HomeMy WebLinkAbout08010083.7ELECTRICAUDATA PLAN SCALE: 1/8 " =1' -0" NOTE: EQUIPMENT PROVIDED BY OTHERS AND SHOWN FOR REFERENCE ONLY ELECTRICAL /DATA LEGEND NOTINCONTRACT • mitl qp 110V STANDARD DUPLEX RECEPTACLE D E S 0 110V STANDARD QUAD FLOOR RECEPTACLE 501 pennsylN p VOICE /DATA OUTLET, PROVIDE SINGLE GANG BACK BOX AND %4° CONDUIT IN WALL, suite 160 STUBBED ABOVE CEILING. WIRING AND DEVICES BY OTHERS. Indianapolis, v VOICE ONLY OUTLET ph 317 .573.: GFI DENOTES GROUND FAULT INTERRUPTER fx 317.573. +## DENOTES CENTERLINE OF RECEPTACLE MOUNTING HEIGHT A.F.F. www.mitschd FE DENOTES CABLE READY TELEVSION RECEPTACLE DAVID POWERS - FE] DENOTES VISUAL FIRE ALARM 5816 CARROLI Av DENOTES AUDIOVISUAL FIRE ALARM ELECTRICAL /DATA PLAN KEYNOTES 01 LOWER RECEPTACLES THIS WALL TO 19" A.F.F. 02 ELECTRICAL REQUIREMENTS FOR THIS ROOM TO BE DETERMINED. 03 SWITCH FOR DISPOSAL. GENERAL ELECTRICAL /DATA NOTES A THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE DESIGNER OF ANY DISCREPANCIES BETWEEN THE U O CONTRACT DOCUMENTS AND APPLICABLE CODES PRIOR TO CONSTRUCTION. B ELECTRICAL CONTRACTOR TO COORDINATE ALL SPECIAL ELECTRICAL EQUIPMENT REQUIREMENTS LL AS INDICATED ON DRAWINGS OR AS REQUE=STED BY TENANT. VERIFY ACTUAL REQUIREMENTS WITH U DESIGNER PRIOR TO INSTALLATION. C ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES AND PULL STRINGS AT TELEPHONE /DATA r LOCATIONS AS INDICATED ON PLANS. COMPLETE TELEPHONE /DATA SYSTEMS (MATERIAL AND LABOR) U TO BE PROVIDED BY THE TENANT UNLESS OTHERWISE NOTED. D ALL SECURITY SYSTEMS TO BE PROVIDED BY TENANT UNLESS NOTED OTHERWISE. E ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL AND LIGHTING REQUIREMENTS FOR O MILLWORK AND CABINETRY WITH CONTRACTOR AS NECESSARY. F ALL WALL MOUNTED OUTLETS ARE TO BE MOUNTED VERTICALLY AT 19" A.F.F. TO CENTERLINE OF W > OUTLET, UNLESS OTHERWISE NOTED. G SWITCH PLATES, MONUMENTS, AND ELECTRICAL COVER PLATES SHALL BE IVORY, UNLESS NOTED OTHERWISE. H ALL DIMENSIONS SHOWN ARE TO CENTERLINE OF OUTLETS OR GROUP OF OUTLETS, UNLESS Z OTHERWISE NOTED. I DO NOT LOCATE BOXES BACK TO BACK WITHIN PARTITIONS. STAGGER AS REQUIRED TO MINIMIZE C� SOUND TRANSMISSION. J ADJACENT OUTLETS SHALL BE GANGED WHEN POSSIBLE. IF THEY CANNOT BE GANGED, THEY SHALL Q = BE INSTALLED WITH A MINIMUM DISTANCE BETWEEN UNITS. K CONTRACTOR TO PROVIDE ALL FIRE LIFE SAFETY DEVICES AS REQUIRED BY STATE AND LOCAL BUILDING CODES. L ELECTRICAL CONTRACTOR TO VERIFY WORKING CONDITION OF ALL SWITCHES, LIGHT FIXTURES, BALLASTS, EXIT, AND EMERGENCY LIGHTS AND OUTLETS, REPLACE IF NECESSARY. M DO NOT SCALE DRAWINGS; ALL DIMENSIONS GIVEN ARE TO BE ADHERED TO, UNLESS FIELD CONDITIONS DEEM OTHERWISE. ANY CONFLICTS THAT MAY EXIST WITH NEW CONSTRUCTION MUST � BE REVIEWED BY DESIGNER PRIOR TO CONSTRUCTION OF WORK. DO NOT