S. A. DUCT
OPPOSED BLADE DAMPER
FIRE DAMPER
SIDE WALL REGISTER
WALL
CEILING OF CORRIDOR
)ETAIL IS SIMILAR FOR
V AIR GRILLE h FIRE DAMPER.
FIRE DAMPER INSTALLATION- SIDEWALL
SCALE: NONE
2 "X4" RUNNERS (TYPICAL)
•10 X 3/4" SELF
TAPPING CADMIUM PLATED
SHEET METAL SCREWS
TO ANCHOR STRAPS TO
DUCT.
ALL STRAPS TO BE TIGHT
AGAINST DUCT AND
SUPPORT MEMBERS.(TYPICAL)
— HANGER STRAPS —�
NO POP RIVETS ALLOWED
i
NOTE:
PROVIDE SUPPORT ON ALL
BRANCH DUCT RUNOUTS.
MINIMUM OF TWO SUPPORTS
ON BRANCH DUCTS OVER
6' -0" IN LENGTH.
NOTE:
DUCT SHALL BE WRAPPED EXTERNALLY
AS PER THE SPECIFICATIONS.
INSULATION BOTTOM OF TRUSS CHORD
�r 5/8" GYPSUM BOARD
y'r •10 X1 -1/2" CADMIUM L-VAPOR
~— PLATED SCREWS (TYP.) BARRIER
(2) •10 X 3" WOOD SCREWS MUST BE
• EACH TRUSS CHORD (TYP.) CONTINUOUS
BEHIND
GYP. BOARD.
+10 X 3/4" SELF 1 -1/4' MIN.
TAPPING CADMIUM PLATED PENETRATION
SHEET METAL SCREWS
TO ANCHOR STRAPS TO
DUCT.
ALL STRAPS TO BE TIGHT
AGAINST DUCT AND
SUPPORT wEMBERS.(TYPICAL)
F--- HANGER STRAPS
NO POP RIVETS ALLOWED
T
"
DUCT STRAP HANGER DETAIL
SCALE: NONE
(1) TRANSVERSE REINFORCING SIZE IS DETERMINED BY
DIMENSION OF SIDE TO WHICH ANGLE IS APPLIED.
DUCT CONSTRUCTION DETAIL
SCALE: NONE
I
FASTEN RIGID DUCT —
TO SPIN -IN FITTING
W/ :10 X 3/4" SHEET
METAL SCREWS
1
NOTE:
IN AREAS WHERE FIRE DAMPERS
ARE REQUIRED PROVIDE DEEP
ROUND TO RECTANGULAR OR
BUTT WRAP AGAINST SQUARE ADAPTER AND BUILD
MAIN DUCT GYPSUM BOARD ENCLOSURE.
WRAP ALL BRANCH DUCTS
AND COVER CONNECTIONS
WITH DUCT WRAP. SEE
SPECIFICATIONS
SHEET METAL
SPIN -IN FITTING
W/ EXTRACTOR CONE
BALANCE DAMPER W//
LOCKING QUADRANT
ROUND RIGID =
DUCT
1" X 18 GAGE
SHEET METAL
SUPPORT STRAP
SCREW STRAP HANGER
TO STRUCTURE ABOVE
STAINLESS STEEL
SCREW DRIVER
OPERAATED BAND
(TYPICAL) -,
PROVIDE 3/4" HAT
CHANNELS, BOTH
DIRECTIONS. FOR
DIFFUSER SUPPORT
DIFFUSER
TYPICAL DIFFUSER CONNECTION DETAIL
SCALE: NONE
METAL FASTENERS:
TRANSVERSE REINFORCING (1)
OMARK INSUL -PINS.
AT
JOINTS
OR GRIP NAILS.
UL 181 LABELED INSULATED FLEX DUCT
GRIP NAILS SHALL BE INSTALLED
"GRIPNAIL HAMMER" OR
SEE SPECS. NO SAGS OR SHARP TURNS
ALLOWED. MAXIMUM RUN LIMITED TO 3' -0".
BY AIR
BY AUTOMATIC FASTENER EQUIPMENT.
STRETCH DUCT RUN FOR SMOOTH INTERIOR.
SHEET METAL
MINIMUM
DIMENSION
OF
LONGEST
SIDE.
INCHES
SHEET
METAL
GAGE
( ALL
FOUR
SIDES)
REINFORCING
ANGLE SIZE
AND MAXIMUM
LONGITUDINAL SPACING
AC
BETWEEN
TRANSVERSE
JOINTS a /OR
INTERMEDIATE
REINFORCING
MIN.
I ,
�n�
DRIVE
SLIP
PLAIN
S SLIP
��- _
HEMMED
S SLIP
H
ALTER'NT
BAR SLIP
I H
REIN-
FORCED
BAR SLIP
RECOM-
MENDED
GAGE
I RECOM-
MENDED
GAGE
RECOM-
MENDED
GAGE
RECOM-
MENDED
GAGE
UP THRU 12
26
NONE REQUIRED
1
26
26
24
24
13 - 18
24
NONE REQUIRED
1
24
24
24
24
19 - 30
24
1 "X1 "X1 /8" • 60 IN
I
-
24
24
24
31 - 42
22
I"X1'X1 /8' • 60 IN
1
-
-
22
22
(1) TRANSVERSE REINFORCING SIZE IS DETERMINED BY
DIMENSION OF SIDE TO WHICH ANGLE IS APPLIED.
