Loading...
HomeMy WebLinkAbout08020037.1y Sales Office Floor Plan 1/4' -1'-0' GENERAL NOTES I THE "GENERAL CONDITIONS OF TI IE CONTRACT FOR CONSTRUCTION OF A SMALL SMALL PROJECT" (A205,1993 EDITION) AS PUBLISHED BY THE AMERICAN INSTITUTE OF ARCHITECTS SHALL HEREBY BECOME PART OF THESE SPECIFICATIONS AND SHALL GOVT RN THE DUTIES, OBLIGATIONS, AND RESPONSIBILITIES OF TI IE CONTRACTOR. 2 WORK SHALL COMPLY WITH THE 2003 INDIANA BUILDING CODE AND THE LATEST EDITION OF THE INDIANA AMENDMENTS AND ALL FEDERAL, STATE AND LOCAL ORDINANCIS. 3 DO NOT SCALE DRAWINGS. ANY DESCREPANCILS ON THE CONSTRUCTION DOCUMENTS OR BETWEEN THE CONSTRUCTION DOCUMENTS AND FIELD CONDITIONS SHALL BE IMMEDIATFLY IDENTIFIED TO THE ARCHITECTS OFFICE PRIOR TO COMMENCING WORK- 4 PLAN DIMENSIONS ARE TO CENTERLINE OF WINDOWS, DOORS AND COLUMNS 5 PLAN DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD UNLESS NOTED OTHERWISE. 6 CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS OF COMPLETING THE WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS. 7 CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ACTIVITIES WITH THE OWNER PRIOR TO COMMENCING WORK 8 CONTRACTOR SHALL CARRY STATUTORY INSURANCE COVERAGE AND SHOW PROOF OF COVERAGE TO THE ARCHITECT AND OWNER- 9 CONTRACTOR SHALL WARRANTY THE WORK FOR A PERIOD OF ONE YEAR- OR AS REQUIRED BY SPECIFICATIONS OF STATE LAW, WHICHEVER IS LONGER GENERAL ELECTRICAL NOTES 1 CONTRACTOR SHALL PROVIDE DESIGN -BUILD SERVICES FOR THE NEW ELECTRICAL SYSTEM. SERVICES SHALL INCLUDE THE SIZING OF WIRING, RUNS, AND CIRCUITS; SETTING PANELS, OUTLETS & FIXTURES 2 WORK SHALL INCLUDE REVIEWING SYSTEM WITH ARCHITECT, AND THE OBTAINING OF ALL PERMITS REQUIRED FOR CONSTRUCTION. NORTH FIRE PROTECTION NOTES 1. THE CONTRACTOR SHALL PROVIDL DESIGN -BUILD SERVICES FOR THE FIRE SUPPRESSION SYSTEM. SERVICES St IALL INCLUDE THE REROUTING OF EXISTING LINES TO ACCOMMODATE NEW BUILD OUT, USING CONCEALED SPRINKLER HEADS. 2. CONTRACTOR SHALL REVIEW PROPOSED PLAN WITH ARCHITECT PRIOR TO COMMENCING WORK. 3. WORK SHALL INCLUDE THE PREPARATION OF DRAWINGS, REVIEWING SYSTEM WITH ARCHITECT, AND THE OBTAINING OF ALL PERMITS REQUIRED FOR CONSTRUCTION. GENERAL ELECTRICAL NOTES L CONTRACTOR SI IALL PROVIDE DESIGN BUILD SERVICES FOR THE NEW ELECTRICAL SYSTEM. SERVICES SHALL INCLUDE THE SIZING OF WIRING, RUNS, CIRCUITS AND SETTING PANEL, 2. WORK SI IALL INCLUDE, REVIEWING SYS ELM WITH ARCI IITECT, AND THE OBTAINING OF ALL PERMITS REQUIRED FOR CONSTRUCTION. PANEL -I 200A PANEL 120 / 208V 30 14ciND BRENWICK TND COMMLINITIES, LLC 12821 EAST NEW MARKET STREET SUITE 200 CARMEL, IN 46032 TENANT IMPROVEMENT FOR, WESTCLAY SALES OFFICE