DOMESTIC TAPS d PROVIDE
PJ.V,
(2) - 2' TYPE 'IC Cu DOMESTIC
WATER LINES W/ 2' VALVE
TO INSIDE METER IN
SPRWLER ROOM
ARBORS OF CARMEL LIMITED PARTNERSHIP 4l, /
ZONED M -3 N
SANITARY MANHOLE
ALL NEW PAVEMtNI FUN 1U Abr11A1_1 rAlrt
SHALL BE 1.5" HMA #11 SURFACE, ON 2" HMA
#8 BINDER, ON 5" No. 53 CRUSHED STONE.
PAVING MUST BE COMPLETED WITHIN ONE PAVING
SEASON.
EXISTING EDGE OF ADAMS ST. SHALL BE SAW
CUT FOR INSTALLATION OF NEW PAVEMENT. ANY
NEW PAVEMENT IN ADAMS ST. R/W SHALL BE
1.5" HMA #11 SURFACE, ON 2" HMA #8 BINDER,
ON 3" HMA #5D BASE, ON 7" No. 53 CRUSHED
STONE, ON 4" No. 2 CRUSHED STONE OR MATCH
EXISTING WHICHEVER IS GREATER
HOLEY MOLEY SAYS
"DIG SAFELY"
"IT'S THE LAW"
CALL 2 WORKING L14YS BEFORE YOU DIG
CALL TOLL FREE
PER INDIANA STATE LAW IC8 -1 -26.
IT IS AGAINST THE LAW TO EXCAVATE
WITHOUT NOTIFYING THE UNDERGROUND
LOCATION SERVICE TWO (2) WORKING
DAYS BEFORE COMMENCING WORK.
vt
V4
SEE DETAILS ON Cl FOR ADA
RAMP AT INTERSECTION
o_
V
X37,64' S 9'13'44" E -
30'x20' C�ONy�r. D1 h6ftTER PAD _1- _ , 56
INSIDE (2) DUAL I' WATER W/ b' I��I"" AASCARY WALL
METERS PER CARMEL UTILITIES�S E DETAIL ON C5
PROVIDE RPZ BACKFLOIU
PREVENTER6 / / �✓ /
. RAP
E DTL. 6 /C5
T a A
010 S7,0
.6 13Ult ASONR Y
Q• It. NG
DOMESTIC SERVICE
VERIFY TYPE, SIZE 4
N /!
29'55 „....W...281 gj
V
w
� / ".,.� .. ...........E 5
0 '
�� ro
TYPE, SIZE A LOCATION
-� -- ___
SANITARY MANHOLE \ SANITARY MANHOLE
\ �;i®r�v
/
\ L EXISTING STORM MANHOLE ro
BLOCK '1 =/
TRACTOR TO INSTALL SICdJAGE �- EXISTING STORM MANHOLE (BURIED)
CTING VEHICLES TO BACK NTO /
i »v Gc A�C4 AI AV_ A,'Y AMr GT
RELEASED FOR CONSTRUCTION
Subiect to compliance with all regulations
of State and Local Codes.
DEPT OF COMMUNITY SERVICES
CITY OF CARMEL / CLkY TOWNSHIP
INDIANA
N
1 /5' ALUMINUM PANEL
SCREEN PRINT 5YM50L
COLORS SELECTED BY ARCH.
HANDICAPPED SYMBOL
2' 60. ALUMINUM POST
FINISH AS PER SPECIFICATIONS
FINISH GRADE
EARTH
CONCRETE FOOTING
NOT TO SCALE
,
71
CARMEL ENGINEERING NOTES:
1. For installation of storm mains, water mains, sanitary mains, water service laterals,
sanitary service laterals under city streets, regardless of the jurisdiction of the utility, the
minimum cover from the top of the installed pavement to the top of the installed pipe sholl
be the pavement section thickness (all bituminous and aggregate material above the
subgrade) plus 1' -0 ". If the standard practice of the utility that has jurisdiction over the
installation has o more stringent cover requirement, the more stringent requirement sholl
govern.
2. Bedding, hounching and initial bockfill materials, placement and compaction for water
moins, water service laterals, sanitary mains and sanitary service laterals under and within
5 -feet of pavement shall be in accordance with the standard practice of the utility that has
jurisdiction over the installation. Final bockfill for water mains, water service laterals, sanitary
mains and sanitory service laterals under and within 5 -feet of pavement sholl be in
accordance with the standard practice of the utility that has jurisdiction over the installation.
