Loading...
HomeMy WebLinkAboutJ-11Y Ln GENERAL INSTRUMENT SYMBOLS CO r N �t o (o FIELD MOUNTED INSTRUMENT N -+ o') m INSTRUMENT MOUNTED ON Co CO FACE OF PANEL 0 o INSTRUMENT MOUNTED BEHIND - - - OR INSIDE OF PANEL INSTRUMENT MOUNTED ON FACE OF LOCAL PANEL INSTRUMENT MOUNTED BEHIND - - - OR INSIDE OF LOCAL PANEL 1 SINGLE INSTRUMENT HOUSING CONTAINING TWO (OR MORE) INSTRUMENTATION FUNCTIONS CONTROL INTERLOCK FUNCTION, SEE O SCHEMATICS AND SYSTEM SPECIFICATIONS FOR SPECIFIC FUNCTION TAG NUMBERS AND ADDITIONAL DESIGNATIONS FIRST LETTER SUCCEEDING LETTERS TR 31- NUMBER AFTER DASH ( -1, -2, ETC) DENOTES MULTIPLE DEVICES USED IN IDENTICAL DUPLICATE SYSTEMS. A LETTER AFTER THE LOOP NUMBER (31A, 318, ETC) IS USED TO DISTINGUISH MULTIPLE SIMILAR DEVICES IN THE SAME INSTRUMENT LOOP. LOOP DESIGNATION NUMBER ADDITIONAL INSTRUMENT IDENTIFICATION SEE FUNCTIONAL DESIGNATIONS AND ABBREVIATIONS. z LINE SYMBOLS MAJOR PROCESS PIPING OR FLOW CHANNEL SECONDARY PROCESS PIPING MISCELLANEOUS PIPING EXISTING OR FUTURE PIPING AND EQUIPMENT -- - - - - -- ELECTRIC SIGNAL 3 ' HYDRAULIC SIGNAL -ff ff— PNEUMATIC SIGNAL SEX CAPILLARY TUBING ELECTROMAGNETIC OR SONIC SIGNAL (WITHOUT WIRING OR TUBING) - - - -- +- ELECTRICAL DIRECTION ARROW --- -i - - -- SIGNAL CONNECTION POINT I FLOW ARROW FOR PROCESS PIPING PROCESS OR SIGNAL LINE GOING TO ANOTHER SHEET �j PROCESS OR SIGNAL LINE FROM ANOTHER SHEET (MATCH LETTERS) 4 PROCESS LINES CROSSING (NOT CONNECTED) —0-0— ' INTERNAL SYSTEM SIGNAL LINK (SOFTWARE OR DATA LINK) J a. m Cr I O J � II M .�� C9 m u U LL B TAG NUMBERS MEANINGS OF IQENTIFICATION LETTERS Q� FIRST LETTER SUCCEEDING LETTERS w H HYDRAULIC I CURRENT P ~ MEASURED OR PULSE DURATION READOUT OR PULSE FREQUENCY R w INITIATING MODIFIER PASSIVE OUTPUT MODIFIER _j VARIABLE FUNCTION FUNCTION A ANALYSIS ALARM BURNER, USER'S CHOICE USER'S CHOICE USER'S CHOICE B COMBUSTION C CONDUCTIVITY CONTROL (ELECTRICAL) D DENSITY (MASS) DIFFERENTIAL OR SPECIFIC GRAVITY E VOLTAGE (EMF) PRIMARY ELEMENT F FLOW RATE RATIO (FRACTION) G USER'S CHOICE GLASS _ H HAND (MANUALLY HIGH INITIATED) - -- I CURRENT INDICATE - -- (ELECTRICAL) — - - -- ,^ J POWER SCAN K TIME OR TIME- CONTROL STATION SCHEDULE L LEVEL LIGHT (PILOT) _ LOW M MOISTURE OR MIDDLE OR INTER - HUMIDITY MEDIATE N USER'S CHOICE USER'S CHOICE USER'S CHOICE USER'S CHOICE 0 USER'S CHOICE ORIFICE (RESTRICTION) P PRESSURE OR POINT (TEST VACUUM CONNECTION) Q QUANTITY OR INTEGRATE