Loading...
HomeMy WebLinkAbout05050050.17PROOF (GRIDS 3, 6, E & F) +(SEE PLAN) ROOF PERIMETER +(SEE PLAN) ,;ATTIC +(SEE PLAN) dSECOND FLOOR +(SEE PLAN) ,iFlRST FLOOR W +(SEE PLAN) ,ikUPPER LEVEL PARKING +(SEE PLAN) SLOWER LEVEL PARKING W +(SEE PLAN) COLUMN MARK COLUMN SCHEDULE C1 I C2 I C2A I C3 I C4 I C5 I C6 I C7 I C8 I C9 I C10 I C10A I C10B I C11 I C11A I C12 I C13 I C14 I C15 BASEPLATE 11Y4 "X16 "x14" 11Y4 "x16 "x14" 11Yi x16 "x14" I lWx16 "x14" ANCHOR RODS 1 (4) 3/4" AR 1 (4) 3/4' AR 1 (4) 3/4" AR 1 (4) 3/4" AR COLUMN SCHEDULE NOTES: 1. See typical details for column base construction. 1 Wx16 "x14" 11% "x16 "x14" 11% "x16 "x14" 11 % "x16 "x14" 11 Yz "x16 "x14" 11 Wx16 "x16" 11Wx16"x16" 1 116 "x16 "x16" (4) 3/4" AR I (4) 3/4" AR I (4) 3/4" AR I (4) 3/4" AR I (4) 3/4" AR I (4) 1" AR I (4) 1" AR I (4) 1" AR 1 WX16 "x2O" 1 Wx14 "x9" 1142 "X16 "X16" 1116006%16" SEE 6/S404 SEE x /S4xx (4) 1" AR (4) V4" A325 (4) 1" AR (4) 1" AR V4 x10 "x10" V4 x7 "x6" V4 "X12 "x7" SEE 8/S407 SEE X /S4XX SEE X /S4XX FIELD WELD (3) 3/4" AR SEE X /S4XX (4) 3/4" A325 STEEL BEAM TO CONCRETE COLUMN OR WALL CONNECTION SCHEDULE SIZE REMARKS (50 KSI BEAMS ONLY) F4.0 4' -0" MARK BEAM No. ROWS WELD A 4' -6" ANGLE ANGLE (8) #5 EW EMBED PLATE CAPACITY KIPS CONCRETE x 14" (8) #5 EW (SEE BELOWTE 5 OF BOLTS SIZE x 16" SIZE (6) LENGTH 6' -0" x 6' -0" H() (8) 15 EW T() No. STUDS x 6' -6" x 18" (10) #5 EW F•O 7' -0" x 7' -0" x 20" (11) #5 EW F7•5 7' -6" x 7' -6" x 22" (10) #6 EW 4 KSI 3 KSI EP -A C8, W8, W10 2 M6 L4x3x-% 5142 9 %" 4 18.3 18.3 EP -B W12x14 3 M6 L4x3x% 8142 13 %" 6 33 33 EP -B W12x16 -W14 3 M6 L4x3x-% 814i 13 %" 6 40.3 40.3 EP -C W16, W18 4 M6 L4x3x-% 11Th 17 %" 8 58.4 58.4 EP -D W21 5 X46 1-43xZ% 14142 21 %" 10 91.5 86 EP -E W24 6 his L4x3x-% 17M2 25 %" 12 111 105 EP -F W27 7 Y4 L4x3xM6 20142 29 %" 14 125 124 EP -G W30 8 144 1-400% 23Ys 33 %" 16 148 142 EP -G W33 9 Y4 L430iie 261,1 33 %" 16 167 142 EP -H W36, W40 10 144 1-43xM6 2916 37 %" 16 186 161 F/ CONC WALL OR CONC COLUMN NOTES: 1. PLATE AND ANGLE MATERIAL ASTM A36. 2. BEAM MATERIAL PER GENERAL NOTES. 'A' 1" RETURN 3. FOR BEAM REACTIONS, SEE FRAMING PLANS. SHOULD T & B TYP INDICATED REACTIONS EXCEED TABLE CAPACITIES FABRICATOR S T STL BM EL 1 T 4. SHALL PROVIDE CONNECTION DETAIL. BEAM WEB CAPACITY REQUIRES VERIFICATION FOR BEAM'S WITH ASTM A36 MATERIAL SEE PLAN 5. UNO ON PLAN OR IF REACTION EXCEEDS TABULATED VALUE, USE THIS CONNECTION AS TYPICAL FOR LISTED BEAM SIZES. -- _ - -- r>= == 6. GALVANIZE PLATE AND ANGLE MATERIAL AT ALL EXTERIOR CONDITIONS. 6" LG HS EMBEDDED PLATE DETAIL 4"0 A325N BOLTS IN DBL L4x3xTHICKNESS INDICATED IN SCHEDULE, TYP. PROVIDE 'Me "x1142" HORIZ SLOTS IN BEAM WEB AND INSTALL NUTS. "FINGERTIGHT" AND PEEN THREADS OR PROVIDE ADDITIONAL LOCKNUT. COLUMN FOOTING SCHEDULE MARK SIZE SIZE REMARKS REINFORCEMENT F4.0 4' -0" x 4' -0" x 12" (7) #5 EW F4.5 4' -6" x 4' -6" x 12" (8) #5 EW F5.0 5' -0" x 5' -0" x 14" (8) #5 EW F5.5 5' -6" x 5' -6" x 16" (8) #5 EW F6.0 6' -0" x 6' -0" x 18" (8) 15 EW F6.5 6' -6" x 6' -6" x 18" (10) #5 EW F•O 7' -0" x 7' -0" x 20" (11) #5 EW F7•5 7' -6" x 7' -6" x 22" (10) #6 EW F8.0 8' -0" x 