HomeMy WebLinkAbout020-99DP/021-99SP (2) Site Utility and Location PlanI STORM WATER DETENTION POND (LAKE #2) I i TRANSFORMER PAD AND TRANSFORMER BY UTILITY CO. GAS METER BY UTILITY CO. BURIED UNDERGROUND PRIMARY ELEC. SERVICE BY UTILITY CO. 4"0 PVC CONDUIT FOR TELEPHONE SERVICE BY THIS CONTRACTOR 120' OF 6 PROPOSED PVC SAN. BLDG. I 2" DOMESTIC WATER LATERIAL 01.00. NEW R/W 5' CONCRETE ASTM D -3034, SERVIDE, TYPE 'L' WALK `'- DR -35. COPPER AT 4' -6" GAS SERVICE COVER BY UTILITY CO. EXISTING NEW R/W R/W _\ GENERAL NOTES EXIST. 8" SAN. SEWER 3 TWO (2) 1 " WATER ETER CONNECTIONS A. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTAINING I. SEE ARCHITECTURAL FOUNDATION PLANS FOR ACTUAL BUILDING T/C= 842.99 TO HIS PHASE OF THE WORK. IT SHALL ALSO BE THE DIMENSIONS. EXISTING CONTRACTORS RESPONSIBILITY TO CONTACT THE OWNER OF THE VARIOUS UTILITIES BEFORE WORK IS STARTED. J. SANITARY SEWER PIPING SHALL BE PVC PIPE, ASTM D3034. INV. SE= 830.35' THE CONTRACTOR SHALL NOTIFY IN WRITING THE OWNERS JOINTS SHALL BE EQUAL TO ASTM C -425, TYPE III FOR COMPRESSION TYPE JOINTS AND INSTALLED WITH AN 0 OR ENGINEERS OF ANY CHANGES, ERRORS OR OMISSIONS FOUND ON THESE PLANS OR IN THE FIELD BEFORE WORK INFILTRATION LIMIT OF 0.158 GAL. /IN. DIA. /HOUR�100 FT. "AIR EXIST. 8" WATER LINE IS STARTED OR RESUMED. PROVIDE FOR CERTIFIED SATISFACTORY TEST AND "MANDRIL TEST" IN ACCORDANCE WITH THE REQUIREMENTS B. NO ROOF DRAINS, FOOTING DRAINS AND /OR SURFACE OF THE UTILITY CO. PROPOSED WATER DRAINS MAY BE CONNECTED TO THE SANITARY SEWER SYSTEM, INCLUDING TEMPORARY CONNECTIONS K. WATER MAIN FOR 3" AND LARGER SIZES SHALL BE w DURING CONSTRUCTION. CENTRIFUGALLY CAST DUCTILE IRON PIPE IN ACCORDANCE W WITH ASA A21.4. TRENCH CONDITION TO BE LAYING C. NO TRAFFIC WILL BE ALLOWED ON PREPARED SUBGRADE PRIOR TO PAVING. NOTEDD. PIPE " TON BE COVER (THICKNESS 54 OCLASS 50.E JOINT TO AS BE U SINGLE RUBBER GASKET PUSH -ON TYPE IN ACCORDANCE D. ALL PIPE OR DRAINAGE STRUCTURES IN TRENCHES UNDER WITH ANSI SPEC A 21.11. PROVIDE FOR DISINFECTION (CHLORINATION) OF THE WATER LINE AND CERTIFIED w PAVED SURFACE SHALL BE BACKFILLED WITH GRANULAR MATERIAL AND COMPACTED BY APPROVED METHODS. SATISFACTORY BACTERIOLOGICAL FIRST DAY AND SECOND z � DAY TEST RESULTS IN ACCORDANCE WITH THE REQUIREMENTS E. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING OF THE UTILITY COMPANY. ALL STATE, CITY, AND COUNTY PERMITS AND PAYING ALL COST THEREOF. L. GATE VALVES SHALL BE CAST IRON BODY, DOUBLE DISC, uI 3 BRONZE MOUNTED, NON- RISING STEM TYPE IN ACCORDANCE F. EXISTING UTILITIES ARE SHOWN APPROXIMATE ONLY. WITH AWWA STANDARD C -500. TO BE FOR 175 PSI WORKING PRESSURE, DIRECT BURIAL SERVICE, WITH MECHANICAL, CONTRACTOR SHALL VERIFY LOCATION, SIZE, MATERIAL AND DEPTH WITH RESPECTIVE OWNERS AND SHALL BELL -END JOINTS, COUNTERCLOCKWISE OPENINGS, 0 -RING O PROTECT THE UTILITIES AT ALL TIMES. PACKING AND 2 IN. TEE WRENCH NUT. VALVES TO HAVE 3 PIECE, ROUND, TYPE CAST IRON BUFFALO ROAD BOX G. THE CONTRACTOR SHALL INSTALL AND /OR CAUSE TO BE WITH 5-1/4 IN. SHAFT, WITH "WATER" CAST IN THE LID. BOXES TO BE FOR NORMAL 4 FT. -6 IN. BUT SHALL INSTALLED ALL EXTERIOR UTILITIES AND SHALL PAY ALL COSTS AND FEES NOT BORNE BY THE LOCAL UTILITIES. BE AS REQUIRED TO SUIT EACH PARTICULAR SETTING DEPTH, LAJ ALL AS NECESSARY TO PROVIDE COMPLETE NEW UTILITY VALVES SHALL BE CLOW, KENNEDY, MUELLER OR APPROVED EQUAL FOR INDIANAPOLIS WATER COMPANY (IWC) PATTERN. = SERVICES AS PER THE REQUIREMENTS AND STANDARDS OF THE RESPECTIVE UTILITY COMPANIES. M. STREET REPAIR SHALL BE IN ACCORDANCE WITH THE H. WHERE WATER LINES AND SANITARY SEWERS CROSS AND STANDARDS OF THE LOCAL AUTHORITY. WATER LINES CANNOT BE PLACED ABOVE THE SEWER WITH A MINIMUM OF 18 INCHES VERTICAL CLEARANCE, THE N. CONTRACTOR SHALL CONSULT WITH THE LOCAL TELEPHONE SEWER MUST BE CONSTRUCTED OF WATER WORKS GRADE UTILITY COMPANY AND SHALL PROVIDE CONDUITS AND WORK AS REQUIRED TO PROVIDE SERVICE TO EACH BUILDING. DUCTILE IRON PIPE WITH MECHANICAL JOINTS WITHIN 10 FEET OF THE WATER LINE. 0. CONTRACTOR SHALL CONSULT WITH THE LOCAL ELECTRIC UTILITY COMPANY AND SHALL PROVIDE CONDUIT, CONDUCTORS AND WORK AS NECESSARY TO PROVIDE ELECTRICAL SERVICE TO EACH BUILDING. 4" BLDG. WASTE LINE BY P.C. \ o Q O 1 N � o S.W.D.P. 4" BLDG. WASTF 7 IC_QAn Ilc' I CWT-- aj GAS METER BY UTILITY CO. TRANSFORMER PAD AND TRANSFORMER BY UTILITY CO. BURIED UNDERGROUND PRIMARY ELEC. SERVICE BY UTILITY CO. 12'-0" 0-1, 4�' (0 \ � W I ' FOR PVC ELEP�ONEI SERVICE i i IE= 836.60' BY THIS CONTRACTOR �9„ I I 12' -0„ 26, 0° 108' -0" 24' O" ,1.R3 CO 1 + i J GAS SERVICE 0 o Q1 BY UTILITY CO. N c�D PROPOSED GROUND SIGN - - � - ----__ 144'-0" I 1 a=� 4" DUCTILE IRON PIPE - - WATER SERVICE 04' -6" COVER - -- a = -- - EXIST 8" SA __ . N. SEWER EXIST. 