Final bockfill for water moins, water service laterals, sanitary mains and sanitary service
laterals under and within 5 -feet of pavement shall be B- Borrow for Structure Bockfill
meeting the material requirements of the INDOT and sholl be compacted in 6 -inch maximum
lifts to not less than 95% Standard Proctor Density for the entire depth of the material
placed. The bockfill for the top 6- inches of the excavation below the start of the aggregate
sub -base of the pavement sholl be No. 53 Stone meeting the material requirements of the
INDOT and shall be compacted to not less than 95% Standard Proctor Density. If the
standard practice of the utility that has jurisdiction over the installation has o more
stringent final bockfill requirement, the more stringent requirement sholl govern.
3. Bedding, hounching, and initial bockfill for all RCP installations shall be B- Borrow for
Structure Bockfill meeting the material requirements of the INDOT. Bedding sholl be placed in
the trench bottom such that after the pipe is installed to grade and line, there remains a
4 -inch minimum depth of material below the pipe barrel and a minimum of 3- inches below
the bell. For pipe sizes 66- inches and larger, the minimum depth of material below the
pipe barrel sholl be 6- inches. Bedding, hounching and initial bockfill sholl be compacted to
6 -inch maximum lifts to not less than 95% Standard Proctor Density for the entire depth of
the material placed. The bockfill shall be brought up evenly on both sides of the pipe for
the full length of the pipe. Hunching shall extend to the springline of the pipe. The limit of
initial backfill shall be 6- inches above the springline. Minimum trench width shall be the
outside diameter of the pipe plus 18- inches. Final bockfill for all RCP installations under and
within 5 -feet of pavement sholl be B- Borrow for Structure Bockfill meeting the material
requirements of the INDOT and sholl be compacted in 6 -inch maximum lifts to not less
than 95% Standard Proctor Density for the entire depth of the material placed. The bockfill
for the top 6- inches of the excavation below the start of the aggregate sub -base of the
pavement sholl be No. 53 Stone meeting the materials requirements of the INDOT and sholl
be compacted to not less than 95% Standard Proctor Density. Final Bockfill for all RCP
installations greater than 5 -feet of pavement shall be clean fill moteriol free of rocks larger
than 6- inches in diameter, frozen lumps of soil, wood or other extraneous material,
compacted in 12 -inch maximum lifts to not less than 90% Standard Proctor Density for the
entire depth of the excavation.
4. All paving within the existing and proposed city right -of -woy sholl conform to the
requirements of the Deportment of Engineering. Contractor shall contact the Deportment of
Engineering to schedule o pre - construction meeting to review these construction
requirements, staff notification, required staged inspections, and to review the authority of
the Department as it relates to the work in the existing and proposed city right -of -woy.
CITY OF CARAIEUCLAY TOWNMUP
Dept. of CommuniD+ Senices -- Building & Code Serrices `
One Civic Square I' Flaor; Carmel, IN 46032
PLANA UTRENTI-CA TION CERTOTCA TIONSAND AGREEMENT
As the authorized agent responsible for obtaisant, a pepuft or pttrttfis?, i certify thAt these plans;are"
IDENTICAL to those released for construction by the Indiana Dept._ofIrut & Anildittg services. I also°
understand 4t if it is determined that these plans are not identical,li S i'OP WORK Chit t will be
served r the ` ances referenced below.
Apr
Authorized Signature Printed Name
'Required under Chapter 7; Section 10 the Carmel City Code, entitled "building Code "and Sec>±on 39:4 =F d=id on
29.4.3 entitled "Administration ". Required by Carmel / Clay Township Z0b tg Ordinance: Section "31.I entitled
"Violations and Penalties ":
S:Permits /Forms / AuthentSticker 11 -01 Date
SITE NOTES
1. It is the contractor's responsibility to verify existing site conditions prior to starting work.
2. The contractor sholl be responsible for obtaining or verifying that all permits and approvals
are obtained from the respective city, county, and /or state agencies prior to starting
construction.
3. The Plumbing contractor sholl consult with the Loco[ Water Company, provide all materials
and labor, and pay all costs not borne by the Local Water Company to provide any new water
service.
