HomeMy WebLinkAboutG-9Ln
J W
GENERAL INSTRUMENT SYMBOLS
� 4
N to
Ln FIELD MOUNTED INSTRUMENT
o
vi Co
v) Co INSTRUMENT MOUNTED ON
06 00 FACE OF PANEL
d 4
N,
N N INSTRUMENT MOUNTED BEHIND
OR INSIDE OF PANEL
INSTRUMENT MOUNTED ON
FACE OF LOCAL PANEL
CONTROL INTERLOCK FUNCTION, SEE
SCHEMATICS AND SYSTEM SPECIFICATIONS
FOR SPECIFIC FUNCTION
p
z
3
4
a.
m
r
Q
-j x
y
C! �
m
TAG NUMBERS AND ADDITIONAL DESIGNATIONS
FIRST LETTER
SUCCEEDING LETTERS
TR
3i- — NUMBER AFTER DASH ( -1, -2, ETC) DENOTES
MULTIPLE DEVICES USED IN IDENTICAL
DUPLICATE SYSTEMS.
A LETTER AFTER THE LOOP NUMBER (31A, 31B, ETC)
IS USED TO DISTINGUISH MULTIPLE SIMILAR DEVICES
IN THE SAME INSTRUMENT LOOP.
------LOOP DESIGNATION NUMBER
0 -0 -R -+ -- ADDITIONAL INSTRUMENT IDENTIFICATION
SEE FUNCTIONAL DESIGNATIONS
AND ABBREVIATIONS.
(9PCp
�� - -- -PANEL REFERENCE NUMBER AS FOLLOWS:
PCP = PURIFICATION CONTROL PALL
TSB = TRAVELING SCREEN BUBBLER .
TSC = TRAVELING; SCREEN CONTROL PANEL
RLB = RIVER LEVEL BUBBLER
FUNCTIONAL DESIGNATIONS AND ABBREVIATIONS
L--O -R = LOCAL - OFF - REMOTE
C -N -O = CLOSE - NEUTRAL -OPEN
r LINE SYMBOLS
MAJOR PROCESS PIPING OR FLOW CHANNEL
SECONDARY PROCESS PIPING
MISCELLANEOUS PIPING
P
ELECTRIC SIGNAL
HYDRAULIC SIGNAL
-fit - - -- N- PNEUMATIC SIGNAL
-- * - - - -+- ELECTRICAL DIRECTION ARROW
- - -i- - - -
SIGNAL CONNECTION POINT
i
r
}
TAG NUMBERS
MEANINGS OF IDENTIFICATION LETTERS
w
FIRST LETTER
SUCCEEDING LETTERS
w
MEASURED OR
READOUT OR
w
INITIATING
MODIFIER
PASSIVE
OUTPUT
MODIFIER
--J
VARIABLE
FUNCTION
FUNCTION
A
ANALYSIS
ALARM
BURNER,
USER'S CHOICE
USER'S CHOICE
USER'S CHOICE
g
COMBUSTION
_
T—
C
CONDUCTIVITY
CONTROL
(ELECTRICAL)
_
D
DENSITY (MASS)
DIFFERENTIAL
OR SPECIFIC
GRAVITY
E
VOLTAGE (EMF)
PRIMARY ELEMENT_________________
F
FLOW RATE
RATIO (FRACTION)
G
USER'S CHOICE
GLASS _
—
H
HAND (MANUALLY
�!
HIGH
INITIATED)
!�
__—
I
CURRENT
-- INDICATE
(ELECTRICAL)
J
POWER
SCAN
K
TIME OR TIME-
TIME RATE
CONTROL STATION
SCHEDULE
OF CHANGE
�A
L
LEVEL
LIGHT (PILOT)
—
_ LOW
M
MOISTURE OR
MOMENTARY
MIDDLE OR INTER -
HUMIDITY
MEDIATE
N
USER'S CHOICE
USER'S CHOICE
USER'S CHOICE
USER'S CHOICE
0
USER'S CHOICE
ORIFICE
(RESTRICTION)
P
PRESSURE OR
POINT (TEST
VACUUM
CONNECTION)
0
QUANTITY
INTEGRATE OR
INTEGRATE OR
TOTALIZE
TOTALIZE
_
R
RADIATION
RECORD OR
S
SPEED OR
SAFETY
SWITCH
FREQUENCY
T
TEMPERATURE
TRANSMIT_
U
MULTIVARIABLE
_
MULTIFUNCTION
MULTIFUNCTION
MULTIFUNCTION
V
VIBRATION
VALVE, DAMPER,
- -- WELL —��
OR LOUVER
— —
W
WEIGHT OR FORCE
X
UNCLASSIFIED
UNCLASSIFIED
UNCLASSIFIED _
UNCLASSIFIED _
Y
EVENT, STATE,
RELAY OR COMPUTE
OR PRESENCE
Z
POSITION.
