HomeMy WebLinkAbout05050121-Site PlanBLOCK ~.
COMMONS
DU&sE
1
06 94
SF ----S
SILT FENCE
oc~
~0
'SILT
B ,NE
50' RAN (29'BO*BO)
WATER LiNE
PAGE 1 OF 2
INDIANA
(765) 345-5692
REVISIONS:
'o ~
SECTION 9005
INSTR ~200400055156
PC 3, SLIDE 459
LOT # 131
13314 BERWICK LANE
CARMEL, IN 46032
PLOT PLAN
pared For:
Notes per:
Brenwlck Development Company, Inc.
Yard light and mailbox to be installed per subdivision
covenants and restrictions.
Builder to contact Marie at Brenwick (574-3400) to
coordinate the house mailbox and yard light installation.
Please call 2 weeks prior to installation date.
574~400) to
light
Builder to clean mud from skeet at the end of each days
construction activity,
Builder to ensure mud does not enter creeks and is not
tracked onto streets.
Builder and Homeowner to assume all liabirk'y associated
with building floor elevations below the minimum flood
protection grade as depicted on the plans.
construction to assure locates are completed prior to
Builder to verify water tap location.
Area of water tap to be beck filled with granular mate~al
and restore ground to original condition.
Builder to insure 5 foot sideyard,
Builder to maintain 1 foot of separation f~om lot line to
edge of drive,
Note;
ZONING - PUD Ordinance Z-330
Large Lot -Secondary Area
Bulk Regulations
Minimum Front Yard * 20'
Minimum Side Yard - 5'
Minimum Side Yard Aggregate- 15'
Minimum Reer Yard-20'
This drawing is based upon construction plans and/or
record drawings prepmed by others and Is not based upon
a field surveY. COOR Consulting & Land Sewices, Coq~.
3ormc~ness or integ~ty of this
should verify existing
result in the
contractor/ownem
Contractor should verify site epclflc Information
deploed heron with the approved oonatruotion plan~ for
thle development
Nota:
The proposed construction grades depicted hereon are
based upon information, proposed grades and/er contours,
taken from the approved construction plans prepared for
this subdivision. Unless stated hereon, no information
perta nlng to but not imited to, fluctuating Water table
elevations, soil types or conditions within the building area
of said lot, has been provided or referenced on seld plans,
that the lowest floor elevation be constructed at least two
(2) feet above any adjoining bodies of water unless a study
of facts reveats othen~ise. Should any ground water be
witnessed during the excavation of seld ~. the
lowest floor elevation should be raised at least two (2) feet
above the ground water'level and'~dditional construction
techniques should be incorporated to alleviate future
problems.
PAGE 2
DATE: 09/27/04
· II
JOB ~004~60 REVISIONS:
VILLAGE OF
WEST CLAY
SECTION 9006-A
&
SECTION 9006-B