4. The Plumbing contractor sholl consult with the Local Gas Company, provide all materials
and labor, and pay all costs not borne by the Local Gas Company to provide any new gas
service.
5. The Electrical Contractor shall consult with the Local Power Company, provide all materials
and labor, and pay all costs and fees not borne by the Local Power Company to provide any
new underground electrical service.
6. The Electrical Contractor shall consult with the Local Telephone Company, and shall provide
all labor and materials required which are not borne by the Telephone Company to provide any
new telephone service.
7. Underground water main extension service shall be AWWA C900 PVC or Ductile Iron.
Domestic water lateral service shall be Type 'K' Copper. (or approved equal per local water
company).
8. The incoming water service shall be installed with a minimum of 54" of cover.
9. All utility service lines shall be constructed in accordance with all the latest applicable
codes and to each utility's and /or city's standards.
10. Use composted granular fill when utility lines are placed under walks and driveways.
11. Soil borings have not been performed at this time. Pavement design is based on on
assumed soil bearing pressure of 1500 p.s.i.
12. Provide sleeves for mechanical work as required.
13. Notify Engineer at least 1 day (24 hours) prior to placing any concrete.
14. Areas between curbing, sidewalks, paving and building shall be filled with 4" of topsoil
suitable for londscoping.
15. See this sheet for exterior concrete specifications.
16. See sheet C7 for sanitary sewer lateral specifications an requirements.
17. All structures shall comply with A.D.A. 1991.
18. All edge of pavement radii are 5 feet unless otherwise noted.
19. If active utilities are encountered but not shown on the drawings, the engineer shall be
advised before work is continued.
20. Inactive and abandoned utilities encountered in excavating and grading operations shall be
reported to the engineer. They shall be removed, plugged or capped as directed by the utility
company and the engineer.
21. Contractor to install knox -box at o location determined by the fire department. Coordinate
location, type and style with Carmel Fire Department.
ASPHALT PAVEMENT SPECIFICATIONS
The paving contractor shall be responsible for the following:
1. The area to be paved sholl be cleared of all rock, debris, roots and vegetation. An approved
soil sterilant sholl be utilized to prevent the growth of weeds.
2. All soft, yielding or other unsuitable materials encountered during any phase of
subgradeconstruction shall be removed and replaced with suitable material. The replacement
material shall fill the unstable area for the entire depth of the compacted subgrade and meet
the subgrode compaction requirements. The subgrade shall be shaped to the true lines and grade
as shown on the plane.
3. The subgrade shall be compacted to 95% laboratory density as determined by ASSHTO Method
T -99.
4. The subgrode and finish paving shall be tested by on approved testing company for uniform
smoothness, density and grade.
5. Slope pavement 0.75% (MIN.) to insure proper surface drainage.
6. The hot mix asphalt based may be placed directly on the prepared subgrade in one lift for
the base course to the required compacted thickness as specified in loco] street standards.
7. The hot mix asphalt base and surface shall be placed in one lift to the true line and grades
as shown on the plans. The paving mixture sholl be placed and compacted at a temperature
between 250 F. (121 C) and 300 F, (149 C).
8. The paving mixture sholl be transported to the job site in clean well- covered trucks with
smooth dump beds. The base and surface mixtures ore to be placed with self contained, power
propelled pavers capable of placing the mix to the required dimensions as shown on the plans.
9. Asphalt grade shall be determined by its ability to satisfactory coot the aggregate, resist
rutting and remain stiff during high temperatures and sustain freeze /thaw cycles in addition to
the considerations of anticipated weather, mixing process and curing rote.
10. See details on Sheet C5 for pavement cross - sections.
11. All proposed asphalt pavement as shown shall be constructed in compliance with INDOT
standard specifications, latest edition.
12. All parking striping and ADA areas shall be marked with a durable nonshrink, white point to
be approved by the engineer.
Site Data
Zoned
EXISTING LEGEND
M -3
W
EXISTING WATER LINE
In
CURB INLET
- - -i - - -T -
UNDERGROUND TELEPHONE
■
8 "x8" AMERITECH PHONE PEDESTAL
- - - - - -
EASEMENT
parking
CINERGY ELECTRIC BOX
Handicapped parking
SETBACK LINE
_
STREET SIGN
-
CENTERLINE
D4
GAS VALVE
GAS GAS
UNDERGROUND GAS MAIN
Setback
10'
Minimum Rear Yard
Setback
20'
EXISTING CONTOUR
ICON
UNDERGROUND TELECOMMUNICATIONS -�
Parking uses @ 1/300 sq.ft.
