HomeMy WebLinkAbout05050050.7ABBREVIATIONS LIST
AR
ANCHOR RODS
MEZZ
MEZZANINE
ABV
ABOVE
MFR
MANUFACTURER
ACI
AMERICAN CONCRETE INSTITUTE
MIN
MINIMUM
ADD'L
ADDITIONAL
MISC
MISCELLANEOUS
ADH
ADHESIVE
MO
MASONRY OPENING
ADJ
ADJACENT
MOM
MOMENT
AESS
ARCHITECTURALLY EXPOSED
MSW
MASONRY SHEAR WALL
Dead Load:
STRUCTURAL STEEL
MSL
MEAN SEA LEVEL
AFF
ABOVE FINISHED FLOOR
MTL
METAL
AGGR
AGGREGATE
MW
MASONRY WALL
AHU
AIR HANDLING UNIT
NIC
NOT IN CONTRACT
AISC
AMERICAN INSTITUTE OF
NO
NUMBER
Flat Roof Snow Load:
STEEL CONSTRUCTION
NS
NEAR SIDE
AISI
AMERICAN IRON AND
NTS
NOT TO SCALE
Thermal Factor:
STEEL INSTITUTE
0/0
OUT TO OUT
ALUM
ALUMINUM
OA
OVERALL
ALT
ALTERNATE
OC
ON CENTER
APA
AMERICAN PLYWOOD ASSOCIATION
OD
OUTSIDE DIAMETER
APPROX
APPROXIMATE
OF
OUTSIDE FACE
ARCH
ARCHITECT
OPNG
OPENING
ARCH'L
ARCHITECTURAL
OPP
OPPOSITE
ASTM
AMERICAN SOCIETY OF
OPP HD
OPPOSITE HAND
TESTING MATERIALS
OSB
ORIENTED STRAND BOARD
AWS
AMERICAN WELDING SOCIETY
OSL
OUTSTANDING LEG
L
ANGLE
OVS
OVERSIZE HOLE
BAL
BALANCE
PAF
POWDER ACTUATED FASTENER
B/B
BACK TO BACK
PC
PRECAST
BC
BOTTOM CHORD
PL
PLATE
BD
BOARD
PLF
POUNDS PER LINEAR FOOT
BLDG
BUILDING
PLYWD
PLYWOOD
BLK
BLOCK
PNL
PANEL
BLW
BELOW
PROJ
PROJECTION
BM
BEAM
PSF
POUNDS PER SQUARE FOOT
BOTT
BOTTOM
PSI
POUNDS PER SQUARE INCH
BP
BEARING PLATE
PSL
PARALLEL STRAND LUMBER
BRDG
BRIDGING
PT
PRESSURE TREATED
BRG
BEARING
PTN
PARTITION
BRK
BRICK
PVMT
PAVEMENT
BS
BOTH SIDES
R
RADIUS
BSMT
BASEMENT
RD
ROOF DRAIN
BTWN
BETWEEN
REF
REFERENCE
C
CAMBER
REINF
REINFORCE(D) (ING) (MENT)
C/C
CENTER TO CENTER
REQ'D
REQUIRED
CANT
CANTILEVER
REV
REVISION /REVISED
CAIS
CAISSON
RO
ROUGH OPENING
CFS
COLD FORMED STEEL
RRD
ROOF RELIEF DRAIN
CJ
CONTROL AND OR
RTN
RETURN
CONSTRUCTION JOINT
RTU
ROOF TOP UNIT
CL
CENTERLINE
RW
RETAINING WALL
CLR
CLEAR
SCHED
SCHEDULE
CMU
CONCRETE MASONRY UNIT
SECT
SECTION
COL
COLUMN
SHT
SHEET
COORD
COORDINATE
SIM
SIMILAR
COMP
COMPACTED
Si
SAWCUT JOINT
CONC
CONCRETE
SJI
STEEL JOIST INSTITUTE
CONN
CONNECTION
SL
SLOPED
CONST
CONSTRUCTION
SPA
SPACE(S)
CONT
CONTINUOUS
SPECS
SPECIFICATIONS
CONTR
CONTRACTOR
SQ
SQUARE
CTR
CENTER
SS
STAINLESS STEEL
CTR'D
CENTERED
SSL
SHORT SLOTTED HOLES
DIA
DIAMETER
STD
STANDARD
DIAG
DIAGONAL
STIFF
STIFFENERS
DIM
DIMENSION
STL
STEEL
DL
DEAD LOAD
STRUCT
STRUCTURAL
DLT
DEEP LEG TRACK
SYMM
SYMMETRICAL
DO
DITTO
TdB
TOP AND BOTTOM
DN
DOWN
T&G
TONGUE AND GROOVE
DTL
DETAIL
TC
TOP CHORD
DWG
DRAWING
TEMP
TEMPERATURE
DWL
DOWEL
TF
TRENCH FOOTING
EA
EACH
THK
THICK
EE
EACH END
THKS
THICKENED SLAB
EF
EACH FACE
THR'D
THREADED
EJ
EXPANSION JOINT
TL
TOTAL LOAD
ENG
ENGINEER
TOP'G
TOPPING
ELEV
ELEVATION
TRANS
TRANSVERSE
ELECT
ELECTRICAL
TYP
TYPICAL
EOD
EDGE OF DECK
UNO
UNLESS NOTED OTHERWISE
EOS
EDGE OF SLAB
VERT
VERTICAL
EQ
EQUAL
VIF
VERIFY IN FIELD
EQUIV
EQUIVALENT
w/
WITH
ES
EACH SIDE
WD
WOOD
EW
EACH WAY
WD
WINDOW OPENING (MASONRY)
EXIST -EX
EXISTING
WP
WORKING POINT
EXP
EXPANSION
WT
WEIGHT
EXT
EXTERIOR
WWF
WELDED WIRE FABRIC
F/
FACE OF
FD
FLOOR DRAIN
ELEVATION
TOP AND
FDN
FOUNDATION
BOTTOM OF LIST
FIN
FINISH
T/
ELEVATION, TOP OF
FLR
FLOOR
B/
ELEVATION, BOTTOM OF
FLG
FLANGE
T /BB
TOP OF BOND BEAM
FS
FARSIDE
T /BM
TOP OF BEAM
FTG
FOOTING
T /CONC
TOP OF CONCRETE
GA
GAUGE
T/F
TOP OF FOOTING
GALV
GALVANIZED
T /LDG
TOP OF LEDGE
GB
GRADE BEAM
T/MAS
TOP OF MASONRY
GC
GENERAL CONTRACTOR
T/P
TOP OF PIER
GL
GLULAM
T /SLAB
TOP OF SLAB
GR
GRADE
T /STL
TOP OF STEEL
HC
HOLLOW CORE
T/W
TOP OF WALL
HD
HOLD DOWN
T /GB
TOP OF GRADE BEAM
HGT
HEIGHT
T /CAIS
TOP OF CAISSON
HI
HIGH
B /PL
BOTTOM OF PLATE
HK
HOOK
B/F
BOTTOM OF FOOTING
HORIZ
HORIZONTAL
HP
HIGH POINT
SYMBOLS
HS
HEADED STUD
DIAMETER
HSS
HOLLOW STRUCTURAL SECTION
DEGREE
ID
INSIDE DIAMETER
ELEVATION
IF
INSIDE FACE
INFO
INFORMATION
f
PLUS OR MINUS
INT
INTERIOR
INV
INVERT
JST
JOIST
JT
JOINT
K
KIP
KO
KNOCK OUT
LB
POUND
LDG
LEDGE
LG
LONG
LL
LIVE LOAD
LLH
LONG LEG HORIZONTAL
LLV
LONG LEG VERTICAL
LNTL
LINTEL
LSL
LONG SLOTTED HOLES
LONG
LONGITUDINAL
LP
LOW POINT
LVL
LAMINATED VENEER LUMBER
MAS
MASONRY
MAT'L
MATERIAL
MAX
MAXIMUM
MBM
METAL BUILDING MFR
MCJ
MASONRY CONTROL JT
MECH
MECHANICAL
STRUCTURAL STEEL NOTES
SS1. All structural steel shall conform to the following:
W Shapes A992, Grade 50.
Angles, Channels, Plates, Bars ASTM A36 (Fy =36 ksi)
HSS Tubes ASTM A500, Grade B (Fy =46 ksi)
HSS Pipes ASTM A500, Grade B (Fy =42 ksi)
Anchor Rods ASTM F1554, Grade 36
SS2. All steel shall be detailed, fabricated and erected in accordance with AISC "LOAD & RESISTANCE
FACTOR DESIGN FOR STRUCTURAL STEEL BUILDINGS" and the "CODE OF STANDARD
COL MARK, SEE SCHEDULE FOR PRACTICE", Third Edition.
ACTUAL SIZE, BASE PLATE AND SS3. All bolted connections shall be made with 3/4" diameter, A325 bolts with nuts and washers, unless
ANCHOR RODS otherwise noted. All connections shall be shear bearing connections tightened to snug -tight condition,
unless otherwise noted. All connections shall conform to the LRFD SPECIFICATION FOR STRUCTURAL
P16 = PIER, SEE SCHEDULE P16 JOINTS USING ASTM A325 OR A490 BOLTS.
T/P =TOP OF PIER ELEV
T/P - (0' -8') ��` I I SS4. All shop and field welds shall be made using E70 electrodes or equivalent.
