Loading...
HomeMy WebLinkAbout08020118.22' o 0 F1 STANDARD FRAME FRAME ELEVATION 03 1 FRAME ELEVATIONS �-oScale: N.T.S. DOOR YADTH DOOR IMDTH 1 4• TEMPERED GLASS 0 0 0 0 0 A B 02 DOOR ELEVATIONS A2.0%% Scale: N.T.S. O I CV LO O I r LO t O I cV 1B• TO I 12' MIN. TO DOOR STANDARD DOOR LOCATION 16' -5" 4- MIN. TO DODR 5" o4 TYPICAL HEAD @ INTERIOR DOOR o5 TYP. JAMB@ INTERIOR DOOR A2. o Scale: 3" = 1' -0" A2 • o Scale: 3" = V -0" 11 1 A" 5" 5" 5" 5" 41, A" AV n" n9 A" 1AI -AIL" FLOOR PLA Scale: 1/4" = V -0" r_ FINISH PLAN GENERAL NOTES: GENERAL NOTES MIRROR- 24 x 48 EACH SIDE OF NOTED SIZE 25 GAGE STL. STUDS AT A. ALL DIMENSIONS ARE FROM OUTSIDE FACE OF FINISHED SURFACE, S 9 3 W G7 TO OUTSIDE FACE OF FINISHED SURFACE. ANY DIMENSIONS NOT 1. G.C. TO SUBMIT TO TENANT SAMPLES OF ALL MATERIALS TO BE INSTALLED. A SHOWN C DEEMED QUESTIONABLE ARE TO BE VERIFIED BY ARCHITECT. DO NOT SCALE DRAWINGS. < o x !k HM -HOLLOW METAL CORREWOOD SOLID AL- ALUMINUM T= TEMPERED B. SEE WALL TYPE LEGEND FOR WALL CONSTRUCTION. 2. ALL INTERIOR FINISH AND TRIM TO MEET OR EXCEED CLASS II FLAME SPREAD, T HM F7 26 - 75 AND SMOKE DEVELOPMENT RATING LESS THAN 450 AND ALL OTHER C. PROVIDE WOOD BLOCKING SUPPORT AS REQUIRED. - APPLICABLE CODES OR BUILDING STANDARDS. D. COORDINATE WORK OF THIS TRADE WITH OTHER TRADES. 1008 3'-0 "x 7' -O'x 1 -3/4' E. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH T HM F7 ALL APPLICABLE CODES, LAWS AND ORDINANCES. 3. U.N.O. ALL PARTITIONS TO RECEIVE PAINT PT-1. - - 1 F. CONTACT RESPECTIVE UTILITY COMPANY FOR EXACT LOCATION WSC B T OF SERVICES PRIOR TO START OF CONSTRUCTION. PROTECT 4. ALL PARTITIONS RECEIVING PAINT TO RECEIVE PRIMER COAT PRIOR TO FINISH PAINT COATS. 04 EXISTING SERVICE DURING CONSTRUCTION. - - G. DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. 5. ALL PARTITIONS RECEIVING (PT -2) TO RECEIVE COMPLETE SKIM COAT PRIOR TO PRIME AND WSC WHERE MORE THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX - FINISH COATS TO AVOID PAINT FLASHING. ADDITIONAL FINISH COATS WILL BE REQUIRED. F1 HAS BEEN ADDED (I.E. 1000A). REFERENCE DOOR SCHEDULE. 04 05 H. CAULK JUNCTURES BETWEEN DIFFERENT MATERIALS (I.E. 6. ALL PAINTED SURFACES TO RECEIVE THE FOLLOWING FINISHES: 104 STOREFRONT AND GYPSUM BOARD). WSC G.W.B. VERTICAL WALL SURFACES EGGSHELL J. EACH CONTRACTOR SHALL PROVIDE ALL BARRICADES, ETC. AS F1 - 04 REQUIRED BY LAW, CODE OR ORDINANCE AND AS OTHERWISE - G.W.B. CEILINGS, SOFFITS, BULKHEADS FLAT 4 REQUIRED. 