= 18,022 sq.ft.
PROPERTY or R/W LINE �4.sx
�,>'
VEGETATION
E E
UNDERGROUND ELECTRIC LINE
Q
SANITARY MANHOLE
SANITARY SEWER
EXISTING CATCH BASIN
- _ =
EXISTING STORM SEWER
DG
EXISTING WATER VALVE
EXISTING FIRE HYDRANT
PROPOSED LEGEND
24" ROLLED CONCRETE CURB
PROPOSED SANITARY SEWER
SUBDIVISION BOUNDARY
- -
ADJOINER PROPERTY LINE
PROPOSED STORM SEWER
E E
PROPOSED UNDERGROUND ELECTRIC
Gat Wlr:
PROPOSED UNDERGROUND GAS
PROPOSED UNDERGROUND WATER
V
�-
FLOW ARROW
7767
PROPOSED GRADE
CURB INLET
CATCH BASIN
RELEASED FOR CONSTRUCTION
Subiect to compliance with all regulations
of State and Local Codes.
DEPT OF COMMUNITY SERVICES
CITY OF CARMEL / CLkY TOWNSHIP
INDIANA
N
1 /5' ALUMINUM PANEL
SCREEN PRINT 5YM50L
COLORS SELECTED BY ARCH.
HANDICAPPED SYMBOL
2' 60. ALUMINUM POST
FINISH AS PER SPECIFICATIONS
FINISH GRADE
EARTH
CONCRETE FOOTING
NOT TO SCALE
,
71
CARMEL ENGINEERING NOTES:
1. For installation of storm mains, water mains, sanitary mains, water service laterals,
sanitary service laterals under city streets, regardless of the jurisdiction of the utility, the
minimum cover from the top of the installed pavement to the top of the installed pipe sholl
be the pavement section thickness (all bituminous and aggregate material above the
subgrade) plus 1' -0 ". If the standard practice of the utility that has jurisdiction over the
installation has o more stringent cover requirement, the more stringent requirement sholl
govern.
2. Bedding, hounching and initial bockfill materials, placement and compaction for water
moins, water service laterals, sanitary mains and sanitary service laterals under and within
5 -feet of pavement shall be in accordance with the standard practice of the utility that has
jurisdiction over the installation. Final bockfill for water mains, water service laterals, sanitary
mains and sanitory service laterals under and within 5 -feet of pavement sholl be in
accordance with the standard practice of the utility that has jurisdiction over the installation.
Final bockfill for water moins, water service laterals, sanitary mains and sanitary service
laterals under and within 5 -feet of pavement shall be B- Borrow for Structure Bockfill
meeting the material requirements of the INDOT and sholl be compacted in 6 -inch maximum
lifts to not less than 95% Standard Proctor Density for the entire depth of the material
placed. The bockfill for the top 6- inches of the excavation below the start of the aggregate
sub -base of the pavement sholl be No. 53 Stone meeting the material requirements of the
INDOT and shall be compacted to not less than 95% Standard Proctor Density. If the
standard practice of the utility that has jurisdiction over the installation has o more
stringent final bockfill requirement, the more stringent requirement sholl govern.
3. Bedding, hounching, and initial bockfill for all RCP installations shall be B- Borrow for
Structure Bockfill meeting the material requirements of the INDOT. Bedding sholl be placed in
the trench bottom such that after the pipe is installed to grade and line, there remains a
4 -inch minimum depth of material below the pipe barrel and a minimum of 3- inches below
the bell. For pipe sizes 66- inches and larger, the minimum depth of material below the
pipe barrel sholl be 6- inches. Bedding, hounching and initial bockfill sholl be compacted to
6 -inch maximum lifts to not less than 95% Standard Proctor Density for the entire depth of
the material placed. The bockfill shall be brought up evenly on both sides of the pipe for
the full length of the pipe. Hunching shall extend to the springline of the pipe. The limit of
initial backfill shall be 6- inches above the springline. Minimum trench width shall be the
outside diameter of the pipe plus 18- inches. Final bockfill for all RCP installations under and
within 5 -feet of pavement sholl be B- Borrow for Structure Bockfill meeting the material
requirements of the INDOT and sholl be compacted in 6 -inch maximum lifts to not less
than 95% Standard Proctor Density for the entire depth of the material placed. The bockfill
for the top 6- inches of the excavation below the start of the aggregate sub -base of the
pavement sholl be No. 53 Stone meeting the materials requirements of the INDOT and sholl
be compacted to not less than 95% Standard Proctor Density. Final Bockfill for all RCP
installations greater than 5 -feet of pavement shall be clean fill moteriol free of rocks larger
than 6- inches in diameter, frozen lumps of soil, wood or other extraneous material,
compacted in 12 -inch maximum lifts to not less than 90% Standard Proctor Density for the
entire depth of the excavation.