F40 =COL FTG MARK SEE SCHED F40 G,S I SS5. All headed concrete anchors shall be ASTM Al 08 (Fy =50 ksi), 3/4" diameter x 4" after welding, unless
T/F = TOP OF FTG ELEV T/F -(2'-81 °1 I I _ i noted otherwise.
POCHE INDICATES r ° I I v SS6. Steel fabricator shall obtain the size and location of all openings for grilles, louvers, etc. before proceeding
LIMITS OF SLAB - I with the fabrication and erection of any required frames.
DEPRESSION L _ jI SS7. Provide Heckman #129 and #130 channel slot and channel slot anchors at all columns that abut masonry
walls, unless noted.
CONCRETE MASONRY UNIT WALL (MW)- I I SS8. Provide temporary bracing of the structure until all permanent lateral support is in place.
T SLAB SEE SCHED FOR SIZE AND REINF I SS9. Structure Stability: The entire roof andlor floor decking materials must be fully erected and connected to
- (0' -6 ") I HATCH REPRESENTS the supporting steel before temporary, erection bracing is removed.
MASONRY WALL
T/W = TOP OF WALL ELEV
INDICATES TOP OF I
CONC SLAB CONCRETE WALL (CW), SEE SCHEDULE
FOR WALL THICKNESS AND REINF
-- ------- - - - - -� -L- T/W_(0_ -8") J I
-- J
�- - - - - - - - - - - - Z - 7WF24 T/F - (2' -8 ") 1/8400
CONCRETE WALL FTG (WF), SEE SCHED
FOR FTG SIZE AND REINF INDICATES PLAN DETAIL
T/F = TOP OF FTG ELEV
SECTION CUT COL GRID, COLUMNS CENTERED ON
GRID INTERSECTIONS, UNO
FOUNDATION PLAN LEGEND
SCALE: NTS
COL GRID, COLUMNS CENTERED ON
GRID INTERSECTIONS, UNO
BEAM CAMBER --r�M
NUMBER OF SHEAR STUDS----*--("
X
N
�J
INDICATES JOIST SIZE
2/S400
INDICATES PLAN DETAIL)
TOP OF JOIST GIRDER ELEV -�'N;
JOIST GIRDER SIZE +
t2
co
CD
co
HORIZ BRIDGING
"X" BRIDGING J
MOMENT CONNECTION
9
EDGE OF DECK,
CONT PERMITER ANGLE
¢ °w W1422
LO
Y
00
+(22' -11 ")
't?
+(23'-11')
a
a o
rn
Y ?
k o
Cq
Z X
32LH12-+
OPENING THRU
DECK AND FRAMING
INDICATES SECTION CUT
TOP OF STL ELEV
0
UNFACTORED REACTION IN
KIPS, IF NO REACTION IS
SHOWN DESIGN FOR 6 KIPS
-TOP OF STL ELEV
BEAM SIZE
JOIST SIZE
\ �
v INDICATES KNEE BRACE
m
/\ Y
r \\ W14x22 +(24' -0 ")
ELEVATION
INDICATES BRACING
1/S500
INDICATES FRAMING ELEVATION
FRAMING PLAN LEGEND
SCALE: NTS
STEEL JOISTS NOTES
SJ1. Provide all joists, bridging and accessories for the complete erection of joists in accordance with the
current Steel Joist Institute "STANDARD SPECIFICATIONS AND LOAD TABLES FOR OPEN WEB
STEEL JOISTS AND JOIST GIRDERS" and Underwriters Laboratories "STANDARD, FIRE TESTS OF
BUILDING CONSTRUCTION AND MATERIALS ".
SJ2. Bridging shall be completely erected and joists aligned before any construction loads are placed on joists.
SJ3. Do not weld bottom chord of joists to columns unless noted on drawings.
SJ4. Install erection bolts at all joist girder to column and joist to column connections.
SJ5. Where ballasted roofing is not shown on architectural drawings, provide uplift bridging at all joists as per
"STANDARD SPECIFICATIONS AND LOAD TABLES FOR OPEN WEB STEEL JOISTS AND JOIST
GIRDERS" for a net uplift load of 12 psf.
STEEL DECK NOTES
MD1. All metal deck material, fabrication and installation shall conform to Steel Deck Institute" SDI
SPECIFICATIONS AND COMMENTARY" and "CODE OF RECOMMENDED STANDARD PRACTICE ",
Current edition, unless noted.
MD2. Roof deck shall be welded using a 36/4 pattern with (1) #10 TEK sidelap fastener unless otherwise shown
in typical detail.
MD3. Provide TS 2 1/2x 2 1 /2x 1/8 deck support, field welded to joist or beam at all deck span changes.
MD4. Provide L3x3xl /4 deck support at all columns where required, unless noted.
MD5. Provide 20 gauge cover plate at all roof deck span changes.
