Loading...
HomeMy WebLinkAbout08020085.66 0 PRINT GRAPHICS N132351 0 .sr ----------------- _ -- _ II Il ` - -- -` -- - - - - - - - - - II t I II i I I 4 EI II II � �1 ryY .I II `f= l II II II 3 I L I Y 3 +� J` II ; I I. _c _� I' 01-A 4'-L' - I J� `- - -- i ! j - - - -- - - - -- - -- - - - -- Q I i � [FiPORTANT ROOF NOTES: HANDRAIL I . I i i 1200E PLAN NOTES TO STOP ALL ROOF PITCHES TO BE B /i2 e R00 I - - - - - - OUTFACE r`F 6T FLOOR Si1Fi VA!: UX ES5 NOTED OTHERWISE SEE E:E`J'S. ; , 7 - - - - OUTFACE OF 2ND -SEE ELEV.'S FOR SLOPE SPFCifiCATfON5 _ _1 _________ .__ -; FIOUR STUD tl.4LL O= DOWNSPOUT __ - - - - - OUTFACE OF BACK PARAPET WALL ?O STOP A" FASCIA Q��-' o-- BOARD OS j 1 / I �-` -- / AS Xt c 3 -1/2" H. is PARAPET CALL Roof Plan Wall Key 8" cone. block wall 12" cone, block wall 8"X 8" C.M.U. lintel 8 "x 16" cone, block pier footing / wall - step w/ grade .-_• -- truss joist - typical span ,.. ___..... 2 "x joist -typical span perimeter footing drains :~ lam beam w/ steel post -. '11C_ lam. beam w/ solid wood bearing steel beans w/ steel post poured concrete wall, specifications by installer .2"x 4" stud wall .2"x 6" stud wall sound insulation exterior wall w/ masonry veneer All solid bearing shall be continuous from applied load to footing. No interruption by horizontal components, unless approved by Architect. Project Notes General 1. All Contractors are to verify all dimensions, per their work. 2. All Contractors are to clean up the jobsite, per their work. 3. All Contractors are to verify all applicable codes or ordinances, per their work, due to substitutions to any materials, components, or assemblies generically shown on these documents. 4. All materials, components, and assemblies shown in scale on these documents are illustrated for design purposes only, and may not be the actual size or model number used for construction. 5. Notify Architect of any conflicts, per these notes. 6. Architect shall approve any shop drawings required of this project. 7. All site planning, interior design, and kitchen -bath details are by the appropriate Subcontractor. 8. All mechanical, electrical, and plumbing (MEP) design and details are by appropriate Subcontractors. Site 1. All fill brought to the site shall achieve minimum compaction required for construction of this project, 7 `/I(, _X 3�4'WO, ItiSEP, (1sr TO L.L�- Z` a /4� WD. JhISkR g ST r0 29 21 if''_.JT&I,K JTKIN60, Stair Section "R" Value Tabulation 1. Outside air film. R -.17 2. Brick/Stone. R -39 3. 1 /2" air space. R -.97 4.1/2" exterior sheathing. R -4.0 5.31/12" batt insulation. R -13 6. 1 /2" drywall, vapor barrier. R -.40 7. Inside air film. R -.68 8. Wood siding. R -.79 9. E.F.I.S. veneer. R- 5.0 Total "R" Value = 19.61(brick/stone) 20.01(siding) = 23.25(EFIS) Note: Not all materials may be used on this project. Wall Section Key 1. Shingles over 30# felt 2.7/16" O.S.B. roof deck 3.2 "x 8" rafter @ 16" o.c., 8/12 slope 4. Metal gutter 5. Fypon Dentil #083010 over 1 "x 12 ", over 1 "x 12" w/ edge mould 6.2 "x 6" band brd. w/ 5 /4 "x 6" gutter board. 7. 1/4" cedar soffit w/ 2" cant. vent 8.1/2" drywall w/ V.B. R -.40 9.2 "x 4" kneewall 10.2 "x 6" trim framing 11.2 "x 4" studs @ 16" o.c. 12.1/2" plywood /insulation, Tyvek sheathing. R -4.0 13. 14" wood truss joist @ 16" o.c. 14.3/4" O.S.B. t/g floor deck 15.2 "x 4" Ares. trtd. sill plate w/ 1/2" anchor bolts @ 16" o.c. 16. Brick veneer w/ weep holes @ 32" o.c. R -39. Masonry ties, per code 17. 10" poured cone. wall, specs. by installer. 18.4" cone. slab over compacted gravel fill, and V.B. 19.4" pvc. perf. perimeter drain in gravel backfill. 20.8 "x 20" coat. cone. footing. 21. Moistureproofing system 22. R -13 batt insulation 23. R -38 blown insulation 24.2 "x 4" kneewall wind brace, @ 48" o.c. 25. 2 1'x 4" lath catch 26.2 "x 6" ceiling rafters @ 16" o.c. 27. Limestone water table trim course, w/ % round face 28.2 "x 4" furring. 29. Metal flashing �- 2. Final grade shall be determined by individual site conditions. 3: Slope grade away from building perimeter. 4. Coordinate masonry ledge and/ or concrete foundation walls with final grade. See "Wall Section" and "Elevations ". Framing / Structure 1. All framing to conform with practices, installation requirements, and procedures of the suppliers, and manufacturers. 2. Floor and roof trusses, laminated beams, wood columns, joists, rafters, and connectors shall to be sized and certified by the manufacturer and/ or supplier. 3. Steel beams, columns, connectors, and assemblies shall be sized and certified by the manufacturer /fabricator. 4. Floor and roof loads to be calculated per local codes and conditions. Review all construction documents and specifications to determine dead loads of materials, components, and assemblies used on this project. 5. All concrete, pre -cast or cast -in -place shall be sized and certified by the supplier /fabricator. Wall Section CV � C �C � a � r0 a p� V Z G o 41 a z � V � a Cn CO �a o U rn U �j co CS M o U C cCS p �v o �. o co CY, i o ,° cd U i tip o rn a.> . V Q ' LO 'E'-� � � c-•1 � co CO s C 00 L -5 /q 1 c' 1 CU '° () +) � S Q. O o > CO SHEET to CQ A- 5 \ 0.1 W � m � r� N � ` v � o K- Z