4. All paving within the existing and proposed city right -of -woy sholl conform to the
requirements of the Deportment of Engineering. Contractor shall contact the Deportment of
Engineering to schedule o pre - construction meeting to review these construction
requirements, staff notification, required staged inspections, and to review the authority of
the Department as it relates to the work in the existing and proposed city right -of -woy.
CITY OF CARAIEUCLAY TOWNMUP
Dept. of CommuniD+ Senices -- Building & Code Serrices `
One Civic Square I' Flaor; Carmel, IN 46032
PLANA UTRENTI-CA TION CERTOTCA TIONSAND AGREEMENT
As the authorized agent responsible for obtaisant, a pepuft or pttrttfis?, i certify thAt these plans;are"
IDENTICAL to those released for construction by the Indiana Dept._ofIrut & Anildittg services. I also°
understand 4t if it is determined that these plans are not identical,li S i'OP WORK Chit t will be
served r the ` ances referenced below.
Apr
Authorized Signature Printed Name
'Required under Chapter 7; Section 10 the Carmel City Code, entitled "building Code "and Sec>±on 39:4 =F d=id on
29.4.3 entitled "Administration ". Required by Carmel / Clay Township Z0b tg Ordinance: Section "31.I entitled
"Violations and Penalties ":
S:Permits /Forms / AuthentSticker 11 -01 Date
SITE NOTES
1. It is the contractor's responsibility to verify existing site conditions prior to starting work.
2. The contractor sholl be responsible for obtaining or verifying that all permits and approvals
are obtained from the respective city, county, and /or state agencies prior to starting
construction.
3. The Plumbing contractor sholl consult with the Loco[ Water Company, provide all materials
and labor, and pay all costs not borne by the Local Water Company to provide any new water
service.
4. The Plumbing contractor sholl consult with the Local Gas Company, provide all materials
and labor, and pay all costs not borne by the Local Gas Company to provide any new gas
service.
5. The Electrical Contractor shall consult with the Local Power Company, provide all materials
and labor, and pay all costs and fees not borne by the Local Power Company to provide any
new underground electrical service.
6. The Electrical Contractor shall consult with the Local Telephone Company, and shall provide
all labor and materials required which are not borne by the Telephone Company to provide any
new telephone service.
7. Underground water main extension service shall be AWWA C900 PVC or Ductile Iron.
Domestic water lateral service shall be Type 'K' Copper. (or approved equal per local water
company).
8. The incoming water service shall be installed with a minimum of 54" of cover.
9. All utility service lines shall be constructed in accordance with all the latest applicable
codes and to each utility's and /or city's standards.
10. Use composted granular fill when utility lines are placed under walks and driveways.
11. Soil borings have not been performed at this time. Pavement design is based on on
assumed soil bearing pressure of 1500 p.s.i.
12. Provide sleeves for mechanical work as required.
13. Notify Engineer at least 1 day (24 hours) prior to placing any concrete.
14. Areas between curbing, sidewalks, paving and building shall be filled with 4" of topsoil
suitable for londscoping.
15. See this sheet for exterior concrete specifications.
16. See sheet C7 for sanitary sewer lateral specifications an requirements.
17. All structures shall comply with A.D.A. 1991.
18. All edge of pavement radii are 5 feet unless otherwise noted.
19. If active utilities are encountered but not shown on the drawings, the engineer shall be
advised before work is continued.
20. Inactive and abandoned utilities encountered in excavating and grading operations shall be
reported to the engineer. They shall be removed, plugged or capped as directed by the utility
company and the engineer.
