HomeMy WebLinkAbout05050040.54 ANCI
- BP1
M
U
J
LL_
w
1
N
LL_
6
E
0
z
rn
3
0
rn
0
0
IR
00
0
LO
0
00
0
0
0
3
0
N
v_
I
0
N
O
LO
0
LO
0
0
N
z
w
U
0
0
1) -AB1
" x 16" x 1' -4"
ASE PLATE
38x8
OLUMN
OVERSIZED WASHER
(BP1A ONLY)
I I
I
^I �
i
•
o
I
•
TOP OF PIER
AND WALL
AT 99' -4"
1,10.
1' -0� >
2
PIER P2
DETAIL
B
a
i
Hie_ �E
(6) - #8 VERTICAL
#4 TIES @ 12 "O.C.
+ 3 TIES AT 3" O.C.
AT TOP OF PIER
2' -6" 3' -6"
6' -0"
DETAIL D
1/4" = 1' -0" F1.0
0
1
2
3
4
1' 4°
�) -A131
" x 18" x 1'-0"
ASE PLATE
s8x8
OLUMN
BASE PLATE BP2
0
I
`J �O
0
I
5
3' -0" 2 4' -0"
7' -0"
0
1' -0"
2„ 4„ 4" 2„
(4) -AB1
N
f- 4" x 12" x 1' -4"
BASE PLATE
� TS8x8
COLUMN
N OVERSIZED WASHER
(BP3A ONLY)
4 ANCHOR BOLTS
5/16 (BP3A ONLY)
BASE PLATE BP3 & BP3A
I I
B I i
SEE FOUNDATION S5.0 i
PLANS FOR TOP
AND BOTTOM
ELEVATIONS OF o
FOOTING a
iii bi a
3" CLR. (TYP.)
SEE FOOTING SCHEDULE ON DRAWING
F1.1 FOR FOOTING INFORMATION
5 ANCH
STEEL COLUMN PER
FOUNDATION PLAN
9
D ETAI L G TYPICAL STEEL COLUMN AT INTERIOR FOOTING
1/4" = 1' -0" F1.0 NO SCALE
SAWED JOINT 1/8" x 1/2" DEEP
F- 4" DIA. RODS (SMOOTH) x 16" LONG SPACED
AT 24 ". GREASE HALF OF EACH ROD.
SLAB ON GRADE
r- 4
° z
_ �Q
J
w CL
a-
ooh
SEE NOTE 2'o0O °O
6 COMPACTED (95 PERCENT MAXIMUM DRY
DENSITY) FREE DRAINING GRANULAR MATERIAL.
NOTES:
1. LOCATE CONSTRUCTION JOINTS AT CONTROL JOINT LOCATIONS.
2. APPLY LIQUID BOND BREAKER TO FULL DEPTH OF CONSTRUCTION JOINT.
TYPICAL SLAB ON GRADE CONSTRUCTION JOINT
NO SCALE
FOUNDA11ONS
1. PREPARE AREAS OF THE SITE SUPPORTING STRUCTURE BY REMOVING TOPSOIL, EXISTING FILL,
ORGANIC MATERIAL, OR FROZEN, WET, SOFT, LOOSE OR OTHERWISE UNSUITABLE MATERIALS.
2. PROOF ROLL THE EXPOSED SUBGRADE WITH A MEDIUM - WEIGHT ROLLER TO DETERMINE IF ANY
POCKETS OF SOFT, UNSUITABLE MATERIAL EXIST BENEATH THE EXPOSED SUBGRADE. REMOVE
ANY UNSUITABLE MATERIAL ENCOUNTERED AND REPLACE WITH A WELL COMPACTED
GRANULAR MATERIAL.
3. PLACEMENT AND COMPACTION OF ENGINEERED FILL SHALL BE OVERSEEN BY THE TESTING
LABORATORY. PLACE FILL MATERIAL IN LAYERS NOT EXCEEDING 8 INCHES IN LOOSE
THICKNESS. MECHANICALLY COMPACT EACH LAYER TO AT LEAST THE REQUIRED MINIMUM
DRY DENSITY.
4. FOOTINGS NOT SUPPORTED BY ENGINEERED FILL SHOULD BEAR ON FIRM, UNDISTURBED
MATERIAL. IF UNSUITABLE MATERIAL IS ENCOUNTERED, REESTABLISH THE BEARING ELEVATION
OF THE FOOTING BY LOCALIZED UNDERCUTTING, AND FILLING WITH SUITABLE GRANULAR
MATERIAL OR CONCRETE AS RECOMMENDED BY THE TESTING LABORATORY. SOILS TESTING
FIRM SHALL VERIFY BEARING CAPACITY OF SOIL AT ALL COLUMN FOOTINGS AND AT 8' -0"
INCREMENTS ALONG WALL FOOTINGS, ALLOWABLE BEARING PRESSURE SHALL BE 2500 PSF
FOR COLUMN FOOTINGS AND 2000 PSF FOR WALL FOOTINGS.
