HomeMy WebLinkAboutM-1P L U M B I N G F I X T U R E S C H E D U L E
ITEM
FIXTURE
WASTE
VENT
C. W.
H. W.
FIXTURE MOUNTING HEIGHT
P -1
Water Closet
3"
2"
1/2"
- - --
Floor Mounted
P -2
Cabinet Lavatory
1 -1/2"
1 -1/2"
1/2"
1/2"
Cabinet Mounted
P -3
Shower Enclosure
2"
1 -1/2"
- - --
- - --
Floor Mounted
P -4
Shower Head & Mixing Valve
- - --
- - --
1/2"
1/2"
6' -0" to Shower Arm
P -5
Bar Sink
1 -1/2"
1 -1/2"
1/2"
1/2"
Cabinet Mounted
P -6
Utility Sink
1 -1/2"
1 -1/2"
1/2"
1/2'
Floor Mounted
P -7
Whirlpool Tub
2"
1 -1/2"
112"
1/2"
Shelf Mounted
P -8
Cabinet Lavatory
1 -112"
1 -1/2"
1/2"
1/2"
Cabinet Mounted
P -9
Shower Head & Mixing Valve
- - --
- - --
1/2"
1/2"
6' -0" to Shower Arm
P -10
Cabinet Lavatory
1 -1/2"
1 -1/2"
1/2"
1/2"
Cabinet Mounted
P -11
Kitchen Sink
1 -1/2"
1 -1/2"
1/2"
1/2"
Cabinet Mounted
P -12
Laundry Sink
1 -1/2"
1 -1/2"
1/2"
1/2"
Cabinet Mounted
P -13
Tub /Shower
2"
1 -1/2"
- - --
- - --
Floor Mounted
P -14
Shower Head & Mixing Valve
- - --
- - --
1/2"
1 1/2"
6' -0" to Shower Arm
NOTES:
1.. All branch sizes shown in the above schedule are individual branch sizes to faucets, etc..
2. Water Closets shall be of tank type construction.
3. Cabinet sinks will be furnished complete with trim by the Mechanical Contractor at the job
site. The Mechanical Contractor shall set sinks and trim and shall provide all labor and
material to rough -in and hookup complete.
4. All fixtures shall have,a chrome - plated key operated valve exposed at the fixture.
F L 0 0 R D R A I N S C H E D U L E
TYPE
JAY R. SMITH
WADE
GENERAL LOCATION
SEE
NOTE
FLOOR DRAIN
TRAP
FLOOR DRAIN
TRAP
A
FD -31B
3" deep PVC
- - --
- - --
Finished Areas on Grade
1,2,3
B
FD -3213
3" deep PVC
- - --
- - --
Garage & Mech. Rooms on Grade
1,2,3
N_F.W.H.
DUCT SIZE ( WIDTH X DEPTH)
4 4 12"A Ioyl
SUPPLY DUCT SUCTION
NOTES:
1. All floor drains shall be full size of the connecting waste line shown on the drawings,
Unless otherwise noted.
2. All floor drains shall have nickel bronze rims and strainers with a PVC body. The strainers
shall have a 5" minimum diameter or twice that of the connecting waste line, unless other-
wise noted.
3. Floor drain shall have a shallow perforated sediment bucket and polished bronze strainer.
PLUMBING GENERAL NOTES:
1. The Plumbing Contractor shall provide a gas shut -off valve for each piece of fuel burning equipment.
2. All gas piping shall be schedule 40 black steel.
3. All hot and cold water piping shall be Type "L" hard copper with copper or wrought brass fittings.
4. All waste and vent piping shall be schedule 40 PVC.
5. All water piping below the floor slab shall be Type "K" soft copper.
6. Schedule of Plumbing Fixtures:
Item P -1, Water Closet: shall be Kohler (San Raphael #K-3397-EB) , vitreous china, one piece, siphon
jet elongated bowl, complete with K4653 seat with cover, brass hardware. Color: Innocent Blush.
Item P -2, Cabinet Lavatory: shall be Kohler (Caxton #K -2210) vitreous china under counter lavatory
complete with Grohe America "Exquisit "Combination Wide- Spread #20.610 -R faucet with pop -up drain
with polished brass finish, Chicago Faucet #1019 wheel handle stops with flexible tube risers and
cast brass "P" trap with cleanout. Color: Innocent Blush.
