HomeMy WebLinkAboutM-10c- m m J Q r c r c S. A. DUCT OPPOSED BLADE DAMPER FIRE DAMPER SIDE WALL REGISTER WALL CEILING OF CORRIDOR )ETAIL IS SIMILAR FOR V AIR GRILLE h FIRE DAMPER. FIRE DAMPER INSTALLATION- SIDEWALL SCALE: NONE 2 "X4" RUNNERS (TYPICAL) •10 X 3/4" SELF TAPPING CADMIUM PLATED SHEET METAL SCREWS TO ANCHOR STRAPS TO DUCT. ALL STRAPS TO BE TIGHT AGAINST DUCT AND SUPPORT MEMBERS.(TYPICAL) — HANGER STRAPS —� NO POP RIVETS ALLOWED i NOTE: PROVIDE SUPPORT ON ALL BRANCH DUCT RUNOUTS. MINIMUM OF TWO SUPPORTS ON BRANCH DUCTS OVER 6' -0" IN LENGTH. NOTE: DUCT SHALL BE WRAPPED EXTERNALLY AS PER THE SPECIFICATIONS. INSULATION BOTTOM OF TRUSS CHORD �r 5/8" GYPSUM BOARD y'r •10 X1 -1/2" CADMIUM L-VAPOR ~— PLATED SCREWS (TYP.) BARRIER (2) •10 X 3" WOOD SCREWS MUST BE • EACH TRUSS CHORD (TYP.) CONTINUOUS BEHIND GYP. BOARD. +10 X 3/4" SELF 1 -1/4' MIN. TAPPING CADMIUM PLATED PENETRATION SHEET METAL SCREWS TO ANCHOR STRAPS TO DUCT. ALL STRAPS TO BE TIGHT AGAINST DUCT AND SUPPORT wEMBERS.(TYPICAL) F--- HANGER STRAPS NO POP RIVETS ALLOWED T " DUCT STRAP HANGER DETAIL SCALE: NONE (1) TRANSVERSE REINFORCING SIZE IS DETERMINED BY DIMENSION OF SIDE TO WHICH ANGLE IS APPLIED. DUCT CONSTRUCTION DETAIL SCALE: NONE I FASTEN RIGID DUCT — TO SPIN -IN FITTING W/ :10 X 3/4" SHEET METAL SCREWS 1 NOTE: IN AREAS WHERE FIRE DAMPERS ARE REQUIRED PROVIDE DEEP ROUND TO RECTANGULAR OR BUTT WRAP AGAINST SQUARE ADAPTER AND BUILD MAIN DUCT GYPSUM BOARD ENCLOSURE. WRAP ALL BRANCH DUCTS AND COVER CONNECTIONS WITH DUCT WRAP. SEE SPECIFICATIONS SHEET METAL SPIN -IN FITTING W/ EXTRACTOR CONE BALANCE DAMPER W// LOCKING QUADRANT ROUND RIGID = DUCT 1" X 18 GAGE SHEET METAL SUPPORT STRAP SCREW STRAP HANGER TO STRUCTURE ABOVE STAINLESS STEEL SCREW DRIVER OPERAATED BAND (TYPICAL) -, PROVIDE 3/4" HAT CHANNELS, BOTH DIRECTIONS. FOR DIFFUSER SUPPORT DIFFUSER TYPICAL DIFFUSER CONNECTION DETAIL SCALE: NONE METAL FASTENERS: TRANSVERSE REINFORCING (1) OMARK INSUL -PINS. AT JOINTS OR GRIP NAILS. UL 181 LABELED INSULATED FLEX DUCT GRIP NAILS SHALL BE INSTALLED "GRIPNAIL HAMMER" OR SEE SPECS. NO SAGS OR SHARP TURNS ALLOWED. MAXIMUM RUN LIMITED TO 3' -0". BY AIR BY AUTOMATIC FASTENER EQUIPMENT. STRETCH DUCT RUN FOR SMOOTH INTERIOR. SHEET METAL MINIMUM DIMENSION OF LONGEST SIDE. INCHES SHEET METAL GAGE ( ALL FOUR SIDES) REINFORCING ANGLE SIZE AND MAXIMUM LONGITUDINAL SPACING AC BETWEEN TRANSVERSE JOINTS a /OR INTERMEDIATE REINFORCING MIN. I , �n� DRIVE SLIP PLAIN S SLIP ��- _ HEMMED S SLIP H ALTER'NT BAR SLIP I H REIN- FORCED BAR SLIP RECOM- MENDED GAGE I RECOM- MENDED GAGE RECOM- MENDED GAGE RECOM- MENDED GAGE UP THRU 12 26 NONE REQUIRED 1 26 26 24 24 13 - 18 24 NONE REQUIRED 1 24 24 24 24 19 - 30 24 1 "X1 "X1 /8" • 60 IN I - 24 24 24 31 - 42 22 I"X1'X1 /8' • 60 IN 1 - - 22 22 (1) TRANSVERSE REINFORCING SIZE IS DETERMINED BY DIMENSION OF SIDE TO WHICH ANGLE IS APPLIED. DUCT CONSTRUCTION DETAIL SCALE: NONE I FASTEN RIGID DUCT — TO SPIN -IN