MD6. Provide L3x3xl /4 at all unsupported edges of deck and around roof perimeter, unless otherwise noted.
MD7. All deck shall be provided in a minimum of 3 -span lengths where possible.
MD8. Where ballasted roofing is not shown, provide uplift bridging at all joists as per "STANDARD
SPECIFICATIONS AND LOAD TABLES FOR OPEN WEB STEEL JOISTS AND JOIST GIRDERS" for a
net uplift load of 12 psf.
SAWN LUMBER NOTES
W1. All wood shall be as follows:
2x4,2x6,2x8 - Spruce, Pine,Fir(SPF), #2, Kiln -Dried or Southern Pine, #2. All other sizes - Southern Pine,
#2, Kiln -Dried as noted on plan or in sections.
W2. All wood, connections and erection shall be in conformance with the current edition of NFPA National
Design Specification.
W3. All connectors shall be Simpson Strong -Tie, galvanized,unless otherwise approved by McComas
Engineering.
W4. All bolts, washers and nuts shall be carbon steel, unless noted.
W5. All nails to be common type or building department approved equal.
W6. All sill plates in contact with concrete or masonry shall be treated with preservative treatment uno in
sections.
W7. Attach all top plates and sill plates to studs with (2) 16d nails.
WOOD SHEATHING NOTES
WS1. All wood sheathing shall be 5/8" min. thickness APA rated 40/20, Exposure 1. Plywood shall conform to
the latest revision product standard PS 1.
WS2. All sheating shall have long dimension perpendicular to supports, staggered joints. Provide 1/8" gap for all
sheathing joints. Provide panel clips for all roof sheathing.
WS3. Space all nails 3/8" minimum from panel or supporting member edge. Nails to penetrate supporting
members by 1 -5/8" minimum.
WS4. Edge of openings through roofs or walls shall be nailed per boundary nailing requirments indicated in
typical detail.
WS5. See architectural roof plan to establish all elevations, openings, equipment and other requirements not
indicated on structural drawings.
WS4. All nails to be common type or building department approved equal.
HOLLOW CORE PLANK NOTES
HCP1. All plank designs are to accommodate toppings and all uniform, concentrated, and partition line loads
superimposed on the plank system.
HCP2. Strand pattern requirements are to be determined by the plank design engineer.
HCP3. Planks are to be designed to the latest design standards of the Precast Concrete Institute and the
American Concrete Institute ACI 318 -99.
HCP4. Minimum material properties:
28 day strength of concrete, fc= 5,000 psi. 6% Air.
Reinforcing Steel: ASTM A -615 grade 60.
Tendons: ASTM A416 low relaxation strands.
See plan notes for topping and related materials notes.
HCP5. Limit camber prior to superposition of loads to 112 ".
HCP6. All planks shall include edges suitable for grouted shear keys for deflection compatibility, and block -outs
for plumbing and column interfaces as shown on plans.
HCP7. Submittals are to include dimensioned plank layout and shop drawings, calculations including predicted
camber at erection time and long term camber under sustained dead and live loads. All calculations are
to be signed and sealed by a professional engineer licensed to practice in the state of Indiana.
STEEL GRATING NOTES
SG1. All grating shall be 19 -W-4, Heavy Duty steel.
SG2. Bearing bar size shall be 1 1/2" x 1/4 ", spacing = 1 1/16" c -c., unless noted.
SG3. Cross bars shall be 4" c -c.
SG4. Grating panels shall be anchored to each supporting member with a minimum of (2) manufacturer
standard clips uno on plans or in sections.
SG5. Finish for interior grating shall be manufacturer's standard paint, finish for exterior grating shall be
galvanized unless otherwise noted.
SG6. All grating panels to be trim banded.
STEEL STAIR NOTES
SST1. All Steel stairs & landings shall be designed and fabricated per project specifications and architectural
plans.
SST2. All stairs & landings shall be designed for 100 psf live load.
SST3. Handrails and guardrails are to be designed for lateral loads prescribed in IBC2000.
SST4. Stair support connections to structural framing are to be detailed by stair designer.
SST5. All stair treads shall be 19 -W -4, Heavy Duty steel, unless noted.
SST6. Stair tread bearing bar size shall be 1 114" x 1/4 ", spacing = 1 1/16" c-c.
SST7. Stair tread cross bars shall be 4" c -c.
SST8. Nosing shall be cast aluminum abrasive provided at the head of all stairs and on stair treads.
SST9. Stair tread grating to be serrated.
SST10. Stair tread grating finish to be manufacture's standard paint.
MASONRY AND REINFORCED MASONRY NOTES
M1. Minimum 28 day compressive strength of concrete masonry units shall be 2800 p.s.i. based on net area
of the unit. Specified design compressive strength of masonry shall be fm = 2000 p.s.i. All units for
exterior walls, load- bearing walls and shear walls shall be normal weight block.