OR INTEGRATE OR EVENT TOTALIZE TOTALIZE R RADIATION RECORD OR PRINT S SPEED OR SAFETY SWITCH FREQUENCY T TEMPERATURE _ TRANSMIT U MULTIVARIABLE MULTIFUNCTION _MULTIFUNCTION MULTIFUNCTION V VIBRATION VALVE, DAMPER, OR LOUVER W WEIGHT OR FORCE WELL X UNCLASSIFIED UNCLASSIFIED _ UNCLASSIFIED UNCLASSIFIED Y EVENT, STATE, RELAY OR COMPUTE OR PRESENCE Z POSITION, DRIVE, ACTUATOR DIMENSION OR UNCLASSIFIED FINAL CONTROL ELEMENT O Y r DIGITAL SYSTEMS INTERFACE SYMBOLS NOTE: REFER TO DETAILED SYSTEM SPECIFICATIONS FOR FUNCTIONAL DESCRIPTION. ALSO SEE I/O SCHEDULES FOR COMPLETE INPUT AND OUTPUT LISTINGS. COMPUTER SYSTEM FUNCTION BLOCK PROGRAMMABLE CONTROLLER SYSTEM FUNCTION BLOCK r— DIGITAL SYSTEM I/O INTERFACE DIRECTION OF ARROW DENOTES WHETHER INPUT OR OUTPUT. 0 LETTERS, TAG NUMBERS, ABBREVIATIONS AND COTHER ANNOTATIONS ARE SIMILAR TO THE GENERAL INSTRUMENT LEGEND. DASHED LINE THRU SYMBOL REPRESENTS FUNCTIONS WHICH 2 ARE NOT NORMALLY ACCESSIBLE TO THE OPERATOR. SOLID LINE REPRESENTS SHARED DISPLAY OR OPERATOR ACCESSIBLE FUNCTION. 2 SYSTEM REFERENCE NUMBER, AS FOLLOWS: I 1= 2= 3= 3A= 3B= 0 FUNCTION DESIGNATIONS AND ABBREVIATIONS K GAIN OR ATTENUATE (INPUT:OUTPUT) -K GAIN AND REVERSE I ADD OR SUM (ADD AND SUBTRACT) A SUBTRACT (DIFFERENCE) 1' EXTRACT SQUARE ROOT DIVIDE F W CHARACTERIZE SIGNAL HIGH - SELECT < LOW- SELECT X MULTIPLY f INTEGRATE (TIME INTEGRAL) C H4 METHANE C L2 CHLORINE RESIDUAL CO2 CARBON DIOXIDE DO DISSOLVED OXYGEN L EL LOWER EXPLOSIVE LIMIT MCC MOTOR CONTROL CENTER MLSS MIXED LIQUOR SUSPENDED SOLIDS 02 OXYGEN (PURITY) I PH CELL TURB TURBIDITY PROCESS DEVICE SYMBOLS DIAPHRAGM SEAL ® FLOW CONTROL GATE T UMP ANNULAR TYPE VS S DENOTES: VARIABLE SPEED DIAPHRAGM SEAL VALVE: GLOBE, GATE, OR OTHER IN -LINE TYPE NOT OTHERWISE IDENTIFIED PURGE OR FLUSHING DEVICE VALVE: EXISTING OR FUTURE PUMP (EXISTING OR FUTURE) REDUCER .::....... .........::::. VALVE: THREE WAY PRIMARY FLOW ELEMENT: ORIFICE PLATE SCREW (LIFT) PUMP VALVE: FOUR WRY PRIMARY FLOW ELEMENT: VENTURI TUBE VALVE: BUTTERFLY, DAMPER OR LOUVER �+ -/► COMPRESSOR OR BLOWER PRIMARY FLOW ELEMENT: FLUME PRIMARY FLOW ELEMENT: WEIR PRIMARY FLOW ELEMENT: TURBINE OR PROPELLER -TYPE PRIMARY FLOW ELEMENT: PITOT TUBE PRIMARY FLOW ELEMENT: ELECTROMAGNETIC OR TRANSIT -TIME ULTRASONIC DOPPLER TYPE ULTRASONIC FLOW SENSOR PRIMARY ELEMENT: ROTAMETER DRAIN a VALVE: ROTARY BALL TYPE N VALVE: CHECK id VALVE: PLUG TYPE THE FOLLOWING ADDITIONAL