5. PLACE FOOTINGS THE SAME DAY EXCAVATIONS ARE OPENED. IF THIS IS NOT POSSIBLE,
ADEQUATELY PROTECT THE EXPOSED MATERIAL IN THE BASES OF THE FOOTING EXCAVATIONS
FROM ANY DETRIMENTAL CHANGE IN CONDITION SUCH AS FROM DISTURBANCE, RAIN OR
FREEZING. SURFACE RUNOFF SHALL NOT BE ALLOWED TO ENTER THE EXCAVATIONS.
6. CONCRETE WALLS RETAINING EARTH MUST HAVE REACHED 100 PERCENT OF THEIR REQUIRED
28 DAY COMPRESSIVE STRENGTH BEFORE BACKFILLING OPERATIONS BEGIN.
7. BACKFILL EACH SIDE OF CONCRETE WALLS, WITH EARTH ON BOTH SIDES, SIMULTANEOUSLY.
8. BACKFILL PLACED AGAINST CONCRETE WALLS SHALL BE A WELL- GRADED GRANULAR
MATERIAL.
9. FOR INFORMATION REGARDING SUBSURFACE CONDITIONS, REFER TO PRELIMINARY SUBSURFACE
INVESTIGATION & FOUNDATION RECOMMENDATIONS, PREPARED BY ALT & WITZIG ENGINEERING,
INC., DATED MAY 6, 2002. ALT & WITZIG PROJECT NUMBER 021NO312.
VERSIZED WASHER
x 18" x V-3"
\SE PLATE
8x8
)LUMN
BASE PLATE BP4
�o
o �
d v
w w
o
a'
a
d �
z
w
0
w
m
Uj
w
4"
HEAVY HEX NUTS
AND WASHERS
TOP OF CONCRETE
FOOTING
1" 0 BOLT (A36)
ANCHOR BOLT DETAIL AB1
SEE DRAWING F1.1
FOR COLUMN AND BASE
PLATE INFORMATION-
PROJECTION PER
ANCHOR BOLT DETAILS
ON DRAWING F2.1
i FINISHED COLUMN END
IN
LEVEL G NUT I
( TYPICAL }
2" NON- SHRINK GROUT
�=. �= -A36 ANCHOR BOLTS WITH DOUBLE NUTS
TOP OF CONCRETE AND WASHERS FOR LEVELING. SEE ANCHOR
FOOTING BOLT DETAILS ON DRAWING F2.1 FOR
I
ADDITIONAL INFORMATION. CLEAN OIL FROM
ANCHOR BOLTS BEFORE INSTALLATION.
REINFORCING STEEL
1. PROVIDE MINIMUM CONCRETE COVER FOR REINFORCING STEEL IN ACCORDANCE WITH THE ACI
"BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" (ACI 318 -95), UNLESS
OTHERWISE INDICATED.
2. REINFORCING STEEL SHALL BE SUPPORTED AND SECURED AGAINST DISPLACEMENT IN
ACCORDANCE WITH THE CONCRETE REINFORCING STEEL INSTITUTE'S "MANUAL OF STANDARD
PRACTICE ".
3. DETAILS OF REINFORCING STEEL FABRICATION AND PLACEMENT SHALL CONFORM TO ACI
"DETAILS AND DETAILING OF CONCRETE REINFORCEMENT" (ACI 315) AND "MANUAL OF
ENGINEERING AND PLACING DRAWINGS FOR REINFORCED CONCRETE STRUCTURES" (ACI 315R)
UNLESS OTHERWISE INDICATED.
4. REINFORCING STEEL BENDS, HOOKS AND LAP SPLICES SHALL CONFORM TO THE ACI "BUILDING
CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" (ACI 318 -95) UNLESS OTHERWISE
INDICATED.
5. PROVIDE STANDEES FOR THE SUPPORT OF TOP REINFORCEMENT FOR FOOTINGS.
6. PROVIDE PLASTIC, SNAP -ON SPACE WHEELS TO MAINTAIN REQUIRED CONCRETE COVER FOR
VERTICAL WALL REINFORCEMENT.