21. Contractor to install knox -box at o location determined by the fire department. Coordinate
location, type and style with Carmel Fire Department.
ASPHALT PAVEMENT SPECIFICATIONS
The paving contractor shall be responsible for the following:
1. The area to be paved sholl be cleared of all rock, debris, roots and vegetation. An approved
soil sterilant sholl be utilized to prevent the growth of weeds.
2. All soft, yielding or other unsuitable materials encountered during any phase of
subgradeconstruction shall be removed and replaced with suitable material. The replacement
material shall fill the unstable area for the entire depth of the compacted subgrade and meet
the subgrode compaction requirements. The subgrade shall be shaped to the true lines and grade
as shown on the plane.
3. The subgrade shall be compacted to 95% laboratory density as determined by ASSHTO Method
T -99.
4. The subgrode and finish paving shall be tested by on approved testing company for uniform
smoothness, density and grade.
5. Slope pavement 0.75% (MIN.) to insure proper surface drainage.
6. The hot mix asphalt based may be placed directly on the prepared subgrade in one lift for
the base course to the required compacted thickness as specified in loco] street standards.
7. The hot mix asphalt base and surface shall be placed in one lift to the true line and grades
as shown on the plans. The paving mixture sholl be placed and compacted at a temperature
between 250 F. (121 C) and 300 F, (149 C).
8. The paving mixture sholl be transported to the job site in clean well- covered trucks with
smooth dump beds. The base and surface mixtures ore to be placed with self contained, power
propelled pavers capable of placing the mix to the required dimensions as shown on the plans.
9. Asphalt grade shall be determined by its ability to satisfactory coot the aggregate, resist
rutting and remain stiff during high temperatures and sustain freeze /thaw cycles in addition to
the considerations of anticipated weather, mixing process and curing rote.
10. See details on Sheet C5 for pavement cross - sections.
11. All proposed asphalt pavement as shown shall be constructed in compliance with INDOT
standard specifications, latest edition.
12. All parking striping and ADA areas shall be marked with a durable nonshrink, white point to
be approved by the engineer.
Site Data
Zoned
DATE
M -3
Lot area
g -30 -05
2.636 Ac. +/-
Building Area
STRUCTION
30,722 sq.ft.
Impervious Area
CPW
69.4%
Customer /Employee
parking
119
Handicapped parking
4 +1 (on Existing Parking)
Proposed parking
124
Minimum Front Yard
Setback
20'
Minimum Side Yard
Setback
10'
Minimum Rear Yard
Setback
20'
Retail parking uses
@ 1/200
sq.ft. = 12,700 sq.ft. (max)
Parking uses @ 1/300 sq.ft.
= 18,022 sq.ft.
PROPOSED SITE PLAN
GRAPHIC SCALE
40 0 20 40 so
0
TC*-4%
�0
�PQ
( IN FEET )
1 inch = 40 ft.
/FEB - 6 2008
r/,03" z -,
%o2-) /-te r✓ cSl=. 7 /v%
0- V- /- _7�;J C_
,,2- a
W�
160
-�w *�� ,iii✓
Vii,` " % /r.• ,r- %. °�;k .
/``. ��, : ,iii,'„:✓ % :, ,.
V1
W
E Al
r 0) E
r
U) 3
M
v
X O
Q) < c
u J
W q' w
1
W � o
N
Ol 0 M
Lo
�I CQ i
ELI W in _
Q
Q
W Moo
t,,,l Q Z
z
Ld
ED � Q J
W ELM
tD
V �coU
m
I-
U N o
LJ
LLJ ,.
-Z oWWe Z
in
Z in
UQ0J
J �La
to e
Qdnv
COD
WwO
d CO
V1,
Zd
cc z
iJ]
d
2 °z
O O
d
CQ
d
� A
�z
Z
V
01
C9
O
m
X �
� d
�z
lit �.
?� A
az
V W
E-
�3 U
Z w
U
Q z
W
CL
W
_W a
0 N D
W x d
U CD
CQ
O PQ I-
O C) C6
E O
CSI
r-
PROJ. No. 050ro -030
DATE
1-22 -05
g -30 -05
I Wc.
NEERNG
11 - 30 - 05
STRUCTION
I - 08 - 0-1
DRAWN BY:
CPW
CHEC!(ED BY:
ALD
SHEET :
1
- C