HomeMy WebLinkAbout08020118.3CEILING LEGEND - - - EXTEND WALL TO DECK ® 2 x 4 FLUORESCENT 4 BULB PARABOLIC LENS - 2 x 2 HVAC RETURN AIR GRILLE ® 2 x 2 HVAC DIFFUSER ® EXIT LIGHT FIXTURE ® EMERGENCY LIGHT FIXTURE ELSQ FRK EMERGENCY WALL PACK WITH BATTERY BACKUP O 1' X 4' FLU. 2 BULB SHOP LIGHT. ELECTRICAL LEGEND MARK D CAT 5 OR HIGHER CABLE & DATAJACK ❑ S- -1_ b NEW TELPHONEJACK (WALL) - b NEW ANALOG PHONE LINE FOR POLYCOM LITHONIA $ NEW ELECTRICAL OUTLET (WALL) UNIVERSAL MTD. 1 FACE W GREEN LED NEW ELECTRICAL OUTLET WITH GROUND FACE EM INTERRUPT CIRCUIT ELSQ FRK NEW QUADPLEX ELECTRICAL OUTLET (WALL) EFP 2 CIRCUIT END PWR IN (SHARED NEUTRAL) - ELEC /PH /LAN - ❑R- SUPPLIED FROM WALL INTO PANEL VIA END FEED POWER. BPI ELECTRICAL DISTRIBUTED 2 EACH PER STATION. - ❑R- THE TOTAL NUMBER OF PH /DATA /LAN JACKS HAS EPI BEEN DESIGNATED AT EACH POWER IN TO BE RECEPTACLES: DISTRIBUTED AS INDICATED ON PANEL PLAN. HUBBEL NO. WHEN POWER IS SUPPILIED IN TO PANELS A LICENSED SINGLE - 5351 ELECTRICIAN HARDWIRES THE LEADS. REFER TO PANEL DUPLEX -5352 FOR ELEC /PH /DATA /LAN DISTRIBUTION WITHIN PANELS. TFP 2 CIRCUIT PWR POLE(SHARED NEUTRAL) - ELEC /PH /LAN -❑R- PPL ELECTRICAL DISTRIBUTED 2 EACH PER STATION. RECESSED CEILING MOUNTED EXHAUST FAN - SEE THE TOTAL NUMBER OF PH /DATA /LAN JACKS HAS MECHANICAL DRAWINGS FOR CFM. 120 VOLT WIRED TO BEEN DESIGNATED AT EACH POWER IN TO BE LIGHT FIXTURE UNLESS NOTED OTHERWISE. DISTRIBUTED AS INDICATED ON PANEL PLAN. COMPLETE FOR USE. WHEN POWER IS SUPPILIED IN TO PANELS A LICENSED 15 AMP ELECTRICAL SWITCH, 120 VOLT, WITH COVER ELECTRICIAN HARDWIRES THE LEADS. REFER TO PANEL PLATE. FOR ELEC PH DATA LAN DISTRIBUTION WITHIN PANELS. ELECTRICAL SPECIFICATION NOTES 1. ALL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE (NEC) AS ADOPTED BY THE INDIANA STATE BUILDING COMMISION. 2. USE GROUND FAULT INTERRUPTER RECEPTACLES IN ALL LOCATIONS REQUIRED BY THE NEC, TOILET ROOMS, AND WHERE INDICATED ON DRAWINGS. 3. FURNISH DISCONNECT SWITCHES AT ALL HVAC & PLUMBING EQUIPMENT AND AS INDICATED ON DRAWINGS. 4. GROUND ELECTRICAL EQUIPMENT AS REQUIRED BY NEC. 5. TEST ALL CIRCUITS FOR CONTINUITY, SHORTS & GROUNDS REPLACE ANY CIRCUITS FOUND DEFECTIVE. 6. PANELBOARD LOADS SHALL BE BALANCED WITHIN 10 PERCENT FOR ALL PHASES. 7. INSTALL UNDERGROUND CONDUIT A MINIMUM OF 18" BELOW RNISHE GRADE. 8. ELECTRICAL CONTRACTOR SHALL PAY FOR ALL PERMITS AND INSPECTIONS AND PROVIDE CERTIFICATE OF INSPECTION. 9. ELECTRICAL CONTRACTOR SHALL VERIFY UTILITY CO. REQUIREMENTS AND CHARGES PRIOR TO BIDDING AND INCLUDE COST OF SAME IN BID. 10. ELECTRICAL CONTRACTOR SHALL PROPERLY WARE ALL EQUIPMENT INCLUDING TENANT SUPPLIED EQUIPMENT AND EQUIPMENT SUPPLIED BY OTHER TRADES. 