107 HOLLOW METAL SURFACES SEMI -GLOSS K. ALL STEEL STUDS ARE TO BE BRACED ACCORDING TO T PAINTED WOOD SURFACES SEMI -GLOSS F7 MANUFACTURER'S LIMITING HEIGHT 1/ OVER 240. 04 05 L. REMOVE ALL TRASH AND DEBRIS FROM THE JOB SITE DAILY. 7. G.C. TO PROVIDE PAINT SAMPLES OF ALL PAINTS TO BE USED IN PROJECT. SAMPLES TO BE M. ALL METAL STUD WALLS WHICH EXTEND TO DECK SHALL BE WSC THE SPECIFIED COLOR AND FINISH FOR REVIEW. T CONSTRUCTED WITH A CONTINUOUS SLIP TRACK AT TOP OF WALL. F1 - 04 TRACK SHALL BE SIZED TO ALLOW FOR MINIMUM DECK DEFLECTION - - 2 OF 1/2". 8. ALL LIGHT SWITCH AND OUTLET COVER PLATES TO BE SELECTED BY TENANT. WSC B - HM N. PREPARE FLOORS TO RECEIVE SPECIFIED FLOOR FINISHES. GRIND 04 05 - ALL HIGH AREAS AND FILL LOW AREAS WITH LATEX CEMENT. CLEAN 9. U.N.O. ALL NEW, EXISTING, AND RELOCATED HOLLOW METAL FRAMES TO RECEIVE PAINT COLOR 115 OUT ALL EXPANSION JOINTS AND CONTROL JOINTS AND FILL WITH WSC TO MATCH WALL ON WHICH THEY OCCUR. T LATEX CEMENT. REMOVE OLD ADHESIVE THAT WILL PROHIBIT THE F7 - 04 ADHESION OF NEW FINISHES. 10. U.N.O. INSTALL CARPET PER CARPET MANUFACTURER'S RECOMMENDATION. 0. ALL DUCTWORK MUST BE HELD A MINIMUM OF 10' -8" A.F.F. ALL 116 3' -0 "x 7' -O "x 1 -314" WSC HVAC SUPPLY AND RETURN AIR DIFFUSER MUST BE LOCATED TO - VERIFY WITH CARPET MANUFACTURER. F1 ACCOMODATE LOCATIONS OF LIGHT FIXTURES. 11. PROVIDE COMMUNICATIONS RECEPTACLES AND ELECTRICAL OUTLETS AT LOCATIONS NOTED. P' PROVIDE EXHAUST FAN IN RESTROOMS AS REQUIRED BY CODE. 2 Q. IF ADDITIONAL ROOF TOP UNIT(S) ARE REQUIRED, ALL PATCH AND WSC B - REPAIR OF ROOFING MUST BE COMPLETED BY ROOFING CONTRACTOR 12. U.N.O. INSTALL CARPET REDUCER AT ALL TRANSITIONS BETWEEN CARPET AND RESILIENT 04 TO MAINTAIN ROOF WARRANTY. - FLOORING. COLOR OF CARPET REDUCER TO MATCH RESILIENT FLOORING. R. CONTRACTOR IS RESPONSIBLE FOR SEPARATE ELECTRICAL, GAS 118 3' -O "x 7' -0'x 1 -3/4' WSC AND WATER SERVICE TO THE TENANT AREAS. SEPARATE SERVICES - HM F7 AS REQUIRED PER LOCAL UTILITY COMPANY. ALL METERS TO BE 04 05 - IN ONE LOCATION. 