Loading...
HomeMy WebLinkAbout05050040.12GENERAL NOTES: A. ALL DIMENSIONS ARE FROM FACE OF STUD, OR FACE OF PRECAST PANEL, OR FACE OF C.M.U. ANY DIMENSIONS NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY ARCHITECT /DESIGNER. DO NOT SCALE DRAWINGS. B. PROVIDE WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. C. COORDINATE WORK OF THIS TRADE WITH OTHER TRADES. D. DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (I.E. 100A). SEE DIVISION 500 DRAWINGS FOR DOOR SCHEDULE. E. PROVIDE MISCELLANEOUS METAL SUPPORT FOR ALL CEILING SUSPENDED ITEMS. F. APPLY SEALANT AT ALL JUNCTURES BETWEEN DIFFERENT MATERIALS (I.E. STOREFRONT AND PRECAST). G. APPLY SEALANT AT ALL PLUMBING FIXTURES AT JUNCTURE WITH WALL. H. APPLY SEALANT AT ALL COUNTERTOPS AND BACK SPLASHES AT JUNCTURE WITH WALL. I. ALL STEEL STUDS ARE TO BE BRACED ACCORDING TO MANUFACTURER'S A J SEE SECTION I DRAWINGS FOR FINISH PLANS AND SPECIFICATIONS. K. ALL INTERIOR WALLS SHALL BE MARKED IN PLACE PRIOR TO FRAMING FOR ARCHITECT /DESIGNER TO REVIEW. 1 L. ALL DOORS MUST BE INSTALLED WITH AT LEAST THE MINIMUM MANEUVERING CLEARANCE AT THE DOOR APPROACH PER THE MOST A402 CURRENT AMERICANS WITH DISABILITIES ACT. (D 1.7 2 3 4 5 PLAN NOTES 2 150'-1 Y" A201 t' -:�' '� 24'- 103/4" '-4Ya" 40' -0" O1 ALIGN FINISH FACES. 40' -0" 34' -0" 2 TANDARD R 0 DRAIN LOCATION (4' -0" FROM FACE OF PARAPET) t A I I 3' -0" WIDE OVERFLOW SCUPPER LOCATION. SEE DETIAL 5/A201 15 AREA "A" AREA "B" 4O ROOF HATCH ABOVE 2' -6" x S -0 ". SEE STRUCTURAL DRAWINGS FOR �- 10 PROPOSED FUTURE EXACT LOCATION (SEE 2/A102). U5 VERTICAL LADDER W/ 1/2 "x2 1/2" FLAT BAR RAILS 18" APART W/ 3/4 "0 I 1 NON -SLIP RUNGS AT 12 O.C. AT LEAST 7 CLEAR FROM THE WALL. � A401 4' -4�" ANCHOR WITH 1/2 "x2 1/2" L- SHAPED FALT BAR AT 5' -0" O.C. MAXIMUM. 3' -4�" V-6 " 6 HIGHWAY GUARDRAIL ON CONCRETE CURB. SEE DETAIL 1/A402. Y 3 SLOP 3' -4%" 33' -fil'" N 6 t5 t5 � O7 ROOF DRAIN LEADER LOCATION -0. o ® 3 1/2" HIGH x 4" WIDE CONCRETE CURB (POUR AGAINST WALLS). l H = - WATER ' Q9 ROOF TOP MECHANICAL UNIT OR EXHAUST FAN LOCATION ON CURB. SEE G.9 7 ROOM MECHANICAL DRAWINGS FOR ADDITIONAL INFORMAITON 0 _ to CONCRETE RETAINING WALL LOCATION W /STEEL GUARDRAIL. SEE DETAIL 1/A402 AND STRUCTURAL FOR ADDITIONAL INFORMATION t 1 CONTINUOUS 4" SOFFIT VENT 12 24" x 24" PAINTED STEEL CEILING ACCESS HATCH t3 24" WIDE RUBBER ROOF PAD WALKWAY. COORDINATE EXTENT AND EXACT 3 LOCATION IN FIELD TO PROVIDE ACCESS TO SERVICE SIDE OF ALL RTU'S. A201 14 DOOR CONTRACTOR TO PROVIDE HANDRAILS PER SPECIFICATIONS. 15 6 "_ DIAMETER STEEL PIPE BOLLARD. _ SEE DETAIL 9/A403. AREA 'A' FLOOR PLAN SCALE: 1/1 61$=1 1-011 NORTH ;n RE -'W uke 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808 -6000 Fax: (317 ) 808 -6797 CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®CoDYright 2002 Ln 0 0 o u') o ai U-) CD o ao z Q I = M � V � I LLJ Y c LO a o CL 0 ° a m �aaa o ilA o� V) O a o W Z J Z W 0 a o LL Q Z J U O g0:� a CL zQ Lj— a W Y �Q =o < ? z O O � � J Q W = J Lj LL //y�►/ ry L w a J Q O U Z (aj w W I-- L0 Q W wo cc 3:O Q a v 0) W 3: Certified B o��aa = No. � *AR00910036 STATE OF rj '•� Ip NP•''.� i•� 4i ••.., DIA„ .•• p IT Drawing Number: A103 Of Sheets Duke Job Number: X A/E Job Number: 23137