FITTING W/ :10 X 3/4" SHEET METAL SCREWS 1 NOTE: IN AREAS WHERE FIRE DAMPERS ARE REQUIRED PROVIDE DEEP ROUND TO RECTANGULAR OR BUTT WRAP AGAINST SQUARE ADAPTER AND BUILD MAIN DUCT GYPSUM BOARD ENCLOSURE. WRAP ALL BRANCH DUCTS AND COVER CONNECTIONS WITH DUCT WRAP. SEE SPECIFICATIONS SHEET METAL SPIN -IN FITTING W/ EXTRACTOR CONE BALANCE DAMPER W// LOCKING QUADRANT ROUND RIGID = DUCT 1" X 18 GAGE SHEET METAL SUPPORT STRAP SCREW STRAP HANGER TO STRUCTURE ABOVE STAINLESS STEEL SCREW DRIVER OPERAATED BAND (TYPICAL) -, PROVIDE 3/4" HAT CHANNELS, BOTH DIRECTIONS. FOR DIFFUSER SUPPORT DIFFUSER TYPICAL DIFFUSER CONNECTION DETAIL SCALE: NONE 1" THICK DUCT LINER SHEET W TOP AND BOT1 SECTIONS OF SHALL OVERLI THE SIDES DUCT LINER ALL ENDS OF LINER TO BE COATED W/ ADHESIVE. (MIRACLE PF 96) ENDS OF LINER SHALL BE NOT MORE THAN 2' BUTTED FIRMLY TOGETHER. �— FROM EDGE OF LINER. FACTORY FABRICATED ROUND TO RECTANGULAR OR SQUARE ADAPTER SEE DIFFUSER SCHEDULE DUCT- L I NER DETA I L SCALE: NONE NOTE: >e L =1/4 W (4" MINIMUM.) MAIN AIR DUCT SUPPLY OR RETURN AIR DUCT CONNECTION DETAIL SCALE: NONE L i rvcn IV vim. ADHERED TO DUCT W /100% ADHESIVE (MIRACLE PF96) USE DAMPER WHEN INDICATED ON SHEET M -1 AIR BRANCH DUCT (TYPICAL) Ect A tco SFEgfo 9 0 no. : 9356 a • .� LAO �p SIA(( 40IA0 car:' au�nu +r• • W Z aw LU = Z a� Z ZLu a� J Z J UD Q V cn uj ZQ Z 0 U v' Z • —J a J Q� w LL- • LLi Z �g PROJECT NUMBER DATE CD l� r LLJ --1 0 ..—.1 C)L- H CD t--- -1 U V E2 Ej Cl V LL- 0 SHEET NUMBER OF It) 1 METAL FASTENERS: OMARK INSUL -PINS. DURO DYNE FASTENERS OR GRIP NAILS. UL 181 LABELED INSULATED FLEX DUCT GRIP NAILS SHALL BE INSTALLED "GRIPNAIL HAMMER" OR SEE SPECS. NO SAGS OR SHARP TURNS ALLOWED. MAXIMUM RUN LIMITED TO 3' -0". BY AIR BY AUTOMATIC FASTENER EQUIPMENT. STRETCH DUCT RUN FOR SMOOTH INTERIOR. SHEET METAL ADJUSTABLE ROUND DUCT ELBOW *10 X 3/4" SELF TAPPING CADMIUM PLATED SHEET METAL SCREWS TO CONNECT ADJUSTABLE ELBOW TO DIFFUSER ADAPTER CRIMP JOINT BEAD (TYPICAL) • ROUND SHEET METAL DUCT CONNECTER BETWEEN ADJUSTABLE ELBOW I ►11 AND DIFFUSER ADAPTER 1111 1111 BUTT WRAP AGAINST ADAPTER 1" THICK DUCT LINER SHEET W TOP AND BOT1 SECTIONS OF SHALL OVERLI THE SIDES DUCT LINER ALL ENDS OF LINER TO BE COATED W/ ADHESIVE. (MIRACLE PF 96) ENDS OF LINER SHALL BE NOT MORE THAN 2' BUTTED FIRMLY TOGETHER. �— FROM EDGE OF LINER. FACTORY FABRICATED ROUND TO RECTANGULAR OR SQUARE ADAPTER SEE DIFFUSER SCHEDULE DUCT- L I NER DETA I L SCALE: NONE NOTE: >e L =1/4 W (4" MINIMUM.) MAIN AIR DUCT SUPPLY OR RETURN AIR DUCT CONNECTION DETAIL SCALE: NONE L i rvcn IV vim. ADHERED TO DUCT W /100% ADHESIVE (MIRACLE PF96) USE DAMPER WHEN INDICATED ON SHEET M -1 AIR BRANCH DUCT (TYPICAL) Ect A tco SFEgfo 9 0 no. : 9356 a • .� LAO �p SIA(( 40IA0 car:' au�nu +r• • W Z aw LU = Z a� Z ZLu a� J Z J UD Q V cn uj ZQ Z 0 U v' Z • —J a J Q� w LL- • LLi Z �g PROJECT NUMBER DATE CD l� r LLJ --1 0 ..—.1 C)L- H CD t--- -1 U V E2 Ej Cl V LL- 0 SHEET NUMBER OF It) 1