Loading...
HomeMy WebLinkAbout020-99DP/021-99SP Alt.Site G-D-EC PlanI 20' BLDG. o SET BACK I 0 PROPOSED '- NEW R/W -- 1 i ------------ EXIST. 0 o N ,- R/W FUTURE 5' CONC. -- WALK BY OTHERS 20' S & U. E/ R/W GENERAL NOTES \ / \\ / STORM WATER DETENTION POND (LAKE #2) NORMAL POOL ELEV.= 833.0' 100 YR. FLOOD ELEV.= 840.2' METAL END SECTION INV. EL = 833.40' (PER PLAT) - - _� . t O 3 PROPOSED NEW x 5' CONC. WALK - - - - - -- _ _!_ IV) 1 n 4 CC 1 � t`� + V _ ,0, i `✓ �X 1 - INLET NO. 4 T /C= 840.67' i INV. W= 835.89' co INV. S= 835.75' Q A. THIS CONTRACTOR SHALL ACCEPT THE SITE AS HE FINDS I. GRADE BETWEEN FINISH ELEVATIONS AND CONTOURS SHOWN I Q IT AND SHALL MAKE ROUGH AND /OR FINISHED GRADING AND THOSE EXISTING ELEVATIONS, CONTOURS OR PAVING ADJUSTMENTS AS NECESSARY TO SUIT FINAL CONDITIONS WHICH ARE TO REMAIN UNDISTURBED, IN SMOOTH PARABOLIC SHOWN HEREON. TRA SITIONS FROM NEW GRADES B. TREES, STUMPS, BRUSH AND DEBRIS SHALL BE REMOVED BY THE CONTRACTOR (UNLESS OTHERWISE NOTED) BEFORE GRADING. C. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTAINING TO HIS PHASE OF THE WORK. IT SHALL ALSO BE THE CONTRACTORS RESPONSIBILITY TO CONTACT THE OWNER OF THE VARIOUS UTILITIES BEFORE WORK IS STARTED. THE CONTRACTOR SHALL NOTIFY IN WRITING THE OWNERS OR ENGINEERS OF ANY CHANGES, ERRORS OR OMISSIONS FOUND ON THESE PLANS OR IN THE FIELD BEFORE WORK IS STARTED OR RESUMED. D. NO ROOF DRAINS, FOOTING DRAINS AND /OR SURFACE WATER DRAINS MAY BE CONNECTED TO THE SANITARY SEWER SYSTEM, INCLUDING TEMPORARY CONNECTIONS DURING CONSTRUCTION. E. NO TRAFFIC WILL BE ALLOWED ON PREPARED SUBGRADE PRIOR TO PAVING. F. ALL PIPE OR DRAINAGE STRUCTURES IN TRENCHES UNDER PAVED SURFACE SHALL BE BACKFILLED WITH GRANULAR MATERIAL AND COMPACTED BY APPROVED METHODS. G. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL STATE, CITY, AND COUNTY PERMITS AND PAYING ALL COST THEREOF. H. EXISTING UTILITIES ARE SHOWN APPROXIMATE ONLY. CONTRACTOR SHALL VERIFY LOCATION, SIZE, MATERIAL AND DEPTH WITH RESPECTIVE OWNERS AND SHALL PROTECT THE UTILITIES AT ALL TIMES. CURVES. PROVIDE SMOOTH N TO EXISTING GRADES AT POINT OF JOINING. SLOPE ALL NEW WORK TO ASSURE DRAINAGE FROM BOTH NEW AND EXISTING SURFACES WITHOUT PONDING. J. MATCH THE LEVELS OF NEW PAVING TO THOSE OF EXISTING PAVINGS AT POINTS WHERE THEY MUST JOIN UNLESS OTHERWISE SHOWN. MINOR ADJUSTMENTS MAY BE MADE TO FINISH ELEVATIONS SHOWN AS REQUIRED TO ACCOMPLISH SUCH MATCHING. K. THE CONTRACTOR SHALL INSTALL AND /OR CAUSE TO BE INSTALLED ALL EXTERIOR