M2. All mortar shall be Type S. No admixtures may used unless approved by architect/engineer. Mortar shall
not be used for grouting cores or filling bond beams.
M3. All block shall be layed in a running bond pattern.
M4. Course grout shall be used were grouting is required. Slump shall be 8" +/- 1 ". Minimum grout
compressive strength shall be 3000 p.s.i.
M5. All reinforcing shall be ASTM A615 Grade 60 (Fy =60 ksi). Lap all reinforcing a minimum of 48 bar
diameters.
M6. See architectural and specifications for all control joint locations. Reinforcing in bond beams shall be
discontinuous at control joints.
M7. Provide ladder type horizontal joint reinforcement at 16" o.c. Side rods and cross rods shall be #9 wire,
galvanized, see specifications. Cut joint reinforcement at control joints.
M8. Provide "L" bars at all bond beam comers as required.
M9. Fill cores of block solid with grout two full courses below the bearing of all beams or lintels supported on
masonry.
M10. All attachments to block shall be made with Hilti HX 1/2" diameter x 3" sleeve anchors, unless noted
otherwise. Anchors shall be installed per manufacturer's recommendations.
M 11. See typical schedules for masonry and steel lintels not indicated on plans.
M12. All masonry units below grade to be grouted solid.
M13. Provide ties to all structural steel.
M 14. All interior, non -load bearing masonry walls over 12' -0" high, shall be supported on thickened slab as per
typical detail. Wall vertical reinforcing shall be #5 @ 48" OC full height. Unless noted otherwise.
M15. All cores with reinforcing steel shall be grouted solid, full height of wall.
GENERAL NOTES
G1. BUILDING CODES:
J
Code 2000
Local: Indiana Building Code 2003
C
Concrete: American Concrete Institute, 318 -99.
G2. DESIGN LOADS:
+
_
N
19 psf
Live Load:
25 psf
MECHANICAL ROOF
't?
+(23'-11')
a
a o
rn
Y ?
k o
Cq
Z X
32LH12-+
OPENING THRU
DECK AND FRAMING
INDICATES SECTION CUT
TOP OF STL ELEV
0
UNFACTORED REACTION IN
KIPS, IF NO REACTION IS
SHOWN DESIGN FOR 6 KIPS
-TOP OF STL ELEV
BEAM SIZE
JOIST SIZE
\ �
v INDICATES KNEE BRACE
m
/\ Y
r \\ W14x22 +(24' -0 ")
ELEVATION
INDICATES BRACING
1/S500
INDICATES FRAMING ELEVATION
FRAMING PLAN LEGEND
SCALE: NTS
STEEL JOISTS NOTES
SJ1. Provide all joists, bridging and accessories for the complete erection of joists in accordance with the
current Steel Joist Institute "STANDARD SPECIFICATIONS AND LOAD TABLES FOR OPEN WEB
STEEL JOISTS AND JOIST GIRDERS" and Underwriters Laboratories "STANDARD, FIRE TESTS OF
BUILDING CONSTRUCTION AND MATERIALS ".
SJ2. Bridging shall be completely erected and joists aligned before any construction loads are placed on joists.
SJ3. Do not weld bottom chord of joists to columns unless noted on drawings.
SJ4. Install erection bolts at all joist girder to column and joist to column connections.
SJ5. Where ballasted roofing is not shown on architectural drawings, provide uplift bridging at all joists as per
"STANDARD SPECIFICATIONS AND LOAD TABLES FOR OPEN WEB STEEL JOISTS AND JOIST
GIRDERS" for a net uplift load of 12 psf.
STEEL DECK NOTES
MD1. All metal deck material, fabrication and installation shall conform to Steel Deck Institute" SDI
SPECIFICATIONS AND COMMENTARY" and "CODE OF RECOMMENDED STANDARD PRACTICE ",
Current edition, unless noted.
MD2. Roof deck shall be welded using a 36/4 pattern with (1) #10 TEK sidelap fastener unless otherwise shown
in typical detail.
MD3. Provide TS 2 1/2x 2 1 /2x 1/8 deck support, field welded to joist or beam at all deck span changes.
MD4. Provide L3x3xl /4 deck support at all columns where required, unless noted.
MD5. Provide 20 gauge cover plate at all roof deck span changes.
MD6. Provide L3x3xl /4 at all unsupported edges of deck and around roof perimeter, unless otherwise noted.
MD7. All deck shall be provided in a minimum of 3 -span lengths where possible.
MD8. Where ballasted roofing is not shown, provide uplift bridging at all joists as per "STANDARD
SPECIFICATIONS AND LOAD TABLES FOR OPEN WEB STEEL JOISTS AND JOIST GIRDERS" for a
net uplift load of 12 psf.
