GENERAL INSTRUMENT SYMBOLS
CO r
N �t
o (o FIELD MOUNTED INSTRUMENT
N -+
o') m INSTRUMENT MOUNTED ON
Co CO FACE OF PANEL
0 o INSTRUMENT MOUNTED BEHIND
- - - OR INSIDE OF PANEL
INSTRUMENT MOUNTED ON
FACE OF LOCAL PANEL
INSTRUMENT MOUNTED BEHIND
- - - OR INSIDE OF LOCAL PANEL
1 SINGLE INSTRUMENT HOUSING CONTAINING
TWO (OR MORE) INSTRUMENTATION FUNCTIONS
CONTROL INTERLOCK FUNCTION, SEE
O SCHEMATICS AND SYSTEM SPECIFICATIONS
FOR SPECIFIC FUNCTION
TAG NUMBERS AND ADDITIONAL DESIGNATIONS
FIRST LETTER
SUCCEEDING LETTERS
TR
31- NUMBER AFTER DASH ( -1, -2, ETC) DENOTES
MULTIPLE DEVICES USED IN IDENTICAL
DUPLICATE SYSTEMS.
A LETTER AFTER THE LOOP NUMBER (31A, 318, ETC)
IS USED TO DISTINGUISH MULTIPLE SIMILAR DEVICES
IN THE SAME INSTRUMENT LOOP.
LOOP DESIGNATION NUMBER
ADDITIONAL INSTRUMENT IDENTIFICATION
SEE FUNCTIONAL DESIGNATIONS
AND ABBREVIATIONS.
z
LINE SYMBOLS
MAJOR PROCESS PIPING OR FLOW CHANNEL
SECONDARY PROCESS PIPING
MISCELLANEOUS PIPING
EXISTING OR FUTURE
PIPING AND EQUIPMENT
-- - - - - -- ELECTRIC SIGNAL
3
' HYDRAULIC SIGNAL
-ff ff— PNEUMATIC SIGNAL
SEX CAPILLARY TUBING
ELECTROMAGNETIC OR
SONIC SIGNAL
(WITHOUT WIRING OR TUBING)
- - - -- +-
ELECTRICAL DIRECTION ARROW
--- -i - - -- SIGNAL CONNECTION POINT
I
FLOW ARROW FOR PROCESS PIPING
PROCESS OR SIGNAL LINE GOING
TO ANOTHER SHEET
�j PROCESS OR SIGNAL LINE FROM
ANOTHER SHEET (MATCH LETTERS)
4
PROCESS LINES CROSSING (NOT CONNECTED)
—0-0— ' INTERNAL SYSTEM SIGNAL LINK
(SOFTWARE OR DATA LINK)
J
a.
m
Cr
I
O
J �
II M
.�� C9
m u
U LL
B
TAG NUMBERS
MEANINGS OF IQENTIFICATION LETTERS
Q�
FIRST LETTER
SUCCEEDING LETTERS
w
H
HYDRAULIC
I
CURRENT
P
~
MEASURED OR
PULSE DURATION
READOUT OR
PULSE FREQUENCY
R
w
INITIATING
MODIFIER
PASSIVE
OUTPUT
MODIFIER
_j
VARIABLE
FUNCTION
FUNCTION
A
ANALYSIS
ALARM
BURNER,
USER'S CHOICE
USER'S CHOICE
USER'S CHOICE
B
COMBUSTION
C
CONDUCTIVITY
CONTROL
(ELECTRICAL)
D
DENSITY (MASS)
DIFFERENTIAL
OR SPECIFIC
GRAVITY
E
VOLTAGE (EMF)
PRIMARY ELEMENT
F
FLOW RATE
RATIO (FRACTION)
G
USER'S CHOICE
GLASS
_
H
HAND (MANUALLY
HIGH
INITIATED)
- --
I
CURRENT
INDICATE
- --
(ELECTRICAL)
— - - --
,^
J
POWER
SCAN
K
TIME OR TIME-
CONTROL STATION
SCHEDULE
L
LEVEL
LIGHT (PILOT)
_
LOW
M
MOISTURE OR
MIDDLE OR INTER -
HUMIDITY
MEDIATE
N
USER'S CHOICE
USER'S CHOICE
USER'S CHOICE
USER'S CHOICE
0
USER'S CHOICE
ORIFICE
(RESTRICTION)
P
PRESSURE OR
POINT (TEST
VACUUM
CONNECTION)
Q
QUANTITY OR
INTEGRATE OR
INTEGRATE OR
EVENT
TOTALIZE
TOTALIZE
R
RADIATION
RECORD OR PRINT
S
SPEED OR
SAFETY
SWITCH
FREQUENCY
T
TEMPERATURE
_ TRANSMIT
U
MULTIVARIABLE
MULTIFUNCTION
_MULTIFUNCTION
MULTIFUNCTION
V
VIBRATION
VALVE, DAMPER,
OR LOUVER
W
WEIGHT OR FORCE
WELL
X
UNCLASSIFIED
UNCLASSIFIED
_ UNCLASSIFIED
UNCLASSIFIED
Y
EVENT, STATE,
RELAY OR COMPUTE
OR PRESENCE
Z
POSITION,
DRIVE, ACTUATOR
DIMENSION
OR UNCLASSIFIED
FINAL CONTROL
ELEMENT
O
Y
r
DIGITAL SYSTEMS
INTERFACE SYMBOLS
NOTE: REFER TO DETAILED SYSTEM SPECIFICATIONS FOR
FUNCTIONAL DESCRIPTION. ALSO SEE I/O SCHEDULES FOR
COMPLETE INPUT AND OUTPUT LISTINGS.