Item P -3, Shower Enlcosure: shall be provided by the ol:.hers. The Plumbing Contractor shall provide
a polished brass drain with 2" deep trap.
Item P -4, Shower Head & Mixing Valve: shall be Moen #73164 pressure balanced shower valve with
shower head.
Item P -5, Bar Sink: shall be Kohler (Aperitif #K -6562) self rimming enameled cast iron sink complete
with Kohler Antique Faucet (K -118) with high country spout in polished brass finish with #9637
white ceramic inserts, Chicago Faucet #1019 wheel handle stops with flexible tube risers and cast
brass "P" trap. Color: Innocent Blush.
Item P -6, Utility Sink: shall be Fiat Model FL1 single molded stone tub complete with Delta Faucet
Model #2121 laundry tub faucet, Chicago Faucet #1019 supply pipes with wheel handle stops and
flexible tube risers, cast brass "P" trap with cleanout.
Item P -7, Whirlpool Tub: shall be Kohler (Infinity Bath #1477) acrylic, fiberglass re- inforced tub
complete with #K -9683 polished brass trim kit. Moen Boutique #74932 Roman tub deck mounted tub
filler with polished brass finish,( #K -716) pop -up drain fitting with polished brass finish. Elec.
Data: 120 volt, 1 0, 60 hertz, 3/4 H.P.. Color: Innocent Blush.
Item P -8, Cabinet Lavatory: shall be Kohler (Caxton #K- 2210) vitreous china under counter lavatory
complete with Moen #74921 widespread combination faucet with pop -up waste assembly with polished
brass finish, Chicago Faucet #1019 wheel handle stops with flexible tube risers and cast brass "P"
trap with cleanout. Color: Innocent Blush.
Item P -9, Shower Bead & Mixing Valve: shall be Moen (Boutique #72917) polished brass dual handle
shower valve and shower head.
Item P -10, Cabinet Lavatory_ shall be supplied by the Owner. The Plumbing Contractor shall provide
Chicago Faucet #1019 wheel handle stops with flexible tube risers, cast brass "P" trap with cleanout
and all parts necessary for a complete installation.
Item P -11, Kitchen Sink: shall be Kohler (Bon Vivant #K -5911) enameled cast iron sink with self -
rimming edge. Supply complete with #K -5994 cutting board, wire rinse basket with utensil tray and
dish rack, #K -15172 single lever faucet with polished brass finish and hose with spray, #K- 9610PB
soap dispenser with polished brass finish, (2) #K -8801 polished brass duo - strainer, #K -9609 instant
hot water dispenser with polished brass finish, Chicago Faucet #1019 wheel handle stops with flexible
tube risers,.cast brass "P" trap, In- Sink- E:rator Model #17 garbage disposer and all parts necessary
for proper installation. Disposer Elec. Data: 120 volt, 1 0, 60 hertz, 1/2 H.P.. Instant Water
Dispensu-Elec. Data: 120 volt, 1 0, 60 hertz, 1.4 Amps. Sink Color: Innocent Blush.
Item P -12, Laundry Sink: shall be Kohler (Glenn Falls #K -6757) enameled cast iron sink complete
with Moen #7300 faucet, Chicago Faucet #1019 wheel handle stops with flexible tube risers and cast
brass "P" trap with cleanout. Color: White.
Item P -13, Tub /Shower: shall be Kohler (Mendota #K -506) enameled cast iron tub complete with #K -11666
drainage fitting with polished brass finish.
Item P -14, Shower Head & Mixing Valve: shall be Moen #73166 pressure balanced shower valve, tub
sport and shower head with polished brass finish.
Water Heater: shall be Lochinvar Model #KTN075, 75 gallon storage capacity, 72,000 BTUH input
natural gas, 63.1 GPH recovery at 100 °F rise. Supply complete with temperature and pressure relief
valve and all parts necessary for proper installation.
Recirculating Pump: shall be Bell & Gossett Series 100, 8 GPM at 6 ft, of total head. Elec. Data:
120 volt, 1 0, 60 hertz, 1/12 H.P.. Supply complete with all parts necessary for proper installation.
Washing Machine Fitting: shall be Guy Grey Model #BB -200 complete with 1/2" combination MPT brass
sweat connection.
