HomeMy WebLinkAbout07020031.1MISCELLANEOUS: The structure and its several parts have been designed for the in- service loads only. The methods, means, procedures, and sequences of construction are the responsibility of the Contractor. The Contractor shall take all necessary precautions to insure safe working conditions and maintain the integrity of the structure during all stages of construction. The adequacy of the design of temporary bracing, shoring, etc. is the contractor's responsibility. STRUCTURAL STEEL - Structural steel detailing, fabrication, and erection shall conform to the RISC "Specification for the Design, Fabrication, and Erection of Structural Steel for Buildings ", latest edition with amendments, and the AISC "Code of Standard Practice for Steel Buildings ", 1986 edition with amendments. Structural steel rolled shapes, except plates, shall conform to ASTM A 572, Grade 50, unless otherwise noted. Structural tube steel shall conform to ASTM A 500, Grade B (Fy = 46 ksi). Anchor bolts shall conform to ASTM A 36, unless otherwise noted. Erector shall maintain adequate temporary bracing in each direction until diaphragm and lateral brace construction is completed. Unless otherwise noted, bolted connections for structural steel members shall be made with 3/4" diameter high strength bolts, conforming to ASTM A325. Except as noted, bolted connections shall be tightened to the snug tight condition. Connections shall conform to the "Specification for Structural Joints using ASTM A325 or A490 Bolts ", approved by the Research Council on Structural Connections of the Engineering Foundation. Welding procedures shall conform to the latest edition of the American Welding Society's "Structural Welding Code for Steel ANSI / AWS D1.1", "Reinforcing Steel ANSI / AWS D1.4 ", and "Sheet Steel ASNI / AWS D1.3 ". Welded connections using ASTM A572 steel as a base metal shall be made with E70XX Low Hydrogen electrodes. Unless otherwise shown or noted on the drawings, other welded connections may be made with standard E70XX electrodes. Surfaces within 2- inches of any field weld shall be free of materials that would prevent proper welding or produce toxic fumes while welding is being done. Splicing of structural steel members where not detailed on the contract documents is prohibited without the prior approval of the Structural Engineer as to location, type of splice and connection to be made. The Structural Steel Contractor shall prepare detailed working or shop drawings to enable him to fabricate, erect and construct all parts of the work in accordance with the drawings and specifications and shall submit one reproducible copy and one blue line copy to the Structural Engineer for approval. These shop drawings will be reviewed for design concepts expressed in the contract documents only. The Contractor shall be responsible for all dimensions, accuracy, and fit of work. STEEL JOISTS: Steel bar joists shall be designed, fabricated, erected and braced in accordance with the latest Steel Joist Institute (SJI) specifications. All bar joists shall be shop painted with a gray, rust - inhibiting primer. Steel joists shall be fabricated in accordance with the design specification shown for each joist on the drawings. The design specifications follow the form: DD K TL / LL where DD indicates the maximum joist depth, K indicates the joist series, TL / LL indicates the design total load and live load respectively in pounds per lineal foot. Deflection due to live load shall be limited to 1/360 of the joist span for Floor Joists, & 1/240 of the joist span for Roof Joists. Where bearing depth, length and end anchorages for steel joists are not shown or noted, provide anchorages as required by the SJI specifications. Horizontal bridging and diagonal bridging for steel joists shall be located and designed as required by the SJI specifications. Bridging members shall be connected to the joist chords by welding or other mechanical means. The