HomeMy WebLinkAbout08020118.3CEILING LEGEND
- - -
EXTEND WALL TO DECK
®
2 x 4 FLUORESCENT 4 BULB PARABOLIC LENS
-
2 x 2 HVAC RETURN AIR GRILLE
®
2 x 2 HVAC DIFFUSER
®
EXIT LIGHT FIXTURE
®
EMERGENCY LIGHT FIXTURE
ELSQ FRK
EMERGENCY WALL PACK WITH BATTERY BACKUP
O
1' X 4' FLU. 2 BULB SHOP LIGHT.
ELECTRICAL LEGEND
MARK
D CAT 5 OR HIGHER CABLE & DATAJACK
❑
S- -1_
b NEW TELPHONEJACK (WALL)
-
b NEW ANALOG PHONE LINE FOR POLYCOM
LITHONIA
$ NEW ELECTRICAL OUTLET (WALL)
UNIVERSAL MTD. 1 FACE
W GREEN LED
NEW ELECTRICAL OUTLET WITH GROUND FACE
EM
INTERRUPT CIRCUIT
ELSQ FRK
NEW QUADPLEX ELECTRICAL OUTLET (WALL)
EFP
2 CIRCUIT END PWR IN (SHARED NEUTRAL) - ELEC /PH /LAN
- ❑R-
SUPPLIED FROM WALL INTO PANEL VIA END FEED POWER.
BPI
ELECTRICAL DISTRIBUTED 2 EACH PER STATION.
- ❑R-
THE TOTAL NUMBER OF PH /DATA /LAN JACKS HAS
EPI
BEEN DESIGNATED AT EACH POWER IN TO BE
RECEPTACLES:
DISTRIBUTED AS INDICATED ON PANEL PLAN.
HUBBEL NO.
WHEN POWER IS SUPPILIED IN TO PANELS A LICENSED
SINGLE - 5351
ELECTRICIAN HARDWIRES THE LEADS. REFER TO PANEL
DUPLEX -5352
FOR ELEC /PH /DATA /LAN DISTRIBUTION WITHIN PANELS.
TFP
2 CIRCUIT PWR POLE(SHARED NEUTRAL) - ELEC /PH /LAN
-❑R-
PPL
ELECTRICAL DISTRIBUTED 2 EACH PER STATION.
RECESSED CEILING MOUNTED EXHAUST FAN - SEE
THE TOTAL NUMBER OF PH /DATA /LAN JACKS HAS
MECHANICAL DRAWINGS FOR CFM. 120 VOLT WIRED TO
BEEN DESIGNATED AT EACH POWER IN TO BE
LIGHT FIXTURE UNLESS NOTED OTHERWISE.
DISTRIBUTED AS INDICATED ON PANEL PLAN.
COMPLETE FOR USE.
WHEN POWER IS SUPPILIED IN TO PANELS A LICENSED
15 AMP ELECTRICAL SWITCH, 120 VOLT, WITH COVER
ELECTRICIAN HARDWIRES THE LEADS. REFER TO PANEL
PLATE.
FOR ELEC PH DATA LAN DISTRIBUTION WITHIN PANELS.
ELECTRICAL SPECIFICATION NOTES
1. ALL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE
NATIONAL ELECTRICAL CODE (NEC) AS ADOPTED BY THE INDIANA
STATE BUILDING COMMISION.
2. USE GROUND FAULT INTERRUPTER RECEPTACLES IN ALL LOCATIONS
REQUIRED BY THE NEC, TOILET ROOMS, AND WHERE INDICATED ON
DRAWINGS.
3. FURNISH DISCONNECT SWITCHES AT ALL HVAC & PLUMBING
EQUIPMENT AND AS INDICATED ON DRAWINGS.
4. GROUND ELECTRICAL EQUIPMENT AS REQUIRED BY NEC.
5. TEST ALL CIRCUITS FOR CONTINUITY, SHORTS & GROUNDS REPLACE
ANY CIRCUITS FOUND DEFECTIVE.
6. PANELBOARD LOADS SHALL BE BALANCED WITHIN 10 PERCENT FOR
ALL PHASES.
7. INSTALL UNDERGROUND CONDUIT A MINIMUM OF 18" BELOW RNISHE
GRADE.
8. ELECTRICAL CONTRACTOR SHALL PAY FOR ALL PERMITS AND
INSPECTIONS AND PROVIDE CERTIFICATE OF INSPECTION.
9. ELECTRICAL CONTRACTOR SHALL VERIFY UTILITY CO.
REQUIREMENTS AND CHARGES PRIOR TO BIDDING AND INCLUDE
COST OF SAME IN BID.
10. ELECTRICAL CONTRACTOR SHALL PROPERLY WARE ALL EQUIPMENT
INCLUDING TENANT SUPPLIED EQUIPMENT AND EQUIPMENT SUPPLIED
BY OTHER TRADES.
11. LANDLORD WILL PROVIDE BOX AND WIRING ABOVE CEILING TO
BUILDING STANDARD LIGHTING IN REAR PORTION OF SPACE; FUTURE
SNATCHES, WALL BOXES AND WIRING WILL BE INSTALLED BY
OTHERS (N.I.C.).