SAWN LUMBER NOTES
W1. All wood shall be as follows:
2x4,2x6,2x8 - Spruce, Pine,Fir(SPF), #2, Kiln -Dried or Southern Pine, #2. All other sizes - Southern Pine,
#2, Kiln -Dried as noted on plan or in sections.
W2. All wood, connections and erection shall be in conformance with the current edition of NFPA National
Design Specification.
W3. All connectors shall be Simpson Strong -Tie, galvanized,unless otherwise approved by McComas
Engineering.
W4. All bolts, washers and nuts shall be carbon steel, unless noted.
W5. All nails to be common type or building department approved equal.
W6. All sill plates in contact with concrete or masonry shall be treated with preservative treatment uno in
sections.
W7. Attach all top plates and sill plates to studs with (2) 16d nails.
WOOD SHEATHING NOTES
WS1. All wood sheathing shall be 5/8" min. thickness APA rated 40/20, Exposure 1. Plywood shall conform to
the latest revision product standard PS 1.
WS2. All sheating shall have long dimension perpendicular to supports, staggered joints. Provide 1/8" gap for all
sheathing joints. Provide panel clips for all roof sheathing.
WS3. Space all nails 3/8" minimum from panel or supporting member edge. Nails to penetrate supporting
members by 1 -5/8" minimum.
WS4. Edge of openings through roofs or walls shall be nailed per boundary nailing requirments indicated in
typical detail.
WS5. See architectural roof plan to establish all elevations, openings, equipment and other requirements not
indicated on structural drawings.
WS4. All nails to be common type or building department approved equal.
HOLLOW CORE PLANK NOTES
HCP1. All plank designs are to accommodate toppings and all uniform, concentrated, and partition line loads
superimposed on the plank system.
HCP2. Strand pattern requirements are to be determined by the plank design engineer.
HCP3. Planks are to be designed to the latest design standards of the Precast Concrete Institute and the
American Concrete Institute ACI 318 -99.
HCP4. Minimum material properties:
28 day strength of concrete, fc= 5,000 psi. 6% Air.
Reinforcing Steel: ASTM A -615 grade 60.
Tendons: ASTM A416 low relaxation strands.
See plan notes for topping and related materials notes.
HCP5. Limit camber prior to superposition of loads to 112 ".
HCP6. All planks shall include edges suitable for grouted shear keys for deflection compatibility, and block -outs
for plumbing and column interfaces as shown on plans.
HCP7. Submittals are to include dimensioned plank layout and shop drawings, calculations including predicted
camber at erection time and long term camber under sustained dead and live loads. All calculations are
to be signed and sealed by a professional engineer licensed to practice in the state of Indiana.
STEEL GRATING NOTES
SG1. All grating shall be 19 -W-4, Heavy Duty steel.
SG2. Bearing bar size shall be 1 1/2" x 1/4 ", spacing = 1 1/16" c -c., unless noted.
SG3. Cross bars shall be 4" c -c.
SG4. Grating panels shall be anchored to each supporting member with a minimum of (2) manufacturer
standard clips uno on plans or in sections.
SG5. Finish for interior grating shall be manufacturer's standard paint, finish for exterior grating shall be
galvanized unless otherwise noted.
SG6. All grating panels to be trim banded.
STEEL STAIR NOTES
SST1. All Steel stairs & landings shall be designed and fabricated per project specifications and architectural
plans.
SST2. All stairs & landings shall be designed for 100 psf live load.
SST3. Handrails and guardrails are to be designed for lateral loads prescribed in IBC2000.
SST4. Stair support connections to structural framing are to be detailed by stair designer.
SST5. All stair treads shall be 19 -W -4, Heavy Duty steel, unless noted.
SST6. Stair tread bearing bar size shall be 1 114" x 1/4 ", spacing = 1 1/16" c-c.
SST7. Stair tread cross bars shall be 4" c -c.
SST8. Nosing shall be cast aluminum abrasive provided at the head of all stairs and on stair treads.
SST9. Stair tread grating to be serrated.
SST10. Stair tread grating finish to be manufacture's standard paint.
MASONRY AND REINFORCED MASONRY NOTES
M1. Minimum 28 day compressive strength of concrete masonry units shall be 2800 p.s.i. based on net area
of the unit. Specified design compressive strength of masonry shall be fm = 2000 p.s.i. All units for
exterior walls, load- bearing walls and shear walls shall be normal weight block.
M2. All mortar shall be Type S. No admixtures may used unless approved by architect/engineer. Mortar shall
not be used for grouting cores or filling bond beams.
M3. All block shall be layed in a running bond pattern.
M4. Course grout shall be used were grouting is required. Slump shall be 8" +/- 1 ". Minimum grout
compressive strength shall be 3000 p.s.i.
M5. All reinforcing shall be ASTM A615 Grade 60 (Fy =60 ksi). Lap all reinforcing a minimum of 48 bar
diameters.