Non - Freeze Wall Hydrant: shall be Woodford Model #25 complete with vacuum breaker backflow preventer,
loose key stop, 3/4" male hose thread, polished brass finish and all parts necessary for proper
installation.
Hose_ Bibbs: shall be Woodford Model 24 complete with vacuum breaker, 3/4" male hose thread, polished
brass finish and all parts necessary for proper installation.
Water Softener: shall be Bruner Model SBD -250, 25,000 grain maximum exchange capacity, 12 gpm service
flow capacity, 6 P.P.M. clean iron removal rate. Supply complete with all parts necessary for proper
installation.
H_V.A.C. GENERAL NOTI';; ;: (Apply to all sheets)
1. All ductwork shall be of sheetmetal construction with 1 -1/2" (1 lb. density) external fiberglass
insulation with vapor barrier.
2. Floor Supply Air Register: shall be Hart and Cooley Series 411 floor diffuser. Grille shall be of
all steel construction, opposed blade damper, and golden sand enamel finish.
3. Return Air Grilles: shall be Hart and Cooley Series 672 steel grille complete with dover white
finish.
4. Type "A" E.F. shall be Nutone Model 8673P combination exhaust fan /light, 100 CFM. Elec. Data: 120
volt, 1 $, 60 hertz. Lamp Watts: 100, 1.7 total AMPS.
5. Type "B" E.F.: shall be Nutone Model QT -110 exhaust fan, 110 CFM. Elec. Data: 120 volt, 1 0, 60
hertz, .85 AMPS.
6. Sidewall Supply Air Registers: shall be Hart and Cooley Series 661 steel supply register complete
with opposed blade damper and white enamel finish. H.V.A.C. Contractor shall verify the color with
the Architect prior to purchase.
7. Humidifier #1, #2, #3, #4 & #5: shall be Aprilaire Model 112. Elec. Data: 120 volt, 1 0, 60 hertz,
.75 AMPS. Supply complete with humidistat, 1/2" drain hose, saddle valve and all parts necessary
for proper installation.
8. G.F. #1: shall be Trane Model TUC120A960A, 1800 CFM @ .75" S.P.W.C., 120,000 BTUH input natural gas,
111,000 BTUH output. Elec. Data: 120 volt, 1 0, 60 hertz, 3/4 H.P.. Supply complete with Honeywell
#T -7300 thermostat, cooling coil, throw -away filter with side filter rack and all parts necessary for
proper installation.
9. Condensing Unit #1: shall be Trane Model TTJ060AI00A, 60,000 BTUH total cooling capacity. Elec.
Data: 240 volt, 1 0, 60 hertz, 40.0 M.C.A..
10. G.F. #2: shall be Trane Model TUC120A960A, 1300 CFM @ .75" S.P.W.C., 120,000 BTUH input natural gas,
111,000 BTUH output. Elec. Data: 120 volt, 1 0, 60 hertz, 3/4 H.P.. Supply complete with Honeywell
#T -7300 thermostat, cooling coil, throw -away filter with side filter rack and all parts necessary
for proper installation.
11. Condensing Unit #2: shall be Trane Model TTJ036A100A, 36,600 BTUH total cooling capacity, Elec.
Data: 240 volt, 1 0, 60 hertz, 24.0 M.C.A..
12. G.F. #3: shall be Trane Model TUC120A960A, 1800 CFM @ .75 S.P.W.C., 120,000 BTUH input natural gas,
111,000 BTUH output. Elec. Data: 120 volt, 1 0, 60 hertz, 3/4 H.P.. Supply complete with Honeywell
#T -7300 thermostat, cooling coil, throw -away filter with side filter rack and all parts necessary for
proper installation.
13. Condensing Unit #3: shall be Trane Model TTJ048A100A, 48,000 BTUH total cooling capacity. Elec.
Data: 240 volt, 1 0, 34.0 M.C.A..
14. G.F. #4: shall be Trane Model TUC120A960A, 1000CFM @ "75" S.P.W.C., 120 BTUH input natural gas,
111,000 BTUH output. Elec. Data: 120 volt, 1 0, 60 hertz, 3/4 H.P.. Supply complete with Honeywell
#T -7300 thermostat, cooling coil, throw -away filter with side filter rack and all parts necessary
for proper installation.