ends of bridging lines terminating at concrete block walls or steel beams shall be securely anchored thereto at top and bottom chords. Hangers and other supports for mechanical, electrical, or plumbing systems shall be located at the intersection of the chord and web members. Concentrated loads in excess of 200 pounds must be reviewed by the Structural Engineer. Where columns are not framed in at least two directions with steel beams, the joist at or nearest each column line shall be bolted to supporting members during erection. STEEL JOIST GIRDERS: Steel joist girders shall be designed, fabricated, erected and braced in accordance with the latest Steel Joist Institute (SJI) specifications. Joist girders that are part of a moment resistive rigid frame shall be designed for the indicated end moments. All joist girders shall be shop - painted with a gray, rust - inhibiting primer. Joist girders shall be fabricated in accordance with the design specification shown for each joist girder on the drawings. The design specifications follow the form: DD G XN TLK where DD indicates the maximum joist girder depth, G indicates joist girder type, X indicates the number of joist spaces (equal or unequal) occurring in the joist girder span, and TL indicates the total panel point design load (excluding joist girder self weight) in kips. Where "VG" replaces "G ", joist must bear only at vertical joist girder web members. Deflection due to live load shall be limited to 1/360 of the joist girder span for floor joist & 1/240 of joist girder span for roof joists. Stabilizer plates shall be provided on the columns between the joist girder bottom chord angles as required by SJI specifications. DO NOT WELD BOTTOM CHORD ANGLES TO STABILIZER PLATES. UNLESS NOTED. Where end anchorages for joist girders are not shown or noted, provide anchorages as required by the SJI specifications. Joist girder bracing shall be as shown on the shop drawings and as required by the joist girder manufacturer. STEEL DECK: Provide and erect steel deck in accordance with the latest edition of the Steel Deck Institute's Specifications and Code of Standard Practice. Deck manufacturer shall provide all roof deck accessories, including closures, supplementary framing, and sump pans. Steel roof deck and accessories shall be shop painted with a rust inhibited primer. Primer color shall be grey unless noted otherwise. Roof deck which will be exposed to weather shall have one additional finish coat of rust inhibiting paint, field applied. Roof deck shall be attached to the structural steel in accordance with the details shown in the plans. Welding shall be performed in accordance with the latest edition of the American Welding Society's "Structural Welding Code - Sheet Steel ANSI / AWS D1.3 ". Composite steel floor deck supporting interior slabs shall be either shop painted with phosphatized paint or hot -dip galvanized in accordance with ASTM A525, Class G 60. Deck manufacturer shall provide all floor deck accessories, such as edge forms, closures, fillers and pour stops for a complete installation, whether or not such items are detailed on the contract documents. Unless otherwise shown or noted, floor deck shall be attached to the structural steel in accordance with the Manufacturer's recommendations. CENTERLINE — PANEL POINT EDGE OF CURB IF THIS DIMENSION IS MORE THAN 4" ADD 2- 1_2x20/16" AS SHOWN. WELD TO TOP 4 BOTTOM CHORDS (FURNISHED t INSTALLED BY MISC. STEEL CONTRACTOR) STEEL CHANNELS IN DECK CELLS 12" O.G. (OVER JOISTS) UNDER CURBS (BY MISC. STEEL CONTRACTOR) JOIST REI NFORCEMENT AT SCALE: NONE SEE PLAN FOR ADDITIONAL JOIST - REINFORCEMENT, SEE "JOIST REINFORCING AT ROOF TOP UNIT CURBS" THIS SHEET PROVIDE GROSS BRIDGING PLATE 0 EACH CORNER OF THE UNIT IF WEIGHT IS IN EXCESS OF 850 LBS. TOP SEE PLAN FULL WELDED FRAME BEAR ANGLE ON J01 ST TOP CHORDS. (SEE PLAN FOR ANGLE SIZE) I I I I I I I I I I -- ---------- - - - - -- - ROOF OPENING JOIST SUPPORT TYPICAL PER PLAN ROOF OPEN I NG SCALE: NONE SEE PLUMBING DRAWINGS FOR LOCATION AND SIZE OF ROOF DRAIN AND OVERFLOW DRAIN. L 3x3x I /4" FRAME TO SUPPORT DRAIN M 1 TYPICAL ROOF DRA I N SUPPORT 15 PSF SEE PLAN JOIST PER PLAN (TYPICAL) THICKNESS -It _z 4090 Y 1/4 V \_._.... z n PLATE 3/8" ALLOWABLE SERVICE LOADS (Kips) n L -W Dgh 2 6" 82K 3 9" 163K 4 12" 26.IK 5 15" 363K 6 18" 463K 7 21" 56.4K Notes: 1) The capacity of the correction shall be the lesser of: A) Bolt Capacity B) Weld C G) Supporting Plate Capacity D) Web Net Shear 2) Refer to AISC ASD - Manual of Steel Construction (Port 1). 