREATED LUMBER SHALL BE SIMPSON STRONG -TiE CONNECTORS (G90 GALVANIZED MINIMUM) OR EQUAL. 4. PROVIDE TEMPORARY BRACING UNTiL THE PERMANENT BRACING IS IN PLACE. 5. ALL CONNECTOR PLATES FOR WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH TRUSS PLATE INSTITUTE SPECIFICATIONS. 6. ALL ROOF AND WALL SHEATHING SHALL BE EXPOSURE 1, C -D STRU II APA RATED, WITH PANEL CUPS. 7. ALL SOLE PLATES SUPPORTED ON THE FOUNDATION WALL AND CONCRETE SLAB SHALL BE PRESSURE TREATED AS RECOMMENDED BY THE AMERICAN WOOD PRESERVERS INSTITUTE. 8. DESIGN OF WOOD TRUSSES AND THEIR CONNECTIONS SHALL BE PERFORMED BY A LICENSED ENGINEER IN THE STATE WHERE THE BUILDING IS TO BE BUILT. 9. ALL WOOD TRUSSES SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH THE TRUSS PLATE INSTITUTE, UNIFORM BUILDING CODE AND OSHA. 10. NAILS, SCREWS, AND LAG BOLTS ARE TO HAVE A MINIMUM YIELD STRENGTH AS SPECIFIED IN TABLES 12.3, 9.3, 8.2 AND 11.3 OF THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION. 11. ALL INTERIOR NON -LOAD BEARING STUDS SHALL BE 2X4 0 1' -40 . 12. ALL LOAD BEARING WALL CORNERS SHALL HAVE TRIPLE STUDS. 13. ALL NON -LOAD BEARING WALL CORNERS SHALL HAVE DOUBLE STUDS. 14. ALL SAWN LUMBER JOISTS SHALL HAVE SOLID BLOCKING OR CROSS BRIDGING AT 8' -0 ". 15. THE FOLLOWING NAILING SCHEDULE SHALL BE USED UNLESS NOTED OTHERWISE: CONNECTION NAILING BRIDGING TO JOIST OR TRUSS 2 -10d TOP PLATE TO STUD 2 -16d STUD TO SOLE PLATE 2 -16d END NAIL OR 4-8d TOE NAIL DOUBLE STUDS 10d AT 12" DOUBLED TOP PLATES 10d AT 8" BUILT UP COLUMNS 1 O AT 12" CONTINUOUS HEADER, TWO OR 10d AT i6" ALONG EACH EDGE MORE PIECES ROOF SHEATHING 10d AT 6" ALONG EDGES AND 12" ALONG INTERMEDIATE SUPPORTS FLOOR SHEATHING 8 GAGE SCREW AT 6" ALONG EDGES AND 12" ALONG INTERMEDIATE SUPPORTS WALL SHEATHING 8d AT 6" ALONG EDGES AND 12" ALONG INTERMEDIATE SUPPORTS GYP BOARD 6d AT 12 ALONG EDGES AND ALONG INTERMEDIATE SUPPORTS JOIST TO BEARING PLATE 2 -10d TOE NAILS, EACH SIDE 16. ALL PROTRUDING NAILS SHALL BE CLINCHED. 17. ALL FLOOR SHEATHING SHALL BE GLUED AND NAILED. 18. GLUE SHALL BE EM'S 5230 ELASTOMERIC ADHESIVE OR EQUAL. 19. ALL SHEAR WALLS SHALL BE BLOCKED. 20. IF PANELIZED WALL CONSTRUCTION IS USED, ALL WALL PANELS AND THEIR ATTACHMENT TO THE FOUNDATION SHALL BE DESIGNED BY A UCENSED ENGINEER IN THE STATE OF INDIANA. THE IWMATION OMTARED HEREIN IS THE EXCLUW PROPERTY OF WN_% ENGrWMG SERVICES, P.c., At0 IS THEREBY PROTECTED UNDER COPYMT LAK THE ORIN& WAS REPRMITEU HERERI BY THIS rfaR m" SHALL NOT BE un ALTERED aR RFPROmn N IVY mmM wTHOUT THE MESSED MtIT1EN CONSENT OF rALSH ENCMiTAe1G SERVICES. P.C. C\2 , cz FN I � cc pw co CO p 0 4 c k P w y W � � V CO C m I a� ct3 �. . G� 6 CO •'� C Cn y s � ( U �I J �w �z z U o „N U) o O �0Z ° L :3 wo g P� L N -7; ( v 3 O LMOn 0 <no ^ U �I J �w �z z OaQ z o0 zw- � °W 0 ry LO Q � U m Q N0. ' 8800913 _ ��• STATE (F �NDIANP •'���� SSION Phaw Date � �rT D 04/04/05 Project No. Drawn by: 05024 KHA NOTES AND DETAILS