DRAWING INDEX All FLOOR PLAN A1.2 REFLECTED CEILING PLAN AND SCHEDULES A1.3 INTERIOR. ELEVATIONS AND DETAILS VICINITY MAP BUILDING DATA CARMEL, IN CODE INDIANA BUILDING CODE, 2003 EDITION OCCUPANCY OFFICE B CONSTRUCTION TYPE TYPE V -B SPRINKLED NONSEPARATED Y USES AREA FIRST FLOOR 887 SF TOTAL.: 887 SF CONSTRUCTION DOCUMENTS JANUARY 15, 2008 ARCHITECT: JOHN MOSLLE ARCHITECT 12760 HORSEFERRY ROAD SUITE 200, CARMEL, IN 46032 317- 574 -9408 WALL TYPES FIRST FLOOR PLAN NOTES ALL INTERIOR WALLS SHALL BE TYPE 1 UNLESS NOTED. 1. 5/8" GYPSUM BOARD 3 -5/8" 20 GA STEEL STUDS (& 16" O/C 5/8" GYPSUM BOARD (IF REQUIRED) 2. 5/8" GYPSUM BOARD 6" 20 GA STEEL STUDS @ 16" O/C 5/8" GYPSUM BOARD WALL SUB TYPES A. FULL THICKNESS SOUND ATTENUATION BLANKETS B. EXTEND WALLS TO DECK ABOVE PLAN LEGEND DETAIL NUMBER x SHEET NUMBER x -xxx ENLARGED PLAN/PLAN DETAIL X A -XXX x x -xxx x x -xxx ROOM 1 1 0--v DETAIL REFERENCE WALL SECTION REFERENCE INTERIOR ELEVATION EQUIPMENT RFFFRFNCL PLAN NOTE ROOM NUMBER ELEVATION MARK CEILING HEIGHT EXISTING WALL DOOR REFERENCES O NEW WALL AND DOOR IWG MAIN PANEL 12A WALL TYPE / SUB TYPE Oi WINDOW/LOUVER DESIGNATION :XISTING METERS Electrical Riser Diagram Ol . PROVIDE 4" CONCRETE SLAB W1 SYNTHETIC FIBER REINFORCING O/ 6 MIL VAPOR BARRIER O/ COMPACTED GRANULAR FILL. OPROVIDE SHELF AND ROD 3O PROVIDE 5 SHELVES 4O PROVIDE FURRING AND GYP BOARD AS TIGHT AS POSSIBLE TO CONCEAL COLUMN 5O CENTER STAIR ON DOOR CEILING DIFFUSER 75 CFM REQUIRED ION Subject to compliance with all regulations x of State and Local Odes. RETURN AIR GRILLE CITY OF �CWI 3NDIA A ® EXHAUST FANG o U 7 2'X4' LIGHT FEB - 5 2i";A O CAN LIGHT A FIXTURE DESIGNATION /a 7-7S- CEILING MOUNTED FIXTURE /s/D WALL MOUNTED LIGHT FIXTURE J O A FIXTURE DESIGNATION J - ix \ tn 8 a 4 SWITCH AT 44" AFF UNLESS NOTED OTHERWISE, Pi N ?0 r-"' $ M 0 SWITCH D� DIMMER, 3 -WAY, HEIGHT t a 120 VOLT 3 PRONG DUPLEX OUTLET a AT 12" AFF LIN" FQ NIC I Fn � O ; OTHERWISE ( 240 VOLT OUTLET AT 12" AFF UNLESS �C NOTED OTHERWISE PHONE / DATA JACK AT 12" AFF UNLESS NOTED OTHERWISE Ln7 CABLE TELEVISION JACK AT 12" AFF UNLESS NOTED OTHERWISE �A ALARM CONTROL PANEL OSMOKE DETECTOR OS SPEAKER ih O O N O OQ a 'od 0 N Bv' U d _� o :r c u 0 U Qa � � v o v v u d y Q �' b qy s. �¢ E ry 8 � Fg tl a1 a i . Ir o JOHN MOSELE ARGHITEGT ARCHITECTURE PLANNING INTERIOR ARCHITECTURE 317-574-9408 ERICk . MOB; REGISTERED 0 0 33389 — STATE OF i INDIANA KEY MAP 'I ST FLOOR) BRENWICK TND COMMUNITIES, LLC BRENWICK SALES OFFICE AT THE VILLAGE: OF WE:STCLAY reVl51on: date: de5cription: First Floor Plan date: January 15, 2008 project: OG 14 scale: A5 noted coord.: JMA drawn: LLD A1.1 checked: JMA