DUCT CONSTRUCTION DETAIL
SCALE: NONE
I
FASTEN RIGID DUCT —
TO SPIN -IN FITTING
W/ :10 X 3/4" SHEET
METAL SCREWS
1
NOTE:
IN AREAS WHERE FIRE DAMPERS
ARE REQUIRED PROVIDE DEEP
ROUND TO RECTANGULAR OR
BUTT WRAP AGAINST SQUARE ADAPTER AND BUILD
MAIN DUCT GYPSUM BOARD ENCLOSURE.
WRAP ALL BRANCH DUCTS
AND COVER CONNECTIONS
WITH DUCT WRAP. SEE
SPECIFICATIONS
SHEET METAL
SPIN -IN FITTING
W/ EXTRACTOR CONE
BALANCE DAMPER W//
LOCKING QUADRANT
ROUND RIGID =
DUCT
1" X 18 GAGE
SHEET METAL
SUPPORT STRAP
SCREW STRAP HANGER
TO STRUCTURE ABOVE
STAINLESS STEEL
SCREW DRIVER
OPERAATED BAND
(TYPICAL) -,
PROVIDE 3/4" HAT
CHANNELS, BOTH
DIRECTIONS. FOR
DIFFUSER SUPPORT
DIFFUSER
TYPICAL DIFFUSER CONNECTION DETAIL
SCALE: NONE
1" THICK DUCT LINER
SHEET W
TOP AND BOT1
SECTIONS OF
SHALL OVERLI
THE SIDES
DUCT LINER
ALL ENDS OF LINER
TO BE COATED W/ ADHESIVE.
(MIRACLE PF 96)
ENDS OF LINER SHALL BE
NOT MORE THAN 2' BUTTED FIRMLY TOGETHER.
�— FROM EDGE OF LINER.
FACTORY FABRICATED
ROUND TO RECTANGULAR
OR SQUARE ADAPTER
SEE DIFFUSER SCHEDULE DUCT- L I NER DETA I L
SCALE: NONE
NOTE:
>e
L =1/4 W (4" MINIMUM.)
MAIN AIR
DUCT
SUPPLY OR RETURN AIR
DUCT CONNECTION DETAIL
SCALE: NONE
L i rvcn IV vim.
ADHERED TO DUCT
W /100% ADHESIVE
(MIRACLE PF96)
USE DAMPER WHEN
INDICATED ON SHEET M -1
AIR BRANCH
DUCT (TYPICAL)
Ect
A tco SFEgfo 9 0
no. :
9356 a •
.�
LAO
�p SIA((
40IA0 car:'
au�nu +r•
•
W
Z
aw
LU
= Z
a�
Z
ZLu
a�
J Z
J
UD Q
V cn uj ZQ
Z
0
U v' Z
• —J
a J
Q�
w
LL-
• LLi Z
�g
PROJECT NUMBER
DATE
CD
l�
r
LLJ
--1 0
..—.1 C)L- H
CD
t--- -1 U
V E2 Ej Cl
V
LL-
0
SHEET NUMBER
OF It)
1
METAL FASTENERS:
OMARK INSUL -PINS.
DURO DYNE FASTENERS
OR GRIP NAILS.
UL 181 LABELED INSULATED FLEX DUCT
GRIP NAILS SHALL BE INSTALLED
"GRIPNAIL HAMMER" OR
SEE SPECS. NO SAGS OR SHARP TURNS
ALLOWED. MAXIMUM RUN LIMITED TO 3' -0".
BY AIR
BY AUTOMATIC FASTENER EQUIPMENT.
STRETCH DUCT RUN FOR SMOOTH INTERIOR.
SHEET METAL
ADJUSTABLE ROUND
DUCT ELBOW
*10 X 3/4" SELF
TAPPING CADMIUM
PLATED SHEET METAL
SCREWS TO CONNECT
ADJUSTABLE ELBOW
TO DIFFUSER ADAPTER
CRIMP JOINT BEAD
(TYPICAL)
•
ROUND SHEET METAL DUCT
CONNECTER BETWEEN
ADJUSTABLE ELBOW
I ►11 AND DIFFUSER ADAPTER
1111 1111 BUTT WRAP AGAINST ADAPTER
1" THICK DUCT LINER
SHEET W
TOP AND BOT1
SECTIONS OF
SHALL OVERLI
THE SIDES
DUCT LINER
ALL ENDS OF LINER
TO BE COATED W/ ADHESIVE.
(MIRACLE PF 96)
ENDS OF LINER SHALL BE
NOT MORE THAN 2' BUTTED FIRMLY TOGETHER.
�— FROM EDGE OF LINER.
FACTORY FABRICATED
ROUND TO RECTANGULAR
OR SQUARE ADAPTER
SEE DIFFUSER SCHEDULE DUCT- L I NER DETA I L
SCALE: NONE
NOTE:
>e
L =1/4 W (4" MINIMUM.)
MAIN AIR
DUCT
SUPPLY OR RETURN AIR
DUCT CONNECTION DETAIL
SCALE: NONE
L i rvcn IV vim.
ADHERED TO DUCT
W /100% ADHESIVE
(MIRACLE PF96)
USE DAMPER WHEN
INDICATED ON SHEET M -1
AIR BRANCH
DUCT (TYPICAL)
Ect
A tco SFEgfo 9 0
no. :
9356 a •
.�
LAO
�p SIA((
40IA0 car:'
au�nu +r•
•
W
Z
aw
LU
= Z
a�
Z
ZLu
a�
J Z
J
UD Q
V cn uj ZQ
Z
0
U v' Z
• —J
a J
Q�
w
LL-
• LLi Z
�g
PROJECT NUMBER
DATE
CD
l�
r
LLJ
--1 0
..—.1 C)L- H
CD
t--- -1 U
V E2 Ej Cl
V
LL-
0
SHEET NUMBER
OF It)
1