15. Condensing Unit #4: shall be Trane Model TTJ030A100A, 29,000 BTUH total cooling capacity. Elec.
Data: 240 volt, 1 0, 60 hertz, 24.0 M.C.A..
16. G.F. #5: shall be Trane Model TUC120A960A, 1200 CFM @ .75" S.P.W.C., 120,000 BTUH input natural gas,
111,000 BTUH output. Elec. Data: 120 volt, 1 0, 60 hertz, 3/4 H.P.. Supply complete with Honeywell
#T -7300 thermostat, cooling coil, throw -away filter with side filter rack and all parts necessary for
proper installation.
17. Condensing Unit #5: shall be Trane Model TTJ036A100A, 36,600 BTUH total cooling capacity. Elec.
Data: 240 volt, 1 0, 60 hertz, 24.0 M.C.A..
18. Pool Dehumidifying Unit: shall be Dumont "Zephyr" Model DP -800, 1975 CFM @ .5 S.P.W.C., 3.2 GPM,
19.2 LBS /HR. moisture removal rate with an 82 °F ambient, 80 °F pool water. Elec. Data: 240 volt,
1 0, 60 hertz, 42.5 M.C.A.. Blower = 1.0 H.P., Compressor = 3.5 H.P.. Supply complete with thermo-
stat, humidistat, and all controls and parts necessary for a complete installation.
19. Condensing Unit #6: shall be Bohn Model DVT006, 78,500 BTUH cooling capacity. I'lec. Data: 240 volt,
1 0, 60 hertz, 4.1 F.L.A..
20. Duct Furnace #1: shall be Trane Model GDNC -015, 150,000 BTUH input natural gas, 115,500 BTUH output.
Connect burner to pool dehumidifying unit as required.
21. Toe -Space Grilles: shall be Hart and Cooley Model_ 420 steel grille complete with prime coat finish
for field painting. Consult Architect for color. Painting by the H.V.A.C. Contractor.
..'. Pool Area Ceiling Supply Air Register: shall be Hart & Cooley Model A547 extruded aluminum double
deflection grille with anodized aluminum finish.
23. Pool Area Return Air Grilles: shall be Hart and Cooley Mode] A70 extruded aluminum grille with 42'
deflection van -s and anodized aluminum finish.
24. All pool dehumidifying piping shall be Type "K" hard copper from the pool loop to the unit by the
H.V.A.C. Contractor.
25. All 3 "0 combustion air intakes and flues from G.F. #1, #2, #3, #4, & #5 shall be schedule 40 PVC,
installed in strict accordance with the Manufacturer's Written Recommendations.
26. Electronic Air Cleaner #1, #2, #3, #4, & #5: shall be Electro -Air Model UST- 16C -26S -010, (Elec. Data:
120 volt, 1 0, 60 hertz. Provide complete with pre - filter and all parts necessary for proper
installation.
27. Type "C" E.F. (Pool): shall be Penn "Zephyr" Model Z -10, 365 CFM @ .25" S.P.W.C.. Elec. Data: 120
volt, 1 0, 60 hertz, 130 watts. Supply complete with #11FR sloped roof cap and all parts necessary
for proper installation.
28. U.H. #1: shall be Trane Model UHEC- 101BOA0, 34,100 BTUH, 700 CFM. Elec. Data: 240 volt, 1 0, 60
hertz, 42.2 Amps. Supply complete with wall bracket, thermlostat with summer- winter switch, and all
parts necessary for proper installation.
29. Type "A" Radiation: shall be Q -Mark Mod-1 = QMK -2_A6, 5118 BTUH. Elec. Data: 240 volt, 1 phase,
60 hertz, r3.z5 Amps. Supply completes wi integral thermostat, baked enamel finish, and all parts
necessary for propwr installation.
30. Prop. Fan #1: shall be Nutone Model 8070, 160 CFM. (Elec. Data: 120 volt, 1 0, 60 hertz, .8 Amps.
Supply complete with silver anodized aluminum inlet grille, discharge wall cap and all parts necessary
for proper installation.