COMPUTER SYSTEM FUNCTION BLOCK
PROGRAMMABLE CONTROLLER SYSTEM
FUNCTION BLOCK
r— DIGITAL SYSTEM I/O INTERFACE
DIRECTION OF ARROW DENOTES
WHETHER INPUT OR OUTPUT.
0 LETTERS, TAG NUMBERS, ABBREVIATIONS AND
COTHER ANNOTATIONS ARE SIMILAR TO THE
GENERAL INSTRUMENT LEGEND. DASHED LINE
THRU SYMBOL REPRESENTS FUNCTIONS WHICH
2 ARE NOT NORMALLY ACCESSIBLE TO THE
OPERATOR. SOLID LINE REPRESENTS SHARED
DISPLAY OR OPERATOR ACCESSIBLE FUNCTION.
2
SYSTEM REFERENCE NUMBER, AS FOLLOWS:
I
1=
2=
3=
3A=
3B=
0
FUNCTION DESIGNATIONS AND ABBREVIATIONS
K GAIN OR ATTENUATE (INPUT:OUTPUT)
-K GAIN AND REVERSE
I ADD OR SUM (ADD AND SUBTRACT)
A SUBTRACT (DIFFERENCE)
1' EXTRACT SQUARE ROOT
DIVIDE
F W CHARACTERIZE SIGNAL
HIGH - SELECT
< LOW- SELECT
X MULTIPLY
f INTEGRATE (TIME INTEGRAL)
C H4 METHANE
C L2 CHLORINE RESIDUAL
CO2 CARBON DIOXIDE
DO DISSOLVED OXYGEN
L EL LOWER EXPLOSIVE LIMIT
MCC MOTOR CONTROL CENTER
MLSS MIXED LIQUOR SUSPENDED SOLIDS
02 OXYGEN (PURITY)
I
PH CELL
TURB TURBIDITY
PROCESS DEVICE SYMBOLS
DIAPHRAGM SEAL ® FLOW CONTROL GATE
T UMP
ANNULAR TYPE VS S DENOTES: VARIABLE SPEED
DIAPHRAGM SEAL VALVE: GLOBE, GATE, OR OTHER IN -LINE
TYPE NOT OTHERWISE IDENTIFIED
PURGE OR FLUSHING DEVICE
VALVE: EXISTING OR FUTURE
PUMP (EXISTING OR FUTURE)
REDUCER .::....... .........::::.
VALVE: THREE WAY
PRIMARY FLOW ELEMENT: ORIFICE PLATE SCREW (LIFT) PUMP
VALVE: FOUR WRY
PRIMARY FLOW ELEMENT: VENTURI TUBE
VALVE: BUTTERFLY, DAMPER OR LOUVER �+ -/► COMPRESSOR OR BLOWER
PRIMARY FLOW ELEMENT: FLUME
PRIMARY FLOW ELEMENT: WEIR
PRIMARY FLOW ELEMENT: TURBINE OR PROPELLER -TYPE
PRIMARY FLOW ELEMENT: PITOT TUBE
PRIMARY FLOW ELEMENT: ELECTROMAGNETIC
OR TRANSIT -TIME ULTRASONIC
DOPPLER TYPE ULTRASONIC
FLOW SENSOR
PRIMARY ELEMENT: ROTAMETER
DRAIN
a VALVE: ROTARY BALL TYPE
N VALVE: CHECK
id VALVE: PLUG TYPE
THE FOLLOWING ADDITIONAL
DESIGNATIONS MAY BE UTILIZED
ADJACENT TO SOME VALVE OR
GATE SYMBOLS.