CIRCUMVENT DIMENSIONS W O� BY ATTACHING RECEPTACLES TO NEAREST STUD. N THESE ELECTRICAL DRAWINGS REFLECT LOCATIONS ONLY. O ELECTRICAL /DATA OUTLET LOCATIONS TO BE VERIFIED WITH TENANT PRIOR TO ROUGH -IN. ALL Jyb'r� �i g, r ;'P F LOCATIONS TO BE VERIFIED WITH FURNITURE PLACEMENT. P SYSTEMS FURNITURE TO BE DRAWN ON FLOOR PRIOR TO PLACEMENT OF FLOOR CORE AND J 66' i JUNCTION BOXES. DESIGNER TO APPROVE LOCATIONS PRIOR TO CORING /PLACEMENT. Q ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CONNECTING DEALER PROVIDED FURNITURE SYSTEMS POWER IN -FEED TO BUILDING J -BOX WHERE INDICATED ON PLAN. R THE ELECTRICAL CONTRACTOR IS TO PROVIDE ALL REQUIRED LABOR, MATERIALS, EQUIPMENT, AND KZU JUJ 030��mo ILUJ CONTRACTORS SERVICES NECESSARY TO COMPLETE INSTALLATION OF SYSTEMS REQUIRED IN FULL ¢ 'oo=W, wz a U U LL OF, U) U)_O CONFORMITY WITH APPLICABLE CODES AND ORDINANCES. THE FINISHED JOB SHALL BE FUNCTIONAL u> ZZUrm�W c_C �; § QUm AND COMPLETE IN EVERY DETAIL INCLUDING ANY AND ALL SUCH ITEMS FOR A COMPLETE SYSTEM. S ALL MATERIALS AND WORKMANSHIP SHALL MEET ALL APPLICABLE STATE AND LOCAL CODES, 'w w O'X J H Luz ZF�Qm wo ORDINANCES, UTILITY COMPANY REGULATIONS AND NATIONALLY ACCEPTED CODES AND STANDARDS. �mw¢w aUfn moa oz o�T�Unm THE ELECTRICAL CONTRACTOR WILL BEAR ALL COSTS ARISING IN CORRECTING ANY NON awww0LL 00 COMPLIANCE WITH THE REQUIREMENTS OF APPLICABLE CODES. T CONTRACTOR TO SUPPLY AND INSTALL ALL ELECTRICAL WIRING, INCLUDING RUNS FROM JUNCTION Q w Q w o W BOX TO INDIVIDUAL WORKSTATION UNITS. CONTRACTOR TO SUPPLY PLENUM RATED BOXES AND DWG SCALE: PULLS AS REQUIRED TO ACCOMMODATE TENANT'S TELEPHONE, DATA AND SECURITY DEVICES. U ELECTRICAL HOME RUNS TO BE RUN TO EXISTING ELECTRICAL CLOSET. F lsd� �oc G N ania pkwy indiana 46280 ?222 ?230 esign.com . • • • • • • ARCHITECT, PC ON AVENURF NDIANA 46220 5820 (V) )468 (F) • mitl D E S 501 pennsylN suite 160 Indianapolis, ph 317 .573.: fx 317.573. www.mitschd DAVID POWERS - n 5816 CARROLI Z N M O INDIANAPOLIS, 317 -627- �Z 317 -255 -1 Y Z J 0 D J U O Z LU Q � LL -� U VJ r U W z U O O W > Q t ^ I v Z C� W Q = I W � I � W O� � U "o, Jyb'r� �i g, r ;'P F r.' s yl J 66' i sv „mss meow °z r 00 �� > F- w�w KZU JUJ 030��mo ILUJ ¢ 'oo=W, wz a U U LL OF, U) U)_O u> ZZUrm�W c_C �; § QUm aogymrn o'er m� ��w 'w w O'X J H Luz ZF�Qm wo �mw¢w aUfn moa oz o�T�Unm awww0LL 00 0Z H W W V'7 �aoQ U r Q w Q w o W DWG SCALE: DRAWN BY: CHECKED BY: HMD PROJECT #: ELECTRIC PU F lsd� �oc G N ania pkwy indiana 46280 ?222 ?230 esign.com . • • • • • • ARCHITECT, PC ON AVENURF NDIANA 46220 5820 (V) )468 (F) "1 06 1 • • • • • • 1 • • • • • • AS NOTED AR SGB 07033 1 • • • • • • AUDATA kN A300 0 0 N W U) Z n 0 Z N M O �Z D Y Z D J VJ Z LU Z O -� U "1 06 1 • • • • • • 1 • • • • • • AS NOTED AR SGB 07033 1 • • • • • • AUDATA kN A300