31. All thermostat an(i rilmldistat w-1 r1 -:c b=_ supplied and installed by the H.V.A.C. Contractor.
IOZONE GENERATOR (FLUE UP THRU ROOF
SPA WATER HEATER
CHEMICAL- 21I w,45W
FEEzwjtI PIPIN(aN
CONTACTOR MIXER
FLOW MCTER`
-rf4 F- aMoMETER
DIATOMAGEOU5 EARTH FILTER
PRESSURE GAUGE
SALLVALVE(PRAIN f,
BACKWASH)
j I - i / 2 H. P. C.I RLULATING PUPW
/ (45 GPM 0 45 TDH ) V (Z) SPEED JET PUMP (90 GPM e 45 TDH )
SUMP
FLOOR DRAIN W/
TRAP 4 CLEAN OUT
1/2-
STRAINER VEIkIF:Y BPA MOuNTIM&
I" RETURN i I "AIRLINE ;TOSECON HF-I6,H-f • SEE BALL VALVES HYDRO -JET FITTING VFZAWINbl5 FOR Al»1TI0NA L,
ET PUMP C.ONTROJ I F
1 r-nrrrer)1
..W
I \ -N' 2" SUCTION
1/4" SUCTION '1g" W TO SANITARY SEWER
SPA EQUIPMENT PIPING DIAGRAM
NO SCALE
•- =r' HYDRO - .)ET
FITTING
i ; `• ; (TYP. OF 4)
�• -�• � ~,SPA
•- � SANDBACKFI�C.
} •� "•• � CONCRETE PAD
!� "ANTI VORTEX DRAAN
M E C H A N I C A L L E G E N D
NAME
SYMBOL
ABBREVIATION
GATE VALVE
so
CHECK VALVE
so
rIPING DROP WITH RESPECT TO FLOW
ow 1D,
PIPING RISE WITH RESPECT TO FLOW
low { —
PIPING TEE OUT TOP
_11W
TEE OUT BOTTOM
--fir—
NO FREEZE WALL HYDRANT
N.F.W.H.
N_F.W.H.
DUCT SIZE ( WIDTH X DEPTH)
4 4 12"A Ioyl
SUPPLY DUCT SUCTION
EXHAUST OR RETURN AIR DUCT SECTION
RETURAN AIR GRILLE
R.A.G.
SUPPLY AIR REGISTER
S.A_R.
PLUMBING CONTRACTOR
P.C_
MECHANICAL CONTRACTOR
M-C.
ELECTRICAL CONTRACTOR
E.C.
RAW COLD WATER
—Boo
RAW C.W.
SOFT COLD WATER
—►- --
SOFT C.W.
1100 HOT WATER
— lop
H.W.
SANITARY WASTE
W.
PLUMBING VENTS
FLOOR DRAIN
F. D.
F.D.
CLEANOUT
------- I---L �_c'
C.O.
WATER CLOSET
W.C.
LAVATORY
LAV_
MOP SINK
M.S.
GAS LINE
C,
G.
GAS FURNACE
G.F.
EXHAUST FAN
E.F.
THERMOSTAT
HU MIDI STAT
H
BALANCING COCK
31 a
CENTRAL VACL TM �`� �'�� B�_ ?4. C .
�y�V--tw—
VAC.
CON- TILACTOR
WATER PRESSURE
SWITCH
I" CC W rrk 2_" DEEP
-TRAP_M SUMP PUMP
THROTTLE VAL•VEN
P.C,� vASTAT
1 - l / 2" FROM
NIA IIJ DRAIN
lO PRESSURJ3 GAUGE
20 THERMOMETEtZ
OO FL_OW METER
AIM VENT (SY IPEHUMIDIFYIN&
UNIT SUPPLIER i INSTALLED
B y H VAe- CoNTFZAC.TOCZ)
1" R
TYPE "K" HARD C -OPPER
INJECTION NOZZLE
I- 1/2" eu PIP LY
POOL INLETS
CHLORINE
Plum F,
Pnnl P eo'JIIIPM9 Nrr PIPINel. (7;PIA6-,RAM
NOTE:
W IRE G.HLORINa I,UMF, To 2UN ONLY W 1-IEN GIQC_JI..A-[-I NCB
PUMP 15 RUNNINCw . . G 1 RG.ULATI NGs PUMP 5HA LL. tesE
1"1ANUAL_L_Y STARTED AND STOPPEF. PUMP- r�-F•IAaL-L RUN
ccNTINkOU°_LY TO =NSUR= PROPER oPERATIoN of DeHuMIDIFY1NbI
UN 1-r.