HomeMy WebLinkAboutA-20m
m
m
N
[D
O
SEALANT
(TYPICAL)
VAPOR BARRIER
SEAL ALL OVERLAPS
AND PENETRATIONS
DETAIL -4
SCALE: 3/4 " -1' -0"
LANT
PICAL)
'OR
tR 1 ER-
iL ALL
'RLAPS
PENTRATIONS
DETAIL C /A -10
SCALE: 1 1/2 " =1' -0" A /A- 11(SIM.)
VAPOR BARRIER SPLICE
STRIP PLACED DURING
ROUGH FRAMING
SEALANT (TYP)
VAPOR BARRIER —
SEAL ALL OVERLAPS
AND PENETRATIONS
VAPOR BARRIER SPLICE
STRIP PLACED DURING
ROUGH FRAMING
DETAIL D /A -11
SCALE: 1 1/2 " =1' —O"
DETAIL_ B A /A -6
SCALE: 3/4' =1' -0'
VAPOR BARRIER GENERAL NOTES
1. INSULATION IS NOT SHOWN IN
DETAILS FOR CLARITY
2. DETAILS HAVE ELEMENTS SLIGHTLY
EXPANDED FOR VAPOR BARRIER
PLACMENT AND SPLICING CLARIFICATION
3. TIGHTLY SEAL ALL OVERLAPS AS REQUIRED
4. ALL VAPOR BARRIER SPLICING STRIPS
SHALL BE SIZED TO ALLOW AMPLE
OVERLAP AND SHALL BE PLACED DURING FRAMING
S. WHERE VAPOR BARRIER PASSES THROUGH
STUD WALL FRAMING. SLIT VAPOR BARRIER
SPLICING STRIP AS REQUIRED AT STUDS.
THEN SECURE AND SEAL TO SOLID BLOCKING.
S. SEAL AROUND ALL OBJECTS THAT
PENETRATE THE VAPOR BARRIER. SEE
DETAIL •H" THIS SHEET.
7. FOR RECESSED SPEAKERS IN ROOM 110 THAT
PENETRATE VAPOR BARRIER. CONTINUE VAPOR
BARRIER OVER SPEAKER AND SEAL ALL OVERLAPS.
ARRIER
L OVERLAPS
" ETRQT I ONS
VAPOR B)
STRIP Pt
ROUGH FE
SEALANT
(TYPICAL
''APOR BARRIER
►EAL ALL OVERLAPS
►ND PENETRATIONS
iEALANT (TYP)
VAPOR BARRIER
SEAL ALL OVERLAPS
AND PENETRATIONS
DETAIL C B /A -6
SCALE: 3/4 " =1' -0"
BOTTOM CHORD OF
ROOF TRUSS
VAPOR BARRIER —
SEAL ALL OVERLAPS
AND PENETRATIONS
CONTINUOUS 2X4
NAILED TO ROOF
TRUSS AFTER PLACING
VAPOR BARRIER
HANGER ROD OR
STRAP TO SUPPORT
DUCTWORK. SEE
MECHANICAL SHEETS
DETAIL D /M -10
SCALE: 1 1/2' -1' -0"
SEALANT
( TYP. )
(APOR BARRIER SPLICE
)TRIP PLACE DURING
LOUGH FRAMING
DETAIL e /A -11
SCALE: 1
1
DETAIL-( D D /A -13
SCALE: 3/4 " =1' -0"
CEILING OR WALL FRAMING WHERE
OCCURS
VAPOR BARRIER— TURN IN
AND WRAP AROUND PENETRATING
OBJECT.
TAPE ALL
AROUND
OBJECT PENETRATING
THE VAPOR BARRIER
TYPICAL PENETRATION DETAIL
SCALE: NONE
VAPOR
BARRIER —
SEAL ALL
OVERLAPS AND
PENETRATIONS
DETAIL C /A -11
SCALE: 1 1/2 "
VAPOR BARRIER SPLICE
STRIP PLACED DURING
ROUGH FRAMING
INTERIOR WALL
SEALANT (TYPICAL)
VAPOR BARRIER
EXTERIOR WALL
(NON SHEAR WALL)
DETAIL
(Sy SCALE: 1 1/2 " =1' -0"
VAPOR BARRIER
SPLICE STRIP
PLACED DURING
ROUGH FRAMING
TRUSSED RAFTER
5/8• GYPSUM BC
ON 1/2" SHEATF
VAPOF
SEAL
AND AND F
VAPOF
STR I F
ROUGE
SEE r
SAL SEAL!
cTYP
DETA I L B /A -3
SCALE: 3/4 " =1' -0" E
HEAD J F /A -18
SCALE. 1 1/2 " =1' -0"
SHEAR WALL DETAIL
SCALE: 3/4 " =1' -0•
SEALANT (TYPICAL)
VAPOR BARRIER —
SEAL ALL OVERLAPS
AND PENETRATIONS
SHEAR WALL
D /A -6
TRUSS TR -2
LANT (TYPICAL)
'OR BARRIER —
►L ALL OVERLAPS
) AROUND ALL
JETRATIONS
c\ . S Nqp
aJ�
Q- N0. i
01 G 14 ITti
E 9
U) t ff. i w
3: j 2
ww J
N ol
�p
0
� W
QU�Q� LD
132M25
PROJECT NUMBER
�- O5�v
DATE
Ll-J
1
lZ
Q
�--- -�
<
O
SHEET NUMBER
SU�U
0 F '