Loading...
HomeMy WebLinkAbout08010083.6REFLECTED CEILING PLAN •• • • • • • SCALE: 1/8 " =1' -0" REFLECTED CEILING LEGEND ....... ............................... ...... ............................... ....... ............................... ...... ............................... ....... ............................... ...... ............................... NOT IN CONTRACT DENOTES NEW 2'X 2' ACOUSTICAL CEILING TILE: ARMSTRONG, DUNE LAY -IN TILE IN COLOR WHITE, USE WITH ARMSTRONG 15/16" PRELUDE GRID :�M -'•' • DENOTES DRYWALL CEILING / BULKHEAD BUILDING STANDARD 2'X 4' THREE -TUBE FLUORESCENT LIGHTING FIXTURE WITH PRISMATIC LEN n (DAYBRITE 2SPG- 332- FS12- UNV- 1 /3EBIOR- LFT735, OR EQUAL) NOT USED BUILDING STANDARD 2'X 2' FLUORESCNET FIXTURE WITH PRISMATIC LENS. OD BUILDING STANDARD 6" RECESSED INCANDESCENT CANLIGHT (DAYBRITE S6A19- T6CS- Q1031, OR EQUAL) BUILDING STANDARD 6" RECESSED COMPACT FLUORESCENT FIXTURE OE (DAYBRITE S632PLTU- T6CS- Q1031, OR EQUAL) ® BUILDING STANDARD ASYMMETRICAL SINGLE LAMP FLUORESCENT FIXTURE (DAYBRITE 0607 -AR, OR EQUAL) z DENOTES 2'X 2' RETURN GRILLE ❑❑ DENOTES EXHAUST GRILLE (TIE INTO BUILDING SYSTEM) DENOTES STANDARD LIGHT SWITCH 3 DENOTES 3 -WAY LIGHT SWITCH D DENOTES DIMMER LIGHT SWITCH q� EMERGENCY LIGHTING WITH BATTERY BACK -UP U (MCPHILBEN CTX6LIZWCSWA, OR EQUAL) ® DIRECTIONAL EXIT SIGN (MCPHILBEN CXXL3RW, OR EQUAL) a NIGHT LITE REFLECTED CEILING PLAN KEYNOTES 01 MODIFY EXISTING CEILING GRID AND LIGHTING AS REQUIRED IN THIS LOCATION. 02 EXTEND CEILING WHERE BULKHEAD IS REMOVED. 03 BULKHEAD AT 8' -4" A.F.F. GENERAL REFLECTED CEILING PLAN NOTES A PAINT NEW GYPSUM BOARD BULKHEADS CEILING WHITE, UNLESS NOTED OTHERWISE. B THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING HEIGHTS AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING, AND OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT INDICATED. ANY DISCREPANCY SHALL BE BROUGHT TO THE DESIGNER'S ATTENTION PRIOR TO PERFORMING ANY WORK. C CEILING HEIGHT THROUGHOUT THE SPACE IS 8' -6" A.F.F., UNLESS NOTED OTHERWISE. CENTER ALL GRIDS WITHIN ROOM. D ALL NEW SWITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT CENTER OF SWITCH 6 " -9" FROM EDGE OF DOOR FRAME, UNLESS NOTED OTHERWISE. E EXIT SIGNS, DOWN LIGHTS, SPRINKLER HEADS, ETC. SHALL BE CENTERED WITHIN CEILING TILE, UNLESS NOTED OTHERWISE. F COLOR OF LIGHT SWITCH DEVICES AND COVERPLATE TO BE IVORY, UNLESS NOTED OTHERWISE. G ALL MULTIPLE SWITCH LOCATIONS TO BE GROUPED TOGETHER AND LABELED WITH A SINGLE DEVICE COVERPLATE. H THERMOSTATS SHALL BE LOCATED DIRECTLY ADJACENT TO LIGHT SWITCH. ALL THERMOSTAT POSITIONS AND LOCATIONS TO BE COORDINATED WITH THE DESIGNER BEFORE PLACEMENT. I SUPPLY AND RETURN AIR GRILLES ARE TO BE FLUSH WITH NEW CEILING TILES AND ARE TO BE WHITE IN COLOR. J ALL DIMENSIONS ARE TO THE CENTERLINE OF FIXTURE, UNLESS NOTED OTHERWISE. K IF REQUIRED, ALL CEILING MOUNTED