HomeMy WebLinkAboutA6TOP OF PRECAST
PANEL
0
i
0
FIN. FLR. --_ 00 \
TOP OF FTG. r
N
STEEL CHANNELS O 10'0" O.C.
50'
I
I
I
I
I
- - - - - - -
- - - - - - -
- - - - - - -
-- - - --
I
I
I
i
I
I
I
I
I
I
I
I
I
I
I
FOUNDATION
PLAN / MANA
ER'S UNIT
I
I
I
I
I
I
I
I
I
I
I
I
I
I
L- - - - - --
- - - - - --
- - - - - --
- - - - - --
I
I
I
I
I
-- - - - -J
50'
FOUNDATION
0
ro
P,LAN
SCALE: 1/8"=1'0"
/ TOP OF PRECAST PANEL
:D
METAL FASCADE cu
2' -6•
I
I ; I
I
L ------------------------------------------------
EAST ELEVATION
METAL FASCADE
OD
1
0
FIN. FLR.
TOP OF FTG.
N
r
6' -8„
6'
co
1 0
6" 13' -2"
A 13 p
BEDROOM 11 j
M
I I
1 II
L— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
IN-99
/2/, o /6' S•- DATE
NORTH ELEVATION
PAUL I. CRIPE, INC. ' CIVIL ENGINEERING
7172 GRAHAM ROA • LAND SURVEYING
INDIANAPOLIS, INDIANA 46250 • ARCHITECTURE
(317) 842 - 6777 • LAND PLANNING
REVISION
00
0
4
2
v mmin't-
C
E A 7
A 10
50'
6'
� O
i
4" 11' -3"
BEDROOM 10
I
91— 4 „ � 6 1
� O
NOTE:
TYP. EXT. WALL -5/8" DRYWALL ON 2"
MTL. STRIPS O 16" O.C., 2" STYROFOAM
INSUL. 6" MIL POLY VAPOR BARRIER
4" 12,8„
NOTE:
TYP. INT. WALL— SINGLE
1/2" DRYWALL ON 3 -5/8" ACTING
MTL. STUDS LIVING 06 DOOR
MTL. EDGE
0
2'-
4'
O
6, -8„
11
OFFICE
COUNTER
8, -0"
V6-
_I 00
r- I
F -3 00
A 7
I
SHELF & ROD N
12 F -4 AO (o
CLOSET 12
SHELF do ROD OFFICE 01
13 11 10 0
1 I SMOKE
,wJ to CLOSET 13 I DETEC.�HALL 5 -3/4" PLYWD. SHELVES O 16" O.C. PC6
4" X 4" COMPUTER
SHELF do ROD I 8' -6" I 4" MTL. EDGE CONTROL BOX
14 SUPPLIED BY E.C.
8 7 BROOM CLOSET
MTL. LINEN F -4 �
EDGE A 6" [ 20 GA. STL. STU S LINE OF CABINET P.T. D F.F. SOAP DISP.
W/ 6" TRACK TOP do 40" A.F.F.
BOT., R -19 BATT COMB. ME WH ° T. TISSUE HOLDER 4-
INSUL. do 5/8 DRYWALL CAB k ° I I
Ln
EA. SIDE do EXTEND UP TO MIRROR O I 0—F.D. F -5 — — — — ° — ° J N
ROOSTORAGE 09- ATH 08 UTILITY 07 DINING 05 A REF. iv F
6" 8' -4" 6" F -4 GRAB BARS 11/ "DIA.,11/ CLR. DIM. TO WALL -
6" KITCHEN 04 °p A Z 4 ANCHOR 33" ABOVE do PARALLEL TO
F -6 4• 5 „ " F.F. — PROVIDE WD. BLOCKING
A 7 85 6 99 4 -1 4 5 -6 6
D 2" LINE OF VALANCE ENTRY 03 T ILET 02
MTL. EDGE-1
F— 2
(D 5' ACCESS -- — - -- 5 r A 7
PANEL
(-nQ
9
FIBERGLASS TUB W/ 6 —0" O 00 F -2
B SURROUND k CHROME , O O HEA O O
7
1' -4„ 7, A ROD 6, -8" 4' 2' 6' 4' 3' PADP 6' A , -4„
A O
A 4" THICK CONIC PAD FINISHED WD. HA SHELF W/
50' SIZE AS REQ'D. 4" DIA. COAT HOOKS BELOW
CONC. FILLED PROTECTIVE POSTS (2)
NOTE: KITCHEN EXT. WALL ONLY 5/8" D
PLAN DRYWALL ON 4" MTL. STUDS 16" O.C. A 7
FLOOR do W/ R -13 BATT 6 MIL. POLY
VAPOR BARRIER
SCALE: 1/4"=1'0"
TOP OF PRECAST
PANEL
D.S.
CEIL. HGT.
of
FIN. FL.
TOP OF FTG. —�
I
N
CEIL. HGT.
I
i�
8" HIGH METAL FASCIA do GUTTER
NOTE:
ALL INTERIOR DIMENSIONS
ARE FACE OF STUD TO
FACE OF STUD.
WALL THICKNESSES ARE
NOMINAL. ACTUAL STUDS ARE 3 -5/8" OR
NOTE:
FOR INTERIOR ELEVATIONS
D.S. D.S. SEE SHEET A -11
4"
/ (rPrLPAj H BLOCK
I I
I I
L— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — J
r
SOUTH ELEVATION
MANAGER'S APARTMENT FLOOR/ FOUNDATION PLAN & ELEVATIONS
PROPOSED STORAGE FACILITY Pro1.N@.0325 DWG. TYPE FILE NUMBER SHEET
Dmw By
MICHIGAN ROAD scale JOB NUMBER A6
INDIANAPOLIS, INDIANA 8 5 ID00 14161-1110 [01010 OF
I � � ZD • 8S
Nvo, X GISTe", y4-
r p •�
No . 1624 I
sSTATE i
w cr 0
�N�Ttr- -
�,,
00 � Q
m11"ntllnn"00
MARBAUG
CERTIFIED BY
/2/, o /6' S•- DATE
NORTH ELEVATION
PAUL I. CRIPE, INC. ' CIVIL ENGINEERING
7172 GRAHAM ROA • LAND SURVEYING
INDIANAPOLIS, INDIANA 46250 • ARCHITECTURE
(317) 842 - 6777 • LAND PLANNING
REVISION
00
0
4
2
v mmin't-
C
E A 7
A 10
50'
6'
� O
i
4" 11' -3"
BEDROOM 10
I
91— 4 „ � 6 1
� O
NOTE:
TYP. EXT. WALL -5/8" DRYWALL ON 2"
MTL. STRIPS O 16" O.C., 2" STYROFOAM
INSUL. 6" MIL POLY VAPOR BARRIER
4" 12,8„
NOTE:
TYP. INT. WALL— SINGLE
1/2" DRYWALL ON 3 -5/8" ACTING
MTL. STUDS LIVING 06 DOOR
MTL. EDGE
0
2'-
4'
O
6, -8„
11
OFFICE
COUNTER
8, -0"
V6-
_I 00
r- I
F -3 00
A 7
I
SHELF & ROD N
12 F -4 AO (o
CLOSET 12
SHELF do ROD OFFICE 01
13 11 10 0
1 I SMOKE
,wJ to CLOSET 13 I DETEC.�HALL 5 -3/4" PLYWD. SHELVES O 16" O.C. PC6
4" X 4" COMPUTER
SHELF do ROD I 8' -6" I 4" MTL. EDGE CONTROL BOX
14 SUPPLIED BY E.C.
8 7 BROOM CLOSET
MTL. LINEN F -4 �
EDGE A 6" [ 20 GA. STL. STU S LINE OF CABINET P.T. D F.F. SOAP DISP.
W/ 6" TRACK TOP do 40" A.F.F.
BOT., R -19 BATT COMB. ME WH ° T. TISSUE HOLDER 4-
INSUL. do 5/8 DRYWALL CAB k ° I I
Ln
EA. SIDE do EXTEND UP TO MIRROR O I 0—F.D. F -5 — — — — ° — ° J N
ROOSTORAGE 09- ATH 08 UTILITY 07 DINING 05 A REF. iv F
6" 8' -4" 6" F -4 GRAB BARS 11/ "DIA.,11/ CLR. DIM. TO WALL -
6" KITCHEN 04 °p A Z 4 ANCHOR 33" ABOVE do PARALLEL TO
F -6 4• 5 „ " F.F. — PROVIDE WD. BLOCKING
A 7 85 6 99 4 -1 4 5 -6 6
D 2" LINE OF VALANCE ENTRY 03 T ILET 02
MTL. EDGE-1
F— 2
(D 5' ACCESS -- — - -- 5 r A 7
PANEL
(-nQ
9
FIBERGLASS TUB W/ 6 —0" O 00 F -2
B SURROUND k CHROME , O O HEA O O
7
1' -4„ 7, A ROD 6, -8" 4' 2' 6' 4' 3' PADP 6' A , -4„
A O
A 4" THICK CONIC PAD FINISHED WD. HA SHELF W/
50' SIZE AS REQ'D. 4" DIA. COAT HOOKS BELOW
CONC. FILLED PROTECTIVE POSTS (2)
NOTE: KITCHEN EXT. WALL ONLY 5/8" D
PLAN DRYWALL ON 4" MTL. STUDS 16" O.C. A 7
FLOOR do W/ R -13 BATT 6 MIL. POLY
VAPOR BARRIER
SCALE: 1/4"=1'0"
TOP OF PRECAST
PANEL
D.S.
CEIL. HGT.
of
FIN. FL.
TOP OF FTG. —�
I
N
CEIL. HGT.
I
i�
8" HIGH METAL FASCIA do GUTTER
NOTE:
ALL INTERIOR DIMENSIONS
ARE FACE OF STUD TO
FACE OF STUD.
WALL THICKNESSES ARE
NOMINAL. ACTUAL STUDS ARE 3 -5/8" OR
NOTE:
FOR INTERIOR ELEVATIONS
D.S. D.S. SEE SHEET A -11
4"
/ (rPrLPAj H BLOCK
I I
I I
L— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — J
r
SOUTH ELEVATION
MANAGER'S APARTMENT FLOOR/ FOUNDATION PLAN & ELEVATIONS
PROPOSED STORAGE FACILITY Pro1.N@.0325 DWG. TYPE FILE NUMBER SHEET
Dmw By
MICHIGAN ROAD scale JOB NUMBER A6
INDIANAPOLIS, INDIANA 8 5 ID00 14161-1110 [01010 OF
I � � ZD • 8S