M6. See architectural and specifications for all control joint locations. Reinforcing in bond beams shall be
discontinuous at control joints.
M7. Provide ladder type horizontal joint reinforcement at 16" o.c. Side rods and cross rods shall be #9 wire,
galvanized, see specifications. Cut joint reinforcement at control joints.
M8. Provide "L" bars at all bond beam comers as required.
M9. Fill cores of block solid with grout two full courses below the bearing of all beams or lintels supported on
masonry.
M10. All attachments to block shall be made with Hilti HX 1/2" diameter x 3" sleeve anchors, unless noted
otherwise. Anchors shall be installed per manufacturer's recommendations.
M 11. See typical schedules for masonry and steel lintels not indicated on plans.
M12. All masonry units below grade to be grouted solid.
M13. Provide ties to all structural steel.
M 14. All interior, non -load bearing masonry walls over 12' -0" high, shall be supported on thickened slab as per
typical detail. Wall vertical reinforcing shall be #5 @ 48" OC full height. Unless noted otherwise.
M15. All cores with reinforcing steel shall be grouted solid, full height of wall.
GENERAL NOTES
G1. BUILDING CODES:
Model: International Building
Code 2000
Local: Indiana Building Code 2003
Steel: American Institute of Steel Construction, LRFD 2nd Edition
Concrete: American Concrete Institute, 318 -99.
G2. DESIGN LOADS:
MAIN ROOF
Dead Load:
19 psf
Live Load:
25 psf
MECHANICAL ROOF
Dead Load
21 psf
Live Load
40 psf
UPPER LEVEL PARKING FLOOR
Dead Load:
128.5 psf
Live Load:
50 psf
FIRST FLOOR
Dead Load:
107 psf
Live Load:
80 psf
SECOND FLOOR
Dead Load:
76 psf
Live Load:
80 psf
ATTIC FLOOR
Dead Load:
76 psf
Live Load:
125 psf
SNOW
Ground Snow Load
25 psf (includes 5 psf icing)
Flat Roof Snow Load:
20 psf
Snow Exposure Category:
C
Snow Exposure Factor:
0.9
Snow Importance Factor:
1.00
Thermal Factor:
1
WIND
Basic Wind Speed: 90 mph
Wind Importance Factor: 1.00
Building Classification: 2
Wind Exposure Categroy: C
SEISMIC
Seismic Use Group: I
Seismic Design Category: B
Spectral Response, Sds: 0.14
Spectral Response, Shc: 0.10
Site Class: C
Basic Building System: 3. Moment - resisting Frame System
Basic Resisting System: 3D. Ordinary steel moment frames
Design Base Shear: 0.036 W
Analysis Procedure: Static
G3. Reactions and forces indicated are Unfactored Service loads.
G4. If Drawings and specifications are in conflict, the most stringent restrictions and requirements shall
govern. Contractor shall bring all discrepancies to the attention of the engineer immediately.
G5. Verify all existing conditions prior to any construction or fabrication. If different than shown, notify
engineer /architect immediately for modification of drawings.
G6. All contractors are required to coordinate their work with all disciplines to avoid conflicts. The architectural,
mechanical, electrical and plumbing aspects are not in the scope of these drawings. Therefore, all
required materials and work may not be indicated. It is the contractor's responsibility to coordinate these
drawings with all other construction documents. Refer to architectural drawings for all dimensions not
shown on these drawings. Locations, sizes and numbers of all openings may not be completely indicated
in the structural drawings, the respective contractor shall verify their work with all other disciplines.
G7. The contract documents represent the structure only. They do not indicate the method of construction.
The contractor shall provide all measures necessary to protect the structure during construction. Such
measures shall include, but not limited to, bracing, shoring, underpinning, etc. McComas Engineering is
not responsible for the contractor's means, methods, techniques, sequences or safety procedures during
construction.
G8. Plan notes and details shall take precedence over general structural notes. Where no details or sections
are shown, construction shall conform to similar work on the project. Typical sections and details may not
be cut on the plans, but apply unless noted otherwise.
G9. Provisions for future expansion:
Vertical: None
Horizontal: West to Building 5.
REINFORCED CONCRETE NOTES (Foundations. Slabs & Walls
RC1. All concrete shall have the following 28 day compressive strengths:
LOCATION STRENGTH AIR ENTRAIN.
Wall Footings, Spread Footings: 3000 psi 2%
All concrete below frost line,exterior
slabs, piers, walls, columns, grade beams,
concrete exposed to freeze /thaw: 4000 psi 6%
Interior slabs on grade,
fill for metal deck: 4000 psi Non AE
Topping for upper level parking
hollow core planks: 4000 psi 6%
Topping at first floor hollow core planks: 3000 psi (gyperete)
RC2. All reinforcing steel shall be detailed, supplied and placed in accordance with ACI 315 -99, ACI 318 -99
and CRSI MSP -1-01.
