CLAY TOWNSHIP
SANITARY SEWER SPECIFICATIONS
1. Standard specifications of the District and Indiana Department of Transportation shall apply
for all work and materials. Pipe shall be installed in accordance with Section 715.
2. Sanitary sewer pipe shall be PVC in accordance with ASTM D -3034 (S,D.R. 35) and ASTM
2321. PVC pipe shall have grooved bell and gasket. The pipe shall be made of PVC plastic
having a cell classification of 12454B.
3. PVC sewer fittings shall conform to the requirements of ASTM D- 3034 -89 specification.
Fittings in sizes through 8" shall be molded in one piece with elastomeric joints and
minimum socket depths as specified in sections 6.2 and 7.3.2. Fittings 10" and larger shall
be molded or fabricated in accordance with section 7.11 with manufacturers standard pipe
bells and gaskets. Wall thickness of fittings :3hail be SDR 26 as defined in section 7.4.1 of
specifications. Gaskets for elastomeric joints shall be molded with a minimum crasssectionai
area of 0.20 square inches and conform to ASTM F -477 specification. Fittings
shall be manufactured by Harco or equal.
4. All sanitary manholes shall be precast concrete manholes in accordance with ASTM C -478
and Section 720. 0 -rings shall conform to C -443. Kent Seal or equivalent shall also be
applied to all joints and between riser rings and castings. kt,anhole step spacing shall be no
more than 16- inches. Manholes shall be air tested for leakage in accordance with ASTM
C1244 -93, Standard Test Method for Concrete Sewer Manholes by the Negative Air
Pressure (Vacuum) Test.
A. Installation and operation of vacuum equipment and indicating devices must be in
accordance with manufacturers recommendations and performance specifications
which have been provided by the manufacturer and accepted by the Engineer. The
vacuum equipment must be capable of testing the entire manhole, including the
casting and riser rings.
B. With the vacuum tester set in place:
1. Connect the vacuum pump to the outlet port with the valve open.
2. Draw a vacuum of ten (10) inches of Hg. and close the valve.
C. Accepted standards for leakage will be established from the elapsed time for a
negative pressure change from ten (10) inches to nine (9) inches of mercury. The
maximum allowable leakage rate for a four (4) foot diameter manhole must be in
accordance with the following:
Minimum Elapsed Time for a
Manhole Depth Pressure Change of 1 Inch Hg
10 feet or less 60 seconds
>10 feet but <15 feet 75 seconds
>15 feet but <25 feet 90 seconds
For manholes five (5) feet in diameter, add an additional fifteen (15) seconds and for
manholes six (6) feet in diameter, add on additional thirty (30) seconds to the time
requirements for four (4) foot diameter manholes. For all manholes deeper than
twenty -five (25) feet, the Engineer will determine the applicable minimum elapsed
time.
D. If the manhole fails the test, necessary repairs must be made and the vacuum test and
repairs must be repeated until the manhole passes the test.
E. If manhole joint sealants are pulled out during the vacuum test, the manhole must be
disassembled and the joint sealants replaced.
F. Manholes will be subject to visual inspection with all visual leaks being repaired.
5. Butyl rubber coating shall be applied around each manhole joint from 6- inches above to 6-
inches below each joint. The appropriate primer shall be applied prior to applying the rubber
coating. Inside joints to be filled with precoat plug material.
6. The manhole chimneys, including all riser rings shall be sealed using infi- S":ield Uniband
or approved equal. Prior to placement, the top 4- inches of the manhole cone and casting
frame shall be cleaned and primed. The Uniband shall extend from 3- inches below the top
of the cone section to 2- inches over the flange of the manhole casting frame.
7, The casting elevations are set by plan. However, the castings are to be adjusted in the field
by the Engineers representative should a discrepancy occur between plan grade and existing
grade. New manhole ring and cover shall be installed to establish grade. Maximum height
of adjusting rings shall be 12- inches.
8. Backfill around all structures and all cuts under paved areas with granular material.
Trenches opening within 5 -feet of paved roadways shall be backfilled with granular material
in accordance with Section 211. Back-Fill under sidewalks shall be granular; unless the walks
are constructed a minimum of 6 months after backfill has been in place.
9. The Contractor shall be responsible for verifying that all state highways, city, and county
permits have been obtained by the developer prior to start of construction.
10. The Contractor shall be required to furnish the developer's Engineer with a set of prints,
marked in red pencil, showing actual sewer location and invert, to include lateral location,
depth and length. Such asbuilt prints must be received by t-ie Engineer before the final
contract payment can be authorized. The sanitary sewer laterals and stubs termination shall
be indicated on the surface with a metal fence post set immediately above the said
termination point.
CLAY TOWNSHIP REGIONAL WASTE DISTRICT
SUMMARY OF LATERAL INSTALLATION REQUIREMENTS
1. All houses, buildings, etc., shall connect to the District's sanitary sewer system
within 90 days of notice providing a sewer is within 300 feet for Hamilton County
or 100 feet for Boone County of the property line. Only one building may
connect to the sewer main per lateral unless otherwise approved by the District.
2. No foundation or other storm water drains shall be interconnected to the sewer
lateral installed and connected to the District's sanitary sewer.
3. The existing sewer line from the building to the septic tank may only be used if it
is located under a building addition, patio, porch, or paved driveway, Air test is
required to show if acceptable for re -use. The property owner shall bear the cost
of all testing. The District inspector must be onsite for the duration of the air test.
4. The owner or contractor shall notify the District prior to covering the installed
lateral so that the District can make an inspection to determine compliance with
the District's sewer use ordinance. Such notification shall be made 24 hours prior
to the need for the inspection. If the inspection fails and a second inspection is
required, or contractor is not an site for scheduled inspec tion, or fails to cancel
inspection, an additional fee of $75.00 will be due. This must be paid prior to the
time of the follow up inspection.
5. Property owners are herby advised that the County Board of Health regulates the
operation and maintenance of pri vote sewage disposal (septic) systems. The
County Ordinance provides in part that, upon connection to a public sewer, a
septic tank shall be abandoned and filled with earthen material in a safe and
sanitary manner. Please contact the appropriate Count y Board of Health for
further information.
6. Acceptable Pipe Materials:
PVC PIPE: SDR 35, ASTM D - 3034, SIX INCH PIPE
PVC PIPE: SDR 21, ASTM D - 241, SIX INCH PIPE
GASKETS JOINTS ASTM D - 3212
GASKETS ASTM F - 477
FITTINGS SDR - 26
DUCTILE IRON MECHANICAL COUPLING WITH PROPER FITTINGS
CLEAN OUTS TO BE LOCATED THREE FEET WITHIN THE
FOUNDATION AND NO MORE THAN 300 FEET APART.
7. Bedding:
Use fill sand or Number 8, 9, or 11 stone.
Fill material is to be placed from 6 inches below to 6 inches above the pipe.
The trench should be a minimum of 18 inches wide.
8. Laterals shall be installed no closer than 20 feet from water wells unless PVC
pressure grade pipe is used meeting SDR 21-and ASTM D 2241. Any proposed
installation requiring pressure pipe shall be reviewed and acce pted by the District
and the District's engineer prior to installation.
9. Where a transition is made between SDR 35 pipe and pressure grade SDR 21
pipe, a ductile iron gasketed mechanical coupling shall be used.
10. Laterals shall terminate within 3 feet of th a building :finless the conditions in
item #3 above are met. No glued pipe shall be installed outside of the building
foundation walls.
11. Additional information on District standards and specifications may be obtained
from the District's office during business hours of 8:00a.m. to 5:00p.m. Monday
through Friday. All District standards can be located on our web site at
http://www.ctrw.d.org
Clay Township Regional Waste District
10701 North College Suite A.
Indianapolis, IN 46280
Phone: 844 9200 Fax: 844 9203
12. Septic effluent shall not be pumped out into the sanitary sewer system.
13. The District shall inspect ALL laterals. Please call the District office at
844.9200 24 hours prior to time of inspection.