LIGHTING FIXTURE SCHEDULE
MARK
DISCONNECT SWITCHES:
S- -1_
SQUARE 'D' GENERAL DUTY
-
EX
LITHONIA
LQMSB1G120/
227EL
UNIVERSAL MTD. 1 FACE
W GREEN LED
70W HPS
EM
LITHONIA
ELSQ FRK
RECESSED BATTERY
POWERED
70W HPS
F
UTHONIA
2SPG332
RECESSED 2x4 LAY -IN
W PRISMSATIC LENS
F32/T8/35K
ELECTRICAL EQUIPMENT
CONDUIT:
DISCONNECT SWITCHES:
INSIDE BUILDING - EMT
SQUARE 'D' GENERAL DUTY
OUTSIDE BUILDING - PVC
TYPE WITH NEMA 1 OR NEMA 3R
120/208 VOLT PER LANDLORD AND PER
ENCLOSURE AS REQUIRED FOR
CONDUCTORS:
APPLICATION
COPPER THHN OR THWN
U
W
1x4 FLUORESCENT (2) TUBE INDUSTRIAL
PANELBOARDS:
SWITCHES:
SQUARE V NQOD NTH BOLT ON
HUBBEL NO.
CIRCUIT BREAKERS
SINGLE POLE - 1221
MIN INTERRUPTING CAP. 10,000A
3 -WAY - 1223
—
4 -WAY - 1224
RECEPTACLES:
HUBBEL NO.
EM
SINGLE - 5351
DUPLEX -5352
®
PANEL
"P1"
120/208V.,
MO 3PH., 4W.
4 - #310, 1#4, 2 "C. GROUND PER
NEC
ELECTRICAL RISER DIAGRAM
o2 ELECTRICAL RISER DIAGRAM
A2.1 Scale: N.T.S.
LIGHTING GENERAL NOTES
1. ELECTRICAL CONTRACTOR (E.C.) SHALL COORDINATE LIGHT
FIXTURE LOCATIONS WITH MECHANICAL CONTRACTOR (M.C.) PRIOR
TO LIGHT INSTALLTION.
2. SMOKE DETECTORS, ALARMS AND SIRENS TO BE DESIGNED AND INSTALLED BY
MANUFACTURER /INSTALLER, COORDINATE WITH LANDLORD.
3. ALL LIGHT FIXTURES SHALL BE NEW AND IN GOOD WORKING ORDER.
AND SHALL COMPLY WITH "UL" CLASSIFICATIONS.
4. ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO ALL CURRENT LOCAL,
STATE AND FEDERAL CODES, ORDINANCES, AND STANDARDS.
5. E.C. SHALL CONTACT ARCHITECT OF ANY DISCREPANCIES BETWEEN DRAWINGS
AND APPLICABLE CODE PRIOR TO START OF CONSTRUCTION.
6. E.C. TO PROVIDE ALL LABOR, MATERIAL, EQUIPMENT AND SERVICES REQUIRED
TO COMPLETE INSTALLATION OF SYSTEMS REQUIRED TO MEET AND COMPLY WITH
ALL APPLICABLE CODES, FINISHED PROJECT SHALL BE COMPLETE AND FUNCTIONAL
FOR IMMEDIATE USE.
7. E.C. TO PROVIDE AND INSTALL ALL DISCONNECT SWITCHES AND FINAL HOOK -UPS
TO APPLICABLE EQUIPMENT, RTU'S, ETC.
LIGHTING SCHEDULE
CV f- N +'
CD I`
0 N
N
C M
O (0
C L
0
v °� CO 3
W '>
rn 0
O) p M
m IV a N
`W
i
L
O
3
C
O
E 9
spy €E o
aa° ,9
a_
2x4 FLUORESCENT (2) TUBE LIGHT FIXTURE
A
� N to
120/208 VOLT PER LANDLORD AND PER
LLd
D
TENANT. LAY -IN TYPE WITH ACRYLIC LENS
AND WIRING PIGTAIL COMPLETE FOR USE.
U
W
1x4 FLUORESCENT (2) TUBE INDUSTRIAL
�
O
LIGHT FIXTURE. 120/208 VOLT, LAY -IN
TYPE. WITH WIRING PIGTAIL. PER LAND-
a_
LORD. COMPLETE FOR USE.
C o
WALL MOUNTED 60 WATT INCAN. LIGHT FIXTURE
—
120 VOLT, 5 BULB. PER LANDLORD AND PER
TENANT. COMPLETE FOR USE.
UNIVERSAL MOUNTED 2 HEAD EMERGENCY LIGHT
EM
FIXTURE WITH BATTERY BACKUP. FIXTURE TYPE PER
LANDLORD AND TENANT. COMPLETE FOR USE.
®
UNIVERSAL MOUNTED EXIT LIGHT FIXTURE WITH
X
WITH BATTERY BACKUP. FIXTURE TYPE PER
LANDLORD AND TENANT. COMPLETE FOR USE.
RECESSED CEILING MOUNTED EXHAUST FAN - SEE
MECHANICAL DRAWINGS FOR CFM. 120 VOLT WIRED TO
LIGHT FIXTURE UNLESS NOTED OTHERWISE.
COMPLETE FOR USE.
15 AMP ELECTRICAL SWITCH, 120 VOLT, WITH COVER
PLATE.
NL
INDICATES "NIGHT LIGHT" ALWAYS ON.
CV f- N +'
CD I`
0 N
N
C M
O (0
C L
0
v °� CO 3
W '>
rn 0
O) p M
m IV a N
`W
i
L
O
3
C
O
E 9
spy €E o
aa° ,9
z
REFLECTED CEILING PLAN
A2 • Scale: 1/4" = 1' -0"
z
Q
Q
U
re
U
W
I
W
No
* : AR10100052
i •%
STATE OF
DATE: 4 FEB 2008
REVS:
SHEET NUMBER:
0
A 2,1
a_
L �
J
� N to
WzQ
�Q¢00
LLd
D
pp
Z M M
U
W
w Z
�
O
m W U J
Urn
CCLL- J
a_
LL:�000
z
REFLECTED CEILING PLAN
A2 • Scale: 1/4" = 1' -0"
z
Q
Q
U
re
U
W
I
W
No
* : AR10100052
i •%
STATE OF
DATE: 4 FEB 2008
REVS:
SHEET NUMBER:
0
A 2,1