HomeMy WebLinkAbout07020031.22ci�
�n, -n"
12' -11"
518" TYPE - "X'
GONG. SLAB
SEE STRUGT.
T00 INTi T FLAN
1/411 = !I-Oil
ENE AL NOTES
I. THE DRAHIN65 AND SPECIFICATIONS ARE AN INSTRUMENT OF SERVIGE
AND ARE THE SOLE PROPERTY OF THE ARCHITECT. ANY RE -U5E OR
DUPLICATION OF THESE DOCUMENTS 15 PROHIBITED WITHOUT THE
EXPRESSED WRITTEN CONSENT OF THE ARCHITECT.
2. EACH CONTRACTOR SHALL REVIEW ALL DRAHIN65 TO DETERMINE
FULL EXTENT OF RESPONSIBILITIES FOR EACH RESPECTIVE TRADE.
3. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE HITH ALL
APPLICABLE CODES, LAWS, AND ORDINANCES.
4. ALL DIMENSIONS ARE FACE TO FACE DIMENSIONS (E.6. STUD TO STJD,
MA50NRY TO MASONRY) UNLESS NOTED OTHERWISE.
5. COORDINATE WORK OF THIS TRADE WITH WORK OF OTHER TRADES
6. VERIFY ALL EXI5TIN6 CONDITIONS PRIOR TO START OF CONSTRUCTION.
NOTIFY ARCHITECT IMMEDIATELY OF CONFLICTS PRIOR TO PROGEEDIN6.
1. ALL OR PART OF THESE DOCUMENTS HERE GENERATED BY ELECTRONIC
MEANS. THE ARGHITECT/ENOINEER 15 RELYING ON THE ACCURACY OF THE
SOFTWARE EMPLOYED. THE ARCH ITECT/EN6INEER'S LIABILITY 15 THEREFORE
LIMITED TO THE EXTENT CUSTOMARY IN THE INDUSTRY.
8. CONTACT RESPECTIVE UTILITY COMPANY FOR EXACT LOCATION OF
UNDERGROUND SERVICES PROR TO START OF CONSTRUCTION. TAKE
EVERY PRECAUTION NECESSARY TO PROTECT EXI5TIN6 SERVICES
DURING CONSTRUCTION.
q. EACH CONTRACTOR 15 REQUIRED TO REMOVE ALL CARTONS, BOXES,
MATERIALS, TRASH AND DEBRIS CAUSED BY HI5 WORK FROM THE JOB
51TE DAILY.
10. EACH CONTRACTOR SHALL PROVIDE ALL BARRICADES, ETC. AS REQUIRED
BY LAW, CODE OR ORDINANCE AND AS OTHERWISE REQUIRED.
11. DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS.
WHERE MORE THAN ONE DOOR OCCURS IN A ROOM A SUFFIX HAS
BEEN ADDED (I.E. IOIA). SEE DOOR SCHEDULE SHEET A501.
12. PROVIDE WOOD BLOCKING SUPPORT FOR ALL SURFACE MOUNTED
ITEMS MOUNTED TO FACE OF 6YP5UM WALLBOARD WALLS.
13. CAULK JUNCTURES BETWEEN DIFFERENT MATERIALS (E.6. DRYWALL
AND MASONRY).
14. CAULK ALL TOILET FIXTURES TO WALL OR FLOOR U51N6 SILICONE SEALANT.
SPANFDRAL 6LA55 15. CAULK ALL COUNTERTOP BAGKSPLA5HE5 TO WALL U51N6 SILICONE
SEALANT IN COLOR AS SELECTED BY OWNER.
16. ALL INTERIOR GYPSUM WALLBOARD TO BE 5/8" TYPE 'X' UNLESS NOTED
OTHERWISE. SEE SPECIFICATIONS FOR OTHER REQUIREMENTS.
17. ALL INTERIOR STUD WALLS TO BE 3 518" METAL STUDS @ 16" O.G.
UNLE55 NOTED OTHERWISE. SEE SPECIFICATIONS FOR OTHER REQUIREMENTS.
18. PROVIDE WOOD BLOGKIN6 SUPPORT FOR ALL REGE55ED MOUNTED ITEMS.
REVIEW PLANS AND SPECS. FOR REQUIREMENTS.
5PANDRAL 6LA55 Y ALL TYPES
5PANDRAL 6LA55
3 -518" x 206A. METAL STUDS @ 16" O.G.
WI W/ (1) LAYERS 5/8" TYPE "X" G.W.B. EACH 51DE
I SOUND ATTENUATION BLANKETS
TO DECK ABOVE. (I -HOUR)
3 -5/8" x 206A. METAL STUDS @ 16" O.G.
W2 H/ (2) LAYERS 5/8" TYPE "X" G.W.B. EACH 51DE
i SOUND ATTENUATION BLANKETS
TO DECK ABOVE. (2 -HOUR)
W3 (N -7/8" METAL FURRING CHANNELS
24" O.G. OVER 12" G.M.U.
TO 6" ABOVE FINISH GEILIN6.
W4 2 112" x 206A. METAL 5TUD5 @ 16" O.G.
m W/ 5/8" TYPE - "X" G.W.B. ONE SIDE
& SOUND ATTENUATION BLANKETS
TO DECK ABOVE.
SOUND ATTENUATION BLANKETS
3 518" METAL STUDS @ 16" O.G.
5/8" TYPE - "X" 6YP. BRD.
GAULKIN6
4" DEEP REGE55ED SLAB
SEE STRUGT. DH65.
RE�ESSE[�) SLA5 SET AIL
1 1/2 " =1' -0"
SIMMONS
ARCHITECTS, LLC
ARCHITECTS, PLANNERS
305 East New York Street
Indianapolis, Indiana 46204
(317) 656 -3500 Fax (317) 656 -3501
z
V U
LLJ
.4.0 W
cu
UA
Q W<
ZQ
LL
z �F— Wr-)
° Z
0)C
mU c:
LLJ -0 C
°�
N
LLJ
Lu
J W
c0
0° N
YLL
W
N
O
m O
cnn O
U
CERTIFIED BY:
NORTH:
p
I
i
I
I
i
LU U
�
I
z
Lu
N1
Of
i
SHEET NO.
A203
ENLAROEMENT PLANS