2 S. PROVIDE WALL MOUNTED FIRE EXTINGUISHERS AND CABINETS AS WSC B - REQUIRED BY LOCAL CODE. F1 - T. WHEN ELECTRICAL/ TELEPHONE/ DATAJACKS ARE INDICATED TO BE - - 4 INSTALLED IN A FIRE WALL, LANDLORD WILL PROVIDE AN ELECTRICAL/ 120 3' -O "x 7' -0'x 1 -3/4' WSC DATA CHASE TO BE LOCATED AT WALL BASE. - HM U. WHERE CONDUIT IS REQUIRED, ELECTRICAL SHOULD BE SEPARATE 04 05 - FROM TELEPHONE/ DATA. 2 V. PROVIDE A 4" CONDUIT FROM BUILDING COMMUNICATIONS ROOM TO WSC B - TENANT COMMUNICATION ROOM. F7 - W. PROVIDE A MINIMUM OF AT LEAST ONE LIGHT SWITCH TO BE LOCATED - - 2 NEAR BOTH THE FRONT AND REAR ENTRANCES / EXITS. 121B HVAC: X. MINIMUM REQUIREMENT THAT ALL ROOMS BE PROVIDED WITH SEPARATE - HM F1 SUPPLY AND RETURN AIR OR AS GOVERNED BY LOCAL CODE ALL ROOMS 04 05 - WHERE NOTED ON PLAN SUPPLY AND RETURN AIR IS REQUIRED. 1 DATA: Y. CONSULT WITH OWNER FOR REQUIREMENTS 3' -O "x 7' -0 "x 1 -3/4" WSC B O HM F1 PLAN NOTES 04 05 PROVIDE ONE FIRE EXTINGUISHER. i LOCATION TO BE DETERMINED BY FIRE MARSHALL DOOR AND FRAME SCHEDULE NO. DOOR SIZE FRAME REMARKS MIRROR- 24 x 48 EACH SIDE OF NOTED SIZE 25 GAGE STL. STUDS AT i �wy tl S 9 3 W G7 4 ZS o x m A z ¢ m < o x !k HM -HOLLOW METAL CORREWOOD SOLID AL- ALUMINUM T= TEMPERED 100A 3' -0 "x 7' -O "x 1 -3/4" WSC A T HM F7 - 04 05 - 1HR 1 GRAB BAR -36" 1008 3'-0 "x 7' -O'x 1 -3/4' WSC B T HM F7 - 04 05 - - 1 1000 3' -0 "x 7' -O "x 1 -3/4" WSC B T HM F1 - 04 05 - - 1 102 3' -0 "x 7' -0 "x 1 -3/4' WSC B - HM F1 - 04 05 - - 2 104 2- 3' -0 "x 7' -O'x 1 -3/4' WSC B - HM F1 - 04 05 - - 4 107 3' -0 "x 7' -0 "x 1 -3/4" WSC A T HM F7 - 04 05 - - 2 11: 3' -0 "x 7' -0'x 1 -314" WSC A T HM F1 - 04 OS - - 2 114 3' -O'x 7' -0'x 1 -3/4" WSC B - HM F7 - 04 05 - - 3 115 3' -0 "x 7' -O "x 1 -3/4" WSC B T HM F7 - 04 OS - I - 2 116 3' -0 "x 7' -O "x 1 -314" WSC B - HM F1 - 04 05 - - 2 117 2- 3' -0'x 7' -0'x 1 -3/4" WSC B - HM F1 - 04 05 - - 4 118 3' -O "x 7' -0'x 1 -3/4' WSC B - HM F7 - 04 05 - - 2 119 2- 3' -0'x 7' -0 "x 1 -3/4' WSC B - HM F1 - 04 05 - - 4 120 3' -O "x 7' -0'x 1 -3/4' WSC B - HM F7 - 04 05 - - 2 121A 3' -0 "x 7' -0 "x 1 -3/4" WSC B - HM F7 - 04 05 - - 2 121B 3' -0 "x 7' -0 "x 1 -3/4" WSC B - HM F1 - 04 05 - 1HR 1 TENANT TO COORDINATE LOCKING SYSTEM REWIRED AT THIS DOOR FRONT DESK CONTROLLED 122 3' -O "x 7' -0 "x 1 -3/4" WSC B - HM F1 - 04 05 OPROVIDE 6 GA. WATER HEATER SUSPENDED FROM STRUCTURE LOCATED ABOVE RESTROOM. OELECTRICAL PANEL LOCATION OADJUSTABLE SHELVES OLOCKERS (BY TENANT) OMEDICAL EQUIPMENT PROVIDED BY SULLIVAN- SCHEIN OWALL MOUNTED NITROUS OXIDE REGISTER WALL TYPES NOTE (1): USE TYPE X GYPSUM WALLBOARD FOR ALL LOCATIONS. W1 1 LAYER 5/8- TYPE X GYPSUM