HomeMy WebLinkAbout13020148.2-A . SCALE - 1/4•• = 1' WALL TYPES A. 38" Metal studs w/ 8" type 'X' gyp.bd. eachside - top @ 10' -0 "AFF B. 38" metal studs w/ 8" type 'X' gyp.bd. each side - close to deck above C. 38" metal studs w/ 8" gyp.bd. each side - 6" above finished counter top. D. 38" metal studs w /8" type 'X' gyp.bd. each side - top @ 48" AFF E.existing wallso to remain F.6" metal studs w/ 8" type 'X' gyp.bd. each side - close to deck above X w EXPOSED STRUCTURE EXISTING LIGHTING & HVAC TO REMAIN EXISTING CEILING TO REMAIN I J NEW BULKHEAD AT - 8' -0" AFF lIX_� CEILING AT 10' -0" AFF WAHSABLE CEILING PANELS �❑ u EXPOSED STRUCTURE EXISTING LIGHTING & HVACTO REMAIN REFLECTED CEILING PLAN SCALE - 1/4•• = 1' EXIT Li F I- DCEILING AT 10' -0" AFF CEILING PANELS 1:1:11 I III LE=qrn lIX� 1 -1 0 EXHAUST HOOD GENERAL NOTES 1. Contractor shall be responsible for verification of all dimension and job conditions. Any deviation from what is noted in drawings shall be brought to the attention of the architect immediately 2. All dimensions shown are face of drywall unless noted otherwise 3. Provide deep leg deflection track at all metal stud connections with structure above - typical 4. Provide fire rated wood blocking in metal stud walls for any wall supported items 5. Provide approved fire rated stopping materials in any openings in fire rated assemblies 6. Refer to door and window schedules for all materials, finishes and hardware information 7. All materials located in ceiling plenum shall be rated for such installation or protected to provide compliance this includes but is not limited to power and low voltage wiring telecommunications cabling, plumbing supply and drain lines and supporting brackets and /or blocking for ceiling hung items 8. Prior to ordering any products - contractor shall submit to samples to the architect of all finish materials to be used on the project. The contractor shall bear sole responsibility for any materials ordered incorrectly when that material was not reviewed by the architect 9. Provide concrete filled steel pipe bollards at all required utility equipment locations such as gas meters, electrical transformers, panels etc. Coordinate with utility company and contractors - when applicable - for necessary locations. Refer to civil drawings for bollards specifications and additional information KEYED NOTES 1. New metal stud and 5/8" gyp board bulkhead with bottom at 8' -0" aff, width as shown. To have blocking throughout for surface mount televisions as noted (Blocking to be installed throughout) 2. New metal stud and 5/8" gyp board with bottom 1" below ceiling grid height, width as shown 3. Exterior emergency exit light installed over door and wired to exit sign /battery backup. Match exiting style on building if possible and if not existing 4. Store lighting is to be controlled through breakers. 5. Pendant fixtures to be provided by tenant and installed by GC. Provide power, FR blocking ECT... to accommodate fixture. For energy code calculations, fixture has maximum rated wattage of 500 watts. 6. Not Used 7. Ceiling mounted duplex outlet with added support for TV mounting 8. Duplex outlet provided within bulkhead with blank box with pull string for television connection (Televistion wintrolls by others) Legend Junction boxes coordinate with tenant on wiring requirements ® Building standard 2x4 fluorescent light fixture existing to remain ® 2x4 fluorescent light fixture with acrylic lens. (2) 32WT8 lamps 73 Watts total ® Denotes light fixture wired to 24 hour circuit ( "night light ") o- Pendant hung light fixture to be selected 18W fluorescent can light with white trim ring 23 watts total OThermostat Wall mounted light or other switch 3 = 3 way switch 4 = 4 way switch D = electronic dimmer '�'9 Wall mounted emergency light w/ 90 min. backup. Equal to navilite N1WH with (2) 5.4 watt lamps, 11 watts total EXIT Wall mounted exit light w/ 90 min. backup equal to navilite NXP3GWH. 2.7 watt total LED lamps FE_x­I_T1 Wall Mounted combo emergency light and exit light w/ 90 min. backup. Equal to navilite NXPC3GWH. 4.2 watts total standby Existing ceiling grid ® Gypsum board bulkhead Diffuser - Supply Diffuser - Return 9,111 ES ®Combination fluorescent light /fan ducted to exterior. Equal to Boran QTXE- 150FLT with (2) 18 watt lamps, 48 watts total Note: Supply and Return locations shown on plans for reference only. Contractor is to provide new layout under design - build contract Mechianical contractor is to locate all roof mounted equipment for structural stability and to provide any required bracing and support needed for any roof top equipment. Provide deduct alternate to re -lamp existing 2x4 fixtures and re- install in rooms: Utility, Dry Storage, Kitchen, Prep and serving areas Final location and selection of all fixtures to be coordinated with tenant and architect CEILING HEIGHT IS EXISTING (10' -0 ") } co c W L cc W Li N W cc JtN N W Z Q Z Q �/ X 1-- W J G. u a � J co Q z J J � W W N fNQ U U N Z a W W N Ln in CL X N IX q-' 4 o W tA ?o J H Q i Zm Q W W J r Y � 00 Ir Q rn N LL U W U Q N u W H_ Li CC Q JtN Q �/ X 1-- W M cn a � co Q z J � W N fNQ U N a PROJECT NUMBER 2013.02 DATE: FEBRUARY 4TH 2013 DRAWING NUMBER A -1 OF DRAWINGS