3) Allowable bolt capacity 6 based on 3/4 "m A325 -N Type bolts. 4) For coped beam connections, the capacity of the net shear area of the web shall be verified. T A i 1f=% A 101 fm% rm% 9� A i A o% 1 1 "m 1 I / �L Vvl ill �LV I I VI �t 1/L I TAI L _SD DES 1 GN SCALE: NONE 410 Q1 'N > �� �� QO TYPICAL ROOF DECK ATTACHMENT SCALE: NONE NOTES: 1) 1 1/2" TYPE "B" WIDE RIB, 22 GAGE METAL ROOF DECK - MINIMUM THREE SPAN CONDITION. 2) WELD THROUGH MULTIPLE SHEETS AT ALL END AND SIDE LAPS. 3) END LAPS SHALL OCCUR ONLY AT SUPPORT POINTS. "Au 2 1/2" 0 EXTRA STRONG PIPE " 1 - -- TS 5x5x5/16 CENTERED ON BEAM m 1/4 1 - -- I INSULATION AND ROOFING MATERIALS COL. CAP 3/4" MIN. PROVIDE SEATS Lt FOR JOISTS AND GIRDERS AT TIE -OFF LOCATIONS. TYPICAL DAVIT DETAIL SCALE: NONE GAP PLATE 3116" GAP PLATE 3/16" I ROUND OFF .4r 1 _ 1 EDGES OF PIPE I I PIPE - - - -- I I 0 I I I TYP. I I GRIND 1 I I SMOOTH 1/4 (I/4) � I SECTION ELEVATION MATERIAL TO RELIEVE I SHOP COAT RUST INHIBITING PRIMER AND 1 FIELD APPLIED FINISH GOAT DETAIL "A- SCALE: NONE t = CONNECTED PLATE THICKNESS t WEB min. = 0.51" FOR A36 BEAMS (NOTE 2) -It N 0.37" FOR GR, 50 BEAMS Z � € _ N I" MIN. VARIES I" MIN. \ -O 1//4 V \ E70XX DOUBLE L 4x3 1/2 "x5 /I6" ALLOWABLE SERVICE LOADS QQx) n LSn) b9h Welds (Note 2) 2 5 1/2" 37.IK 49.5K 3 81/2" 55.7K 733K 4 11 1/2" 742K 97K 5 14 1/2" 92.8K 118K 6 17 1/2" I I IK 13W 7 201/2" 130K 158K Notes: 1) The capacity of the connection shall be the lesser of: A) Bolt Capacity B) Io-kld Capacity G) Connected Plate Cgxcity D) Block Shear 2) Allowable weld capacity 6 based on web thicknesses noted above. Ratio this capacity for lesser web thicknesses. 3) Allowable bolt capacity 6 based on 3/4 "m A325 -N Type bolts. 4) Block shear should be checked for coped beams. P► T A 1 11"1 A T00%V"% 1""%A0%1 If"% ANGiLE CONNECTION SCALE: NONE JOI ST SEAT COLUMN BASE ie I II//4 "xl 6"x I' -4" 0 W10 O T l 1 1 Q II _ o ii o I I � TYP. 3/I6 aC I Z SHIMS AND LEVELING NUTS COORDINATE HOLE z (4) - 3/4"0 ANCHOR LOCATIONS W/JOI ST z BOLTS (F -1554, Gr. 36) = SUPPLIER 411 1 1 /211 I 1/211 - IU 1' -6" ELEVATION PLAN PLAN TYPI CAL COLUMN TY bAbt DETA I L JO I SCALE: NONE NO SCALE 1/4 V I TOP OF BEAM EL. PER PLAN T%./100' 1000 A I 1 1 1 1e 3/8" FLANGE TO FLANGE FOR ROOF FLASHING 3/4" BASE fe i 1 /"% 9� SCALE: NONE PROVIDE OPENING FOR DUCTWORK. fBAR JOIST BEAR 0 VERTICAL WEB MEMBERS 140 SLALE TION ERECTION BOLTS BACKING BAR (TYPJ BEAM TO COLUMN MOMENT CONNECTION AT FLANGE SEAT R 1/2 (TYP.) O JOIST GIRDER SEAT JOIST SEAT TMP' 1 61;*0110012 NOTES: I. ALL BOLTS TO BE TIGHTENED TO SLIP CRITICAL CONDITION. 2. ALL BOLT HOLES TO BE STANDARD HOLES. NO FIELD MODIFICATIONS, SLOTTED, OR OVERSIZED HOLES MAY BE USED. 3. WELDED SPLICE MAY BE USED W/ ENGINEER OF RECORD APPROVAL. 1 3/4" 1 7/8" OF SPLICE A0P" /11 I 1%, AL 1 *"11 1� CENTERLINE OF SPLICE fV _I COLUMN SPI SCALE: 3/4" = I' -0" ----SEE ELEVATION FOR ANGLE DETAILS 15/ WO STD HOLES IN TOP AND BOTTOM FLANGE OF W 14x90 W 14x90 X11 1 ► 1 f, I1 0�1 1 7/8 "m ASTM A490 BOLTS. SLIP CRITICAL CONNECTION (TYP. OF 70) STIFFENER ie 3/8" JOIST BEARING EL. PER PLAN GRIND WELD SMOOTH AT SPLICE JOINT `L 4x4x314 "x9" BOTH 51DES PLATE 3/4"xe x2' -2" W/16-15/16"4) HOLES (TYP. OF 4) STIFFENER iL 5/8" COLUMN PER PLAN DWG. DATE: 11/13/06 JOB NUMBER: 06 -213 SCALE: AS NOTED CREATED BY: J.W.G. CHECKED BY: J.A.L. ISSUED FOR: PERMITS 11/13/06 CONSTRUCTION 12/11/06 I ESI #1 12/21/06 2 ESI #2 1/2/07