14. Contractors shall lay 14 gauge - stranded wire the entire length of the lateral..
Wire is to be placed on top of the lateral. The District inspector will verify
placement of the wire. After inspection, bedding is to be placed on top.
11. All sanitary sewer lines upon completion will be required to pass a low pressure air test.
Said test shall be conducted according to ASTM 1417 -92, and shall be witnessed by an
Engineer and a representative of the District. The testing shall be in accordance with Table
1. Add 0.5 psig for each foot of water above the sewer line being tested.
12. Deflection tests shall be performed on all flexible* pipe after the final backfill has been in
place at least 30 days. No pipe shall exceed a vertical deflection M i5eflection test
results. ( *The following are considered non - flexible pipes: concrete pipe, ductile iron pipe,
and cast iron pipe). The deflection test shall be perf ormed with anise -point mandrel.
Proving rings shall be available.
13. All mandrel testing shall be observed by a professional engineer representative for
certification and a representative of the District.
14. The ends of laterals are to be plugged tight with a braced plastic disc or cap capable of
withstanding a low pressure air test without leakage.
15. Bedding for flexible pipe shall be No. 8 crushed stone from 6- inches below the pipe to 12-
inches above the pipe. Bedding for rigid pipe shall be No. 8 crushed stone from 6- inches
below the pipe to the spring line of the pipe and from this point to 12- inches above shall be
-
fill sand or equivalent. Manholes shall be placed on no toss than 6 inche.. of No. 8 crushed
stone bedding.
16. Water and sewer line crossings and separations shall be in accordance with 327 LAC 3 -6 -9.
17. Trench shall be opened sufficiently ahead of pipe laying to reveal obstruction, and shall be
properly protected and /or barricaded when left uncttended.
18. No water shall be permitted to flow into the sanitary sewer system during construction.
Contractor shall utilize a pump to keep the water level below the pipe. Pump discharge shall
be directed to a storm outlet in accordance with state and federai laws and regulations (327
IAC 3- 6 -20). Any pipe entering existing sewers shall be plugged with screw type
mechanical, braced plug until such time as all tests or, the sewers have been completed and
the lines have passed all punch lists.
19. All sewer laterals installed by the mainline Contractor shall be bedded the some as the main
line sewer.
20. Forty -eight (48) hours notice shall be given to the District prior to the start of sewer
construction. Also, 48 hours notice shall be given prior to doing any testing on the sewer.
21. Manhole castings shall be stamped SANITARY SEWER (Neenah Casting R 1642A or
equal) and be self- sealing type. The casting flange shall be 34 inches and the clear opening
shall be 24 inches. Waterproof castings shall be Neenah R- 1916 -F1 and stamped
SANITARY SEWER.
22. The minimum slope for sewer acceptance by the Clay Township Regional Waste District are:
Size of Pipe Minimum Constructed Siope
3 -inch 0.40 %
10 -inch 0.28 %
12 -inch 0.22 %
15 -inch 0.15 %
18 -inch 0.12 %
23. The Contractor shall provide measurements of the slope of the sewer for each manhole
section as construction progresses. Such measurements shall be certified by a Registered
Land Surveyor or Engineer and be available on -site for observation by the District's
Inspector. No more than three manhole sections car be constructed in advance of such
measurements.
24. In the event the Contractor does not meet the minimum siooes, the sewer section and any
other affected sewer sections shall be reconstructed to meet such minimum slopes.
25. Laterals are to be traced with a minimum size of 14 gouge wire from the wye to the terminus.
The contractor for the building or home will extend the wire from this terminus to the
building cleanout adjacent to the building.