DRIVE, ACTUATOR
DIMENSION
OR UNCLASSIFIED
FINAL CONTROL
ELEMENT
PROCESS DEVICE SYMBOLS
FLOW CONTROL OR ISOLATION GATE
VALVE: GLOBE, GATE, OR OTHER IN -LINE
TYPE NOT OTHERWISE IDENTIFIED
OPURGE OR FLUSHING DEVICE
NIA VALVE: THREE WAY
pul VALVE: FOUR WAY
TVS UMP
VS DENOTES: VARIABLE SPEED
PANEL LEGEND
.COMBINATION FILTER - REGULATOR WITH OUTPUT GAGE
DIFFERENTIAL REGULATOR WITH FLOW ROTOMETER
PRESSURE GAGE
PRESSURE SWITCH
DPS DIFFERENTIAL PRESSURE SWITCH
DIFFERENTIAL PRESSURE GAME
LT LEVEL TRANSMITTER
R INDICATION LIGHTS
8 PUSHBUTTON
POWER SUPPLY ABBREVIATIONS
WS '>-- WATER SUPPLY
AS } - POWER SUPPLY SOURCE LABEL.
USED ONLY WHERE NECESSARY
TO HELP CLARIFY AN INSTRUMENT
OR SYSTEM FUNCTION.
GENERAL NOTES
1. IN GENERAL, THE P AID SYMBOLS AND DEVICE IDENTIFICATIONS
ARE BASED ON INSTRUMENT SOCIETY OF AMERICA, STANDARD
PRACTICE ISA -SS.l (1988). SOME MODIFICATIONS. ADDITIONS,
AND ALTERATIONS HAVE BEEN MADE AS NEEDED TO ACCOMMODATE
THE PROJECT REQUIREMENTS.
2. ADDITIONAL CONTROL AND INTERLOCK REQUIREMENTS WHICH CAN
BE MORE CLEARLY ILLUSTRATED ON SCHEMATIC DRAWINGS HAVE
BEEN OMITTED FROM THE P & IO DRAWINGS. SOME PROCESS ITEMS,
SUCH AS EQUIPMENT ISOLATION VALVES, BYPASS LINES, ETC.,
WHICH ARE NOT CRITICAL FOR AN UNDERSTANDING OF THE
INSTRUMENTATION FUNCTIONS HAVE ALSO BEEN OMITTED.
3. THIS IS A GENERAL LEGEND SHEET. SOME SYMBOLS AND
ABBREVIATIONS MAY NOT BE UTILIZED ON THIS SPECIFIC PROJECT.
4. PIPING AND EQUIPMENT LEGEND APPLIES TOP A ID SHEETS
ONLY AND MAY DIFFER FROM LEGENDS FOR OTHER SHEETS.
THE FOLLOWING ADDITIONAL
DESIGNATIONS MAY BE UTILIZED
ADJACENT TO SOME VALVE OR
GATE SYMBOLS.
NC NORMALLY CLOSED
FC FAILS CLOSED
FO FAILS OPEN
FIP FAILS IN LAST POSITION
PROJECT NO.
B1ecIC a Nfamtm
Engineers — Architects
Kong City, W 114693.320
.a
a
LEGEND
CODE I DATE I BY
REVISIMS
DESCRIPTION
WS
Alt
Ao-
FF
F,
F,
AIR CYLINDER
ELECTRIC MOTOR
HYDRAULIC CYLINDER
DRAIN
4 —WAY SOLENOID VALVE,
TO VALVE OPERATOR
-v,,!,�! o ! ,�. INDIANAPOLIS WATER C O M P A N Y
coy..
gw' <# ; a1STf , WHITE RIVER NORTH WTP
. Qy
No-smi _ INTAKE
pa sT,�Tr`oM ELECTRICAL
`
%.�►R' P 8 ID LEGEND
''S ... '4 IzSEBNw BY EW40 BY CHECKED BY SHEET SHEET N
JS TOR HOF 31 Cf 33 G 9
coolpto BY A P P `R 0 Y E D B Y tlimwlNO IR8�6R
Mal
CCG. OWO. NO: 14GS3 -320- 205 -E006