HomeMy WebLinkAboutM-7IR- COOLED ONDENSING UNIT QUID SUCT'ON 3X36 OUTDOOR i R � OUVER BY ill-DING MANUFACTURER M E C H A N I C A L R 0 0 M P L A N 20"X 20" OPPOSED BLADE' PROPORTIONING DAMPER BY T. C. C. �— 20" X 20" I FIRE DAMPER GATE VALVE (TYPICAL) '6X6 1" DRAIN TERMINATE OVER F. D. SECONDARY HEATING CI NG PUMP E -1 & E 2 �� CIRCUIT SETTER 1 1/2" S 1 1/2" S&P TO HEATING SYSTEM 1 1/2" R �- 20" X 20" FLEXIBLE CONNECTION FAN SECTION 7 FILTER SECTION 32X12 20" X 20" X 62" WIDE 2 HOT AND COLD PLENUMS M -3 FLEXIBLE CONNECTION HEATING f COIL I` Q OPPOSED BLADE PROPORTIONING i DAMPERS BY T. C. C. > FLEXIBLE CONNECTION COOLING COIL Z-7 4" CONCRETE PAD 6 LVIBRAT'ON M -3 !SO;- A"ORS SECTION A SCALE: 1 /4"= 1"0" l\L �' PRESSURE GAUGE (TYPICAL) 1 1/2" =FLEXIBLE CONNECTION > (TYPICAL) 1" CW INITIAL FILLING MAKE -UP L > WATER - - - -- TRIPLE DUTY VALVE (TYPICAL) 3 WAY TEMPERATURE CONTROL VALVE 1 112" FIRE DAMPER AT EACH FLOOR PENETRATION CHECK VALVE r BALANCING VALVE (TYPICAL) CIRCUIT SETTER 8" S &R BRIDGE F / THERMOMETER (i (TYPICAL 1 / 2 I' 8" S &R FROM CENTRAL BOILER FACILITY TYPICAL SECONDARY HEATING PIPING DIAGRAM NGT TO SL A,_ - G M E C H A N I C A L R 0 0 F P L A N SCALE: 1/16" = 1' -0" 1 -4 E -105 320 6X12 1 -5 E -111 360 6X12 1 -6 E -103 460 6X12 w 0 A I R HANDLING UN I T #E - 1 ZONE DAMPER SCHEDULE N0. AREA SERVED C.F.M. DAMPER SIZE 1 -1 E -107 1590 18X12 1 -2 E- 102,E- 110,E -112 520 GX12 1 -3 E -104 405 6X12 1 -4 E -105 320 6X12 1 -5 E -111 360 6X12 1 -6 E -103 460 6X12 PLAN NOTES: 0 SEE SHEET M -2 FOR GENERAL NOTES, LEGEND AND SCHEDULES. O ALL WORK SHOWN ON THIS SHEET IS BY MECHANICAL TRADES UNLESS OTHERWISE NOTED. O TEMPERATURE CONTROL AIR COMPRESSOR AND AFTERCOOLER: BY TEMPERATURE CONTROL CONTRACTOR, 80 GALLON CAPACITY, DUPLEX ( 2 ) MOTOR 2 HP, 460 VOLTS, 3 PHASE, 60 HERTZ. AFTERCOOLER MOTOR: !/5 HP, 115 VOLTS, 1 PHASE, 60 HERTZ. OINSTALL FIRE DAMPER AT EACH MEZZANINE FLOOR PENETRATION. U N I T E Lo M E C H A N I C A L M E Z Z A N I N E F L 0 0 R P L A N SCALE: 1/8" = 1' -0" v ° w 0- co (Lo 0:� 18" X 18" DEEP T AIR PLENUM 8 EXHAUST LOUVER LDING MFGR. SEE ENLARGED MECHANICAL ROOM PLAN THIS SHEET -- - - - - - - - - - - - - - - - - - - - - - - - I I I I I I I I I I I I I . I 6 -14 -85 ISSUE FOR BID PACKAGE JWR REV. DATE ISSUE /REVISION RECORD APPROVED N N 0 v Z 3 �- C= w U W v . W W W W > ~_ Z C _ C.7 Z U Z Q Cl-- W Z Q V J O CL ILZ Q Z a 13 z Q z w LJ 1.0 NL Q V X 13 CL LLJ X 0 V or_ W 0 LL Q 0 W a W H V Q V _ Q D LL LLJ Lu V) F— 0 O = Z LLI Ei> ��w�u11I Irrur�,,� ` o M o Q y� cc� =N r p= Q Ln /7 .pSp� H— p Lo ° C-) f1- o0 W Lu W i (n a CC v ° w 0- co (Lo 0:� N0. M-7 01 1