UTILITIES AND SHALL PAY ALL COSTS AND FEES NOT BORNE BY THE LOCAL UTILITIES. ALL AS NECESSARY TO PROVIDE COMPLETE NEW UTILITY SERVICES AS PER THE REQUIREMENTS AND STANDARDS OF THE RESPECTIVE UTILITY COMPANIES. L. WHERE WATER LINES AND SANITARY SEWERS CROSS AND WATER LINES CANNOT BE PLACED ABOVE THE SEWER WITH A MINIMUM OF 18 INCHES VERTICAL CLEARANCE, THE SEWER MUST BE CONSTRUCTED OF WATER WORKS GRADE CAST IRON PIPE WITH MECHANICAL JOINTS WITHIN 10 FEET OF THE WATER LINE. M. SEE ARCHITECTURAL FOUNDATION PLANS FOR ACTUAL BUILDING DIMENSIONS. N. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED FOR EROSION PROTECTION IN ACCORDANCE WITH THE SCHEDULE AND RATE INFORMATION DETAILED. 0. ALL FINISHED AREAS WITH A SLOPE GREATER THAN 10% SHALL BE PROVIDED WITH AN EROSION CONTROL BLANKET AS DETAILED. 10' BLDG. -' SET BACK 10' -0" 1 ' / S.W.D-P9 F TOC - 41.95 / 41.45 J /' / / / / ), /� i / / DI A KI KInTCQ. SAW CUT EXISTING CONCRETE ROLL CURB AND START NEW CONCRETE ROLL CURB WITH AN EXPANSION JOINT. SEE DETAIL. SLOPE CURB FOR DRAINAGE TO FLOW AWAY FROM CURB. 2O REMOVE EXISTING CONCRETE ROLL CURB. 3� PROVIDE NEW 5' CONCRETE SIDEWALK ALONG AND ADJACENT TO THE PROPOSED RIGHT -OF -WAY. SEE DETAIL. O PROPOSED NEW CONCRETE ROLL CUR. SEE DETAIL. 5O PROPOSED NEW STRAIGHT CONCRETE CURB. SEE DETAIL. 6O PROPOSED NEW INTEGRAL CONCRETE CURB AND SIDEWALK. SEE DETAILS. O PROVIDE NEW CONCRETE HANDICAP RAMP FOR SIDEWALK ACCESS. SEE DETAIL. 8O DEPRESS PROPOSED NEW CONCRETE ROLL CURB TO BE SUITABLE FOR A NEW CONCRETE HANDICAP RAMP BY OTHERS. 9O PROPOSED NEW 6" CONCRETE PAD FOR DUMPSTER STORAGE. SEE DETAIL. SEE ARCHITECTURAL PLANS FOR EXACT DIMENSIONS. 10 TYPICAL DOWNSPOUT AND DOWNSPOUT CONNECTION TO A 6" DIAMETER HDPE PIPE STORM LATERAL COLLECTOR. SEE ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DETAILS. 11 PROPOSED NEW ASPHALT HANDICAP RAMP. SEE DETAIL. 12 STANDARD DUTY ASPHALT PAVEMENT. SEE DETAIL. 13 HEAVY DUTY ASPHALT PAVEMENT. SEE DETAIL. 14 CORRUGATED POLYETHYLENE PLASTIC PIPE (HDPE). AASHTO M294, TYPE S. WITH SMOOTH WATERWAY AND GASKETED JOINTS. (TYPICAL) 15 24'WD X 50'LG STABLE CONSTRUCTION ENTRANCE ACCESS DRIVE CONSISTING OF A MINIMUM OF 6" ISHD #2'S. 16 SLOPE PROPOSED ACCEL./DECEL. LANE AT '/4"/ FT. TO DRAIN. (TYPICAL) 17 REMOVE EXISTING INLET FRAME AND GRATE AND DELIVER TO THE CITY'S INVENTORY. ADJUST EXISTING STRUCTURE AND PROVIDE NEW FLAT DOUBLE INLET CASTING TO SUIT REVISED STRUCTURE. INLET CASTING SHALL MEET CITY DEPT. OF ENGINEERING APPROVAL INCLUDING A BICYCLE SAFE GRATE. 