HomeMy WebLinkAbout05020015.8c In ID _n E 0 0 N N (D 0 z CIO 3 0 J IL uo N O_ 3 E a LO N O r ID 2 JD J Q M ST[ J` 0 d EXIST 4" EXIST 4" I PARTIAL FOUNDATION PLUMBING PLAN SCALE: 11/8"-V-0" EXIST 1 -1 /2" I� 1 -1/2 I V EXIST 1-1/2" q 1 -- EXIST 4" EXIST 4" �� 1 -1/2" I SK -1 2'• 2" SANITARY RISER DIAGRAM NO SCALE EXIST 1" EXIST 1-1/2" EXIST 3/4 SK -4a_L J 1 -1 2 112" /P l EXIST 1" � 77 3/4' EXIST 3/46 14 Q 13 15 1 EXIST 1 -1 /2" PARTIAL FIRST FLOOR PLUMBING PLAN SCALE: 1/8 " =1' -0" COUNTER TOP STERIS PROCESSOR DETAIL DROP IN WALL RISE IN WALL ?E VACUUM BREAKER " HW TO 3/4" HW PIPE CD Q 7 — EXIST 3/ a Y7 EX 71/7 �� 77��7 1' 1 1 [XIS' 3/4" �� 1 CD 1 1 1 z 8 C D 1 � Q / nI n jvL 1. 3 i ' /4" ,� -MV—c� 1 7 B 3/4„ 1 /2„ PARTIAL FIRST FLOOR MEDICAL GAS PLAN `,CALL: 1 /8" =1' -0° MEDICAL GAS OUTLETS SCHEDULE SYMBOL DESCRIPTION OUTLETS REMARKS 0 ZONE VALVES �7A 3/4° 1 - 11 CEILING GAS TRACK 1 -WAGD, 2 -0, 2 -MV, 1 -MA, 1 -NO, 2 -S - © CEILING BOOM 1 -WAGD, 2 -0, 2 -MV, 1 -MA, 1 -N0, 2 -S - 200 WALL OUTLET 1 -MV, 1 -S - NITROGEN CONTROL CABINET 1 -N - WATER HAMMER ARRESTOR SCHEDULE MARK I.P.S. F.U. RATING J.R. SMITH JOSAM ZURN �7A 3/4° 1 - 11 5005 75001 100 © 1" 12 - 32 5010 75002 200 PLAN NOTES 2" W DN - 1-1/2" V RISE - 3/4" H & CW DROP J 2" W UP 0 FIXTURE NOT TO BE INSTALLED. ROUGH -IN PIPING TO BE NSTAILED AND CAPPED. 0 3/4" WAGD, 1" MV, 3/4" 0, 3/4" MA, 1/2" NO, 1 DROrI TO AREA SHUT -OFF VALVES 3/4" WAGD, 1" MV, 3/4" 0, 3/4" MA, !III" NO, 112" N RISEf' �6 3/4" WAGD, 1" MV, 3/4" 0, 3/4" MA, 1/2" NO, 112" N CAPPED FOR FUTURE CONNECTION �7 3/4" WAGD, 1° MV, 3/4" 0, 3/4" MA, 1/2" NO DROP TO GAS TRACKS �8 3/4" WAGD, f MV, 3/4" 0, 3/4" MA, 112" NO DROP TO BOOM 90 1/2" N DROP TO NITROGEN CONTROL CABINET 10 3/4" MV DROP TO WALL OUTLET 2" SCH 40 DWV PVC PIPE 2 2" W UP TO SERVE STERIS MACHINE 13 REMOVE SECTION OF 3/4" HW LOOF AND REROUTE AS INDICATED 14 3/4" HW DROP, RISE CONNECT 1/2" HW LINE TO LOOP AS 36" A.F.F. TO SERVE STERIS MACHINE 5 2" W DN REFER TO STERIS DETIAL 16 1" CW DROP TO STERILIZER; PROVIDE 3 /4 "WILKINS MODEL 975 RPZ n17i REMOVE EXISTING FLOOR DRAIN AND INSTALL SMITH MODES 24111 FLOOR SINK 018 MODIFY EXISTING FIRE PROTECTION PIPING SYSTEM AS REOUIRE_1) TO ACCOMODATE THE NEW FLOOR, CEILING AND EQUIPMENT SERVING THIS AREA. t � 9365 Counselors Row Indianapolis, IN 46240 -1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com ST. VINCENT CARMEL HOSPITAL 13500 N. Meridian Street P.O. Box 1903 Carmel, Indiana 46032 OR 11 BU I LDOUT MARK DATE DESCRIPTION • 7N M.S,q� �. 18108 = �;• STATE OF S/G N A E F A$ C/2. /—..I SURGERY PLUMBING PLANS SCALE 1/81, 1 ' -0" CLIENT NO, DATE 24 NOV 2004 COMMISSION COORD LAP DRAWN -A P P200 APPROVED WAM FILENAME 460125PT01