EQUIPMENT LOCATIONS TO BE COORDINATED WITH THE DESIGNER PRIOR TO INSTALLATION. L VERIFY ALL SPRINKLER HEAD LOCATIONS. NOTIFY DESIGNER IF ANY DISCREPANCIES OCCUR. M PROVIDE FIRE DAMPERS AND SMOKE DAMPERS AS REQUIRED PER APPLICABLE BUILDING CODES. N CEILING IN ALL AREAS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS, AND ALL APPLICABLE BUILDING CODES. O MECHANICAL CONTRACTOR (MC) TO PRODUCE A DRAWING SHOWING DUCT LAYOUT FROM VAV UNITS TO DIFFUSERS SHOWN AND THERMOSTAT LOCATIONS. USE VAV BOXES LOCATED WITHIN THE DEMISED SPACE ONLY. IF ADDITIONAL VAV BOXES ARE REQUIRED, MC TO NOTE ADDITIONAL VAV BOX(ES) ON LAYOUT DRAWING AND IDENTIFY COST FOR SUPPLYING AND INSTALLING SAID BOX(ES). P HVAC THERMOSTAT CONTROL FOR ALL ROOMS SHALL BE LOCATED WITHIN DEMISED SUITE. VERIFY AND REWORK EXISTING DUCTWORK AND THERMOSTATS AS REQUIRED. Q MECHANICAL CONTRACTOR SHALL VERIFY WORKING CONDITION OF ALL EXISTING THERMOSTATS, VAV BOXES, EXHAUST FANS, AND ANY OTHER DEVICE DIRECTLY RELATED TO THE HVAC SYSTEM. CONTRACTOR TO NOTIFY ARCHITECT IMMEDIATELY UPON DISCOVERY OF DEFECTIVE DEVICE. R MECHANICAL CONTRACTOR TO CONNECT DESIGNATED EXHAUST GRILLES TO EXISTING EXHAUST SYSTEM. S SPRINKLER CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING ADEQUATE SPIRNKLER LAYOUT IN ALL SPACES FORMED BY NEW CONSTRUCTION AS WELL AS ANY EXISTING SPACES RECONFIGURED BY NEW CONSTRUCTION. LAYOUT MUST MEET ALL APPLICABLE LOCAL AND STATE CODES. REFER TO SPRINKLER DRAWINGS FOR ALL LOCATIONS OF THAT QEQUIPMENT, EITHER SHOWN OR NOT SHOWN HERE, AND COORDINATE WITH THE ARCHITECT AND MECHANICAL CONTRACTOR ANY CONFLICTS DISCOVERED BETWEEN THE SPRINKLER DRAWINGS AND ARCHITECTURAL DRAWINGS. T FACE OF BULKHEAD TO EXTEND 1" BEYOND FACE OF CASEWORK UNLESS OTHERWISE NOTED. Bch G N ania pkwy indiana 46280 ?222 ?230 esign.com .• • • • • • ARCHITECT, PC ON AVENURE NDIANA 46220 5820 (V) )468 (F) .• • • • • • N IT Y) Z M ::t O YQ �z Q t Z r r r V r .• • • • • Ili *06 �A k ti O 6 CV rWn �/ / z O U Z O U • . • • • • • • 1/8"=11-011 AR SGB 07033 . • • • • • • CTED PLAN A200 m� D►ES 501 pennsylv suite 160 indianapolis, ph 317.573.: fx 317.573.: www. m itschd DAVID POWERS - 5816 CARROLT INDIANAPOLIS, 317 -627 - 317 -255 -1 I�L J 0 U 0 Q J LL U) U W z c) 0 o� W j ^Q^ V 2 Z ~ C� w Q = W � � i G W 0 U 4y s< F M, Al 'Ay 3 5 a o 0 .— m= ir? 0 / Q j O J- Z LL r U) 0O��m❑ �J rwLU Z�=w WUQ 0 Z ¢ao�_ � ,� U U w O _ ?Z(7mJw �H� (n Q d Z�ooF� ZZ) 0 a. 0gyu) u) Q'(n Z0ZVLL �U)W W. 0 ,ax J W Z 0mw¢zai aUCn 0. LU 0. O� �waw0ii 00 LLI �aOQwV NO ¢�¢raow �N DWG SCALE: DRAWN BY: CHECKED BY: HMD PROJECT #: REFLE CEILING Bch G N ania pkwy indiana 46280 ?222 ?230 esign.com .• • • • • • ARCHITECT, PC ON AVENURE NDIANA 46220 5820 (V) )468 (F) .• • • • • • N IT Y) Z M ::t O YQ �z Q t Z r r r V r .• • • • • Ili *06 �A k ti O 6 CV rWn �/ / z O U Z O U • . • • • • • • 1/8"=11-011 AR SGB 07033 . • • • • • • CTED PLAN A200