7. INSTALL DOWELS IN THE FOOTING FORMS BEFORE CONCRETE IS PLACED, SUPPORTING AND
TYING THEM SECURELY IN POSITION. DO NOT STICK DOWELS INTO FOOTINGS AFTER
CONCRETE IS PLACED.
8. POSITION DOWELS FOR VERTICAL WALL REINFORCEMENT IN COLUMN FOOTINGS, PILE CAPS AND
WALL FOOTING STEPS WITH 6 INCHES MAXIMUM BOTTOM COVER.
9. FIELD BENDING OF REINFORCING STEEL IS PROHIBITED.
TYPICAL COLUMN BASE B
NO SCALE
BLE
TECH H)
x 4' -0"
ER
TYPICAL COLUMN ISOLATION JOINTS
NO SCALE
CONCRETE
1. THE MIXING, HANDLING, PLACING AND CURING OF CONCRETE SHALL BE IN ACCORDANCE WITH
THE ACI "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" (ACI 318 -95).
2. FINISHING OF SLABS: AFTER SCREEDING, BULL FLOATING AND FLOATING OPERATIONS HAVE
BEEN COMPLETED, APPLY FINAL FINISH AS INDICATED BELOW.
a. FLOOR SLABS - . . . - HARD TROWEL FINISH
b. SLIP RESISTANT SURFACES _ . . . . . . . . . . _ BROOM FINISH
3. CURING OF SLABS: CURE SLABS WITH CURING COMPOUNDS OR MOISTURE RETENTION COVERS.
4. SUMBIT A MIX DESIGN FOR EACH CLASS OF CONCRETE AS INDICATED IN THE
SPECIFICATIONS.
5. THE CONCRETE MIX FOR THE FOOTINGS SHALL BE F'c = 3000 PSI .
6. THE CONCRETE MIX FOR THE INTERIOR SLABS ON GRADE SHALL HAVE THE FOLLOWING
MINIMUM REQUIREMENTS:
A. COMPRSSIVE STRENGTH Q 28 DAYS . . . . . . . . 4000 PSI
B. MINIMUM CEMENT CONTENT - . . . . . . . . . . _ 517 LB. /CU. YD.
C. MAXIMUM CEMENT RATIO _ . . . . . . . . . . _ .45
D. AIR CONTENT - . . . . . . . . . . . . . - . - 0 -37.
E. SLUMP - . . . . . . . . . . . . . . - 4 „ -6„
F. MID -RANGE WATER REDUCING ADMIXTURE
7. SLABS ON GRADE SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE ACI "GUIDE FOR
CONCRETE FLOOR AND SLAB CONSTRUCTION" ACI 302.1R (LATEST EDITION).
8. FINISH SLABS ON GRADE TO THE FOLLOWING TOLERANCES:
OVERALL VALUES: FF =25 FL =20
LOCAL VALUES: FF =20 FL =15
COORDINATION WITH OTHER TRADES
1. COORDINATE PLACEMENT OF ANCHOR BOLTS IN FOOTINGS WITH STRUCTURAL STEEL CONTRACTOR.
2. NOTIFY ENGINEER OF ANY MISPLACED OR DAMAGED ANCHOR BOLTS.
�N ^
O
0- _I -I
G.9 �N
r�
SLAB ON GRADE SOFF -CUT
CONTROL JOINT
2
3
rnn nr' PIER
4"
PIER P1
DETAIL
A
1" = 1' -0" F1.0
¢,
J o cn
Q
C)f J
w CL
CL
IF
^oo(, ID
00
LJ Rc� �oC
`- 6" COMPACTED (95 PERCENT
MAXIMUM DRY DENSITY) FREE
DRAINING GRANULAR MATERIAL.
NOTES:
1. SLAB FINISH SHALL BE HARD TROWEL.
2. ALL SLABS SHALL BE SEALED WITH ASHFORD FORMULA OR APPROVED EQUIVALENT IN
ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
TYPICAL SLAB ON GRADE CONSTRUCTION
NO SCALE
DOOR OPENING
ADDITIONAL SLAB REINFORCING AT DOORS
NO SCALE
DESIGN INFORMATION
GEOTECHNICAL
ALLOWABLE NET BEARING PRESSURE, ANBP:
COLUMN FOOTINGS-
- 2500 PSF
WALL FOOTINGS -
-2000 PSF
CONCRETE
CLASS
SEE CONCRETE SCHEDULE
AIR CONTENT
REINFORCING STEEL
REMARKS
REINFORCING BARS, AND 11ES: -
ASTM A615, GRADE 60
STRUCTURAL STEEL
o
C1
ANGLES, CHANNELS, PLATES: -
- ASTM A36
W- SHAPES -
- - - ASTM A992, GR. 50
STRUCTURAL TUBING:- - - -
- -ASTM A500, GRADE B,
�
ti
Fy = 46 KSI
ANCHOR BOLTS: -
- ASTM A36
CONNECTION BOLTS:-
- a INCH DIAMETER, ASTM A325N
4000 PSI
UNLESS OTHERWISE DETAILED ON
INTERIOR SLABS ON GRADE,
THE DRAWINGS OR APPROVED
U
BY THE ARCHITECT /ENGINEER
CONCRETE SCHEDULE
DESIGN LIVE LOADS
SLAB ON GRADE 100 PSF
ROOF LOADS:
DEAD LOAD:- - 25 PSF
UNIFORM SNOW LOAD:- - 25 PSF
DRIFTING SNOW LOAD:- -DESIGNED IN ACCORDANCE
WITH IBC 2000
DESIGN WIND LOADS
EXPOSURE B
IMPORTANCE FACTOR, I = 1.00
BASIC WIND SPEED = 90 MPH (IBC 2000 - FIGURE 1609)
CATEGORY 1
DESIGN SEISMIC LOADS
SEISMIC USE GROUP 1
SEISMIC DESIGN CATEGORY C
S DS = 0.188
S DI = 0.141
SITE CLASS D
BASIC SEISMIC FORCE
RESISTING SYSTEM = 2D
NOTES:
1. ANY CONCRETE NOT INDICATED IN THE SCHEDULE SHALL BE CLASS B.
2. INCLUDE AN AIR - ENTRAINING ADMIXTURE IN MIX DESIGNS FOR CONCRETE EXPOSED TO FREEZING AND
THAWING DURING SERVICE, AND FOR CONCRETE EXPOSED TO COLD WEATHER DURING CONSTRUCTION, BEFORE
ATTAINING ITS REQUIRED 28 DAY COMPRESSIVE STRENGTH.
AL
'O.C.
3" O.C.
ER
',W
uke
CONSTRUCTION
600 East 96th Street
Suite 100
Indianapolis, IN 46240
Phone: 317 808 -6000
Fax: 317 808 -6797
(-J' %.
28 DAY
� eta
CONCRETE
CLASS
COMPRESSIVE STRENGTH
AIR CONTENT
PLACEMENT
REMARKS
a
cn
cn
LO
0
V) N
o
C1
WATER REDUCING
A
3000 PSI
OPTIONAL
FOOTINGS & PIERS
ADMIXTURE REQUIRED
�
ti
V
T
M
m=
C'3
WATER REDUCING
B
4000 PSI
OPTIONAL
INTERIOR SLABS ON GRADE,
ADMIXTURE REQUIRED
U
TM
WATER
C
4000 PSI
6 t 1 %
EXTERIOR SLABS ON GRADE
REDUCING ADMIXTURE
Q
EXTERIOR WEARING SLABS
REQUIRED
NOTES:
1. ANY CONCRETE NOT INDICATED IN THE SCHEDULE SHALL BE CLASS B.
2. INCLUDE AN AIR - ENTRAINING ADMIXTURE IN MIX DESIGNS FOR CONCRETE EXPOSED TO FREEZING AND
THAWING DURING SERVICE, AND FOR CONCRETE EXPOSED TO COLD WEATHER DURING CONSTRUCTION, BEFORE
ATTAINING ITS REQUIRED 28 DAY COMPRESSIVE STRENGTH.
AL
'O.C.
3" O.C.
ER
',W
uke
CONSTRUCTION
600 East 96th Street
Suite 100
Indianapolis, IN 46240
Phone: 317 808 -6000
Fax: 317 808 -6797
(-J' %.
� eta
m0)
O 0
0)
OC V_
aC ®0c:
c
W
W
N
N
a
cn
cn
LO
0
V) N
o
C1
Of o
s
O
C
r
■
�
ti
V
T
M
m=
C'3
V
vi
3
U
L)
C*
5 0
o
D
U
TM
W
W
Q
a
V
Uo
�
J
w z Q
�-
0.
CIE Q
w
0
W
Quz
Z
L-Li Fz- W
Q Q
0
Z
J
W
U� 0
C
W
� O
Q
V
co
W
Certified By:
GEGF
tQ _' STE9,'%p
No. o
3::j" AR19400116:• z
: STATE OF
99�HITEG
Drawing Number:
F2 ■1
Of Sheets
Duke Job Number:
0000
A/E Job Number:
05020