HomeMy WebLinkAbout05050040.12GENERAL NOTES:
A. ALL DIMENSIONS ARE FROM FACE OF STUD, OR FACE OF PRECAST
PANEL, OR FACE OF C.M.U. ANY DIMENSIONS NOT SHOWN OR DEEMED
QUESTIONABLE ARE TO BE VERIFIED BY ARCHITECT /DESIGNER.
DO NOT SCALE DRAWINGS.
B. PROVIDE WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE
MOUNTED ITEMS.
C. COORDINATE WORK OF THIS TRADE WITH OTHER TRADES.
D. DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE
MORE THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED
(I.E. 100A). SEE DIVISION 500 DRAWINGS FOR DOOR SCHEDULE.
E. PROVIDE MISCELLANEOUS METAL SUPPORT FOR ALL CEILING
SUSPENDED ITEMS.
F. APPLY SEALANT AT ALL JUNCTURES BETWEEN DIFFERENT MATERIALS (I.E.
STOREFRONT AND PRECAST).
G. APPLY SEALANT AT ALL PLUMBING FIXTURES AT JUNCTURE WITH WALL.
H. APPLY SEALANT AT ALL COUNTERTOPS AND BACK SPLASHES AT JUNCTURE
WITH WALL.
I. ALL STEEL STUDS ARE TO BE BRACED ACCORDING TO MANUFACTURER'S
A J SEE SECTION I DRAWINGS FOR FINISH PLANS AND SPECIFICATIONS.
K. ALL INTERIOR WALLS SHALL BE MARKED IN PLACE PRIOR TO FRAMING
FOR ARCHITECT /DESIGNER TO REVIEW.
1 L. ALL DOORS MUST BE INSTALLED WITH AT LEAST THE MINIMUM
MANEUVERING CLEARANCE AT THE DOOR APPROACH PER THE MOST
A402 CURRENT AMERICANS WITH DISABILITIES ACT.
(D 1.7 2 3 4 5 PLAN NOTES
2 150'-1 Y"
A201 t' -:�' '� 24'- 103/4" '-4Ya" 40' -0" O1 ALIGN FINISH FACES.
40' -0" 34' -0" 2 TANDARD R 0 DRAIN LOCATION (4' -0" FROM FACE OF PARAPET)
t A I I 3' -0" WIDE OVERFLOW SCUPPER LOCATION. SEE DETIAL 5/A201
15 AREA "A" AREA "B" 4O ROOF HATCH ABOVE 2' -6" x S -0 ". SEE STRUCTURAL DRAWINGS FOR
�- 10 PROPOSED FUTURE EXACT LOCATION (SEE 2/A102).
U5 VERTICAL LADDER W/ 1/2 "x2 1/2" FLAT BAR RAILS 18" APART W/ 3/4 "0
I 1 NON -SLIP RUNGS AT 12 O.C. AT LEAST 7 CLEAR FROM THE WALL.
� A401 4' -4�" ANCHOR WITH 1/2 "x2 1/2" L- SHAPED FALT BAR AT 5' -0" O.C. MAXIMUM.
3' -4�" V-6
" 6 HIGHWAY GUARDRAIL ON CONCRETE CURB. SEE DETAIL 1/A402.
Y 3 SLOP 3' -4%" 33' -fil'"
N 6
t5 t5 � O7 ROOF DRAIN LEADER LOCATION
-0. o
® 3 1/2" HIGH x 4" WIDE CONCRETE CURB (POUR AGAINST WALLS).
l H = -
WATER ' Q9 ROOF TOP MECHANICAL UNIT OR EXHAUST FAN LOCATION ON CURB. SEE
G.9 7 ROOM MECHANICAL DRAWINGS FOR ADDITIONAL INFORMAITON
0
_ to CONCRETE RETAINING WALL LOCATION W /STEEL GUARDRAIL. SEE DETAIL
1/A402 AND STRUCTURAL FOR ADDITIONAL INFORMATION
t 1 CONTINUOUS 4" SOFFIT VENT
12 24" x 24" PAINTED STEEL CEILING ACCESS HATCH
t3 24" WIDE RUBBER ROOF PAD WALKWAY. COORDINATE EXTENT AND EXACT
3 LOCATION IN FIELD TO PROVIDE ACCESS TO SERVICE SIDE OF ALL RTU'S.
A201 14 DOOR CONTRACTOR TO PROVIDE HANDRAILS PER SPECIFICATIONS.
15 6 "_ DIAMETER STEEL PIPE BOLLARD. _ SEE DETAIL 9/A403.
AREA 'A' FLOOR PLAN
SCALE: 1/1 61$=1 1-011
NORTH
;n
RE
-'W
uke
600 East 96th Street
Suite 100
Indianapolis, IN 46240
Phone: 317 808 -6000
Fax: (317 ) 808 -6797
CSO
Architecture
Engineering
Interiors
Landscape Architecture
Land Surveying
Corporate Office
280 East 96th Street, Suite 200
Indianapolis, Indiana 46240
317.848.7800
FAX 317.574.0957 ®CoDYright 2002
Ln
0
0
o u')
o
ai
U-) CD o
ao z
Q I
= M
� V �
I LLJ Y
c LO a
o CL
0
° a m
�aaa
o
ilA
o�
V)
O
a
o
W
Z
J
Z
W
0
a
o
LL Q
Z
J
U O
g0:�
a
CL zQ
Lj—
a
W
Y �Q
=o
< ? z
O
O
�
�
J
Q
W = J
Lj
LL
//y�►/ ry L
w
a
J
Q O
U Z (aj
w
W
I-- L0
Q
W
wo
cc
3:O
Q
a
v
0)
W
3:
Certified B
o��aa
= No. �
*AR00910036
STATE OF rj
'•� Ip NP•''.� i•�
4i ••.., DIA„ .•• p
IT
Drawing Number:
A103
Of Sheets
Duke Job Number:
X
A/E Job Number:
23137