DESIGNATIONS MAY BE UTILIZED ADJACENT TO SOME VALVE OR GATE SYMBOLS. NC NORMALLY CLOSED FC FAILS CLOSED FO FAILS OPEN FIP FAILS IN LAST POSITION PROJECT NO. BIaCIC & v�tc 1 Engineers — Architects 14 69 3.310 Kansas City, Missouri MIXER PROPORTIONING OR METERING PUMP GENERAL NOTES 1. IN GENERAL, THE P &[0 SYMBOLS AND DEVICE IDENTIFICATIONS ARE BASED ON INSTRUMENT SOCIETY OF AMERICA, STANDARD PRACTICE ISA -SS.1 (1984). SOME MODIFICATIONS, ADDITIONS, AND ALTERATIONS HAVE BEEN MADE AS NEEDED TO ACCOMMODATE THE PROJECT REQUIREMENTS. 2. ADDITIONAL CONTROL AND INTERLOCK REQUIREMENTS WHICH CAN BE MORE CLEARLY ILLUSTRATED ON SCHEMATIC DRAWINGS HAVE BEEN OMITTED FROM THE P & ID DRAWINGS. SOME PROCESS ITEMS, SUCH AS EQUIPMENT ISOLATION VALVES, BYPASS LINES, ETC., WHICH ARE NOT CRITICAL FOR AN UNDERSTANDING OF THE INSTRUMENTAT[ON FUNCTIONS HAVE ALSO BEEN OMITTED. 3. THIS IS A GENERAL LEGEND SHEET. SOME SYMBOLS AND ABBREVIATIONS MAY NOT BE UTILIZED ON THIS SPECIFIC PROJECT. 4. PIPING AND EQUIPMENT LEGEND APPLIES TO P 8 ID SHEETS ONLY AND MAY DIFFER FROM LEGENDS FOR OTHER SHEETS. TRANSDUCER & CONVERTER DESIGNATION E VOLTAGE FSK FREQUENCY SHIFT KEYING H HYDRAULIC I CURRENT P PNEUMATIC PO PULSE DURATION PF PULSE FREQUENCY R RESISTANCE (ELECTRICAL) EXAMPLE: I/P = CURRENT TO PNEUMATIC TRANSDUCER POWER SUPPLY ABBREVIATIONS AS AIR SUPPLY ES ELECTRIC SUPPLY GS GAS SUPPLY HS HYDRAULIC SUPPLY NS NITROGEN SUPPLY SS STEAM SUPPLY WS WATER SUPPLY AS >-- POWER SUPPLY SOURCE LABEL. USED ONLY WHERE NECESSARY TO HELP CLARIFY AN INSTRUMENT OR SYSTEM FUNCTION. VALVE AND GATE ACTUATOR SYMBOLS DIAPHRAGM DIAPHRAGM WITH POSITIONER PRESSURE- REDUCING VALVE, SELF - CONTAINED PRESSURE - SUSTAINING VALVE, SELF - CONTAINED P AIR CYLINDER S SOLENOID P/0 AIR -OIL CYLINDER E ELECTRIC MOTOR H HYDRAULIC CYLINDER NO MANUALLY (HAND) OPERATED SYMBOL LEGEND REVISIONS PRELIMINARY ,,•,•• " " "<<• I N D I A N A P O L I S WATER C O M P A N Y CODE DATE BY DESCRIPTION APPR'4 AS BUILT BY APPR'D ST E �fO��' WHITE RIVER NORTH WTP �,9 A NOT FOR CONSTRUCTION 1 �� N 16655 = PUMPING STATION AND RESERVOIR Ac BID INDIANA: RESIDENT INSTRUMENTATION OF P 8 I D LEGEND 1'S N S CONSTRUCTION P •` PHYSICAL RECORD ,',,ll"'p, AL DESIGNED BY DRAWN BY CHECKED BY SHEET SHEET NUMBER JSM TOR HOF S6 OF 58 J 11 I AS BUILT CERTIFIED BY A P P R 0 V E 0 B Y DRAWING NUMBER flCC'T. NO. DATE COMPLETED •ZO i S, 'f•. rf r' t CCG. DWG. NO: 14693 -310- 247 -EO03