WALL BOARD ON t"7777777 777 EACH SIDE OF 3 5/8" 25 GAGE STL. STUDS AT 16' O.C. WITH SOUND ATTENUATION BLANKETS TO 6" ABOVE THE CEILING HEIGHT. W2 1 LAYER 5/8' TYPE X GYPSUM WALL BOARD ON EACH SIDE OF 3 5/8" 25 GAGE STL. STUDS AT 16' O.C. TO 6" ABOVE CEILING HEIGHT. W3 1 LAYER 5/8' TYPE X GYPSUM WALL BOARD ON J TENANT SIDE OF EXISTING 6" 22 GAGE STL. STUDS AT 16"0 C. WITH SOUND ATTENUATION BLANKETS FOR FULL HEIGHT OF WALL. 1 HOUR RATED WALL. 1 DOOR CLOSER 3 HINGES 1 OFFICE LOCKSET (LEVER) 1 WALL STOP 3 HINGES 1 STOREROOM LOCKSET (LEVER) 1 WALL STOP HARDWARE SET i4 MANUFACTURERS STANDARD INCLUDING: DOOR PULLS DOOR FLOOR AND HEAD GUIDES TOILET ACCESSORY SCHEDULE W4 1 LAYER 5/8' TYPE X GYPSUM WALL BOARD ON , , 77.77 , ,., MIRROR- 24 x 48 EACH SIDE OF NOTED SIZE 25 GAGE STL. STUDS AT HARDWARE SCHEDULE 6'O.C. WITH SOUND ATTENUATION MAX AFF TO BOT. FULL HEIGHT OF WALL. WALL TO GO TOSTEE DECK. HARDWARE SET h 1 LAYER 5/8' TYPE X GYPSUM WALL BOARD ON W5 3 HINGES BOTH SIDES OF 3 5/8' 25 GAGE STL. STUDS AT 1 PRIVACY LOCKSET (LEVER) 16' O.C. FOR FULL HEIGHT OF WALL. i HOUR RATED 1 KICKPLATE WALL. 1 DOOR CLOSER 3 HINGES 1 OFFICE LOCKSET (LEVER) 1 WALL STOP 3 HINGES 1 STOREROOM LOCKSET (LEVER) 1 WALL STOP HARDWARE SET i4 MANUFACTURERS STANDARD INCLUDING: DOOR PULLS DOOR FLOOR AND HEAD GUIDES TOILET ACCESSORY SCHEDULE Ti MIRROR- 24 x 48 MOUNTED 038" MAX AFF TO BOT. T2 TOILET PAPER DISPENSER MOUNTED 027" AFF TO CL T3 SURFACE MOUNTED PAPER MOUNTED 067" TOWEL DISPENSER/WASTE RECEPT., AFF TO TOP NOT REQUIRED T4 SANITARY NAPKIN DISPOSAL MOUNTED 027" AFF TO CL T5 GRAB BAR -36" MOUNTED 036" AFF TO CL T6 GRAB BAR -42" MOUNTED 036" AFF TO CL ELECT. /DATA /TELECOM M. SYMBOLS LEGEND: 0 NEW DUPLEX RECEPTACLE Alw NEW TELECOMM./DATA RECEPTACLE WITH WALL MOUNTED RECEPTACLE AT THIS LOCATION (bW DUPLEX RECEPTACLE MOUNTED AT CEILING HEIGHT FOR WALL MOUNTED T.V. ow CABLE OUTLET CONNECTION MOUNTED AT CEILING HEIGHT FOR WALL MOUNTED T.V. b2 TWO DUPLEX RECEPTACLES REQUIRED IN THIS AREA [V r N +' M Q) C: U) C M 0:6 U) a+ C o °' 3 LLJ > 1; c U) 0 CJ) 0 Ih Q M F4 a N i L 0 3 0 0 38aa z �� r x L. g A € ci . A S.3 to O o���o� J H- Cn c0 I� Lij :z LLJ z Q O Ld �QQOO F- O�ZMM U w z LLJ o W 3 OD L LJ U J O UrnCCLL -J d LL: �000 z o C/3 J = CV Co M Cu i �' Cu C' Z-C:) En Od7 E U3 rvoloz Q Qx. O O C/3. LL No * AR10100052 1 STATE OF DATE. 4 FEB 2008 REVS: SHEET NUMBER: 0 A 2,0