TABLE 1
MIINI%1UfA SPECIFIED TIME REQUIRED FOR.? I.Opsig
DROP FOR SIZE A \D LE`CrTH OF PIPE; INDIC.'CI'ED
FABLE I
Pipe I
Diameter
in.
n4inimmr
Time,
m in: s
Cengih fbr
Nfinimum
Time, fl
Time for
Longer
Length, S
Specification 'rime for Length a,) Shown, mints
_
6
66" & LARGER
6
100 ft
150 ft
300 ft
^SG
300 ft
350 J
4009
450 ft
4
3:4R
597
0.;60 L
3:46
3:46 1
3: 16
3 16 _
3: 16
3:16
3:46
3:46
6
5:40
386
0.851 L
5:40
5:40
5:40 1
5:40
5:40
5-40
5:42
6:24
8
7:34
298
1.5201.
31
':.34
7:34
7:3b
8:52
10:08
11:24
10
826
239
2.37.1 L
9:'S
9:28
?' S
9'63
1 L52
13:51
15:49
17 48
12
11:20
199
3.118 L
11 20
11:20
1.:21
14:1
17:05
19:58
fi
2"'47
25:38
16
14: 10
158
5342 L•
1 1 10
14:10
17: -18
1 22:15
26 :42
31:09
35:36
40:04
18
1700
1.3-1
7.682 L
17'00
19:13
25:33
32:03
26 27
44:52
51.16
57:41
21
19:50
114
10.470 L
18:60
26:10
3 -i: i -1
43.37
1 52:21
61:00
69:48
78:31
24
22:40
1 89
13.674 L
22-17
1 34:11
15-31
56:58
1 65:22
79:46
1 91:10
102:33
27
30
25:30
28:20
SR
80
17.306 L
2 i .3881.
28:51
96:37
43:16
53:25
5?: 11
"' i :13
?2:07
89::,2
96:32
1 OS:50
100:57
12 =1:38
115:22
1 142:25
129:48
160:15
33
31:10
72
25.552 L
-19 05
6435
SS 10
107:49
1 129:15
150:43
17221
193:53
38
34:00
86
30.788 L
61:17
76:55 102.12
L 12,
153:80
179:29
1 20 5: 07
230:16
I
0
l
oZ
0
WA TER MAIN --'
SEWER
10' MIN.
`\J
WATER MAIN"
SEWER_,
CLASS 150 MECH. JOINT
CAST IRON PIPE
10' .M, ".N.
IF LESS THAN 18- '
OR IF WATER MAIN
IS BELOW SEWER
� I �
IF LESS THAN 10,
VERTICAL SEPARATION
SHALL BE NO LESS
THAN 18".
I
W 1
3
I
I
Z
W
ti
WA TER
i MAIN
i \
:SY�
2
SANI TAR Y SEWER
CONC. J FLEXIBLE COUPLING
COLLAR ( TYP) OR ADAPTER ( TYP ,1
MIN CROSSO TIER & SEPARA TION REQUIREMENTS FOR
WA TER MAINS & SEWERS
NOT TO SCALE
CONCRETE COLLAR
BEDDING MATERIAL
HEAVY DUTY LAMPHOLE
CASTING W/ SOLID LID,
Y " NEENAH R -1974 OR EQUAL
BEND
!� 11 /4D
. i
CONCRETE CRADLE
CLEANOUT DETAIL
NOT TO SCALE
NOTE: CLASS "A" BEDDING TO BE UTILIZED FOR
ALL CLEANOUT INSTALLATIONS (SEE DETAIL)
D+8" MIN.
CAREFULLY
TAMPED <
BACKFILL 1714
;r� -� I an
1 4D =I ?T ='i I i- - Ti i i i ITT' i i _�
CONCRETE
CLASS "A" BEDDING
CONCRETE CRADLE
NOT TO SCALE
• CTRWD- °
EDGE OF PAVEMENT,
CURB, GUTTER OR
SIMILAR STRUCTURE
IN THE PUBLIC
RIGHT -OF -WAY
IF WITHIN 5' OF EDGE OF
PAVEMENT, USE #8 CRUSHED
STONE OR APPROVED EQUIV.
CLASS I BEDDING MATERIAL
HAND TAMPED OR WALKED INTO
PLACE TO MIN. OF 12" ABOVE
TOP OF PIPE, AND "B" BORROW
COMPACTED TO 95% STANDARD
PROCTOR DENSITY TO TOP OF
TRENCH.