8" SAN. SEWER --- - - - � - S..J co SAN. SEWER LJ EXISTING T/C= 842.99 rig INV. NW= 832.36' EXISTING INV. NE= 830.60' EXISTING INV. SE= 830.35' EXISTING NEW INV. W= 835.40' 0 PROPOSED Q EXIST. 8" WATER LINE EXIST. 8 SAN. SEWER L Df?/ Vs SAN, SEWER MH —J T/C= 843.38' INV. NW &SE= 833.25' EXIST. 12" WATER MAIN SITE UTILITY AND LOCATION PLAN SAN. SEWER MH T /C= 845.62' NIV. NW &SE= 834.26' PLAN NOTES, 0 CUT -IN NEW SANITARY BLDG. LATERAL CONNECTION INTO EXISTING MANHOLE WITH CORE DRILLED HOLE AND MANUFACTURED LEAK TIGHT SLEEVE FITTING ACCEPTABLE TO THE UTILITY CO. O TAP INTO THE EXISTING WATER MAIN WITH AN 12 "X4" TAPPING SLEEVE AND VALVE IN ACCORDANCE WITH THE REQUIREMENTS OF THE UTILITY CO. O3 REDUCE DOWN FROM A 4" TO A 2" WATER LINE AND PROVIDE FOR INSTALLATION OF DUAL 1" METER PITS WITH ONE (1) 1" METER AND FITTINGS FOR AN ADDITIONAL 1 " METER IN THE SECOND PIT IN THE FUTURE. ALL IN ACCORDANCE WITH THE REQURIEMENTS OF THE UTILITY COMPANY. �4 PROVIDE STRIPPING FOR AN ACCESSIBLE HANDICAP PARKING SITE. SEE DETAIL. O PROVIDE STRIPPING FOR A VAN ACCESSIBLE HANDICAP PARKING SITE WITH SIGNAGE. SEE DETAILS. O PROVIDE CONCRETE WHEELSTOP. (TYPICAL ALONG SIDEWALK). SEE DETAILS. O PROVIDE PAINT STRIPPING AS REQUIRED AND AS DETAILED. (TYPICAL) 1 EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING GAS LINE EXISTING WATER LINE EXISTING UNDERGROUND TELEPHONE EXISTING FORCEMAIN PROPOSED SANITARY SEWER PROPOSED UNDERGROUND ELECTRICAL SERVICE PROPOSED UNDERGROUND TELEPHONE SERVICE PROPOSED WATER LINE PROPOSED GAS SERVICE PROPOSED CLEANOUT LICE UGT W G co A's V J J Z Li., W Z oz Q Q u 0 cn � QJm z Q w U Li-i W cr- ° w U �� O w Q c z � J uI U z Q tY w F— Z Lij W Ly Q _z J V LL z W Q Z 0 z O zQ •� J LLJ Q ) V z O o .J U Q W Q Z cr_ Q Q W 0 O � z = J J O � U D W W z Z � aa- o U U V) Q w� 0 N w O � o a tY O V z rn rn LLJ I Q °j O z r- %%il (III/ /, ` aB E R 0��..•��GISTERE.O % v ' No. 13968 ' ' Cv STATE : � zz �.n . OF . z' �•.• ENO i AN �.•• � • Sl ONA `1 SHEET C2 z PC) '- m - w o O 0 Q c z 3 rn o Q v O m Q C) LAJ = LL U z Z � aa- o U U V) Q w� 0 N w O � o a tY O V z rn rn LLJ I Q °j O z r- %%il (III/ /, ` aB E R 0��..•��GISTERE.O % v ' No. 13968 ' ' Cv STATE : � zz �.n . OF . z' �•.• ENO i AN �.•• � • Sl ONA `1 SHEET C2