11. LANDLORD WILL PROVIDE BOX AND WIRING ABOVE CEILING TO BUILDING STANDARD LIGHTING IN REAR PORTION OF SPACE; FUTURE SNATCHES, WALL BOXES AND WIRING WILL BE INSTALLED BY OTHERS (N.I.C.). LIGHTING FIXTURE SCHEDULE MARK DISCONNECT SWITCHES: S- -1_ SQUARE 'D' GENERAL DUTY - EX LITHONIA LQMSB1G120/ 227EL UNIVERSAL MTD. 1 FACE W GREEN LED 70W HPS EM LITHONIA ELSQ FRK RECESSED BATTERY POWERED 70W HPS F UTHONIA 2SPG332 RECESSED 2x4 LAY -IN W PRISMSATIC LENS F32/T8/35K ELECTRICAL EQUIPMENT CONDUIT: DISCONNECT SWITCHES: INSIDE BUILDING - EMT SQUARE 'D' GENERAL DUTY OUTSIDE BUILDING - PVC TYPE WITH NEMA 1 OR NEMA 3R 120/208 VOLT PER LANDLORD AND PER ENCLOSURE AS REQUIRED FOR CONDUCTORS: APPLICATION COPPER THHN OR THWN U W 1x4 FLUORESCENT (2) TUBE INDUSTRIAL PANELBOARDS: SWITCHES: SQUARE V NQOD NTH BOLT ON HUBBEL NO. CIRCUIT BREAKERS SINGLE POLE - 1221 MIN INTERRUPTING CAP. 10,000A 3 -WAY - 1223 — 4 -WAY - 1224 RECEPTACLES: HUBBEL NO. EM SINGLE - 5351 DUPLEX -5352 ® PANEL "P1" 120/208V., MO 3PH., 4W. 4 - #310, 1#4, 2 "C. GROUND PER NEC ELECTRICAL RISER DIAGRAM o2 ELECTRICAL RISER DIAGRAM A2.1 Scale: N.T.S. LIGHTING GENERAL NOTES 1. ELECTRICAL CONTRACTOR (E.C.) SHALL COORDINATE LIGHT FIXTURE LOCATIONS WITH MECHANICAL CONTRACTOR (M.C.) PRIOR TO LIGHT INSTALLTION. 2. SMOKE DETECTORS, ALARMS AND SIRENS TO BE DESIGNED AND INSTALLED BY MANUFACTURER /INSTALLER, COORDINATE WITH LANDLORD. 3. ALL LIGHT FIXTURES SHALL BE NEW AND IN GOOD WORKING ORDER. AND SHALL COMPLY WITH "UL" CLASSIFICATIONS. 4. ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO ALL CURRENT LOCAL, STATE AND FEDERAL CODES, ORDINANCES, AND STANDARDS. 5. E.C. SHALL CONTACT ARCHITECT OF ANY DISCREPANCIES BETWEEN DRAWINGS AND APPLICABLE CODE PRIOR TO START OF CONSTRUCTION. 6. E.C. TO PROVIDE ALL LABOR, MATERIAL, EQUIPMENT AND SERVICES REQUIRED TO COMPLETE INSTALLATION OF SYSTEMS REQUIRED TO MEET AND COMPLY WITH ALL APPLICABLE CODES, FINISHED PROJECT SHALL BE COMPLETE AND FUNCTIONAL FOR IMMEDIATE USE. 7. E.C. TO PROVIDE AND INSTALL ALL DISCONNECT SWITCHES AND FINAL HOOK -UPS TO APPLICABLE EQUIPMENT, RTU'S, ETC. LIGHTING SCHEDULE CV f- N +' CD I` 0 N N C M O (0 C L 0 v °� CO 3 W '> rn 0 O) p M m IV a N `W i L O 3 C O E 9 spy €E o aa° ,9 a_ 2x4 FLUORESCENT (2) TUBE LIGHT FIXTURE A � N to 120/208 VOLT PER LANDLORD AND PER LLd D TENANT. LAY -IN TYPE WITH ACRYLIC LENS AND WIRING PIGTAIL COMPLETE FOR USE. U W 1x4 FLUORESCENT (2) TUBE INDUSTRIAL � O LIGHT FIXTURE. 120/208 VOLT, LAY -IN TYPE. WITH WIRING PIGTAIL. PER LAND- a_ LORD. COMPLETE FOR USE. C o WALL MOUNTED 60 WATT INCAN. LIGHT FIXTURE — 120 VOLT, 5 BULB. PER LANDLORD AND PER TENANT. COMPLETE FOR USE. UNIVERSAL MOUNTED 2 HEAD EMERGENCY LIGHT EM FIXTURE WITH BATTERY BACKUP. FIXTURE TYPE PER LANDLORD AND TENANT. COMPLETE FOR USE. ® UNIVERSAL MOUNTED EXIT LIGHT FIXTURE WITH X WITH BATTERY BACKUP. FIXTURE TYPE PER LANDLORD AND TENANT. COMPLETE FOR USE. RECESSED CEILING MOUNTED EXHAUST FAN - SEE MECHANICAL DRAWINGS FOR CFM. 120 VOLT WIRED TO LIGHT FIXTURE UNLESS NOTED OTHERWISE. COMPLETE FOR USE. 15 AMP ELECTRICAL SWITCH, 120 VOLT, WITH COVER PLATE. NL INDICATES "NIGHT LIGHT" ALWAYS ON. CV f- N +' CD I` 0 N N C M O (0 C L 0 v °� CO 3 W '> rn 0 O) p M m IV a N `W i L O 3 C O E 9 spy €E o aa° ,9 z REFLECTED CEILING PLAN A2 • Scale: 1/4" = 1' -0" z Q Q U re U W I W No * : AR10100052 i •% STATE OF DATE: 4 FEB 2008 REVS: SHEET NUMBER: 0 A 2,1 a_ L � J � N to WzQ �Q¢00 LLd D pp Z M M U W w Z � O m W U J Urn CCLL- J a_ LL:�000 z REFLECTED CEILING PLAN A2 • Scale: 1/4" = 1' -0" z Q Q U re U W I W No * : AR10100052 i •% STATE OF DATE: 4 FEB 2008 REVS: SHEET NUMBER: 0 A 2,1