MDC
REFLECTED CEILING PLAN D
SCALE; 114 " =1' -0"
EXAM 7
109
1
EQ. EQ.
STORAGE
STORAGE I
STORAGE I
STORAGE
�-
0
112
F 113
114
115
z zS Z m J W
C7- <a
L r
REFLECTED CEILING LEGEND
NOT IN CONTRACT
DENOTES NEW 2'X 2' ACOUSTICAL CEILING TILE: ARMSTRONG, DUNE LAY -IN TILE IN COLOR
WHITE, USE WITH ARMSTRONG 15/16" PRELUDE GRID
-�' • DENOTES DRYWALL CEILING / BULKHEAD
BUILDING STANDARD 2'X 4' THREE -TUBE FLUORESCENT LIGHTING FIXTURE WITH PRISMATIC LEN
(DAYBRITE 2SPG- 332- FS12- UNV- 1 /3EBIOR- LFT735, OR EQUAL)
NOT USED
c❑ NOT USED
FD BUILDING STANDARD 2'X T FLUORESCENT LIGHTING FIXTURE WITH DEEP CELL PRISMATIC LENS
`I'E NOT USED
BUILDING STANDARD 6" RECESSED COMPACT FLUORESCENT FIXTURE
F (DAYBRITE S632PLTU- T6CS- Q1031, OR EQUAL)
D NOT USED
® NOT USED
® DENOTES 2'X 2' SUPPLY GRILLE
DENOTES 2'X 2' RETURN GRILLE
F1_3EX DENOTES EXHAUST GRILLE (TIE INTO BUILDING SYSTEM)
DENOTES STANDARD LIGHT SWITCH
3
DENOTES 3 -WAY LIGHT SWITCH
$D
NOT USED
EMERGENCY LIGHTING WITH BATTERY BACK -UP
(MCPHILBEN CTX6LIZWCSWA, OR EQUAL)
® DIRECTIONAL EXIT SIGN
(MCPHILBEN CXXL3RW, OR EQUAL)
NIGHT LITE
GENERAL REFLECTED CEILING PLAN NOTES
A PAINT NEW GYPSUM BOARD BULKHEADS CEILING WHITE, UNLESS NOTED OTHERWISE.
B THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING HEIGHTS
AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING, AND OTHER
OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT INDICATED. ANY DISCREPANCY SHALL BE
BROUGHT TO THE DESIGNER'S ATTENTION PRIOR TO PERFORMING ANY WORK.
C CEILING HEIGHT THROUGHOUT THE SPACE IS 9' -0" A.F.F., UNLESS NOTED OTHERWISE. CENTER ALL
GRIDS WITHIN ROOM.
D ALL NEW SWITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT CENTER OF
SWITCH 6 " -9" FROM EDGE OF DOOR FRAME, UNLESS NOTED OTHERWISE.
E EXIT SIGNS, DOWN LIGHTS, SPRINKLER HEADS, ETC. SHALL BE CENTERED WITHIN CEILING TILE,
UNLESS NOTED OTHERWISE.
F COLOR OF LIGHT SWITCH DEVICES AND COVERPLATE TO BE IVORY, UNLESS NOTED OTHERWISE.
G ALL MULTIPLE SWITCH LOCATIONS TO BE GROUPED TOGETHER AND LABELED WITH A SINGLE DEVICE
COVERPLATE.
H THERMOSTATS SHALL BE LOCATED DIRECTLY ADJACENT TO LIGHT SWITCH. ALL THERMOSTAT
POSITIONS AND LOCATIONS TO BE COORDINATED WITH THE DESIGNER BEFORE PLACEMENT.
I SUPPLY AND RETURN AIR GRILLES ARE TO BE FLUSH WITH NEW CEILING TILES AND ARE TO BE WHITE
IN COLOR.
J ALL DIMENSIONS ARE TO THE CENTERLINE OF FIXTURE, UNLESS NOTED OTHERWISE.
K IF REQUIRED, ALL CEILING MOUNTED EQUIPMENT LOCATIONS TO BE COORDINATED WITH THE
DESIGNER PRIOR TO INSTALLATION.
L VERIFY ALL SPRINKLER HEAD LOCATIONS. NOTIFY DESIGNER IF ANY DISCREPANCIES OCCUR.
M PROVIDE FIRE DAMPERS AND SMOKE DAMPERS AS REQUIRED PER APPLICABLE BUILDING CODES.
N CEILING IN ALL AREAS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S
SPECIFICATIONS, AND ALL APPLICABLE BUILDING CODES.
0 MECHANICAL CONTRACTOR (MC) TO PRODUCE A DRAWING SHOWING DUCT LAYOUT FROM VAV UNITS
TO DIFFUSERS SHOWN AND THERMOSTAT LOCATIONS. USE VAV BOXES LOCATED WITHIN THE
DEMISED SPACE ONLY. IF ADDITIONAL VAV BOXES ARE REQUIRED, MC TO NOTE ADDITIONAL VAV
BOX(ES) ON LAYOUT DRAWING AND IDENTIFY COST FOR SUPPLYING AND INSTALLING SAID BOX(ES).
P HVAC THERMOSTAT CONTROL FOR ALL ROOMS SHALL BE LOCATED WITHIN DEMISED SUITE. VERIFY
AND REWORK EXISTING DUCTWORK AND THERMOSTATS AS REQUIRED.
Q MECHANICAL CONTRACTOR SHALL VERIFY WORKING CONDITION OF ALL EXISTING THERMOSTATS,
VAV BOXES, EXHAUST FANS, AND ANY OTHER DEVICE DIRECTLY RELATED TO THE HVAC SYSTEM.
CONTRACTOR TO NOTIFY ARCHITECT IMMEDIATELY UPON DISCOVERY OF DEFECTIVE DEVICE.
R MECHANICAL CONTRACTOR TO CONNECT DESIGNATED EXHAUST GRILLES TO EXISTING EXHAUST
SYSTEM.
S SPRINKLER CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING ADEQUATE SPIRNKLER LAYOUT IN
ALL SPACES FORMED BY NEW CONSTRUCTION AS WELL AS ANY EXISTING SPACES RECONFIGURED BY
NEW CONSTRUCTION. LAYOUT MUST MEET ALL APPLICABLE LOCAL AND STATE CODES. REFER TO
SPRINKLER DRAWINGS FOR ALL LOCATIONS OF THAT QEQUIPMENT, EITHER SHOWN OR NOT SHOWN
HERE, AND COORDINATE WITH THE ARCHITECT AND MECHANICAL CONTRACTOR ANY CONFLICTS
DISCOVERED BETWEEN THE SPRINKLER DRAWINGS AND ARCHITECTURAL DRAWINGS.
T FACE OF BULKHEAD TO EXTEND 1" BEYOND FACE OF CASEWORK UNLESS OTHERWISE NOTED.
open
W;
HM DESIGN
1 VYV 1 19Vf� 1 1 1
MERIDIAN STREET
SUITE 100
INDIANAPOLIS
INDIANA 46290
PHONE
317.573.2222
FAX
317.573.2230
INTERIOR DESIGN
ARCHITECTURAL DESIGN
PROGRAMMING
SPACE PLANNING
MOVE MANAGEMENT
CODE COMPLIANCE
CORPORATE IDENTITY
AND BRANDING
DAVID POWERS - ARCHITECT, PC
5816 CARROLTON AVENURE
INDIANAPOLIS, INDIANA 46220
317- 627 -5820 (V)
317- 255 -0468 (F)
• • • • • • •
Wz
wzO W3
W�
�-
0
WWZ01-W
w cn
W
J
z zS Z m J W
C7- <a
L r
V♦
O O
gp�inN�
Z
ZtnO!
W
W_ Z
�_ >�Z�w
aaai0
Lu cz
oWEr -V�
�waw0LL
O 00
w (2 > m N
g�
N
AIL <20
N N
00
<w<Ei6w O
U
t
W
�
Q
�
w
G
W
�--
`
T
Z N
M
< C")
W Q
ZZ
0
�<
Z
O
In
22
LL-
z
W
00
0
_Z
0)
0
0
iL
. • • • • • •
C7
dz
>
mW r
wzO W3
W�
oo-fo
U)W
WWZ01-W
w cn
W
U)CCLL
z zS Z m J W
C7- <a
L r
Z W J
O O
gp�inN�
Z
ZtnO!
zdWOwoX
W_ Z
�_ >�Z�w
aaai0
Lu cz
oWEr -V�
�waw0LL
O 00
w (2 > m N
g�
N
AIL <20
N N
00
<w<Ei6w O
•
DWG SCALE: AS NOTED
DRAWN BY: AB
CHECKED BY: SG
H M D PROJECT #: 07069
• • • • • • •
REFLECTED
CEILING PLAN
A n
iAm