NC NORMALLY CLOSED
FC FAILS CLOSED
FO FAILS OPEN
FIP FAILS IN LAST POSITION
PROJECT NO.
BIaCIC & v�tc 1
Engineers — Architects 14 69 3.310
Kansas City, Missouri
MIXER
PROPORTIONING OR
METERING PUMP
GENERAL NOTES
1. IN GENERAL, THE P &[0 SYMBOLS AND DEVICE IDENTIFICATIONS
ARE BASED ON INSTRUMENT SOCIETY OF AMERICA, STANDARD
PRACTICE ISA -SS.1 (1984). SOME MODIFICATIONS, ADDITIONS,
AND ALTERATIONS HAVE BEEN MADE AS NEEDED TO ACCOMMODATE
THE PROJECT REQUIREMENTS.
2. ADDITIONAL CONTROL AND INTERLOCK REQUIREMENTS WHICH CAN
BE MORE CLEARLY ILLUSTRATED ON SCHEMATIC DRAWINGS HAVE
BEEN OMITTED FROM THE P & ID DRAWINGS. SOME PROCESS ITEMS,
SUCH AS EQUIPMENT ISOLATION VALVES, BYPASS LINES, ETC.,
WHICH ARE NOT CRITICAL FOR AN UNDERSTANDING OF THE
INSTRUMENTAT[ON FUNCTIONS HAVE ALSO BEEN OMITTED.
3. THIS IS A GENERAL LEGEND SHEET. SOME SYMBOLS AND
ABBREVIATIONS MAY NOT BE UTILIZED ON THIS SPECIFIC PROJECT.
4. PIPING AND EQUIPMENT LEGEND APPLIES TO P 8 ID SHEETS
ONLY AND MAY DIFFER FROM LEGENDS FOR OTHER SHEETS.
TRANSDUCER & CONVERTER DESIGNATION
E
VOLTAGE
FSK
FREQUENCY SHIFT KEYING
H
HYDRAULIC
I
CURRENT
P
PNEUMATIC
PO
PULSE DURATION
PF
PULSE FREQUENCY
R
RESISTANCE (ELECTRICAL)
EXAMPLE: I/P = CURRENT TO PNEUMATIC
TRANSDUCER
POWER SUPPLY ABBREVIATIONS
AS
AIR SUPPLY
ES
ELECTRIC SUPPLY
GS
GAS SUPPLY
HS
HYDRAULIC SUPPLY
NS
NITROGEN SUPPLY
SS
STEAM SUPPLY
WS
WATER SUPPLY
AS >--
POWER SUPPLY SOURCE LABEL.
USED ONLY WHERE NECESSARY
TO HELP CLARIFY AN INSTRUMENT
OR SYSTEM FUNCTION.
VALVE AND GATE ACTUATOR SYMBOLS
DIAPHRAGM
DIAPHRAGM WITH POSITIONER
PRESSURE- REDUCING VALVE,
SELF - CONTAINED
PRESSURE - SUSTAINING VALVE,
SELF - CONTAINED
P AIR CYLINDER
S SOLENOID
P/0 AIR -OIL CYLINDER
E ELECTRIC MOTOR
H HYDRAULIC CYLINDER
NO MANUALLY (HAND) OPERATED
SYMBOL
LEGEND REVISIONS PRELIMINARY ,,•,•• " " "<<• I N D I A N A P O L I S WATER C O M P A N Y
CODE DATE BY DESCRIPTION APPR'4 AS BUILT BY APPR'D
ST E �fO��' WHITE RIVER NORTH WTP
�,9
A NOT FOR CONSTRUCTION 1 �� N
16655 = PUMPING STATION AND RESERVOIR
Ac BID INDIANA:
RESIDENT INSTRUMENTATION
OF P 8 I D LEGEND
1'S N S
CONSTRUCTION P •`
PHYSICAL RECORD ,',,ll"'p, AL DESIGNED BY DRAWN BY CHECKED BY SHEET SHEET NUMBER
JSM TOR HOF S6 OF 58 J 11
I
AS BUILT CERTIFIED BY A P P R 0 V E 0 B Y DRAWING NUMBER
flCC'T. NO. DATE COMPLETED •ZO i S,