SCALE - 1/4•• = 1'
WALL TYPES
A. 38" Metal studs w/ 8" type 'X' gyp.bd.
eachside - top @ 10' -0 "AFF
B. 38" metal studs w/ 8" type 'X' gyp.bd.
each side - close to deck above
C. 38" metal studs w/ 8" gyp.bd. each side
- 6" above finished counter top.
D. 38" metal studs w /8" type 'X' gyp.bd.
each side - top @ 48" AFF
E.existing wallso to remain
F.6" metal studs w/ 8" type 'X' gyp.bd.
each side - close to deck above
X
w
EXPOSED STRUCTURE
EXISTING LIGHTING &
HVAC TO REMAIN
EXISTING CEILING
TO REMAIN
I J
NEW BULKHEAD
AT - 8' -0" AFF
lIX_�
CEILING AT
10' -0" AFF
WAHSABLE
CEILING PANELS �❑
u
EXPOSED STRUCTURE
EXISTING LIGHTING &
HVACTO REMAIN
REFLECTED CEILING PLAN
SCALE - 1/4•• = 1'
EXIT
Li
F I-
DCEILING AT
10' -0" AFF
CEILING PANELS
1:1:11 I III
LE=qrn
lIX�
1 -1
0
EXHAUST
HOOD
GENERAL NOTES
1. Contractor shall be responsible for verification of all
dimension and job conditions. Any deviation from what is
noted in drawings shall be brought to the attention of the
architect immediately
2. All dimensions shown are face of drywall unless noted
otherwise
3. Provide deep leg deflection track at all metal stud
connections with structure above - typical
4. Provide fire rated wood blocking in metal stud walls for any
wall supported items
5. Provide approved fire rated stopping materials in any
openings in fire rated assemblies
6. Refer to door and window schedules for all materials,
finishes and hardware information
7. All materials located in ceiling plenum shall be rated for such
installation or protected to provide compliance this includes
but is not limited to power and low voltage wiring
telecommunications cabling, plumbing supply and drain lines
and supporting brackets and /or blocking for ceiling hung
items
8. Prior to ordering any products - contractor shall submit to
samples to the architect of all finish materials to be used on
the project. The contractor shall bear sole responsibility for
any materials ordered incorrectly when that material was
not reviewed by the architect
9. Provide concrete filled steel pipe bollards at all required
utility equipment locations such as gas meters, electrical
transformers, panels etc. Coordinate with utility company
and contractors - when applicable - for necessary locations.
Refer to civil drawings for bollards specifications and
additional information
KEYED NOTES
1. New metal stud and 5/8" gyp board bulkhead with
bottom at 8' -0" aff, width as shown. To have blocking
throughout for surface mount televisions as noted
(Blocking to be installed throughout)
2. New metal stud and 5/8" gyp board with bottom 1"
below ceiling grid height, width as shown
3. Exterior emergency exit light installed over door and
wired to exit sign /battery backup. Match exiting style on
building if possible and if not existing
4. Store lighting is to be controlled through breakers.
5. Pendant fixtures to be provided by tenant and installed
by GC. Provide power, FR blocking ECT... to accommodate
fixture. For energy code calculations, fixture has
maximum rated wattage of 500 watts.
6. Not Used
7. Ceiling mounted duplex outlet with added support for
TV mounting
8. Duplex outlet provided within bulkhead with blank box
with pull string for television connection (Televistion
wintrolls by others)
Legend
Junction boxes coordinate with tenant on wiring
requirements
® Building standard 2x4 fluorescent light fixture existing to
remain
® 2x4 fluorescent light fixture with acrylic lens. (2) 32WT8
lamps 73 Watts total
® Denotes light fixture wired to 24 hour circuit ( "night light ")
o- Pendant hung light fixture to be selected
18W fluorescent can light with white trim ring 23 watts
total
OThermostat
Wall mounted light or other switch
3 = 3 way switch
4 = 4 way switch
D = electronic dimmer
'�'9 Wall mounted emergency light w/ 90 min. backup. Equal
to navilite N1WH with (2) 5.4 watt lamps, 11 watts total
EXIT Wall mounted exit light w/ 90 min. backup equal to navilite
NXP3GWH. 2.7 watt total LED lamps
FE_xI_T1 Wall Mounted combo emergency light and exit light w/ 90
min. backup. Equal to navilite NXPC3GWH. 4.2 watts total
standby
Existing ceiling grid
® Gypsum board bulkhead
Diffuser - Supply
Diffuser - Return
9,111 ES
®Combination fluorescent light /fan ducted to exterior.
Equal to Boran QTXE- 150FLT with (2) 18 watt lamps, 48
watts total
Note: Supply and Return locations shown on plans for reference
only. Contractor is to provide new layout under design - build
contract
Mechianical contractor is to locate all roof mounted equipment
for structural stability and to provide any required bracing and
support needed for any roof top equipment.
Provide deduct alternate to re -lamp existing 2x4 fixtures and
re- install in rooms: Utility, Dry Storage, Kitchen, Prep and serving
areas
Final location and selection of all fixtures to be coordinated with
tenant and architect
CEILING HEIGHT IS EXISTING (10' -0 ")
}
co
c
W
L
cc
W
Li
N
W
cc
JtN
N
W
Z
Q
Z
Q
�/
X
1--
W
J
G.
u
a
�
J
co
Q
z
J
J
�
W
W
N
fNQ
U
U
N
Z
a
W
W
N
Ln
in
CL
X
N
IX
q-'
4 o
W
tA
?o
J
H
Q
i
Zm
Q
W
W
J r
Y �
00
Ir
Q rn
N
LL
U
W
U
Q
N
u
W
H_
Li
CC
Q
JtN
Q
�/
X
1--
W
M
cn
a
�
co
Q
z
J
�
W
N
fNQ
U
N
a
PROJECT NUMBER 2013.02
DATE: FEBRUARY 4TH 2013
DRAWING NUMBER
A -1
OF DRAWINGS