RC3. All reinforcing steel shall be shop fabricated and, where applicable, shall be wired together and conform
to ASTM A -615, Grade 60.
RC4. Chamfer edges of exposed concrete 3/4 ", unless noted otherwise.
RC5. Contractor shall make four, 6 "x12" test cylinders for each 50 cubic yards of concrete poured for each days
operation. Break 1 at 7 days, 2 at 28 days and retain spare.
RC6. All welded wire fabric shall conform to ASTM Al 85, Fy(min) of 65 ksi. All welded wire fabric laps shall be
8 ".
RC7. All finished concrete, concrete formwork and falsework shall be in accordance with ACI 301 -99.
Contractor is solely responsible for the design and construction of all formwork, falsework and shoring.
RCS. Provide the following coverages over reinforcing:
Footings:
Bottom and Unformed edges 3"
Formed edges and top 2"
Slab on grade:
Welded wire fabric Upper Third
Reinforcing Steel 2"
RC9. Provide sleeves for all openings in grade beams or walls to totally seperate pipe from concrete.
SHALLOW FOUNDATION AND SLAB ON GRADE NOTES
SF1. Design Soil Bearing Pressure
Spread Footings 5000 psf
Wall Footings 4000 psf
(Based on soils report prepared by Patroit Engineering, report #1 -04 -1490, dated 12- 29-04. ).
SF2. Soil to be stripped, compacted and tested in accordance with the recommendations of the soils engineer
and project specifications.
SF3. Footings shall be placed on firm, undisturbed soil or on engineered fill. Engineered Fill: Naturally or
artificially graded mixture of natural or crushed gravel, crushed stone, and natural or crushed sand; ASTM
D 2940; with at least 90 percent passing a 1 -1/2 -inch sieve and not more than 12 percent passing a No.
200 sieve.
SF4. Slabs shall be placed on compacted, free - draining, frost -free drainage course. Drainage Course:
Narrowly graded mixture of washed crushed stone, or crushed or uncrushed gravel; ASTM D 448;
coarse - aggregate grading Size 57; with 100 percent passing a 1 -1/2 -inch sieve and 0 to 5 percent
passing a No. 8 sieve. All fill shall be compacted to a minimum dry density of 95% of the modified Proctor
maximum dry density (ASTM- D1557), placed in 6" to 8" lifts. Pea gravel may not be used as fill. Utility
trenches and excavations under the foundations or slabs shall meet the same requirements. See soils
investigation report for further recommendations.
SF5. Undercutting of the soil for foundation and /or slab placement may be required. These drawings do not
indicate the entire scope of undercutting, fill or bad soil removal that may be required to attain the design
soil bearing pressures. It is the responsibility of the contractor to obtain a soils investigation report, before
bidding, to assess the extent of excavation and compaction that may be required to meet the design
criteria. The contractor shall retain the services of a soils engineer to monitor all backfilling operations and
to inspect footing bearing material. A report certified by the soils engineer shall be furnished to the
architect/engineer verifying that all foundations were placed on a material capable of sustaining the
design bearing pressures.
SF6. If dewatering is required, sumps shall not be placed within the foundation excavation.
SF7. Maintain a maximum slope between adjacent footing bearing elevations of 2 horizontal to 1 vertical.
Maintain a 2 horizontal to 1 vertical slope next to existing foundations to avoid undermining foundations.
SF8. No horizontal joints are permitted in any foundation. Vertical joints are permitted only in wall footings.
SF9. Shallow foundations may be earth- formed where the excavation permits. If earth - forming is used, add 2"
to the width and length of all foundations.
SF10. The bottom of all foundations shall be a minimum of 36" below final grade.
PEDCOR DESIGN GROUP
Architecture / Project Managment:
335 Ridgepoint Drive
Carmel, Indiana 46032
317.705.7979 (phone)
317.705.7980 (fax)
Engineer: C. Rodney McComas
k,
nr,r0•nr -
MoCOMAS
_MX' ou -0a M, MEW MM w\na01 m1a I TZ
1717 E"d 118M 9trwr. Sib 200 CanwL I N, a 45M
317 -91D -0/02 rn meoanpNnaean
317-502-OM irm
Developer: p
P E D C 0 R
DEVELOPMENT CO.
U)
W
U
LL
O�
m
W Z oe$ Co
� a�
Q �o�
C: Z
w £
�
V U U
N m d
L.1.
U
D
W
Issue Date Drawn By Checked By
02/28/05 nJh JRt1
Revisions:
MEI Project Number:
24187
Sheet Title:
GENERAL NOTES
LEGENDS AND
ABBREVIATIONS
Sheet Number:
S 1(1()