18 RAISE EXISTING MANHOLE STRUCTURE AND CASTING TO NEW FINISHED PAVEMENT GRADE +'/4 ". WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE REQUIREMENTS OF THE UTILITY CO. ROUTE NEW ROLL CURB AROUND THE CASTING AND PROVIDE AN EXPANSION JOINT BETWEEN THE CURB AND THE CASTING. 19 RELOCATE SIGN AS REQURIED BY THE CITY ENGINEERING DEPARTMENT. / - �— IIVLtI Ivu. o 41.73 - - - - "'Mmano now T /C= 840.60' INV. S= 836.50 4 5 5 41.72 INV. E= 836.35 42.29 -- - -- i �� _ _° TOC / J r 4 TOC TO I 7 3. 42.2 4 -- _ - - WE 6 — - - -4 -� - - - -^ � - 18 t '-- = - _ -- --- - _ _ _ - - -- _ WALK (Y OTHERS) - •- - -"`" FUTURE 5' CONC O ME ME 250'0" -a ( '' CONC. WALK 1 2 - > J I N Ve - ---ter AF `, -IGUBLF CURB INLET T.C. = 841.05 ' I �L= 840.44 APPROX. !- OCATION 6" P'A'C FORCE MANN (FM; ALT. SITE GRADING, DRAINAGE AND EROSION CONTROL PLAN SCALE. 1" = 30' 1 C ^CLIfY `'. Exist. Contour Proposed Contour (Add 800') 21" 1 X Exist. Spot Elevation 42.55 Spot Elevation (Add 800') ITL /M.S. /TOC Flowline /Match Existing /Top of Curb Drainage Divide 0.50% --- ---- Proposed Swale (Street or Lot) w /Slope Direction of Drainage 11 V J Z w v� Existing Sanitary Sewer w Z oz Q J w0 Q U O Z � Z � Cr >-Q m w Uw w Q j z Q Proposed Storm Sewer Q D O In U m LAJ LA- Q � U W Q � J Q z a Q U J LLI w f J 0 LLd w cc z • �"' 0 Z z Ld U U C� Z z co J w V W z • O Z U Q W Q W CD z � w can Z M Q 0 • Cr. z O U Z � Q Q CD W H 0 W H Q 0 w z g Z w o : J Lj Ov w iz o U U Q w J LLI H o Q O CL a_ w O °o z Q LLJrn rn I I Q o0 0 � I I 0 0 Z — (V Existing Force Main Existing Sanitary Sewer pB E R� -•• ��S'� //� • � P, Existing Gas Line /M V/ m m N0. 13968 Z ►O -o s psTATE t � Existing Water Line �� �HO -Z �.r �2 � T- o w Q ai z Q Proposed Storm Sewer 0 w (Yj 3 O Proposed Bldg. Storm Lateral Collector m LAJ LA- Q Silt Fence U SHEET 0 w z g Z w o : J Lj Ov w iz o U U Q w J LLI H o Q O CL a_ w O °o z Q LLJrn rn I I Q o0 0 � I I 0 0 Z — (V Proposed Concrete Walk /Pavement Proposed Heavy Duty Asphalt Pvmt Section ET-0 Straw Bale Drop Inlet Protection C1 Existing Force Main Existing Sanitary Sewer pB E R� -•• ��S'� //� • � P, Existing Gas Line `�����,,••��STE O;' s v� N0. 13968 Existing Buried Telephone Line -o s psTATE t � Existing Water Line �� �HO -Z �.r �2 � Existing Storm Sewer 'pNALI���`� / Proposed Storm Sewer 11 1 S Proposed Bldg. Storm Lateral Collector SF Silt Fence SHEET Proposed Concrete Walk /Pavement Proposed Heavy Duty Asphalt Pvmt Section ET-0 Straw Bale Drop Inlet Protection C1