8' -0" x 22" (10) #6 EW wwmn rwllNu btmLUULL NUlt_v 1. Provide 3" concrete cover on bars. 2. Use concrete brick or CRSI Class 3, CHCP wire bar supports at 3' -0 ". PIER SCHEDULE MARK SIZE REINFORCEMENT REMARKS P2020 20" x 20" (8) #fi VERT 2' -6" x 12" (3) #5 Cont WF36 3' -0" x 14" ALL EMBED LOCATIONS P2412 24" x 12" (6) #6 VERT ALL 5' -0" x 20" (8) #5 Cont, #5 0 12" Trans DOUBLE LAYER EMBED LOCATIONS P2022 20" x 22" (8) #6 VERT 12- O DOUBLE LAYER ALL EMBED LOCATIONS P2620 26" x 20" (8) #6 VERT 12. OC A ALL EMBED OONS rICR Jtd7C1JULt NV ILW 1. Provide %* concrete cover over ties. 2. See typical pier elevation for tie and vertical bar placement. 3. Where pier is extended from wall see 14/S404 for reinforcing tie into wall. 4. Provide CRSI Typ Bar Bend No T5 ties for all veritcal face bars, if there are more than four vertical bars in the pier. WALL FOOTING SCHEDULE MARK SIZE (W x D) REINFORCEMENT WF24 " " 2 -0 x 12 (3) 15 Cont WF30 2' -6" x 12" (3) #5 Cont WF36 3' -0" x 14" (4) #5 Cont WF36A 3' -0" x MATCH EXISTING (4) #5 Cont WF60 5' -0" x 20" (8) #5 Cont, #5 0 12" Trans BALL rwI=7 N6mtVVLL NVILS: 1. Provide 3" concrete cover on bars. 2. Use concrete brick or CRSI Class 3, CHCP wire bar supports at 3' -0 ". MASONRY WALL SCHEDULE MARK TYPE REINFORCING VERTICAL MW8 8" CMU #5 ® 48" OC #5 ® 24" OC 0 ELEVATOR WALLS 0 10" CMU 1 #5 ® 48" OC MP.-AMK T nw.L ZAALOULt NU ILS: 1. Grout all cores with rebar solid, unless noted otherwise. 2. Reinforcing steel in bond beams shall be continuous across control joints unless noted otherwise. BRICK LINTEL SCHEDULE FOR ALL LINTELS NOT INDICATED ON PLANS CLEAR OPENING STEEL ANGLE Up to 5' -0" L3Xx3Xx9i6 5' -1" to 7' -0" L 5 x 3h x 9(6 (LLV) 7' -1" to 10' -0" L 6 x 3h x % (LLV) I Tr UM- 13191UA UN ItL JllitUULL NU ILS: 1. All lintels shall have 8" bearing at each end. 2. All exterior lintels shall be galvanized. 3. All interior lintels shall be shop primed with two coats of epoxy paint. CONCRETE WALL SCHEDULE MARK THICKNES S REINFORCING REMAKE HORIZ VERT DOWELS CW8 8" #4 ® 12" #4 ® 12" #4 ® 12" SINGLE LAYER CW12 12" 1 #5 ® 12" #5 0 12" #5 ® 12" DOUBLE LAYER CW16 16" #5 ® 8" #5 ® 12" #5 ® 12" DOUBLE LAYER WIM.At I C WALL NALUULt NU I t5: 1. Single layer bars shall be placed in the center of the wall. 2. Double layer bars shall have 114" cover on both sides of wall, uno 3. Provide wheel spacers or CRSI Typ Bar Bend No T5 at 3' -0" each way to assure adequate concrete cover. 4. See sections for all bars not included in schedule. PEDCOR DESIGN GROUP Architecture / Project Managment: 335 Ridgepoint Drive Cannel, Indiana 46032 317.705.7979 (phone) 317.705.7980 (fax) Engineer: C. Rodney McComas pNEY 7C No. �. 860325 0. STATE OF •./ND I AUK• '' \��� ANA.. MoCOMAS C UJI lN E ERING; STRUCI1RAl 6111 FORDr9C MfW NA7MAL CO MTANnS 1717 Ead lift Sind. Su1b 200 Camd, kWk m X0032 317-380 -6102 scan 317 -SU-OM F= Developer: P E D C 0 R DEVELOPMENT CO. U) Project: W U O� m W o 06 CU �Z Q Q� �o C z �; C�( w� V � U U N m d O U D W U) d Issue Date Drawn By Checked By 02/28/05 njh All Revisions: MEI Project Number: 24187 Sheet Title: Schedules Sheet Number: