HomeMy WebLinkAbout05050050.701 E104 Building #5 U GENERAL NOTES: A. All 120v., 20 amp circuits over 100' in length shall be # 10 AWG. B. Conduit system shall be emt above main level ceiling. Contractor may use M.C. cable for branch circuits above accessible ceiling. All homeruns to the panel shall be EMT conduit. C. Contractor shall coordinate with all other trades to avoid conflicts of space. D. Contractor shall coordinate the exact location of all devices with all other trades prior to rough —in. Exact location to be determined in the field. E. Refer to sheet E701 for symbols and details. F. Refer to sheet E601 for riser diagram. G. Refer to sheet E601, E602 and E603 for panel schedules. H. Contractor shall coordinate with the mechanical and plumbing contractors for exact locations of equipment prior to rough —in PLAN NOTES: OContractor shall provide and install a 4 —pole lighting contactor "LC -2" controlled by a 7 day, 24 hour electronic timeclock. er Level Parking Electrical Plan Scale: 1/8" = V -0" � c���� � ; 'WNW, — PEDCOR DESIGN GROUP Architecture / Project Managment: 335 Ridgepoint Drive Carmel, Indiana 46032 317.705.7979 (phone) 317.705.7980 (fax) ©Copyright 2004 O13 ER4, 0�� • �" E�• Svc No. 13968 STATE W Of S��ONA1- %\�\G``�. Consulting Engineer: JOHN OBERLIES CONSULTING ENGINEERS INC. Mechanical • Electrical • Civil • Sanitary Developer: P E D C O R ?�p enkz DEVELOPMENT CO. W U O� m WOOZ$CU CU �Z a Q Ada �cz�; J V � V ry U �m a U D W d Issue Date Drawn By Checked By 02/28/2005 GMH SLH Revisions: Project Number: 0401.00 MEI 24187 Sheet Title: Building #5 Upper Level Parking Electrical Plan Sheet Number: 1: I () ��