LEGEND
Bc= OUTSIDE DIAMETER
D= INSIDE DIAMETER
d= DEPTH OF BEDDING
MATERIAL BELOW PIPE
MIN. 6" TOPSOIL
TO ENSURE GRASS
GROWTH IF NOT
UNDER PAVEMENT
M(NIMUNI WIDTH � � il�ll�l'
1:25 I3c.. -� 12' • II_ i
iii:
II III =-
I�I
1-
�MIN. 12"
IF NOT WITHIN 5' OF
EDGE OF PAVEMENT,
Bc USE #8 CRUSHED STONE
HAND TAMPED OR WALKED
INTO PLACE TO MIN.
F 12" ABOVE TOP OF
O
PIPE, AND REGULAR
d BACKFILL TO TOP OF
TRENCH.
N OTE:
ALL INITIAL BACKFILL SHALL
BE INSTALLED IN 6" TO 12"
BALANCED LIFTS.
A MINIMUM 9" OF CLEARANCE
SHALL BE PROVIDED ON EACH
SIDE OF THE INSTALLED PIPE.
DEPTH OF BEDDING MATERIAL BELOW PIPE
D
d (MIN)
27" & SMALLER
6
30" TO 60"
6
66" & LARGER
6
PLASTIC PIPE (PVC & HDPE) BEDDING DETAIL
NOT TO SCALE
5-0"
BEDDING MATERIAL COMPACTED
TO 95% BY PROCTOR
METHOD.
LONGITUDINAL SECTION
5' -0'
TRENCH SECTION UNDER PAVEMENT
NOT TO SCALE
NOTES:
1.) CONTRACTOR TO CONSULT SPECIFICATIONS FOR
COORDINATION OF MATERIALS TO BE USED.
Clay Township Regional Waste District
http : / /www.ctrwdsewers.org/ • 1317) 8AA -9200 • Fax j3 i 7j 844 -9203
August 2000
:a
CORE- AND
SEAL WITH °
BOOT
NOTE:
DROP PIPES SHALL BE
OPPOSITE FROM STEPS
WHEN POSSIBLE.
le OF #8 CRUSHED STONE -/ - - - - - � 1" STAINLESS STEEL STRAP
WITH 2) 1 4 "Ox 3 1/4. LG, EEL
STAINLESS ST EXPANSION
°I ANCHOR AT V MAXIMUM
SPACING (MINIMUM OF TWO
SANITARY SEWER )I •. STRAPS)
NATIVE UNDISTURBED SOIL -r `✓ . >
• PVC PIPE WITH 30'
FILL EXCAVATED SPACE )� �~ i BEND SHALL MATCH
OUTSIDE OF MANHOLE AND INCOMING PIPE
UNDER PIPE WITH #8 ° GROUT MANHOLE BOTTOM
CRUSHED STONE TO A �l ri TO PROVIDE SMOOTH FLOW
MINIMUM OF 6" ON EACH i CHANNEL TRANSITION
SIDE OF PIPE -;11
L
`.
G-
INSIDE DRQP DETAIL
NOT TO SCALE
f rr: f j Architects
:r
Consultants
Engineers
2 if
AMERICAN
"ONSULTING,
NC.
160 SHADELAND STATION
01ANAPOLIS, IN 46256.3917
175475580 317543.0270
,pyright (C) 2005 - Ammiccn Consulting, Inc.
PR BLOCK C, LLC.
8463 CASTLEWOOD
DRIVE
INDIANAPOLIS, INDIANA
MEDFORD PLACE
(LOT 3) AT WEST
CARMEL CENTER
CONSULTANTS
GG�� f ETgyq
mow` P�,OSTER fh
NO.
* 19900549
STALE OF
CERTIFIED BY
DATE- 03/3U05
DRAWN BY, PED
CHECKED BY- AF
ISSUED FOR- DATE-
ACE PROJECT IN2004.0948
TITLE
SANITARY SEWER
DETAILS /
SPECIFICATIONS
C6.2